Daisuke Koyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daisuke Koyama has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Mami Matsukawa
Faculty of Science and Engineering, Doshisha University, Japan
24 shared publications Mami Matsukawa
17 shared publicationsAkira Emoto
Doshisha University 1-3 Tataramiyakodani 610-0321 Kyotanabe Kyoto Japan
12 shared publications- Yuma Kuroda
Faculty of Science and Engineering, Doshisha University 1 , 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321, Japan
8 shared publications - Jessica Onaka
Faculty of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
7 shared publications - Kentaro Nakamura
Institute of Integrated Research, Institute of Sciences Tokyo, Yokohama, Japan
7 shared publications
Latest Publications
- 8 July 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65  (13) , 138002
Ultrasound hemispherical variable-focus lenses for lensed fibers
In optical communications, where efficient coupling of laser diodes with optical fibers is paramount, lensed fibers with lens-like functionality have been developed. However, adjustments may require precise mechanical components. Here, we proposed a tunable hemispherical lens that combined a transparent viscoelastic gel and ultrasound generated by a piezoelectric transducer. The acoustic radiation forces deformed the gel surface, which decreased the focal length as the input voltage increased. Its optical properties were investigated for potential applications to lensed fibers. The hemispherical gel lens could function as a tunable convex lens for tunable lensed fibers.
- 8 July 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65  (13) , 138002
Ultrasound hemispherical variable-focus lenses for lensed fibers
In optical communications, where efficient coupling of laser diodes with optical fibers is paramount, lensed fibers with lens-like functionality have been developed. However, adjustments may require precise mechanical components. Here, we proposed a tunable hemispherical lens that combined a transparent viscoelastic gel and ultrasound generated by a piezoelectric transducer. The acoustic radiation forces deformed the gel surface, which decreased the focal length as the input voltage increased. Its optical properties were investigated for potential applications to lensed fibers. The hemispherical gel lens could function as a tunable convex lens for tunable lensed fibers.
- 26 May 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65  (16) , 5397-5404
Liquid-crystal neutral density filter that can be tuned using ultrasound
Conventional fixed neutral density (ND) filters are designed with a specific, predetermined attenuation level. Thus, users need to manually swap filters depending on the environment or application. Existing variable ND filters often require complex fabrication processes and control mechanisms. In this study, we proposed a variable ND filter with no mechanical moving parts in which the light exposure can be adjusted by using ultrasonic vibration to control the twisted-nematic (TN) liquid-crystal (LC) molecular orientation. This ultrasonic variable ND filter consists of glass discs, a TN LC layer, and an ultrasonic transducer. The application of an electrical signal induced a resonant flexural vibration mode, generating an acoustic radiation force. This force effectively disrupted the twisted orientation of the LC layer, enabling the transmitted light intensity to be controlled by the input voltage. This filter, with a thin and simple structure, could facilitate the development of thinner and lower-cost optical devices.
- 26 May 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65  (16) , 5397-5404
Liquid-crystal neutral density filter that can be tuned using ultrasound
Conventional fixed neutral density (ND) filters are designed with a specific, predetermined attenuation level. Thus, users need to manually swap filters depending on the environment or application. Existing variable ND filters often require complex fabrication processes and control mechanisms. In this study, we proposed a variable ND filter with no mechanical moving parts in which the light exposure can be adjusted by using ultrasonic vibration to control the twisted-nematic (TN) liquid-crystal (LC) molecular orientation. This ultrasonic variable ND filter consists of glass discs, a TN LC layer, and an ultrasonic transducer. The application of an electrical signal induced a resonant flexural vibration mode, generating an acoustic radiation force. This force effectively disrupted the twisted orientation of the LC layer, enabling the transmitted light intensity to be controlled by the input voltage. This filter, with a thin and simple structure, could facilitate the development of thinner and lower-cost optical devices.
- Open Access
- 1 March 2026
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 47  (2) , 202-205
Effect of the thickness of the glass substrate on an ultrasonic liquid crystal lens
Liquid crystal (LC) varifocal lenses are characterized by their need for compactness and high-speed response, rendering them well-suited for next-generation optical devices. The focal length can be modulated by reorienting LC molecules through acoustic radiation force. In this study, the influence of the geometrical structure of ultrasonic LC lenses on the optical performance was examined. Two LC lenses with distinct glass substrate thicknesses were fabricated, and their optical characteristics were evaluated. The electro-mechanical parameters were found to be altered by the thickness of the glass substrate, which consequently led to an improvement in the power consumption in focus tunability.
