Anton Roaldovich Gorbushin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anton Roaldovich Gorbushin has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
S. A. Glazkov
Central Aerohydrodynamic Institute
7 shared publicationsA. V. Semenov
Central Aerohydrodynamic Institute
6 shared publications- Alexander Kozik
Central Aerohydrodynamic Institute (TsAGI), Zhukovsky, Russian Federation
5 shared publications E. A. Krapivina
Central Aerohydrodynamic Institute
4 shared publicationsS. V. Matyash
Central Aerohydrodynamic Institute
4 shared publications- Sergey Aleksandrovich Glazkov
Central Aerohydrodynamic Institute (TsAGI), Zhukovsky, Russian Federation
4 shared publications
Latest Publications
- 12 November 2026
- Published by Springer Nature in Shock Waves
- Vol. 36 (3)
Improved method for measuring non-stationary axial forces using six-component strain-gauge balances
- 12 November 2026
- Published by Springer Nature in Shock Waves
- Vol. 36 (3)
Improved method for measuring non-stationary axial forces using six-component strain-gauge balances
- 1 May 2026
- Published by Pleiades Publishing Ltd in Lobachevskii Journal of Mathematics
- Vol. 47 (5) , 2207-2219
Friction Coefficient and Pressure Fluctuations in a Canonical Turbulent Boundary Layer at Very High Reynolds Numbers
The results of measurements of the skin-friction coefficient, velocity profile, and wall static pressure fluctuations in an incompressible equilibrium turbulent boundary layer with zero pressure gradient, formed on the wall of a transonic wind tunnel at very high Reynolds numbers, are presented. The Reynolds number based on the momentum thickness ranged from \(1.43\times 10^{4}\) to \(2.51\times 10^{5}\). The unsteady friction force was measured using a high-precision floating element, with an uncertainty of \(1{-}1.3\%\). The boundary-layer velocity profile was obtained using a rake of total pressure probes. Wall static pressure fluctuations were measured using Kulite sensors. The mean skin-friction coefficient values are consistent with available experimental data in the literature, semi-empirical correlations, and DNS results. The study allowed refinement of the Kármán constant to \(k=0.391\), as well as adjustment of coefficients in known empirical and semi-empirical relationships relating the skin-friction coefficient to \({\textrm{Re}}{\theta}\). In addition to the mean values, fluctuations of the skin-friction coefficient, spatially averaged over the floating-element surface, were obtained in the frequency range up to \(250\textrm{ Hz}\). A correlation was identified between fluctuations of the skin-friction coefficient and wall static pressure associated with large-scale turbulent structures in the boundary layer. The results may be used for validation of turbulence models and DNS data, as well as for estimating drag of trains, large aircraft, and ships.- 1 May 2026
- Published by Pleiades Publishing Ltd in Lobachevskii Journal of Mathematics
- Vol. 47 (5) , 2207-2219
Friction Coefficient and Pressure Fluctuations in a Canonical Turbulent Boundary Layer at Very High Reynolds Numbers
The results of measurements of the skin-friction coefficient, velocity profile, and wall static pressure fluctuations in an incompressible equilibrium turbulent boundary layer with zero pressure gradient, formed on the wall of a transonic wind tunnel at very high Reynolds numbers, are presented. The Reynolds number based on the momentum thickness ranged from \(1.43\times 10^{4}\) to \(2.51\times 10^{5}\). The unsteady friction force was measured using a high-precision floating element, with an uncertainty of \(1{-}1.3\%\). The boundary-layer velocity profile was obtained using a rake of total pressure probes. Wall static pressure fluctuations were measured using Kulite sensors. The mean skin-friction coefficient values are consistent with available experimental data in the literature, semi-empirical correlations, and DNS results. The study allowed refinement of the Kármán constant to \(k=0.391\), as well as adjustment of coefficients in known empirical and semi-empirical relationships relating the skin-friction coefficient to \({\textrm{Re}}{\theta}\). In addition to the mean values, fluctuations of the skin-friction coefficient, spatially averaged over the floating-element surface, were obtained in the frequency range up to \(250\textrm{ Hz}\). A correlation was identified between fluctuations of the skin-friction coefficient and wall static pressure associated with large-scale turbulent structures in the boundary layer. The results may be used for validation of turbulence models and DNS data, as well as for estimating drag of trains, large aircraft, and ships.- 1 September 2025
- Published by Springer Nature in Measurement Techniques
- Vol. 68 (5-6) , 297-309
Methods for evaluating the mass of objects in motion by using a one-component strain-gauge dynamometer
- 1 September 2025
- Published by Springer Nature in Measurement Techniques
- Vol. 68 (5-6) , 297-309
Methods for evaluating the mass of objects in motion by using a one-component strain-gauge dynamometer
- 14 July 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 74 (3) , 49-58
Methods for determining the mass of objects in motion using a one-component strain-gauge dynamometer
Increasing accuracy of weight-in-motion measurements is considered. Mass of moving objects is calculated through the measurement of unsteady force with the help of one-component strain-gauge dynamometers. It is shown that existing methods of dynamic weighing enable the measurement of non-stationary forces with an uncertainty exceeding 10 %. Such high error is related to the fact that, with higher speed, the accuracy of dynamic load measurements becomes more dependent on dynamical characteristics of the one-component strain-gauge dynamometer. New methods of dynamic load measurement eliminating the systematic error related to the dynamometer’s own dynamics have to be developed to increase mass determination accuracy. Two methods for weight-in-motion measurement of the mass of loads moving on the sensitive platform of a one-component strain-gauge dynamometer at high velocities are developed. Mass determination is carried out over a wide frequency range of the dynamometer, including the natural frequency. In order to apply the first method, only the dynamometer readings in the vicinity of the given point of time for calculating first and second time derivatives of the readings and the dynamical parameters of the dynamometer determined in laboratory conditions are required. To use the second method, it is necessary to first determine the natural frequency of the dynamometer with a platform, and then the frequency of the platform with the moving load. Then, measurement data obtained through methods one or two are used for calculating the mass. Average error in determining the mass using the first method was 2.8 %, and using the second method – 4.1 %. At the same time, the error did not exceed 6.0 %. The developed technology for determining the mass of moving objects can be implemented in weighing hardware for the use in many areas of industry, trade, agriculture and other.
