Akio Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akio Yamamoto has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Shunsuke Yoshimoto
Graduate School of Engineering, The University of Osaka, Suita, Japan
13 shared publications - Toshiro Higuchi
The University of Tokyo
7 shared publications - Guangwei Zhang
Department of Human and Engineered Environmental Studies, Graduate School of Frontier Sciences, The University of Tokyo, Chiba 277-8563, Japan
6 shared publications - Taku Nakamura
The University of Tokyo
5 shared publications - Masahiko Gondo
Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
4 shared publications - Norio Yamashita
RIKEN
4 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 10 (4) , 40
The Discrimination Threshold on the Palm for Two Successive Rectangular Stimuli
This study investigates tactile spatial resolution on the palm using two successive rectangular stimuli. Whereas classical tactile resolution studies have focused mainly on point or circular stimulation, less is known about how spatial resolution depends on the placement and geometry of rectangular, device-relevant stimuli. We measured the successive two-stimulus discrimination threshold using three rectangular stimulators across five palm areas aligned along the proximal–distal axis. Participants compared a fixed reference stimulus with a variable comparison stimulus, and the minimum separation at which the two stimuli were perceived as occurring at different locations was recorded as the threshold. The overall average threshold across all experimental conditions was approximately 5.2 mm. The threshold varied systematically across palm regions, being smallest around the palmar digital crease and the base of the fingers. In the central palm, threshold differences were more evident for changes in stimulator width than for changes in stimulator length. These results extend tactile spatial resolution research beyond point stimulation and provide design-relevant guidance for palm-based haptic devices.
- 15 April 2026
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 10 (4) , 40
Open AccessThe Discrimination Threshold on the Palm for Two Successive Rectangular Stimuli
This study investigates tactile spatial resolution on the palm using two successive rectangular stimuli. Whereas classical tactile resolution studies have focused mainly on point or circular stimulation, less is known about how spatial resolution depends on the placement and geometry of rectangular, device-relevant stimuli. We measured the successive two-stimulus discrimination threshold using three rectangular stimulators across five palm areas aligned along the proximal–distal axis. Participants compared a fixed reference stimulus with a variable comparison stimulus, and the minimum separation at which the two stimuli were perceived as occurring at different locations was recorded as the threshold. The overall average threshold across all experimental conditions was approximately 5.2 mm. The threshold varied systematically across palm regions, being smallest around the palmar digital crease and the base of the fingers. In the central palm, threshold differences were more evident for changes in stimulator width than for changes in stimulator length. These results extend tactile spatial resolution research beyond point stimulation and provide design-relevant guidance for palm-based haptic devices.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (2) , 306-315
Psychophysical Effects of Grasping Conditions of a Handheld Device on Vibrotactile Perceptions
Tactile perception varies between individuals and the state of the grasp. To investigate the psychophysical effects on vibrotactile perceptions influenced by grasp type and strength of a handheld device, perceived intensities were tested against various grasp strengths and stimulus levels using 40 and 250 Hz vibrations under power grasp and precision grasp conditions. Grasp strength was measured with a pressure distribution sensor on the cylindrical device capable of presenting vibrations up to approximately 2.0 m/s$^{2}$. The analysis using a physical model supported the measured acceleration characteristics, indicating greater attenuation of low-frequency vibrations due to grasping. The psychophysical experiments indicated that the perceived intensity decreases with grasp strength at 40 Hz vibrations under power grasp, whereas the perceived intensity slightly increases with grasp strength at 250 Hz vibrations under precision grasp. On the other hand, small differences were observed for 40 Hz vibrations during precision grasp and 250 Hz vibrations during power grasp. This highlights the need for compensatory measures in low-frequency vibrations or the use of high-frequency vibrations to achieve consistent vibrotactile feedback in handheld devices across different grasping conditions.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (2) , 306-315
Psychophysical Effects of Grasping Conditions of a Handheld Device on Vibrotactile Perceptions
Tactile perception varies between individuals and the state of the grasp. To investigate the psychophysical effects on vibrotactile perceptions influenced by grasp type and strength of a handheld device, perceived intensities were tested against various grasp strengths and stimulus levels using 40 and 250 Hz vibrations under power grasp and precision grasp conditions. Grasp strength was measured with a pressure distribution sensor on the cylindrical device capable of presenting vibrations up to approximately 2.0 m/s$^{2}$. The analysis using a physical model supported the measured acceleration characteristics, indicating greater attenuation of low-frequency vibrations due to grasping. The psychophysical experiments indicated that the perceived intensity decreases with grasp strength at 40 Hz vibrations under power grasp, whereas the perceived intensity slightly increases with grasp strength at 250 Hz vibrations under precision grasp. On the other hand, small differences were observed for 40 Hz vibrations during precision grasp and 250 Hz vibrations during power grasp. This highlights the need for compensatory measures in low-frequency vibrations or the use of high-frequency vibrations to achieve consistent vibrotactile feedback in handheld devices across different grasping conditions.
