Taku Nakamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Taku Nakamura has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Akio Yamamoto
Graduate School of Frontier Sciences, The University of Tokyo, Kashiwa, Japan
5 shared publications Akio Yamamoto
Department of Precision Engineering, The University of Tokyo, Tokyo, Japan
4 shared publications- Fuminobu Kimura
Univ Tokyo, Bunkyo Ku, Tokyo 1138656, Japan
1 shared publication Shota Nemoto
The University of Tokyo
1 shared publication- Takumi Ito
The University of Tokyo
1 shared publication - Tatsuya Koyama
Railway Technical Research Institute
1 shared publication
Latest Publications
- 25 August 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit
Applicability of contact wire splices for shinkansen overhead contact lines with respect to fatigue fracture
Contact wire splice fittings are widely used in railway systems to enable partial replacement of locally worn or damaged contact wires. However, their application has long been prohibited in the Japanese Shinkansen system due to concerns regarding loss of contact, accelerated wear, and particularly fatigue fracture. Recent reports from France of fatigue fractures near splice fittings in high-speed operation zones have highlighted the need for quantitative evaluation of splice-induced mechanical effects. This study investigates the applicability of contact wire splice fittings to Shinkansen overhead contact line systems from the viewpoint of fatigue fracture. Dynamic experiments were conducted using a full-scale test rig, and contact wire strain near splice fittings was evaluated over a range of pantograph velocities. The results show that the strain increase remains moderate at low normalized pantograph velocities but increases rapidly as the running velocity approaches the wave propagation velocity of the contact wire. To clarify the underlying mechanisms, a strain estimation method was developed that accounts for the effects of splice bending stiffness and added mass. The method successfully reproduces the experimentally observed trends, revealing that bending stiffness dominates strain increase at lower velocities, whereas splice mass becomes the governing factor at higher normalized velocities. By incorporating empirically identified dynamic effects and aerodynamic uplift of the pantograph, the applicable speed range of splice fittings was discussed in relation to a fatigue fracture reference strain. The results indicate that, from the viewpoint of contact wire fatigue fracture, splice fittings can potentially be applied safely up to a normalized pantograph velocity of approximately 0.6, which represents a conservative guideline within the proposed assessment framework. This study provides a quantitative framework for reassessing the applicability of contact wire splice fittings in high-speed railway overhead contact line systems.
- 25 August 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit
Applicability of contact wire splices for shinkansen overhead contact lines with respect to fatigue fracture
Contact wire splice fittings are widely used in railway systems to enable partial replacement of locally worn or damaged contact wires. However, their application has long been prohibited in the Japanese Shinkansen system due to concerns regarding loss of contact, accelerated wear, and particularly fatigue fracture. Recent reports from France of fatigue fractures near splice fittings in high-speed operation zones have highlighted the need for quantitative evaluation of splice-induced mechanical effects. This study investigates the applicability of contact wire splice fittings to Shinkansen overhead contact line systems from the viewpoint of fatigue fracture. Dynamic experiments were conducted using a full-scale test rig, and contact wire strain near splice fittings was evaluated over a range of pantograph velocities. The results show that the strain increase remains moderate at low normalized pantograph velocities but increases rapidly as the running velocity approaches the wave propagation velocity of the contact wire. To clarify the underlying mechanisms, a strain estimation method was developed that accounts for the effects of splice bending stiffness and added mass. The method successfully reproduces the experimentally observed trends, revealing that bending stiffness dominates strain increase at lower velocities, whereas splice mass becomes the governing factor at higher normalized velocities. By incorporating empirically identified dynamic effects and aerodynamic uplift of the pantograph, the applicable speed range of splice fittings was discussed in relation to a fatigue fracture reference strain. The results indicate that, from the viewpoint of contact wire fatigue fracture, splice fittings can potentially be applied safely up to a normalized pantograph velocity of approximately 0.6, which represents a conservative guideline within the proposed assessment framework. This study provides a quantitative framework for reassessing the applicability of contact wire splice fittings in high-speed railway overhead contact line systems.
