Weilong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weilong Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Lin Lu
Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
9 shared publications - Hongxing Yang
The Hong Kong Polytechnic University
7 shared publications - Xi Chen
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China
6 shared publications - Jinqing Peng
College of Civil Engineering, Hunan University, Changsha, Hunan, China
2 shared publications Junchao Huang
2 shared publicationsXingyu Xu
2 shared publications
Latest Publications
- 18 June 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (10) , 1394-1405
Year-round-based optimization of high‐low control in the regenerative indirect evaporative cooler (RIEC)
The performance of regenerative indirect evaporative cooler (RIEC) highly depends on ambient temperature and humidity. To maintain indoor thermal comfort, proper control strategy is essential. Previous research indicates that high-low (H-L) control by using multi-speed technology, is superior to the conventional on-off control in terms of energy consumption and thermal comfort. Under H-L control, fan switches between a high speed and a low speed. The high speed is determined by the peak load. However, the selection of low speed involves with a great sense of subjectivity. Therefore, the influence of low speed on system performance is comprehensively investigated and optimal low speed to high speed ratio (L/H) is determined. An optimization method is proposed by considering annual energy consumption, predicted mean vote, temperature fluctuation and switch frequency of fan speed. Case studies have been conducted in some typical hot and arid regions. The results show that better thermal comfort can be provided under smaller L/H from the aspects of high control precision and small temperature fluctuation. The switch frequency of fan speed and annual energy consumption firstly decrease and then increase with the increment of L/H. H. The optimal L/H is between 0.2 to 0.3 from year-around perspective and comprehensive consideration.
- 18 June 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (10) , 1394-1405
Year-round-based optimization of high‐low control in the regenerative indirect evaporative cooler (RIEC)
The performance of regenerative indirect evaporative cooler (RIEC) highly depends on ambient temperature and humidity. To maintain indoor thermal comfort, proper control strategy is essential. Previous research indicates that high-low (H-L) control by using multi-speed technology, is superior to the conventional on-off control in terms of energy consumption and thermal comfort. Under H-L control, fan switches between a high speed and a low speed. The high speed is determined by the peak load. However, the selection of low speed involves with a great sense of subjectivity. Therefore, the influence of low speed on system performance is comprehensively investigated and optimal low speed to high speed ratio (L/H) is determined. An optimization method is proposed by considering annual energy consumption, predicted mean vote, temperature fluctuation and switch frequency of fan speed. Case studies have been conducted in some typical hot and arid regions. The results show that better thermal comfort can be provided under smaller L/H from the aspects of high control precision and small temperature fluctuation. The switch frequency of fan speed and annual energy consumption firstly decrease and then increase with the increment of L/H. H. The optimal L/H is between 0.2 to 0.3 from year-around perspective and comprehensive consideration.
- 1 April 2019
- Published by Elsevier in Renewable Energy
- Vol. 134, 818-827
Overall energy assessment of semi-transparent photovoltaic insulated glass units for building integration under different climate conditions
- 1 April 2019
- Published by Elsevier in Renewable Energy
- Vol. 134, 818-827
Overall energy assessment of semi-transparent photovoltaic insulated glass units for building integration under different climate conditions
- Open Access
- 1 March 2019
- Published by SDEWES Centre in Journal of Sustainable Development of Energy, Water and Environment Systems
- Vol. 7 (1) , 1-12
Overall Energy Performance Assessment of a New Heat Blocking Coating
In subtropical Hong Kong, clear glass is normally used as the translucent material for external windows of residential buildings, but it has poor heat insulation performance especially the tremendous solar heat gain in summer. To improve the thermal performance of conventional clear glass, a new heat blocking coating was developed. The coating can effectively absorb the near infrared radiation, so it can reduce the solar heat gain and therefore the energy use from airconditioning systems. In this paper, the preparation of the heat blocking coating was firstly introduced. Then the optical and thermal properties of different types of window glazing were tested in the laboratory. Based on the experimental data, a combined daylight, thermal environment and building energy numerical model of a public rental housing was established to fully simulate the performance of different types of windows glazing. The results indicated that the heat blocking coating can reduce about 275.4 kWh (14.4%) electricity use per year compared to conventional clear window.
- 1 March 2019
- Published by SDEWES Centre in Journal of Sustainable Development of Energy, Water and Environment Systems
- Vol. 7 (1) , 1-12
Open AccessOverall Energy Performance Assessment of a New Heat Blocking Coating
In subtropical Hong Kong, clear glass is normally used as the translucent material for external windows of residential buildings, but it has poor heat insulation performance especially the tremendous solar heat gain in summer. To improve the thermal performance of conventional clear glass, a new heat blocking coating was developed. The coating can effectively absorb the near infrared radiation, so it can reduce the solar heat gain and therefore the energy use from airconditioning systems. In this paper, the preparation of the heat blocking coating was firstly introduced. Then the optical and thermal properties of different types of window glazing were tested in the laboratory. Based on the experimental data, a combined daylight, thermal environment and building energy numerical model of a public rental housing was established to fully simulate the performance of different types of windows glazing. The results indicated that the heat blocking coating can reduce about 275.4 kWh (14.4%) electricity use per year compared to conventional clear window.
- Open Access
- 1 February 2019
- Published by Elsevier in Energy Procedia
- Vol. 158, 1080-1085
Thermal and daylighting performance of glass window using a newly developed transparent heat insulated coating
- 1 February 2019
- Published by Elsevier in Energy Procedia
- Vol. 158, 1080-1085
Open AccessThermal and daylighting performance of glass window using a newly developed transparent heat insulated coating
- Open Access
- 1 February 2019
- Published by Elsevier in Energy Procedia
- Vol. 158, 2469-2474
Exploring the optimization potential of thermal and power performance for a low-energy high-rise building
- 1 February 2019
- Published by Elsevier in Energy Procedia
- Vol. 158, 2469-2474
Open AccessExploring the optimization potential of thermal and power performance for a low-energy high-rise building
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 229, 1048-1060
Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 229, 1048-1060
Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems
- 10 August 2018
- Published by Springer Nature in Building Simulation
- Vol. 12 (1) , 29-39
Investigation on the energy performance of a novel semi-transparent BIPV system integrated with vacuum glazing
- 10 August 2018
- Published by Springer Nature in Building Simulation
- Vol. 12 (1) , 29-39
Investigation on the energy performance of a novel semi-transparent BIPV system integrated with vacuum glazing
- 1 February 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 82, 1712-1725
Simulation-based approach to optimize passively designed buildings: A case study on a typical architectural form in hot and humid climates
- 1 February 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 82, 1712-1725
Simulation-based approach to optimize passively designed buildings: A case study on a typical architectural form in hot and humid climates
- 1 August 2017
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 168, 119-129
Preparation and overall energy performance assessment of wide waveband two-component transparent NIR shielding coatings
- 1 August 2017
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 168, 119-129
Preparation and overall energy performance assessment of wide waveband two-component transparent NIR shielding coatings