JBJordi Borst

Jordi Borst

*This is an algorithmically generated author record based on publicly available information.

Jordi Borst has a total of 136 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accuracy of CT Angiography for Differentiating Pseudo-Occlusion from True Occlusion or High-Grade Stenosis of the Extracranial ICA in Acute Ischemic Stroke: A Retrospective MR CLEAN Substudy

    by M. Kappelhof, H.A. Marquering, O.A. Berkhemer, J. Borst, A. van der Lugt, W.H. van Zwam, J.A. Vos, G. Lycklama À Nijeholt, C.B.L.M. Majoie, B.J. Emmer

    BACKGROUND AND PURPOSE: The absence of opacification on CTA in the extracranial ICA in acute ischemic stroke may be caused by atherosclerotic occlusion, dissection, or pseudo-occlusion. The latter is explained by sluggish or stagnant flow in a patent artery caused by a distal intracranial occlusion. This study aimed to explore the accuracy of CTA for differentiating pseudo-occlusion from true occlusion of the extracranial ICA. MATERIALS AND METHODS: All patients from the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN) with an apparent ICA occlusion on CTA and available DSA images were included. Two independent observers classified CTA images as atherosclerotic cause (occlusion/high-grade stenosis), dissection, or suspected pseudo-occlusion. Pseudo-occlusion was suspected if CTA showed a gradual contrast decline located above the level of the carotid bulb, especially in the presence of an occluded intracranial ICA bifurcation (T-occlusion). DSA images, classified into the same 3 categories, were used as the criterion standard. RESULTS: In 108 of 476 patients (23%), CTA showed an apparent extracranial carotid occlusion. DSA was available in 46 of these, showing an atherosclerotic cause in 13 (28%), dissection in 16 (35%), and pseudo-occlusion in 17 (37%). The sensitivity for detecting pseudo-occlusion on CTA was 82% (95% CI, 57–96) for both observers; specificity was 76% (95% CI, 56–90) and 86% (95% CI, 68–96) for observers 1 and 2, respectively. The κ value for interobserver agreement was .77, indicating substantial agreement. T-occlusions were more frequent in pseudo- than true occlusions (82% versus 21%, P < .001). CONCLUSIONS: On CTA, extracranial ICA pseudo-occlusions can be differentiated from true carotid occlusions.


  • Automated Ventricular System Segmentation in CT Images of Deformed Brains Due to Ischemic and Subarachnoid Hemorrhagic Stroke

    by E. Ferdian, A. M. Boers, L. F. Beenen, B. M. Cornelissen, I. G. Jansen, K. M. Treurniet, J. Borst, C. B. Majoie, H. A. Marquering


  • Open Access

    Value of Thrombus CT Characteristics in Patients with Acute Ischemic Stroke

    by J. Borst, O.A. Berkhemer, E.M.M. Santos, A.J. Yoo, M. Den Blanken, Y.B.W.E.M. Roos, E. van Bavel, W.H. van Zwam, R.J. van Oostenbrugge, H.F. Lingsma, et al.

    BACKGROUND AND PURPOSE: Thrombus CT characteristics might be useful for patient selection for intra-arterial treatment. Our objective was to study the association of thrombus CT characteristics with outcome and treatment effect in patients with acute ischemic stroke. MATERIALS AND METHODS: We included 199 patients for whom thin-section NCCT and CTA within 30 minutes from each other were available in the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute ischemic stroke in the Netherlands (MR CLEAN) study. We assessed the following thrombus characteristics: location, distance from ICA terminus to thrombus, length, volume, absolute and relative density on NCCT, and perviousness. Associations of thrombus characteristics with outcome were estimated with univariable and multivariable ordinal logistic regression as an OR for a shift toward better outcome on the mRS. Interaction terms were used to investigate treatment-effect modification by thrombus characteristics. RESULTS: In univariate analysis, only the distance from the ICA terminus to the thrombus, length of >8 mm, and perviousness were associated with functional outcome. Relative thrombus density on CTA was independently associated with functional outcome with an adjusted common OR of 1.21 per 10% (95% CI, 1.02–1.43; P = .029). There was no treatment-effect modification by any of the thrombus CT characteristics. CONCLUSIONS: In our study on patients with large-vessel occlusion of the anterior circulation, CT thrombus characteristics appear useful for predicting functional outcome. However, in our study cohort, the effect of intra-arterial treatment was independent of the thrombus CT characteristics. Therefore, no arguments were provided to select patients for intra-arterial treatment using thrombus CT characteristics.


  • Value of Computed Tomographic Perfusion–Based Patient Selection for Intra-Arterial Acute Ischemic Stroke Treatment

    by Jordi Borst, Olvert A. Berkhemer, Yvo B.W.E.M. Roos, Ed van Bavel, Wim H. van Zwam, Robert J. van Oostenbrugge, Marianne A.A. van Walderveen, Hester F. Lingsma, Aad van der Lugt, Diederik W.J. Dippel, et al.