- 8 July 2017
- Published by Springer Nature
- p. 197-199
Substituted Force Feedback Using Palm Pressurization for a Handheld Controller
- 8 July 2017
- Published by Springer Nature
- p. 197-199
Substituted Force Feedback Using Palm Pressurization for a Handheld Controller
- Open Access
- 14 June 2017
- Published by Springer Nature in ROBOMECH Journal
- Vol. 4 (1) , 1-10
Modeling and control of electroadhesion force in DC voltage
- 14 June 2017
- Published by Springer Nature in ROBOMECH Journal
- Vol. 4 (1) , 1-10
Open AccessModeling and control of electroadhesion force in DC voltage
- Open Access
- 29 April 2016
- Published by Springer Nature in ROBOMECH Journal
- Vol. 3 (1) , 1-11
Interaction force estimation on a built-in position sensor for an electrostatic visuo-haptic display
- 29 April 2016
- Published by Springer Nature in ROBOMECH Journal
- Vol. 3 (1) , 1-11
Open AccessInteraction force estimation on a built-in position sensor for an electrostatic visuo-haptic display
- 20 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 9 (3) , 311-322
A Multi-User Surface Visuo-Haptic Display Using Electrostatic Friction Modulation and Capacitive-Type Position Sensing
This paper proposes a visuo-haptic feedback system that can provide haptic feedback to multiple users on an LCD monitor using electrostatic adhesion and built-in capacitive sensors. The prototype system consists of a 40-inch LCD monitor, an ITO electrode sheet arranged on the monitor, and multiple contact pads for electrostatic adhesion. By applying low-frequency haptic voltage and high-frequency sensing voltage to each pad, the system realizes passive haptic feedback, as well as position sensing using the same components. The passive haptic feedback force exceeds 1 N at 300 V$_\mathrm{rms}$ . The performance of the sensing system is investigated in terms of interference, which shows the haptic voltage and existence of multiple pads can affect the sensing and can shift the output by a few millimeters. A pilot application, virtual hockey game, successfully demonstrates the sensing and haptic rendering capability of the proposed system. The effect of the interference on the demonstration is discussed.- 20 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 9 (3) , 311-322
A Multi-User Surface Visuo-Haptic Display Using Electrostatic Friction Modulation and Capacitive-Type Position Sensing
This paper proposes a visuo-haptic feedback system that can provide haptic feedback to multiple users on an LCD monitor using electrostatic adhesion and built-in capacitive sensors. The prototype system consists of a 40-inch LCD monitor, an ITO electrode sheet arranged on the monitor, and multiple contact pads for electrostatic adhesion. By applying low-frequency haptic voltage and high-frequency sensing voltage to each pad, the system realizes passive haptic feedback, as well as position sensing using the same components. The passive haptic feedback force exceeds 1 N at 300 V$_\mathrm{rms}$ . The performance of the sensing system is investigated in terms of interference, which shows the haptic voltage and existence of multiple pads can affect the sensing and can shift the output by a few millimeters. A pilot application, virtual hockey game, successfully demonstrates the sensing and haptic rendering capability of the proposed system. The effect of the interference on the demonstration is discussed.- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 1A1-20a5
Basic Study on Wireless Feeding with LC Resonance for Electrostatic Haptic Feedback
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 1A1-20a5
Basic Study on Wireless Feeding with LC Resonance for Electrostatic Haptic Feedback
- 28 June 2015
- Published by Springer Nature
- p. 183-185
Built-in Capacitive Position Sensing for Multi-user Electrostatic Visuo-haptic Display
- 28 June 2015
- Published by Springer Nature
- p. 183-185
Built-in Capacitive Position Sensing for Multi-user Electrostatic Visuo-haptic Display
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 118 (23247347) , 489-491
Multi-finger surface visuo-haptic rendering using electrostatic stimulation with force-direction sensing gloves
This article describes a new prototype of multi-touch surface visuo-haptic system using in-direct electrostatic stimulation. The prototype consists of a 40-inch large LCD monitor and a pair of operation gloves which are equipped with force generation pads, motion detection markers, and force-direction sensors. A user wearing the gloves can experience multi-finger passive haptic feedback from virtual objects on the monitor with four fingers independently. The article also discusses several rendering algorithms for static objects, textured surfaces, and dynamic objects. Utilizing force direction in haptic rendering, the system can solve the sticky wall problem which is commonly found in passive haptic systems. In rendering of dynamic objects, however, an interesting phenomenon named as “object stiction” was newly found, which would be unique to multi-finger passive haptic displays.
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 118 (23247347) , 489-491
Multi-finger surface visuo-haptic rendering using electrostatic stimulation with force-direction sensing gloves
This article describes a new prototype of multi-touch surface visuo-haptic system using in-direct electrostatic stimulation. The prototype consists of a 40-inch large LCD monitor and a pair of operation gloves which are equipped with force generation pads, motion detection markers, and force-direction sensors. A user wearing the gloves can experience multi-finger passive haptic feedback from virtual objects on the monitor with four fingers independently. The article also discusses several rendering algorithms for static objects, textured surfaces, and dynamic objects. Utilizing force direction in haptic rendering, the system can solve the sticky wall problem which is commonly found in passive haptic systems. In rendering of dynamic objects, however, an interesting phenomenon named as “object stiction” was newly found, which would be unique to multi-finger passive haptic displays.
- 20 April 2013
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 25 (2) , 355-363
A Photoelastic Tactile Sensor to Measure Contact Pressure Distributions on Object Surfaces
Welcome to the official website of Journal of Journal of Robotics and Mechatronics.
- 20 April 2013
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 25 (2) , 355-363
A Photoelastic Tactile Sensor to Measure Contact Pressure Distributions on Object Surfaces
Welcome to the official website of Journal of Journal of Robotics and Mechatronics.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _2A1-B04_1
2A1-B04 Study on Multi-finger Passive Haptic Rendering Using Electrostatic Force(Tactile and Force Sensing (1))
This paper discusses haptic force rendering on a multi-finger electrostatic passive haptic feedback system using a force-direction sensor. The system consists of transparent electrode on an LCD monitor and multiple pads for user's multiple fingers. The system can render haptic feedback force using electrostatically induced friction. However, the previous trial suffered from the sticky-wall problem, which is commonly found in passive haptic systems. In this work, we developed a force-direction sensor that can be integrated into the pad with a diameter of 30 mm and responds to more than 0.2-N pushing force. A wall-rendering experiment shows that the force rendering using the force-direction sensor can reduce stickiness of the virtual wall.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _2A1-B04_1
2A1-B04 Study on Multi-finger Passive Haptic Rendering Using Electrostatic Force(Tactile and Force Sensing (1))
This paper discusses haptic force rendering on a multi-finger electrostatic passive haptic feedback system using a force-direction sensor. The system consists of transparent electrode on an LCD monitor and multiple pads for user's multiple fingers. The system can render haptic feedback force using electrostatically induced friction. However, the previous trial suffered from the sticky-wall problem, which is commonly found in passive haptic systems. In this work, we developed a force-direction sensor that can be integrated into the pad with a diameter of 30 mm and responds to more than 0.2-N pushing force. A wall-rendering experiment shows that the force rendering using the force-direction sensor can reduce stickiness of the virtual wall.