Dominik Kirpal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dominik Kirpal has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Franz Joseph Giessibl
University of Regensburg
4 shared publications - Alfred John Weymouth
University of Regensburg
3 shared publications - Korbinian Pürckhauer
Univ Regensburg, Dept Phys, Inst Expt & Appl Phys, D-93053 Regensburg, Germany
3 shared publications Anja Merkel
Institute of Experimental and Applied Physics, University of Regensburg , D-93053 Regensburg, Germany
1 shared publication- Daniel S. Wastl
Institute of Experimental and Applied Physics, University of Regensburg, Universitätsstraße 31, 93053 Regensburg, Germany
1 shared publication - Hiroaki Ooe
Faculty of Science, Yokohama City University, 22-2 Seto, Kanazawa-ku, Yokohama 236-0027, Japan
1 shared publication
Latest Publications
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043703
Biaxial atomically resolved force microscopy based on a qPlus sensor operated simultaneously in the first flexural and length extensional modes
Frequency-modulation atomic force microscopy (AFM) with a qPlus sensor allows one to atomically resolve surfaces in a variety of environments ranging from low-temperature in ultra-high vacuum to ambient and liquid conditions. Typically, the tip is driven to oscillate vertically, giving a measure of the vertical force component. However, for many systems, the lateral force component provides valuable information about the sample. Measuring lateral and vertical force components simultaneously by oscillating vertically and laterally has so far only been demonstrated with relatively soft silicon cantilevers and optical detection. Here, we show that the qPlus sensor can be used in a biaxial mode with electrical detection by making use of the first flexural mode and the length extensional mode. We describe the necessary electrode configuration as well as the electrical detection circuit and compare the length extensional mode to the needle sensor. Finally, we show atomic resolution in ambient conditions of a mica surface and in ultra-high vacuum of a silicon surface. In addition to this, we show how any qPlus AFM setup can be modified to work as a biaxial sensor, allowing two independent force components to be recorded.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043703
Biaxial atomically resolved force microscopy based on a qPlus sensor operated simultaneously in the first flexural and length extensional modes
Frequency-modulation atomic force microscopy (AFM) with a qPlus sensor allows one to atomically resolve surfaces in a variety of environments ranging from low-temperature in ultra-high vacuum to ambient and liquid conditions. Typically, the tip is driven to oscillate vertically, giving a measure of the vertical force component. However, for many systems, the lateral force component provides valuable information about the sample. Measuring lateral and vertical force components simultaneously by oscillating vertically and laterally has so far only been demonstrated with relatively soft silicon cantilevers and optical detection. Here, we show that the qPlus sensor can be used in a biaxial mode with electrical detection by making use of the first flexural mode and the length extensional mode. We describe the necessary electrode configuration as well as the electrical detection circuit and compare the length extensional mode to the needle sensor. Finally, we show atomic resolution in ambient conditions of a mica surface and in ultra-high vacuum of a silicon surface. In addition to this, we show how any qPlus AFM setup can be modified to work as a biaxial sensor, allowing two independent force components to be recorded.
- 1 August 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (8) , 083701
Combined atomic force microscope and scanning tunneling microscope with high optical access achieving atomic resolution in ambient conditions
Performing atomic force microscopy (AFM) and scanning tunneling microscopy (STM) with atomic resolution under ambient conditions is challenging due to enhanced noise and thermal drift. We show the design of a compact combined atomic force and scanning tunneling microscope that uses qPlus sensors and discuss the stability and thermal drift. By using a material with a low thermal expansion coefficient, we can perform constant height measurements and achieve atomic resolution in both AFM and STM on various samples. Moreover, the design allows a wide angle optical access to the sensor and the sample that is of interest for combining with optical microscopes or focusing optics with a high numerical aperture.
- 1 August 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (8) , 083701
Combined atomic force microscope and scanning tunneling microscope with high optical access achieving atomic resolution in ambient conditions
Performing atomic force microscopy (AFM) and scanning tunneling microscopy (STM) with atomic resolution under ambient conditions is challenging due to enhanced noise and thermal drift. We show the design of a compact combined atomic force and scanning tunneling microscope that uses qPlus sensors and discuss the stability and thermal drift. By using a material with a low thermal expansion coefficient, we can perform constant height measurements and achieve atomic resolution in both AFM and STM on various samples. Moreover, the design allows a wide angle optical access to the sensor and the sample that is of interest for combining with optical microscopes or focusing optics with a high numerical aperture.
- Open Access
- 30 October 2019
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 10 (1) , 2084-2093
Ion mobility and material transport on KBr in air as a function of the relative humidity
Ion mobility and material transport on KBr in air as a function of the relative humidity
- 30 October 2019
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 10 (1) , 2084-2093
Open AccessIon mobility and material transport on KBr in air as a function of the relative humidity
Ion mobility and material transport on KBr in air as a function of the relative humidity
- 3 October 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 109 (14) , 141603
Amplitude dependence of image quality in atomically-resolved bimodal atomic force microscopy
In bimodal frequency modulation atomic force microscopy (FM-AFM), two flexural modes are excited simultaneously. We show atomically resolved images of KBr(100) in ambient conditions in both modes that display a strong correlation between the image quality and amplitude. We define the sum amplitude as the sum of the amplitudes of both modes. When the sum amplitude becomes larger than about 100 pm, the signal-to-noise ratio (SNR) drastically decreases. We propose that this is caused by the temporary presence of one or more water layers in the tip-sample gap. These water layers screen the short range interaction and must be displaced with each oscillation cycle. Decreasing the amplitude of either mode, however, increases the noise. Therefore, the highest SNR in ambient conditions is achieved when twice the sum amplitude is slightly less than the thickness of the primary hydration layer.
- 3 October 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 109 (14) , 141603
Amplitude dependence of image quality in atomically-resolved bimodal atomic force microscopy
In bimodal frequency modulation atomic force microscopy (FM-AFM), two flexural modes are excited simultaneously. We show atomically resolved images of KBr(100) in ambient conditions in both modes that display a strong correlation between the image quality and amplitude. We define the sum amplitude as the sum of the amplitudes of both modes. When the sum amplitude becomes larger than about 100 pm, the signal-to-noise ratio (SNR) drastically decreases. We propose that this is caused by the temporary presence of one or more water layers in the tip-sample gap. These water layers screen the short range interaction and must be displaced with each oscillation cycle. Decreasing the amplitude of either mode, however, increases the noise. Therefore, the highest SNR in ambient conditions is achieved when twice the sum amplitude is slightly less than the thickness of the primary hydration layer.