Robin Girard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robin Girard has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Georges Kariniotakis
Center for Processes, Renewable Energies and Energy Systems (PERSEE), MINES ParisTech, PSL University, Sophia-Antipolis, France
26 shared publications - Andrea Michiorri
Centre for Processes, Renewable Energies and Energy Systems (PERSEE), MINES Paris - PSL University, Sophia Antipolis, France
5 shared publications - Quentin Raillard--Cazanove
Centre for Renewable Energy Systems Technology, Loughborough University, Loughborough LE11 3TU, UK
5 shared publications Arthur Bossavy
4 shared publications- Pedro Henrique Affonso Nóbrega
Mines Paris, PSL University
4 shared publications - Antoine Rogeau3 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Distributed small-reservoir pumped-storage hydropower in Europe: a GIS screening under drawdown and karst constraints
- 30 October 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Open AccessDistributed small-reservoir pumped-storage hydropower in Europe: a GIS screening under drawdown and karst constraints
- Open Access
- 4 September 2026
- Published by Elsevier in SSRN Electronic Journal
The visual footprint of wind power: a solid-angle metric for the visual impact of energy infrastructure
The land wind power takes can be counted two ways. By the direct footprint of masts and tracks, a wind farm occupies almost nothing; by total project area, it occupies a landscape that in fact remains farmed and inhabited. The dispute is about neither: it is about what turbines do to the view, and that has had no objective, computable measure, with practice relying on binary viewsheds, photomontages or camera-frame percentages. This paper proposes the missing measure, the solid angle that infrastructure subtends at each point of a territory: the share of the visual field it occupies, read here in full moons, computed exactly from turbine geometry with terrain, forest and building masking. Across the French onshore fleet the median machine subtends 68~full moons at 1~km (an upper bound that takes the swept rotor as opaque; a glance convention divides it by about 3, the blades-only silhouette by an order of magnitude) and stays above one full moon out to 8.3~km. Under masking, the average point of France receives 20~moons and the average resident 7.5, while the median resident receives essentially none: exposure is a tail phenomenon. Twenty national fleets on four continents, masked identically, order along a siting axis, from the United States, which dilutes turbines far from people, to China, which places them closer to residents than any European fleet; register coordinate quality bounds how precisely that gap can be measured. On ten million house sales in France and England & Wales, the dose discounts upper-segment prices by about 2% per log-moon, the one estimate that survives a family-wise correction over the widest family tested, nesting the literature's binary visible-versus-hidden discounts as points on one continuous physical axis.
- 4 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe visual footprint of wind power: a solid-angle metric for the visual impact of energy infrastructure
The land wind power takes can be counted two ways. By the direct footprint of masts and tracks, a wind farm occupies almost nothing; by total project area, it occupies a landscape that in fact remains farmed and inhabited. The dispute is about neither: it is about what turbines do to the view, and that has had no objective, computable measure, with practice relying on binary viewsheds, photomontages or camera-frame percentages. This paper proposes the missing measure, the solid angle that infrastructure subtends at each point of a territory: the share of the visual field it occupies, read here in full moons, computed exactly from turbine geometry with terrain, forest and building masking. Across the French onshore fleet the median machine subtends 68~full moons at 1~km (an upper bound that takes the swept rotor as opaque; a glance convention divides it by about 3, the blades-only silhouette by an order of magnitude) and stays above one full moon out to 8.3~km. Under masking, the average point of France receives 20~moons and the average resident 7.5, while the median resident receives essentially none: exposure is a tail phenomenon. Twenty national fleets on four continents, masked identically, order along a siting axis, from the United States, which dilutes turbines far from people, to China, which places them closer to residents than any European fleet; register coordinate quality bounds how precisely that gap can be measured. On ten million house sales in France and England & Wales, the dose discounts upper-segment prices by about 2% per log-moon, the one estimate that survives a family-wise correction over the widest family tested, nesting the literature's binary visible-versus-hidden discounts as points on one continuous physical axis.