- Open Access
- 3 January 2026
- Published by Springer Nature in Journal of Intelligent & Robotic Systems
- Vol. 112 (1)
Simultaneous Control of Attitude and Joint of Bipedal Walking Robot Using Control Moment Gyroscopes
In previous studies, attempts have been made to improve the attitude control of walking robots by adding control moment gyroscopes (CMGs). If CMGs can be used for both attitude control and joint actuation, there is more freedom in distributing torque between the joint actuators and the CMGs. This work proposes distributing multiple CMG units across numerous links to use CMGs simultaneously for attitude control and joint actuation. Focusing on a compass-type walking robot with two links, this paper formulates the relationship between the gimbal speeds of the CMGs and the robot’s attitude and joint angle. Based on the formulation, the steering law determining the speeds of multiple CMGs to realize desired torques is discussed and compared in simulation. The simulation confirmed that the steering law using the SR inverse matrix is effective. With the confirmed control strategy, walking using CMGs is demonstrated in simulation. The result showed that the robot can walk using only CMGs that control both attitude and joint.
- 3 January 2026
- Published by Springer Nature in Journal of Intelligent & Robotic Systems
- Vol. 112 (1)
Open AccessSimultaneous Control of Attitude and Joint of Bipedal Walking Robot Using Control Moment Gyroscopes
In previous studies, attempts have been made to improve the attitude control of walking robots by adding control moment gyroscopes (CMGs). If CMGs can be used for both attitude control and joint actuation, there is more freedom in distributing torque between the joint actuators and the CMGs. This work proposes distributing multiple CMG units across numerous links to use CMGs simultaneously for attitude control and joint actuation. Focusing on a compass-type walking robot with two links, this paper formulates the relationship between the gimbal speeds of the CMGs and the robot’s attitude and joint angle. Based on the formulation, the steering law determining the speeds of multiple CMGs to realize desired torques is discussed and compared in simulation. The simulation confirmed that the steering law using the SR inverse matrix is effective. With the confirmed control strategy, walking using CMGs is demonstrated in simulation. The result showed that the robot can walk using only CMGs that control both attitude and joint.
- Open Access
- 29 November 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 398
Capacitive proximity sensor with an integrated drift compensation electrode
- 29 November 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 398
Open AccessCapacitive proximity sensor with an integrated drift compensation electrode
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 7643-7650
CNN-Based Electromagnetic Tomographic Approach for Simultaneous Tactile Imaging of Pressure and Temperature
This letter introduces a novel electromagnetic tomographic approach for simultaneously imaging contact pressure and temperature using a single sensing material. The proposed sensor features adjustable detection ranges, along with a concise, scalable, and easily fabricated structure. Multi-frequency excitation elicits distinct voltage responses from pressure-induced displacement and temperature-induced conductivity changes, allowing decoupling based on their frequency-dependent patterns. These voltage features are processed by a convolutional neural network to reconstruct pressure and temperature distributions. The model developed using data with six excitation frequencies achieves good reconstruction performance on simulated data. Real-world experiments demonstrate the capability of the approach to coarsely reconstruct square-shaped pressure and temperature distributions, with noticeable residual modality coupling and discrepancies in intensity remaining. These results indicate the feasibility of the proposed approach and suggest its potential for multi-modal tactile imaging.
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 7643-7650
CNN-Based Electromagnetic Tomographic Approach for Simultaneous Tactile Imaging of Pressure and Temperature
This letter introduces a novel electromagnetic tomographic approach for simultaneously imaging contact pressure and temperature using a single sensing material. The proposed sensor features adjustable detection ranges, along with a concise, scalable, and easily fabricated structure. Multi-frequency excitation elicits distinct voltage responses from pressure-induced displacement and temperature-induced conductivity changes, allowing decoupling based on their frequency-dependent patterns. These voltage features are processed by a convolutional neural network to reconstruct pressure and temperature distributions. The model developed using data with six excitation frequencies achieves good reconstruction performance on simulated data. Real-world experiments demonstrate the capability of the approach to coarsely reconstruct square-shaped pressure and temperature distributions, with noticeable residual modality coupling and discrepancies in intensity remaining. These results indicate the feasibility of the proposed approach and suggest its potential for multi-modal tactile imaging.
