JOJessica Onaka

Jessica Onaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jessica Onaka has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative polarimetric characterization of micron-scale scratches on transparent surfaces using Scheimpflug dark-field imaging

    by Manning Sun, Nathan Hagen, Jessica Onaka, Yukitoshi Otani

    We propose a quantitative polarimetric imaging method for the characterization of micron-scale scratches on transparent surfaces using dark-field illumination. By combining oblique dark-field illumination, Scheimpflug imaging, and polarization-resolved detection, the proposed approach enhances the visibility of weak surface scratches while maintaining a consistent focus on a tilted observation region. Scratch widths are quantitatively extracted from polarization-derived parameter maps and compared with reference measurements obtained by commercial white-light interferometry and laser scanning microscopy. Experiments on scratches with nominal widths of 1, 5, 10, and 20 µm show close agreement among the three measurement approaches, demonstrating quantitative consistency over the evaluated micron-scale range.

  • Compact optical evaluation system for AR-HUDs: a flexible bench enabling cross-windshield imaging assessment

    by Manning Sun, Nathan Hagen, Jessica Onaka, Ryoichi Kuwano, Toshihiko Koga, Yukitoshi Otani

    The imaging performance of augmented reality head-up displays (AR-HUDs) is strongly affected by windshield-dependent optical characteristics, making quantitative comparison across different windshield designs challenging in conventional laboratory setups. We present a compact optical evaluation system that reproduces the projection geometry of a conventional long-path AR-HUD test bench using a folded optical layout with a metal substrate concave mirror and a planar surrogate glass. The proposed system is validated through Zemax simulations and knife-edge-based modulation transfer function (MTF) measurements for two automotive windshields from different manufacturers. The results show that the compact configuration preserves the frequency-dependent MTF behavior and relative performance ranking observed in the conventional system. The MTF50 values obtained from the two systems differ by <0.3 lp/mm, and the overall MTF deviation remains within ±0.03 across the measured spatial frequency range. These results demonstrate that the proposed compact system provides a reliable and efficient platform for quantitative AR-HUD performance evaluation and cross-windshield comparison within a reduced-scale experimental framework.

  • Ultrasound cholesteric liquid crystal color filter

    by Jessica Onaka, Yuna Kim, Daisuke Koyama, Nathan Hagen, Yukitoshi Otani

    We present an ultrasonically tunable color filter based on cholesteric liquid crystals (CLCs), where ultrasound excitation dynamically modulates the helical pitch. Three CLC cells with different chiral dopant concentrations (4 wt%, 7 wt%, and 12 wt%) were investigated. The 12 wt% dopant cell exhibited the most significant spectral shift, with the transmission peak shifting from 511 nm to 451 nm, under ultrasound actuation, achieving a 60-nm tunable range. Chromaticity analysis confirms a reversible color transition, demonstrating the effectiveness of ultrasound in dynamically tuning optical properties.


  • Open Access

    Front Cover

    by Shunsuke Hashimoto, Yuki Harada, Kôsuke Nakamura, Takahiro Iwase, Jessica Onaka, Mami Matsukawa, Daisuke Koyama

    Presents the front cover for this issue of the publication.

  • Varifocal Concave–Convex Lens Using Viscoelastic Gel and Ultrasound Vibration

    by Shunsuke Hashimoto, Yuki Harada, Kosuke Nakamura, Takahiro Iwase, Jessica Onaka, Mami Matsukawa, Daisuke Koyama

    A varifocal concave–convex lens using ultrasound and transparent viscoelastic gel is reported. The configuration of the lens is simple and thin, consisting of four pieces of a piezoelectric ultrasound transducer, a glass disk, and a transparent silicone gel film. It uses a combination of the ultrasound resonant flexural standing- and traveling-wave modes excited by in-phase and four-phase drives so that the lens can change its shape to both concave and convex by switching the resonance mode with the same structure. The acoustic radiation force (ARF) originated from the resonant flexural vibration modes changed the surface profile of the gel. Convex and concave deformation were generated at the center of the lens at the resonance frequencies of 38 and 60 kHz, respectively, indicating that a varifocal concave–convex lens could be fabricated by controlling the driving frequency, voltage amplitude, and phase differences among the ultrasound transducers. The deformational displacement on the lens surface and the change in the focal length increased with the input voltage amplitude. The optical microscopic images observed through the lens were enlarged $1.28\times $ (reduced $0.92\times $ ) in the convex (concave) mode with 20 ${V}_{\text {pp}}$ . The response time for focusing and the temperature stability under operation were evaluated. By switching the resonance vibration modes of the lens through the input signals to multiple ultrasound transducers, the variable-focus function with both concave and convex lenses was achieved in the same configuration.


