Jakob. C. Larsson
Research Subjects
Jakob. C. Larsson has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Hans M. Hertz
Department of Applied Physics, Biomedical and X-ray Physics, KTH Royal Institute of Technology/Albanova, SE 106 91 Stockholm, Sweden
6 shared publicationsCarmen Vogt
Department of Applied Physics, Biomedical and X-ray Physics, KTH Royal Institute of Technology/Albanova, SE 106 91 Stockholm, Sweden
5 shared publications- Hans Martin Hertz
Department of Applied Physics, KTH Royal Institute of Technology/AlbaNova, 106 91 Stockholm, Sweden
5 shared publications - Muhammet Sadaka Toprak
KTH Royal Institute of Technology
3 shared publications Ulf Lundström
Biomedical and X-Ray Physics, Department of Applied Physics, KTH Royal Institute of Technology/Albanova, Stockholm 10691, Sweden
3 shared publicationsDaniel H. Larsson
KTH Royal Institute of Technology (Sweden)
2 shared publications
Latest Publications
- Open Access
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 78304-78316
A Comprehensive Study of Laboratory-Based Micro-CT for 3D Virtual Histology of Human FFPE Tissue Blocks
Advances in laboratory-based X-ray computed tomography (CT) have enabled X-ray 3D virtual histology. This method shows a great potential as a complementary technique to conventional 2D histology where extensive volumetric sampling is necessary. While formalin-fixed paraffin-embedded (FFPE) tissue blocks are the backbone of clinical histology, there exists no generic optimization, and technical study of the X-ray 3D virtual histology of FFPE blocks. X-ray micro-CT of FFPE blocks is studied and optimized in their native state within the cassette to minimize the interference of X-ray 3D virtual histology with clinical workflows and standards, hence facilitating the technology transfer to the clinics. The optimization is carried on the sample positioning, tungsten tubes acceleration voltage, and artifact reduction. Then propagation-based imaging of FFPE blocks is extensively discussed. Hierarchical (local) tomography and laminography are presented as viable approaches for achieving higher spatial resolutions. In the end, future perspectives are given by considering state-of-the-art micro-CT scanners using liquid-metal-jet sources, large-area detectors, and photon counting detectors. The results achieved here are generic and can be applicable to any laboratory-based scanner with a tungsten target source and cone-beam geometry. This article provides a starting point for anyone new to X-ray 3D virtual histology on FFPE blocks, but also serves as a useful source for more experienced users.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 78304-78316
Open AccessA Comprehensive Study of Laboratory-Based Micro-CT for 3D Virtual Histology of Human FFPE Tissue Blocks
Advances in laboratory-based X-ray computed tomography (CT) have enabled X-ray 3D virtual histology. This method shows a great potential as a complementary technique to conventional 2D histology where extensive volumetric sampling is necessary. While formalin-fixed paraffin-embedded (FFPE) tissue blocks are the backbone of clinical histology, there exists no generic optimization, and technical study of the X-ray 3D virtual histology of FFPE blocks. X-ray micro-CT of FFPE blocks is studied and optimized in their native state within the cassette to minimize the interference of X-ray 3D virtual histology with clinical workflows and standards, hence facilitating the technology transfer to the clinics. The optimization is carried on the sample positioning, tungsten tubes acceleration voltage, and artifact reduction. Then propagation-based imaging of FFPE blocks is extensively discussed. Hierarchical (local) tomography and laminography are presented as viable approaches for achieving higher spatial resolutions. In the end, future perspectives are given by considering state-of-the-art micro-CT scanners using liquid-metal-jet sources, large-area detectors, and photon counting detectors. The results achieved here are generic and can be applicable to any laboratory-based scanner with a tungsten target source and cone-beam geometry. This article provides a starting point for anyone new to X-ray 3D virtual histology on FFPE blocks, but also serves as a useful source for more experienced users.
- Open Access
- 7 February 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (03) , 031503-10
Can laboratory x-ray virtual histology provide intraoperative 3D tumor resection margin assessment?
