Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed S. Abd-Elhady has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Experimental Investigation of COP Enhancement in a Heated Vapor Compression Cycle Using an Intermediate Flash Tank

    by Yassin Elmahdy, Mohamed S. Abd-Elhady, Emanoeel Bishara, Mahmoud M. E. El-Hagar, Sife A. Ahmed

    The goal of this research is to minimize the electrical energy consumption and emissions of the refrigeration cycle as a step towards sustainable refrigeration. The Vapor Compression Cycle (VCC) relies mainly on electrical energy; however, the developed Heated Vapor Compression Cycle (HVCC) relies on electrical energy as well as solar energy, which lowers our dependence on electrical energy and improves environmental sustainability. The objective of this research is to improve the coefficient of performance (COP) of the HVCC in comparison to the VCC by adding an intermediate flash tank to the capillary tube. The intermediate flash tank converts the wet refrigerant into saturated liquid, which decreases the quality of the refrigerant at the entrance of the evaporator and consequently improves the cooling potential, i.e., the cooling power. The proposed concept was examined for four different refrigerants, i.e., R502, R407c, R22 and R410a, and at four different intermediate pressures. Also, the influence of the heating temperature on the HVCC as a function of intermediate pressure was examined. It was found that, for all the examined refrigerants, decreasing the intermediate flash tank pressure improves the COP of the cycle. The HVCC operating with R410a has the highest COP, i.e., 6.2, at an intermediate flash tank pressure of 165 psi and a heating temperature of 100 °C, while R407c has the highest COP of 4.8 when compared with R502 and R22 when operating under the same pressures. Adding a flash tank to the HVCC operating with refrigerant R410a can improve the COP of the cycle by more than 40% and by more than 25% in the case of refrigerant R407c. Such improvement in the performance of the cycle reduces electrical energy consumption and improves the environmental sustainability of the cycle.

  • Open Access

    Influence of an Air Slit in Dust Shields on Accumulation of Dust over PV Panels

    by Ahmed M. Gobran, Mohamed S. Abd-Elhady, Hamdy A. Kandil

    Dust accumulation on Photovoltaic (PV) panels represents a major challenge for the operation of panels. There are several passive dust mitigation techniques, such as using a dust shield whose performance has been enhanced by integrating it with an air nozzle. The air exiting the nozzle acts as an air barrier that obstructs the approach of dust particles to the panel’s surface. The objective of this study is to minimize dust accumulation over PV panels by adding slits within the dust shield. The function of the slit is to induce air drafts that can sweep dust away from the surface of the PV panel. Numerical simulations are performed to determine the influence of the slit size and position on dust mitigation. It has been found that there is a critical slit size, such that the deposition of particles for slits of sizes smaller or larger than that size decreases. Increasing the slit size increases dust deposition until a certain limit, i.e., the critical size, and that is due to the Coanda effect that keeps the flow intact with the shield until it reaches the panels’ surface, which increases the dust accumulation rate. On the other hand, increasing the slit size above the critical size decreases the dust deposition due to the change from a non-inertial flow to an inertial flow, which diverts the incoming particles from reaching the panels’ surface. Also, it has been found that keeping the slit location away from the panel’s surface decreases the accumulation of dust over the panels’ surface. Therefore, based on the performed simulations, the slit size should always be either greater or smaller than the critical size and as far as possible from the panel’s surface to minimize dust accumulation over PV panels.


  • Open Access

    Enhancing the efficiency of solar-powered water distillation units by utilization of waste heat

    by S. P. Reddy, M. S. Abd-Elhady, N. Mansour, D. Dahlhaus

    Thermal water desalination is based on the evaporation and condensation of water, and such a process consumes a lot of energy, which lowers the economy of the process for commercial water desalination. The objective of this research is to improve the desalination energy efficiency of a novel domestic water desalination unit, which is based on thermal desalination, and this is done via utilization of the waste heat in the generated steam and reducing the operating costs. The distillation process begins with solar-powered evaporation of the salty water in the evaporator, followed by condensation of the generated water vapor coming from the evaporator over the cross-flow heat exchangers located in the condenser, which preheats the incoming saline water from the saltwater tank before it enters the evaporator. To assess the system's performance, comprehensive measurements are taken, including the electrical energy output from the photovoltaic (PV) panels and the volume of the output distilled water. Notably, the energy efficiency of the distillation is defined as the ratio of the heat energy gained by the distilled water, i.e. collected at the end of the day, to the electrical energy input to the electric heater, and it is found to be, on average, 82%.