  • Orientation angles of liquid crystals via ultrasound vibrations

    by Takahiro Iwase, Yuma Kuroda, Jessica Onaka, Akira Emoto, Mami Matsukawa, Daisuke Koyama

    The orientation angles of liquid crystal (LC) molecules were measured during ultrasound vibrations. Light transmitted through a fabricated LC lens was analyzed via the crossed Nicol condition and a crystal rotation method. The LC orientation angle was estimated with a theoretical model, and its distribution in the lens was determined. There was a strong correlation between the molecular angles and ultrasonic vibrational distributions, indicating that the angle was changed by the acoustic radiation force. The maximum tilt angle was 12° for a 50 V peak-to-peak input.


  • Optical evaluation of a double-layered ultrasound liquid crystal lens

    by Jessica Onaka, Daisuke Koyama, Yuma Kuroda, Akira Emoto, Mami Matsukawa

    A method to improve the performance of an ultrasound liquid crystal lens is proposed. A double-layer-based lens model tailored based on the liquid crystal’s physical properties, e.g., its dielectric anisotropy and elastic constants, is presented as an alternative method to improve the lens’s optical performance while forming weak anchoring surfaces for nematic liquid crystals, thus promoting easier reorientation of the liquid crystal molecules. The lens configuration was simulated by finite-element analysis using Ansys software. The lens’s physical and optical characteristics were evaluated via comparison using two different liquid crystal materials: 5CB and RDP-85475. The birefringence distribution within the liquid crystal layer was investigated under ultrasound excitation, and the molecular angles of inclination were estimated. A higher birefringence distribution, greater molecular inclination, and a longer focal length were obtained for the double-layered liquid crystal lens using the 5CB material.


  • Relationship between liquid crystal layer thickness and variable-focusing characteristics of an ultrasound liquid crystal lens

    by Takahiro Iwase, Jessica Onaka, Akira Emoto, Daisuke Koyama, Mami Matsukawa

    The effect of the liquid crystal (LC) layer thickness on the optical characteristics of an ultrasound LC lens was explored. Three LC lenses with differing LC layer thicknesses (100, 200, and 300 μ m) were fabricated, and the optical focal lengths were measured by an optical microscope with a varying driving voltage. For the lens with a 200 μ m thick LC layer, a larger change in the focal length was observed for a smaller driving voltage compared with that of the other two lenses, indicating that the LC layer thickness is appropriate for a variable-focus lens.


  • Ultrasound liquid crystal lens with a variable focus in the radial direction for image stabilization

    by Jessica Onaka, Takahiro Iwase, Akira Emoto, Daisuke Koyama, Mami Matsukawa

    New technologies for adaptive optics are becoming increasingly important for miniature devices such as cell-phone cameras. In particular, motion-free autofocusing and optical image stabilization require sophisticated approaches for alternative lens architectures, materials, and processing to replace multiple solid elements. We discuss a new method, to the best of our knowledge, that provides image stabilization via an annular piezoelectric ceramic that uses ultrasound to drive a liquid crystal layer sandwiched between two circular glass substrates. The piezoelectric ceramic is divided into four quadrants that are independently driven with sinusoidal voltages at the resonant frequency of the lens. The technique is based on ultrasound vibrations with a suitable driving scheme. The lens configuration was modeled via finite-element analysis. Various combinations of the four-channel ultrasound transducer can be used to define the focal point of the liquid crystal lens. Clear optical images could be obtained with the lens. By using two-dimensional fast Fourier transforms, the focal point position was defined and shifted in the radial direction.