- 14 July 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 74 (3) , 49-58
Methods for determining the mass of objects in motion using a one-component strain-gauge dynamometer
Increasing accuracy of weight-in-motion measurements is considered. Mass of moving objects is calculated through the measurement of unsteady force with the help of one-component strain-gauge dynamometers. It is shown that existing methods of dynamic weighing enable the measurement of non-stationary forces with an uncertainty exceeding 10 %. Such high error is related to the fact that, with higher speed, the accuracy of dynamic load measurements becomes more dependent on dynamical characteristics of the one-component strain-gauge dynamometer. New methods of dynamic load measurement eliminating the systematic error related to the dynamometer’s own dynamics have to be developed to increase mass determination accuracy. Two methods for weight-in-motion measurement of the mass of loads moving on the sensitive platform of a one-component strain-gauge dynamometer at high velocities are developed. Mass determination is carried out over a wide frequency range of the dynamometer, including the natural frequency. In order to apply the first method, only the dynamometer readings in the vicinity of the given point of time for calculating first and second time derivatives of the readings and the dynamical parameters of the dynamometer determined in laboratory conditions are required. To use the second method, it is necessary to first determine the natural frequency of the dynamometer with a platform, and then the frequency of the platform with the moving load. Then, measurement data obtained through methods one or two are used for calculating the mass. Average error in determining the mass using the first method was 2.8 %, and using the second method – 4.1 %. At the same time, the error did not exceed 6.0 %. The developed technology for determining the mass of moving objects can be implemented in weighing hardware for the use in many areas of industry, trade, agriculture and other.
- 22 April 2025
- Published by Springer Nature in Flow, Turbulence and Combustion
- Vol. 115 (2) , 643-675
Investigation of a Sharp 10° Cone in a Ludwieg Tube
- 22 April 2025
- Published by Springer Nature in Flow, Turbulence and Combustion
- Vol. 115 (2) , 643-675
Investigation of a Sharp 10° Cone in a Ludwieg Tube
- 1 September 2024
- Published by Pleiades Publishing Ltd in Thermophysics and Aeromechanics
- Vol. 31 (5) , 915-928
Results of experimental investigations of aerodynamic characteristics of a sharp cone aimed at creating a validation basis for testing computer programs and models
The results of an experimental study of the flow around a 10 ° sharp cone in two large-scale TsAGI wind tunnels are presented. The Mach and Reynolds numbers of the free-stream flow varied in a wide range of M = 0.2–6 and Re = 3–34 million. The drag, lift, and side force coefficients were measured. The behavior of the pitching, rolling, and yawing moment coefficients was studied. The distribution of static pressure on the cone surface and pressure fluctuations were analyzed. A physical model of the cone streamlining was constructed. An ordered system of data was prepared to contain both the results of experiments and test calculations, intended for the validation of computer programs and models.
- 1 September 2024
- Published by Pleiades Publishing Ltd in Thermophysics and Aeromechanics
- Vol. 31 (5) , 915-928
Results of experimental investigations of aerodynamic characteristics of a sharp cone aimed at creating a validation basis for testing computer programs and models
The results of an experimental study of the flow around a 10 ° sharp cone in two large-scale TsAGI wind tunnels are presented. The Mach and Reynolds numbers of the free-stream flow varied in a wide range of M = 0.2–6 and Re = 3–34 million. The drag, lift, and side force coefficients were measured. The behavior of the pitching, rolling, and yawing moment coefficients was studied. The distribution of static pressure on the cone surface and pressure fluctuations were analyzed. A physical model of the cone streamlining was constructed. An ordered system of data was prepared to contain both the results of experiments and test calculations, intended for the validation of computer programs and models.