  • Open Access

    A new cleaning method for solar panels inspired from the natural vibrations of tree branches and leaves

    by M. S. Abd-Elhady, Adil Rana, M. A. Elsebaaie, H. A. Kandil

    Photovoltaic (PV) panels are similar in many aspects to the leaves of trees, both are standing in the Sun to capture the sunlight, however, PV panels get soiled especially in desert areas, while the leaves remain clean to a very good extent. The question is, why leaves remain clean while PV panels get soiled quite easily? The leaves are hanging on the stem of trees and these stems are flexible to motion, such that if the wind blows in any direction over the stem it vibrates allowing any deposited particle to fall off the surface. The objective of this research is to develop a fixation method for PV panels similar to the stems of trees, such that the panel can vibrate as the wind blows in order to minimize dust accumulation. Different fixation methods for the PV panel are designed, and the air flow around the panel is simulated using the CFD package Ansys Fluent. It has been found that a PV panel pivoted at its lower edge, such that it can revolve around the lower edge, together with a vertical wind shield attached to its upper edge and a spring attached at the middle of its backside has the largest vibration amplitude due to the applied wind compared to the other designs. Experiments have been done to infer the influence of the new fixation method of the PV panel on dust accumulation over the panel. After 6 weeks of operation, it has been found that the efficiency of the PV panel that is flexibly fixed has dropped by only 5%, while the efficiency of the panel that is rigidly fixed has dropped by 25%. It can be concluded that a PV panel operating a light post should be fixed on a flexible base that allows the panel to vibrate as the wind blows over it in order to mitigate dust.


  • Open Access

    Examination of the parameters effect on Al-Cu FSW welded butt joints using formability consent

    by Hammad T. Elmetwally, Hani N. SaadAllah, M.S. Abd-Elhady, Ragab K. Abdel-Magied, Ayman Ali Abd-Eltwab

    In most applications, joining aluminum to copper using friction stir welding (FSW) is a primary manufacturing process followed by secondary forming processes. The aim of this study is to investigate the effect of FSW process parameters (speed and feed rate) on the formability of Al-Cu joints. Aluminum and copper blanks were welded at three different rotational speeds, i.e., 910, 1280, and 1700 rpm, and three different feed rates, i.e., 16, 29, and 44 mm/min. The base metals used in this study were aluminum (Al-1050) and copper in two states, i.e., as received and annealed. The mechanical properties of the base metals and the produced compounds were evaluated by tensile and hardness tests. The aluminum-copper joints were drawn into flangeless U-shape and cup shape using FSW to examine the formability of the joints. The maximum tensile load, punch load, and forming index were obtained when Al was at 1700 rpm and 16 mm/min, i.e., h. The welding was performed with annealed copper at the highest rotational speed and lowest feed rate due to work hardening of the joint. However, the ductility was highest at 1280 rpm and 44 mm/min, i.e., at medium rotation and highest travel speed. It can be depicted that when the FSW Al-Cu joint is further used in the forming process, moderate rotation and high feed speed should be adopted for welding to avoid work hardening and improve the ductility of the joint.


  • Open Access

    Water desalination using PV panels based on boiling and evaporation

    by John Iskander, Othman Shihimi, Nahed El Mahallawy, M. S. Abd-Elhady

    The annual share of water in Egypt has decreased to approximately 500 m3 per capita, while the annual water scarcity level is 1000 m3 per capita, which indicates that Egyptians are at a high risk of living. A domestic desalination unit based on solar energy was designed, built, and tested to solve this problem in remote areas that do not have access to fresh water or electricity but have access to salty water. The desalination unit has a new design that depends on boiling salty water using photovoltaic solar cells and then condensing the water vapor through a heat exchanger to obtain freshwater. This new design has not been implemented before and can compete with the solar stills used for domestic applications. The output of the developed unit was compared to those of passive and active solar stills that have been developed and built. The new desalination design produced almost the same amount of daily fresh water, 4 Liter/day, compared to the other solar stills (2–4.75 Liter/day), but the cost per unit volume of the new design, 31 $/m3, is less by 30% compared to the best performing solar still, 44.55 $/m3, which produces only 2 Liter/day. The price of the distilled water produced by the new design was 75% lower than the market price at the time of conducting the experiments. Converting a Solar still from a passive system, that is, operating only during sunlight, to an active system operating day and night improves the water productivity rate. However, this is not feasible because of the added accessories that increase the initial cost, consequently increasing the cost of desalination.