- 1 March 2026
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 47  (2) , 202-205
Open AccessEffect of the thickness of the glass substrate on an ultrasonic liquid crystal lens
Liquid crystal (LC) varifocal lenses are characterized by their need for compactness and high-speed response, rendering them well-suited for next-generation optical devices. The focal length can be modulated by reorienting LC molecules through acoustic radiation force. In this study, the influence of the geometrical structure of ultrasonic LC lenses on the optical performance was examined. Two LC lenses with distinct glass substrate thicknesses were fabricated, and their optical characteristics were evaluated. The electro-mechanical parameters were found to be altered by the thickness of the glass substrate, which consequently led to an improvement in the power consumption in focus tunability.
- Open Access
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 53-57
Square-Wave Driven Ultrasonic Liquid Crystal Optical Lenses
Conventional optical lenses only have one focal point. Whereas compound lens systems with multiple lenses and mechanical actuators are used in modules to focus on near and far objects. Camera modules with these systems tend to be bulky and have a slow time response. Electrically-controllable varifocal lenses will accelerate the development of compact photographic devices with high-speed responses. Here, we discuss an ultrasound varifocal liquid crystal (LC) lens that consists of an LC layer between two glass discs and an ultrasound transducer. The orientation of nematic LC molecules could be controlled by acoustic radiation forces, and the lens could change the refractive index distribution and its focal length by ultrasound vibration by utilizing the high LC liquidity and optical anisotropy. The effects of input waveforms on the optical characteristics of the ultrasonic LC lens were investigated in an industrial setting. We applied sinusoidal and square waves at the resonant frequency of the lenses to assess the impact on the optical characteristics. Those characteristics were largely similar. However, slight differences were observed in the vibrational distributions on the lens substrate, indicating that the lens could be controlled by a square-wave drive.
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 53-57
Open AccessSquare-Wave Driven Ultrasonic Liquid Crystal Optical Lenses
Conventional optical lenses only have one focal point. Whereas compound lens systems with multiple lenses and mechanical actuators are used in modules to focus on near and far objects. Camera modules with these systems tend to be bulky and have a slow time response. Electrically-controllable varifocal lenses will accelerate the development of compact photographic devices with high-speed responses. Here, we discuss an ultrasound varifocal liquid crystal (LC) lens that consists of an LC layer between two glass discs and an ultrasound transducer. The orientation of nematic LC molecules could be controlled by acoustic radiation forces, and the lens could change the refractive index distribution and its focal length by ultrasound vibration by utilizing the high LC liquidity and optical anisotropy. The effects of input waveforms on the optical characteristics of the ultrasonic LC lens were investigated in an industrial setting. We applied sinusoidal and square waves at the resonant frequency of the lenses to assess the impact on the optical characteristics. Those characteristics were largely similar. However, slight differences were observed in the vibrational distributions on the lens substrate, indicating that the lens could be controlled by a square-wave drive.
- 28 April 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50  (9) , 2978-2981
Ultrasound cholesteric liquid crystal color filter
We present an ultrasonically tunable color filter based on cholesteric liquid crystals (CLCs), where ultrasound excitation dynamically modulates the helical pitch. Three CLC cells with different chiral dopant concentrations (4 wt%, 7 wt%, and 12 wt%) were investigated. The 12 wt% dopant cell exhibited the most significant spectral shift, with the transmission peak shifting from 511 nm to 451 nm, under ultrasound actuation, achieving a 60-nm tunable range. Chromaticity analysis confirms a reversible color transition, demonstrating the effectiveness of ultrasound in dynamically tuning optical properties.