Surgery is an essential part of the curative plan for most patients affected with solid tumors. The outcome of such tumor surgery, e.g., recurrence rates and ultimately patient survival, depends on several factors where the resection margin is of key importance. In the present paper, we show that laboratory-source-based phase-contrast x-ray imaging has potential to provide rapid intraoperative information of the resection margin.
- 7 February 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (03) , 031503-10
Open AccessCan laboratory x-ray virtual histology provide intraoperative 3D tumor resection margin assessment?
Surgery is an essential part of the curative plan for most patients affected with solid tumors. The outcome of such tumor surgery, e.g., recurrence rates and ultimately patient survival, depends on several factors where the resection margin is of key importance. In the present paper, we show that laboratory-source-based phase-contrast x-ray imaging has potential to provide rapid intraoperative information of the resection margin.
- 3 July 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (8) , 3773-3788
Quantitative predictions in small-animal X-ray fluorescence tomography
X-ray fluorescence (XRF) tomography from nanoparticles (NPs) shows promise for high-spatial-resolution molecular imaging in small-animals. Quantitative reconstruction algorithms aim to reconstruct the true distribution of NPs inside the small-animal, but so far there has been no feasible way to predict signal levels or evaluate the accuracy of reconstructions in realistic scenarios. Here we present a GPU-based computational model for small-animal XRF tomography. The unique combination of a highly accelerated Monte Carlo tool combined with an accurate small-animal phantom allows unprecedented realistic full-body simulations. We use this model to simulate our experimental system to evaluate the quantitative performance and accuracy of our reconstruction algorithms on large-scale organs as well as mm-sized tumors. Furthermore, we predict the detection limits for sub-mm tumors at realistic NP concentrations. The computational model will be a valuable tool for optimizing next-generation experimental arrangements and reconstruction algorithms.
- 3 July 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (8) , 3773-3788
Quantitative predictions in small-animal X-ray fluorescence tomography
X-ray fluorescence (XRF) tomography from nanoparticles (NPs) shows promise for high-spatial-resolution molecular imaging in small-animals. Quantitative reconstruction algorithms aim to reconstruct the true distribution of NPs inside the small-animal, but so far there has been no feasible way to predict signal levels or evaluate the accuracy of reconstructions in realistic scenarios. Here we present a GPU-based computational model for small-animal XRF tomography. The unique combination of a highly accelerated Monte Carlo tool combined with an accurate small-animal phantom allows unprecedented realistic full-body simulations. We use this model to simulate our experimental system to evaluate the quantitative performance and accuracy of our reconstruction algorithms on large-scale organs as well as mm-sized tumors. Furthermore, we predict the detection limits for sub-mm tumors at realistic NP concentrations. The computational model will be a valuable tool for optimizing next-generation experimental arrangements and reconstruction algorithms.
- Open Access
- 27 December 2018
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2018, 1-7
A Library of Potential Nanoparticle Contrast Agents for X-Ray Fluorescence Tomography Bioimaging
Nanoparticles (NPs) have been used as contrast agents for several bioimaging modalities. X-ray fluorescence (XRF) tomography can provide sensitive and quantitative 3D detection of NPs. With spectrally matched NPs as contrast agents, we demonstrated earlier in a laboratory system that XRF tomography could achieve high-spatial-resolution tumor imaging in mice. Here, we present the synthesis, characterization, and evaluation of a library of NPs containing Y, Zr, Nb, Rh, and Ru that have spectrally matched K-shell absorption for the laboratory scale X-ray source. The K-shell emissions of these NPs are spectrally well separated from the X-ray probe and the Compton background, making them suitable for the lab-scale XRF tomography system. Their potential as XRF contrast agents is demonstrated successfully in a small-animal equivalent phantom, confirming the simulation results. The diversity in the NP composition provides a flexible platform for a better design and biological optimization of XRF tomography nanoprobes.