  • Open Access

    Catalytic pyrolysis of waste polypropylene using low-cost natural catalysts

    by A. I. Eldahshory, Karim Emara, M. S. Abd-Elhady, M. A. Ismail

    The objective of this research is to produce oil from the catalytic pyrolysis of waste polypropylene (WPP) using a low-cost natural catalyst. Three natural catalysts were examined, i.e. Kaolin, Hematite, and white sand. Different catalyst-to-plastic ratios were examined, i.e. 1:1, 1:2, 1:4, 1:6, and 1:8. The utilized catalysts were elementally analyzed using the XRF analysis and the surface area was analyzed by the BET multi-point method. The WPP thermal degradation behavior was investigated by the thermogravimetric analysis (TGA), then the generated liquid oil was analyzed using the gas chromatography-mass spectrometry (GC–MS) and the differential scanning calorimetry (DSC). Thermal cracking without a catalyst produced a yield of 70 wt% of liquid oil, and the maximum oil yield in case of using Hematite and white sand as a catalysts were 70 wt% and 68 wt%, respectively. However, the ratio of 1:2 of the Kaolin to the WPP produced the highest oil yield of 80.75 wt%, and the ratio of 1:8 of the white sand to the WPP produced the highest gas yield, i.e. 44 wt%. Using Kaolin in the catalytic pyrolysis of WPP produced oil with the lowest percentage of heavy oils, i.e. 25.98%, and the highest percentage of light oils, which is 25.37%, when compared to other catalysts such as Hematite and white sand. Kaolin has the lowest cost of oil production compared to Hematite and white sand, which is 0.28 $/kg of oil. Kaolin is an economical catalyst that improves the quality, as well as the quantity of the produced oil in comparison to Hematite, white sand and the non-catalytic case.


  • Influence of the hot water mass flow rate on heating of radiant floors of green buildings

    by Sarah B Fahmy, M Zamzam, T Khalil, Yasmine Abdalla, Thomas Loeffler, Sa Ahmed, Abd- Elhady

    The objective of the research is to improve space heating of green buildings by examining experimentally the influence of the heating medium mass flow rate on thermal performance. A green building was built in Cairo, Egypt, that consists of two similar rooms: one is the heated room and the other is a reference for comparison. A photovoltaic thermal (PV/T) collector is used to heat up water in a storage tank, and the hot water in the tank is circulated in the radiant floor of the examined green building. The hot water mass flow rate was varied between 0.04 and 0.08 kg/s. It was found that decreasing the water mass flow rate improves the heating of the radiant floor. The percentage improvement in floor temperature due to heating over the reference room, reaches about 17% and 6% at mass flow rates of 0.04 and 0.08 kg/s, respectively. Engineering Equation Solver (EES) was used to solve the equations for the heat transfer process between the heating water and the floor. It was found that decreasing the mass flow rate increases the residence time of the heating water in the radiant floor, consequently, increases the heat energy transfer and the floor temperature. Increasing the heating fluid mass flow rate in green buildings could have a negative effect on the heat transfer, such that the appropriate heating fluid mass flow rate should be calculated based on the green building massive material as well as the operating conditions, for example, ambient temperature and wind speed.


  • Open Access

    Numerical investigation of the effect of dust shields on accumulation of dust over PV panels

    by Ramy Shenouda, Mohamed S. Abd-Elhady, Hamdy A. Kandil, Mahmoud M. Dagher

    Dust accumulation on photovoltaic panels represents a major challenge for the operation of solar panels especially in the regions known by their high rate of dust and low frequency of rain. The objective of this study is to minimize dust accumulation on PV panels operating street light posts using dust shields. A novel dust shield having the same width of the panel, and subtending an angle of 120° with the panel, is proposed for dust mitigation. Numerical simulations are carried out to evaluate the influence of the dust shield on dust accumulation over the panel’s surface. It is found that using a dust shield decreases the dust deposition rate by more than 44%. Moreover, extending the panel’s surface at the lower edge with an extension plate together with the dust shield decreases the dust deposition rate better than using a dust shield only. Also, the effect of adding an air gap between the shield and the added extension plate is investigated, and it is found that the air gap induces air drafts over the panel’s surface, which acts as an air barrier that obstructs the approach of dust particles to the panel’s surface. These drafts get stronger as the air gap thickness increases, accordingly, less particles deposit on the panel. Finally, it is found that using a dust shield with a length smaller than the panel’s length in addition to an extension plate together and increasing the thickness of the air gap is an effective and efficient solution for dust mitigation, such that the percentage decrease in the dust deposition rate that might be more than 88%.