- 28 April 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50  (9) , 2978-2981
Ultrasound cholesteric liquid crystal color filter
We present an ultrasonically tunable color filter based on cholesteric liquid crystals (CLCs), where ultrasound excitation dynamically modulates the helical pitch. Three CLC cells with different chiral dopant concentrations (4 wt%, 7 wt%, and 12 wt%) were investigated. The 12 wt% dopant cell exhibited the most significant spectral shift, with the transmission peak shifting from 511 nm to 451 nm, under ultrasound actuation, achieving a 60-nm tunable range. Chromaticity analysis confirms a reversible color transition, demonstrating the effectiveness of ultrasound in dynamically tuning optical properties.
- Open Access
- 17 March 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137  (11)
Ultrasonically induced microscopic refractive index gradient and the relationship with high-frequency ultrasonic cavitation
The refractive index of a medium can be modulated by external stimuli such as pressure, temperature, or electromagnetic forces. This principle enables fast, precise, and reversible optical control and has catalyzed the development of optical devices and optical measurement technology. Here, we report the relationship between the refractive index change induced by high-frequency ultrasonic irradiation and ultrasonic cavitation. The cavitation nanobubbles generated by ultrasonic irradiation were measured using dynamic light scattering to be approximately 100 nm in diameter. The apparent volume fraction of the nanobubbles induced near the surface of the ultrasonic transducer was calculated using an effective medium approximation. The apparent volume fraction was 0.12 at the position where the refractive index change was maximal (Δn = 0.04: value from the fitting function). The technique to control light propagation in a local (microscale) region with ultrasonic irradiation has a wide range of applications from optofluidic devices for lab-on-chip devices to variable-focus lenses for industrial metrology.
- 17 March 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137  (11)
Open AccessUltrasonically induced microscopic refractive index gradient and the relationship with high-frequency ultrasonic cavitation
The refractive index of a medium can be modulated by external stimuli such as pressure, temperature, or electromagnetic forces. This principle enables fast, precise, and reversible optical control and has catalyzed the development of optical devices and optical measurement technology. Here, we report the relationship between the refractive index change induced by high-frequency ultrasonic irradiation and ultrasonic cavitation. The cavitation nanobubbles generated by ultrasonic irradiation were measured using dynamic light scattering to be approximately 100 nm in diameter. The apparent volume fraction of the nanobubbles induced near the surface of the ultrasonic transducer was calculated using an effective medium approximation. The apparent volume fraction was 0.12 at the position where the refractive index change was maximal (Δn = 0.04: value from the fitting function). The technique to control light propagation in a local (microscale) region with ultrasonic irradiation has a wide range of applications from optofluidic devices for lab-on-chip devices to variable-focus lenses for industrial metrology.
- Open Access
- 1 March 2025
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5  (3)
Bone mineral density and hydroxyapatite alignment in leg cortical bone influence on ultrasound velocity
Bone diagnosis using x-ray techniques, such as computed tomography and dual-energy x-ray absorptiometry, can evaluate bone mineral density (BMD) and microstructure but does not provide elastic properties. This study investigated the ultrasonic properties of racehorse leg cortical bone, focusing on the relationship between wave velocity, BMD, and hydroxyapatite (HAp) crystallite alignment. The results showed a strong correlation between wave velocity and BMD, suggesting that quantitative ultrasound-obtained wave velocity is primarily influenced by BMD, followed by the HAp alignment direction.
- 1 March 2025
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5  (3)
Open AccessBone mineral density and hydroxyapatite alignment in leg cortical bone influence on ultrasound velocity
Bone diagnosis using x-ray techniques, such as computed tomography and dual-energy x-ray absorptiometry, can evaluate bone mineral density (BMD) and microstructure but does not provide elastic properties. This study investigated the ultrasonic properties of racehorse leg cortical bone, focusing on the relationship between wave velocity, BMD, and hydroxyapatite (HAp) crystallite alignment. The results showed a strong correlation between wave velocity and BMD, suggesting that quantitative ultrasound-obtained wave velocity is primarily influenced by BMD, followed by the HAp alignment direction.
- 22 January 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64  (4) , 821-827
Ultrasound liquid–gel hybrid lens using acoustic radiation forces
Conventional camera modules use a mechanical system comprising moving parts to change the focal length of the lens by moving it along the optical axis, increasing the volume of the camera. Here, the potential of compact variable-focus lenses was examined to enhance response speed and robustness via a combination of viscoelastic gel films, liquids, and acoustic radiation forces. The optical properties of the lenses were evaluated using a wavefront sensor. Focal lengths could be controlled by changing the lens shape via acoustic radiation forces generated by ultrasound vibrations. The response time of the lens was dependent on the thickness of the gel film on the lens surface; a thinner film thickness resulted in a shorter response time. The response times for hybrid lenses with gel film thickness of , 0.8 mm, 1 mm, and 2 mm were 58 ms, 68 ms, 82 ms, and 172 ms, respectively.