- Open Access
- 22 August 2026
- Published by Elsevier in SSRN Electronic Journal
Mapping the cost-competitiveness of alternative industrial heat supply portfolios: A multi-scale perspective
Heat production accounts for a large share of industrial final energy consumption and remains largely based on natural gas. Despite the availability of mature power-to-heat technologies, their industrial uptake remains limited, highlighting the need to better understand their economic competitiveness across plausible future energy prices and industrial contexts. Accordingly, this study develops a multi-scale sensitivity framework to assess the levelized cost of heat (LCOH) of alternative technology portfolios across future energy-system conditions and industrial-site characteristics. A key novelty is the consistent representation of electricity and methane prices while retaining a detailed representation of the industrial heat-supply system. Results for a chemical facility in France show that hybrid gas–electric portfolios are economically preferred across the investigated parameter space. When the gas boiler is removed, on-site PV generation and thermal energy storage are jointly deployed across most scenarios, substantially improving the competitiveness of full electrification and reducing the LCOH range from 50–125 €/MWh for an electric boiler alone to 47–69 €/MWh. The multi-scale analysis further shows that LCOH remains primarily driven by energy-system conditions, although this dependence weakens as more integrated, capital-intensive portfolios are deployed. This underscores the need to represent methane and electricity prices consistently when assessing industrial electrification. Integrated portfolios, in turn, demonstrate their hedging potential across future energy prices. Finally, contrasting emissions obtained using average and marginal carbon accounting highlight the importance of considering industrial electrification within the broader evolution of the energy system when jointly assessing its economic and environmental implications.
- 22 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMapping the cost-competitiveness of alternative industrial heat supply portfolios: A multi-scale perspective
Heat production accounts for a large share of industrial final energy consumption and remains largely based on natural gas. Despite the availability of mature power-to-heat technologies, their industrial uptake remains limited, highlighting the need to better understand their economic competitiveness across plausible future energy prices and industrial contexts. Accordingly, this study develops a multi-scale sensitivity framework to assess the levelized cost of heat (LCOH) of alternative technology portfolios across future energy-system conditions and industrial-site characteristics. A key novelty is the consistent representation of electricity and methane prices while retaining a detailed representation of the industrial heat-supply system. Results for a chemical facility in France show that hybrid gas–electric portfolios are economically preferred across the investigated parameter space. When the gas boiler is removed, on-site PV generation and thermal energy storage are jointly deployed across most scenarios, substantially improving the competitiveness of full electrification and reducing the LCOH range from 50–125 €/MWh for an electric boiler alone to 47–69 €/MWh. The multi-scale analysis further shows that LCOH remains primarily driven by energy-system conditions, although this dependence weakens as more integrated, capital-intensive portfolios are deployed. This underscores the need to represent methane and electricity prices consistently when assessing industrial electrification. Integrated portfolios, in turn, demonstrate their hedging potential across future energy prices. Finally, contrasting emissions obtained using average and marginal carbon accounting highlight the importance of considering industrial electrification within the broader evolution of the energy system when jointly assessing its economic and environmental implications.
- Open Access
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Distributed small-reservoir pumped-storage hydropower in Europe: a GIS screening under drawdown and karst constraints
Continental pumped-storage hydropower (PSH) atlases omit schemes made of small reservoirs, although such sites could provide distributed flexibility. We screen this resource across 36 European countries by detecting closed depressions and water bodies, pairing upper and lower reservoirs under land-use, protection and grid-distance constraints. The reproducible workflow uses open pan-European datasets, is benchmarked against high-resolution French data, and---unlike estimates based on a fixed fraction of lake volume---constrains usable storage through explicit allowable water-level variations. At a 5-km grid distance and 1-m drawdown, a non-overlapping selection yields a screened upper bound of 3.21 TWh; excluding dry pairs whose midpoint intersects mapped karst, capping upper-reservoir elevation at 2500 m, and solving the selection exactly as a maximum-weight matchinggives 1.42\,TWh, of which a $\sim$29\,200-site reference portfolio capped at100\,MWh per site stores 0.75\,TWh (0.28\,TWh in the EU-27). Sensitivityanalysis makes the maximum inter-reservoir distance the dominant control(Sobol index $S_T=0.64$), ahead of the karst treatment and griddistance; the non-karst potential spans 0.75--1.31\,TWh (energy cap) and1.25--1.69\,TWh (drawdown 0.5--2\,m). Thisis a screened resource, not a deployable capacity---site-level feasibilityremains to be established---best used to prioritize national feasibilitystudies rather than guide investment.
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDistributed small-reservoir pumped-storage hydropower in Europe: a GIS screening under drawdown and karst constraints
Continental pumped-storage hydropower (PSH) atlases omit schemes made of small reservoirs, although such sites could provide distributed flexibility. We screen this resource across 36 European countries by detecting closed depressions and water bodies, pairing upper and lower reservoirs under land-use, protection and grid-distance constraints. The reproducible workflow uses open pan-European datasets, is benchmarked against high-resolution French data, and---unlike estimates based on a fixed fraction of lake volume---constrains usable storage through explicit allowable water-level variations. At a 5-km grid distance and 1-m drawdown, a non-overlapping selection yields a screened upper bound of 3.21 TWh; excluding dry pairs whose midpoint intersects mapped karst, capping upper-reservoir elevation at 2500 m, and solving the selection exactly as a maximum-weight matchinggives 1.42\,TWh, of which a $\sim$29\,200-site reference portfolio capped at100\,MWh per site stores 0.75\,TWh (0.28\,TWh in the EU-27). Sensitivityanalysis makes the maximum inter-reservoir distance the dominant control(Sobol index $S_T=0.64$), ahead of the karst treatment and griddistance; the non-karst potential spans 0.75--1.31\,TWh (energy cap) and1.25--1.69\,TWh (drawdown 0.5--2\,m). Thisis a screened resource, not a deployable capacity---site-level feasibilityremains to be established---best used to prioritize national feasibilitystudies rather than guide investment.