    Background and Purpose—: The utility of computed tomographic perfusion (CTP)–based patient selection for intra-arterial treatment of acute ischemic stroke has not been proven in randomized trials and requires further study in a cohort that was not selected based on CTP. Our objective was to study the relationship between CTP-derived parameters and outcome and treatment effect in patients with acute ischemic stroke because of a proximal intracranial arterial occlusion. Methods—: We included 175 patients who underwent CTP in the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in The Netherlands (MR CLEAN). Association of CTP-derived parameters (ischemic-core volume, penumbra volume, and percentage ischemic core) with outcome was estimated with multivariable ordinal logistic regression as an adjusted odds ratio for a shift in the direction of a better outcome on the modified Rankin Scale. Interaction between CTP-derived parameters and treatment effect was determined using multivariable ordinal logistic regression. Interaction with treatment effect was also tested for mismatch (core 1.2; penumbra core >10 mL). Results—: The adjusted odds ratio for improved functional outcome for ischemic core, percentage ischemic core, and penumbra were 0.79 per 10 mL (95% confidence interval: 0.71–0.89; P P =0.002), and 0.97 per 10 mL (96% confidence interval: 0.92–1.01; P =0.15), respectively. No significant interaction between any of the CTP-derived parameters and treatment effect was observed. We observed no significant interaction between mismatch and treatment effect. Conclusions—: CTP seems useful for predicting functional outcome, but cannot reliably identify patients who will not benefit from intra-arterial therapy.


  • Open Access

    Diagnostic Accuracy of 4 Commercially Available Semiautomatic Packages for Carotid Artery Stenosis Measurement on CTA

    by J. Borst, H.A. Marquering, M. Kappelhof, T. Zadi, A.C. van Dijk, P.J. Nederkoorn, R. van Den Berg, A. van der Lugt, C.B.L.M. Majoie

    BACKGROUND AND PURPOSE: Semiautomatic measurement of ICA stenosis potentially increases observer reproducibility. In this study, we assessed the diagnostic accuracy and interobserver reproducibility of a commercially available semiautomatic ICA stenosis measurement on CTA and estimated the agreement among different software packages. MATERIALS AND METHODS: We analyzed 141 arteries from 90 patients with TIA or ischemic stroke. Manual stenosis measurements were performed by 2 neuroradiologists. Semiautomatic measurements by using 4 methods (3mensio and comparable software from Philips, TeraRecon, and Siemens) were performed by 2 observers. Diagnostic accuracy was estimated by comparing semiautomatic with manual measurements. Interobserver reproducibility and agreement between different packages was assessed by calculation of the intraclass correlation coefficient and Bland-Altman 95% limits of agreement. False-negative classifications were retrospectively inspected by a neuroradiologist. RESULTS: There was no significant difference in the diagnostic performance of the 4 semiautomatic methods. The sensitivity for detecting ≥50% and ≥70% degree of stenosis was between 76% and 82% and 46% and 62%, respectively. Specificity and overall diagnostic accuracy were between 92% and 97% and 85% and 90%, respectively. The interobserver intraclass correlation coefficient was between 0.83 and 0.96 for semiautomatic measurements and 0.81 for manual measurement. The limits of agreement between each pair of semiautomatic packages ranged from −18−24% to −33%–31%. False-negative classifications were caused by ulcerative plaques and observer variation in stenosis and reference measurements. CONCLUSIONS: Semiautomatic methods have a low-to-good sensitivity and a good specificity and overall diagnostic accuracy. The high interobserver reproducibility makes semiautomatic stenosis measurement valuable for clinical practice, but semiautomatic measurements should be checked by an experienced radiologist.


  • Open Access

    Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion

    by Jordi Borst, Henk A. Marquering, Ludo F. M. Beenen, Olvert A. Berkhemer, Jan Willem Dankbaar, Alan J. Riordan, Charles B. L. M. Majoie, on behalf of the MR CLEAN investigators

    It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice. The purpose of this study was to investigate the occurrence of time attenuation curve truncation in 48 seconds CT Perfusion acquisition and to quantify its effect on ischemic core and penumbra estimation in patients with acute ischemic stroke due to a proximal intracranial arterial occlusion of the anterior circulation. We analyzed CT Perfusion data with 48 seconds and extended acquisition times, assuring full time attenuation curves, of 36 patients. Time attenuation curves were classified as complete or truncated. Ischemic core and penumbra volumes resulting from both data sets were compared by median paired differences and interquartile ranges. Controlled experiments were performed using a digital CT Perfusion phantom to investigate the effect of time attenuation curve truncation on ischemic core and penumbra estimation. In 48 seconds acquisition data, truncation was observed in 24 (67%) cases for the time attenuation curves in the ischemic core, in 2 cases for the arterial input function and in 5 cases for the venous output function. Analysis of extended data resulted in smaller ischemic cores and larger penumbras with a median difference of 13.2 (IQR: 4.3–26.0)ml (P<0.001) and; 12.4 (IQR: 4.1–25.7)ml (P<0.001), respectively. The phantom data showed increasing ischemic core overestimation with increasing tissue time attenuation curve truncation. Truncation is common in patients with large vessel occlusion and results in repartitioning of the area of hypoperfusion into larger ischemic core and smaller penumbra estimations. Phantom experiments confirmed that truncation results in overestimation of the ischemic core.