- 22 January 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64  (4) , 821-827
Ultrasound liquid–gel hybrid lens using acoustic radiation forces
Conventional camera modules use a mechanical system comprising moving parts to change the focal length of the lens by moving it along the optical axis, increasing the volume of the camera. Here, the potential of compact variable-focus lenses was examined to enhance response speed and robustness via a combination of viscoelastic gel films, liquids, and acoustic radiation forces. The optical properties of the lenses were evaluated using a wavefront sensor. Focal lengths could be controlled by changing the lens shape via acoustic radiation forces generated by ultrasound vibrations. The response time of the lens was dependent on the thickness of the gel film on the lens surface; a thinner film thickness resulted in a shorter response time. The response times for hybrid lenses with gel film thickness of , 0.8 mm, 1 mm, and 2 mm were 58 ms, 68 ms, 82 ms, and 172 ms, respectively.
- Open Access
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- p. 1
Optical Characteristics of an Ultrasound Gel Lens
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- p. 1
Open AccessOptical Characteristics of an Ultrasound Gel Lens
- Open Access
- 28 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14  (1) , 1-9
Control of myotube orientation using ultrasonication
This study investigated a technique for controlling the orientation of C2C12-derived myotube cells using ultrasonication for future clinical applications of cultured skeletal muscle tissues. An ultrasonicating cell culture dish, comprising a plastic-bottomed culture dish and a circular glass plate (diameter, 35 mm; thickness, 1.1 mm) attached to an annular piezoelectric ultrasonic transducer (inner diameter, 10 mm; outer diameter, 20 mm; thickness, 1 mm), was constructed. A concentric resonant vibrational mode at 89 kHz was generated on the bottom of the dish, and the orientations of myotube cells were quantitatively evaluated using two-dimensional Fourier transform analysis of phase contrast microscopy images captured over a 14 × 10 mm2 area at the center of the dish. Unsonicated myotube cells grew in random directions, but ultrasonication aligned them circumferentially in the culture dish. The timing of treatment was important, with ultrasonication for 48 h before differentiation having a greater impact on myotube orientation than ultrasonication after differentiation. A larger ultrasonic vibration, with an amplitude of over 20 Vpp, resulted in significantly smaller angles of deviation in the circumferential direction than the control. Ultrasonication enhanced the expression of differentiation-related genes and the formation of aligned myotubes, suggesting that it promotes differentiation of C2C12 cells into myotubes.
- 28 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14  (1) , 1-9
Open AccessControl of myotube orientation using ultrasonication
This study investigated a technique for controlling the orientation of C2C12-derived myotube cells using ultrasonication for future clinical applications of cultured skeletal muscle tissues. An ultrasonicating cell culture dish, comprising a plastic-bottomed culture dish and a circular glass plate (diameter, 35 mm; thickness, 1.1 mm) attached to an annular piezoelectric ultrasonic transducer (inner diameter, 10 mm; outer diameter, 20 mm; thickness, 1 mm), was constructed. A concentric resonant vibrational mode at 89 kHz was generated on the bottom of the dish, and the orientations of myotube cells were quantitatively evaluated using two-dimensional Fourier transform analysis of phase contrast microscopy images captured over a 14 × 10 mm2 area at the center of the dish. Unsonicated myotube cells grew in random directions, but ultrasonication aligned them circumferentially in the culture dish. The timing of treatment was important, with ultrasonication for 48 h before differentiation having a greater impact on myotube orientation than ultrasonication after differentiation. A larger ultrasonic vibration, with an amplitude of over 20 Vpp, resulted in significantly smaller angles of deviation in the circumferential direction than the control. Ultrasonication enhanced the expression of differentiation-related genes and the formation of aligned myotubes, suggesting that it promotes differentiation of C2C12 cells into myotubes.