- Open Access
- 21 July 2026
- Published by Elsevier in SSRN Electronic Journal
The visual footprint of wind power: a solid-angle metric for the visual impact of energy infrastructure
The land taken by energy infrastructure is routinely quantified; its most contested externality — visual intrusion — is still assessed through binary viewsheds, photomontages or camera-frame percentages, never through a physical exposure metric. We propose the solid angle (steradians) that infrastructure subtends at each point of a territory — the quantity behind glare and sky-view metrics — and an exact, open-source, ray-casting-validated method for wind turbines with terrain masking. Across France's 1,845 operating onshore wind farms the median machine subtends 68 full moons at 1 km (swept-rotor upper bound; glance or blades-only conventions divide this by ~3–10) and stays above one full moon out to 8.3 km. With relief and forest masking the average point of France receives 20 moons, the average resident 7.5 — half the unmasked values — and the median resident essentially none: exposure is a tail phenomenon. Under identical masking, twenty national fleets on four continents reveal a siting axis the European view hides: the United States dilutes turbines far from people, whereas China, India and Brazil place them amid dense population, so residents see four-to-five times the territorial average (China above every European fleet). On geolocated house sales in France and England & Wales, the dose discounts upper-segment prices by about 2% per log-moon — persisting between equally distant homes and appearing with the machines, not the permits — nesting the literature's binary visible-versus-hidden discounts as endpoints of one continuous physical axis.
- 21 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe visual footprint of wind power: a solid-angle metric for the visual impact of energy infrastructure
The land taken by energy infrastructure is routinely quantified; its most contested externality — visual intrusion — is still assessed through binary viewsheds, photomontages or camera-frame percentages, never through a physical exposure metric. We propose the solid angle (steradians) that infrastructure subtends at each point of a territory — the quantity behind glare and sky-view metrics — and an exact, open-source, ray-casting-validated method for wind turbines with terrain masking. Across France's 1,845 operating onshore wind farms the median machine subtends 68 full moons at 1 km (swept-rotor upper bound; glance or blades-only conventions divide this by ~3–10) and stays above one full moon out to 8.3 km. With relief and forest masking the average point of France receives 20 moons, the average resident 7.5 — half the unmasked values — and the median resident essentially none: exposure is a tail phenomenon. Under identical masking, twenty national fleets on four continents reveal a siting axis the European view hides: the United States dilutes turbines far from people, whereas China, India and Brazil place them amid dense population, so residents see four-to-five times the territorial average (China above every European fleet). On geolocated house sales in France and England & Wales, the dose discounts upper-segment prices by about 2% per log-moon — persisting between equally distant homes and appearing with the machines, not the permits — nesting the literature's binary visible-versus-hidden discounts as endpoints of one continuous physical axis.
- Open Access
- 3 April 2026
- Published by Elsevier in Energy and Buildings
- Vol. 361
A scalable activity-based and physics-informed bottom-up model for residential electricity demand using open data
- 3 April 2026
- Published by Elsevier in Energy and Buildings
- Vol. 361
Open AccessA scalable activity-based and physics-informed bottom-up model for residential electricity demand using open data
- Open Access
- 23 March 2026
- Published by Elsevier in Energy Policy
- Vol. 214
Resilience analysis for energy foresight scenarios: addressing the deep uncertainties of hydrogen deployment in industrial hubs
- 23 March 2026
- Published by Elsevier in Energy Policy
- Vol. 214
Open AccessResilience analysis for energy foresight scenarios: addressing the deep uncertainties of hydrogen deployment in industrial hubs
- Open Access
- 27 January 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 175
Optimal operational planning of hybrid power plants in railway MVDC networks and comparison with standard AC connections
- 27 January 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 175
Open AccessOptimal operational planning of hybrid power plants in railway MVDC networks and comparison with standard AC connections
- 24 October 2025
- Published by Elsevier in Energy Economics
- Vol. 152
Hedging hydrogen: Planning and contracting under uncertainty for a green hydrogen producer
- 24 October 2025
- Published by Elsevier in Energy Economics
- Vol. 152
Hedging hydrogen: Planning and contracting under uncertainty for a green hydrogen producer
- Open Access
An aggregation method to model district heating networks in large-scale multi-energy simulations