- 19 January 2024
- Published by Elsevier in Measurement
- Vol. 226
Non-stationary load measurement using six-component strain-gauge balances
- 19 January 2024
- Published by Elsevier in Measurement
- Vol. 226
Non-stationary load measurement using six-component strain-gauge balances
- 18 October 2023
- Published by Elsevier in Measurement
- Vol. 223
Novel method for measuring non-stationary pitch and roll angles with a pendulous accelerometer in the presence of vibrations
- 18 October 2023
- Published by Elsevier in Measurement
- Vol. 223
Novel method for measuring non-stationary pitch and roll angles with a pendulous accelerometer in the presence of vibrations
- 1 October 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 66 (7) , 498-507
Strain gauge dynamometer for measuring the boundary layer friction force on the walls of wind tunnels
- 1 October 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 66 (7) , 498-507
Strain gauge dynamometer for measuring the boundary layer friction force on the walls of wind tunnels
- 31 August 2023
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 7,p. 41-48
Investigation of a strain-gauge dynamometer for measuring boundary layer friction force on the wind tunnel wall
A one-component strain-gauge dynamometer with a measuring range of 0-0.33 N was developed and manufactured at the Central Aerohydrodynamic Institute to measure directly the unsteady friction force of the boundary layer on the wall of a wind tunnel at very high Reynolds numbers. The subject of this study is to investigate the static and dynamic characteristics of the dynamometer and its systematic errors. The effects of the temperature, longitudinal, normal, and side forces and position of the longitudinal force application were investigated during the calibration. A block was designed and manufactured to calibrate the dynamometer using the dead weights in a wind tunnel. The calibration was carried out in laboratory conditions to determine friction force in the block. The developed dynamometer is a dynamic system with its own natural frequency of oscillations. The correction for the dynamometer's own dynamics is suggested on the basis of the method developed earlier. To calculate the correction to dynamometer dynamics the mass of the metric part of the dynamometer, its natural frequency in the absence of damping and the damping coeffi cient were determined. The correction is verifi ed by experiment with application of a step force. Effect of static and dynamic temperature components on dynamometer readings is investigated. Corrections are proposed to eliminate the systematic errors due to the effect of temperature on the basis of the previously developed method. It is shown that the side force does not affect the dynamometer readings, while the effect of the normal force is 1.1 % of the main sensitivity coeffi cient. The effect of the static temperature component on the sensitivity coeffi cient of the dynamometer is 0.017 %/°C. The total measurement uncertainty of the friction force dynamometer is estimated – the standard deviation of the measurement results does not exceed 0.076 % of the measurement range and the relative standard deviation of the main sensitivity coeffi cient is 0.03 %. The standard deviation of measurement of the nonstationary friction force will not exceed 0.86 % of the range of the dynamometer in the presence of oscillations of the sensitive element at its natural frequency.
- 31 August 2023
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 7,p. 41-48
Investigation of a strain-gauge dynamometer for measuring boundary layer friction force on the wind tunnel wall
A one-component strain-gauge dynamometer with a measuring range of 0-0.33 N was developed and manufactured at the Central Aerohydrodynamic Institute to measure directly the unsteady friction force of the boundary layer on the wall of a wind tunnel at very high Reynolds numbers. The subject of this study is to investigate the static and dynamic characteristics of the dynamometer and its systematic errors. The effects of the temperature, longitudinal, normal, and side forces and position of the longitudinal force application were investigated during the calibration. A block was designed and manufactured to calibrate the dynamometer using the dead weights in a wind tunnel. The calibration was carried out in laboratory conditions to determine friction force in the block. The developed dynamometer is a dynamic system with its own natural frequency of oscillations. The correction for the dynamometer's own dynamics is suggested on the basis of the method developed earlier. To calculate the correction to dynamometer dynamics the mass of the metric part of the dynamometer, its natural frequency in the absence of damping and the damping coeffi cient were determined. The correction is verifi ed by experiment with application of a step force. Effect of static and dynamic temperature components on dynamometer readings is investigated. Corrections are proposed to eliminate the systematic errors due to the effect of temperature on the basis of the previously developed method. It is shown that the side force does not affect the dynamometer readings, while the effect of the normal force is 1.1 % of the main sensitivity coeffi cient. The effect of the static temperature component on the sensitivity coeffi cient of the dynamometer is 0.017 %/°C. The total measurement uncertainty of the friction force dynamometer is estimated – the standard deviation of the measurement results does not exceed 0.076 % of the measurement range and the relative standard deviation of the main sensitivity coeffi cient is 0.03 %. The standard deviation of measurement of the nonstationary friction force will not exceed 0.86 % of the range of the dynamometer in the presence of oscillations of the sensitive element at its natural frequency.