- Open Access
- 9 May 2025
- Published by Elsevier in Additive Manufacturing
- Vol. 106
Advances in 3D printed electromechanical sensors: Performance comparison, trends, and future directions
- 9 May 2025
- Published by Elsevier in Additive Manufacturing
- Vol. 106
Open AccessAdvances in 3D printed electromechanical sensors: Performance comparison, trends, and future directions
- Open Access
An Arch-Shaped Electrostatic Actuator for Multi-Legged Locomotion
A simple actuator to create non-reciprocal leg motion is imperative in realizing a multi-legged micro-locomotion mechanism. This work focuses on an arch-shaped electrostatic actuator as a candidate actuator, and it proposes the operation protocol to realize a non-reciprocal trajectory. The actuator consists of two hard and flexible sheets and a leg attached to the flexible sheet. The flexible sheet is deformed through an electrostatic zipping motion that changes the height and/or angle of the attached leg. The fabricated prototype weighed 0.1 g and swung about 15 degrees with the applied voltage of 1000 V. The swinging force exceeded 5 mN, five times the gravitational force on the actuator’s weight. Large performance deviations among prototypes were found, which were due to the manual fabrication process and the varying conditions of the silicone oil injected into the gap. The trajectory measurement showed that the leg tip moved along a non-reciprocal trajectory with a vertical shift of about 0.3 mm between the forward and backward swings. The prototype locomotion mechanism using four actuators successfully demonstrated forward and backward motions with the non-reciprocal swing motion of the four legs. The observed locomotion speed was about 0.3 mm/s. Although the speed was limited, the results showed the potential of the actuator for use in multi-legged micro-locomotion systems.
Open AccessAn Arch-Shaped Electrostatic Actuator for Multi-Legged Locomotion
A simple actuator to create non-reciprocal leg motion is imperative in realizing a multi-legged micro-locomotion mechanism. This work focuses on an arch-shaped electrostatic actuator as a candidate actuator, and it proposes the operation protocol to realize a non-reciprocal trajectory. The actuator consists of two hard and flexible sheets and a leg attached to the flexible sheet. The flexible sheet is deformed through an electrostatic zipping motion that changes the height and/or angle of the attached leg. The fabricated prototype weighed 0.1 g and swung about 15 degrees with the applied voltage of 1000 V. The swinging force exceeded 5 mN, five times the gravitational force on the actuator’s weight. Large performance deviations among prototypes were found, which were due to the manual fabrication process and the varying conditions of the silicone oil injected into the gap. The trajectory measurement showed that the leg tip moved along a non-reciprocal trajectory with a vertical shift of about 0.3 mm between the forward and backward swings. The prototype locomotion mechanism using four actuators successfully demonstrated forward and backward motions with the non-reciprocal swing motion of the four legs. The observed locomotion speed was about 0.3 mm/s. Although the speed was limited, the results showed the potential of the actuator for use in multi-legged micro-locomotion systems.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 3184-3192
Force Control Using Internal Spring in Electrostatic Linear Motors and Switching Between Position and Force Control
This article proposes a method for controlling force and position in a synchronous direct-drive electrostatic linear motor. Using a spring-like behavior of synchronous motors, the proposed controller regulates the contact force in a manner similar to that of series elastic actuators. Discussions regarding similarities and differences between series elastic actuators and the proposed method imply that their dynamic behaviors are different. The proposed controller consists of a force control part and a position control part, one of which is automatically selected based on the operating conditions. The position and force controllers each independently command the velocity based on the position or force error. The lower of the two velocities is selected, allowing a smooth automatic transition between the two control modes. Based on the selected velocity, the driving signal is calculated under the assumption of synchronous operation and fed to the actuator. The proposed control method is simulated and experiments are performed using prototype electrostatic linear motors. The experimental results confirm the smooth transition between the position and force control modes, as well as the good controllability of the contact force.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 3184-3192
Force Control Using Internal Spring in Electrostatic Linear Motors and Switching Between Position and Force Control
This article proposes a method for controlling force and position in a synchronous direct-drive electrostatic linear motor. Using a spring-like behavior of synchronous motors, the proposed controller regulates the contact force in a manner similar to that of series elastic actuators. Discussions regarding similarities and differences between series elastic actuators and the proposed method imply that their dynamic behaviors are different. The proposed controller consists of a force control part and a position control part, one of which is automatically selected based on the operating conditions. The position and force controllers each independently command the velocity based on the position or force error. The lower of the two velocities is selected, allowing a smooth automatic transition between the two control modes. Based on the selected velocity, the driving signal is calculated under the assumption of synchronous operation and fed to the actuator. The proposed control method is simulated and experiments are performed using prototype electrostatic linear motors. The experimental results confirm the smooth transition between the position and force control modes, as well as the good controllability of the contact force.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (12) , 16783-16791
Design of a High-Performance Tomographic Tactile Sensor by Manipulating the Detector Conductivity
Recent advancements in soft robots, human–machine interfaces, and wearable electronics have led to an increased demand for high-performance soft tactile sensors. Tomographic tactile sensor based on resistive coupling is a novel contact pressure imaging method that allows the use of an arbitrary conductive material in a detector. However, the influence of material properties on the sensing performance remains unclear, and the efficient and appropriate selection of materials is difficult. In this study, the relationship between the conductivity distribution of the material used as a detector and the sensing performance including sensitivity, force range, spatial resolution, and position accuracy is clarified to develop high-performance tomographic tactile sensors for specific purposes. The performance maps reveal that a material with a conductivity of approximately 0.2 S/m can serve as an effective detector for touch interactions involving a force range of several Newtons. Additionally, incorporating gradient conductivity in the cross section of the detector and multilayer conductive porous media with anisotropic conductive bonding can help expand the design flexibility for enhanced performance. Based on these findings, various tomographic tactile sensors for soft grippers, tangible input interfaces, flexible touch displays, and wearable electronics are demonstrated by using a conductive porous media.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (12) , 16783-16791
Design of a High-Performance Tomographic Tactile Sensor by Manipulating the Detector Conductivity
Recent advancements in soft robots, human–machine interfaces, and wearable electronics have led to an increased demand for high-performance soft tactile sensors. Tomographic tactile sensor based on resistive coupling is a novel contact pressure imaging method that allows the use of an arbitrary conductive material in a detector. However, the influence of material properties on the sensing performance remains unclear, and the efficient and appropriate selection of materials is difficult. In this study, the relationship between the conductivity distribution of the material used as a detector and the sensing performance including sensitivity, force range, spatial resolution, and position accuracy is clarified to develop high-performance tomographic tactile sensors for specific purposes. The performance maps reveal that a material with a conductivity of approximately 0.2 S/m can serve as an effective detector for touch interactions involving a force range of several Newtons. Additionally, incorporating gradient conductivity in the cross section of the detector and multilayer conductive porous media with anisotropic conductive bonding can help expand the design flexibility for enhanced performance. Based on these findings, various tomographic tactile sensors for soft grippers, tangible input interfaces, flexible touch displays, and wearable electronics are demonstrated by using a conductive porous media.
- 24 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (7) , 6809-6818
Position Self-Sensing for Electrostatic Motors Under Amplitude-Modulated AC Operation
In a previous study, displacement self-sensing using driving current has been proposed for a synchronous-type macroscale electrostatic motor under alternating current (ac) operation; however, it cannot be used in practice due to its low noise immunity. This work improves the position self-sensing method for electrostatic motors under amplitude-modulated ac operation, in which the driving signal is amplitude-modulated using a high-frequency carrier signal. The modulation transfers the signal frequency to a higher region, which results in a much larger driving current and high noise immunity. In the modified self-sensing method discussed in this work, the high-frequency signal is demodulated, and then the slider displacement information is distilled through Clarke and Park transformations. The systematic error of the method is discussed to show that it depends on the performance of the cutoff frequency of the low-pass filter (LPF) in demodulation. Theoretical analysis shows that the accuracy is possibly improved by decreasing the cutoff frequency of the LPF. Simulation results confirmed that the noise immunity of this modified self-sensing method is much higher than that of the previous method, which means it can be used in practice. Verification experiments have been done under various conditions by using prototype electrostatic motors, which validated that the modified self-sensing method realizes a high accuracy/resolution of around $20\,\mu$ m in practical situations.
- 24 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (7) , 6809-6818
Position Self-Sensing for Electrostatic Motors Under Amplitude-Modulated AC Operation
In a previous study, displacement self-sensing using driving current has been proposed for a synchronous-type macroscale electrostatic motor under alternating current (ac) operation; however, it cannot be used in practice due to its low noise immunity. This work improves the position self-sensing method for electrostatic motors under amplitude-modulated ac operation, in which the driving signal is amplitude-modulated using a high-frequency carrier signal. The modulation transfers the signal frequency to a higher region, which results in a much larger driving current and high noise immunity. In the modified self-sensing method discussed in this work, the high-frequency signal is demodulated, and then the slider displacement information is distilled through Clarke and Park transformations. The systematic error of the method is discussed to show that it depends on the performance of the cutoff frequency of the low-pass filter (LPF) in demodulation. Theoretical analysis shows that the accuracy is possibly improved by decreasing the cutoff frequency of the LPF. Simulation results confirmed that the noise immunity of this modified self-sensing method is much higher than that of the previous method, which means it can be used in practice. Verification experiments have been done under various conditions by using prototype electrostatic motors, which validated that the modified self-sensing method realizes a high accuracy/resolution of around $20\,\mu$ m in practical situations.