- 27 December 2018
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2018, 1-7
Open AccessA Library of Potential Nanoparticle Contrast Agents for X-Ray Fluorescence Tomography Bioimaging
Nanoparticles (NPs) have been used as contrast agents for several bioimaging modalities. X-ray fluorescence (XRF) tomography can provide sensitive and quantitative 3D detection of NPs. With spectrally matched NPs as contrast agents, we demonstrated earlier in a laboratory system that XRF tomography could achieve high-spatial-resolution tumor imaging in mice. Here, we present the synthesis, characterization, and evaluation of a library of NPs containing Y, Zr, Nb, Rh, and Ru that have spectrally matched K-shell absorption for the laboratory scale X-ray source. The K-shell emissions of these NPs are spectrally well separated from the X-ray probe and the Compton background, making them suitable for the lab-scale XRF tomography system. Their potential as XRF contrast agents is demonstrated successfully in a small-animal equivalent phantom, confirming the simulation results. The diversity in the NP composition provides a flexible platform for a better design and biological optimization of XRF tomography nanoprobes.
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 84-85
Laboratory Nanoparticle X-Ray Fluorescence Tomography for High-Resolution Small-Animal Imaging
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 84-85
Laboratory Nanoparticle X-Ray Fluorescence Tomography for High-Resolution Small-Animal Imaging
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 100-101
Removal of Ring Artifacts in Microtomography by Characterization of Scintillator Variations - an Extension to Phase Contrast
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 100-101
Removal of Ring Artifacts in Microtomography by Characterization of Scintillator Variations - an Extension to Phase Contrast
- Open Access
- 1 August 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (16) , 164001
High-spatial-resolution x-ray fluorescence tomography with spectrally matched nanoparticles
Present macroscopic biomedical imaging methods provide either morphology with high spatial resolution (e.g. CT) or functional/molecular information with lower resolution (e.g. PET). X-ray fluorescence (XRF) from targeted nanoparticles allows molecular or functional imaging but sensitivity has so far been insufficient resulting in low spatial resolution, despite long exposure times and high dose. In the present paper, we show that laboratory XRF tomography with metal-core nanoparticles (NPs) provides a path to functional/molecular biomedical imaging with ~100 µm resolution in living rodents. The high sensitivity and resolution rely on the combination of a high-brightness liquid-metal-jet x-ray source, pencil-beam optics, photon-counting energy-dispersive detection, and spectrally matched NPs. The method is demonstrated on mice for 3D tumor imaging via passive targeting of in-house-fabricated molybdenum NPs. Exposure times, nanoparticle dose, and radiation dose agree well with in vivo imaging.
- 1 August 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (16) , 164001
Open AccessHigh-spatial-resolution x-ray fluorescence tomography with spectrally matched nanoparticles
Present macroscopic biomedical imaging methods provide either morphology with high spatial resolution (e.g. CT) or functional/molecular information with lower resolution (e.g. PET). X-ray fluorescence (XRF) from targeted nanoparticles allows molecular or functional imaging but sensitivity has so far been insufficient resulting in low spatial resolution, despite long exposure times and high dose. In the present paper, we show that laboratory XRF tomography with metal-core nanoparticles (NPs) provides a path to functional/molecular biomedical imaging with ~100 µm resolution in living rodents. The high sensitivity and resolution rely on the combination of a high-brightness liquid-metal-jet x-ray source, pencil-beam optics, photon-counting energy-dispersive detection, and spectrally matched NPs. The method is demonstrated on mice for 3D tumor imaging via passive targeting of in-house-fabricated molybdenum NPs. Exposure times, nanoparticle dose, and radiation dose agree well with in vivo imaging.
- 24 May 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (11) , 2591-2594
Focused anti-scatter grid for background reduction in x-ray fluorescence tomography
X-ray fluorescence (XRF) tomography is an emerging imaging technology with the potential for high spatial resolution molecular imaging. One of the key limitations is the background noise due to Compton scattering since it degrades the signal and limits the sensitivity. In this Letter, we present a linear focused anti-scatter grid that reduces the Compton scattering background. An anti-scatter grid was manufactured and evaluated both experimentally and theoretically with Monte Carlo simulations. The measurements showed a 31% increase in signal-to-background ratio, and simulations of an improved grid showed that this can easily be extended up to . Simulated tomographies using the improved grid show a large improvement in reconstruction quality. The anti-scatter grid will be important for in vivo XRF tomography since the background reduction allows for faster scan times, lower doses, and lower nanoparticle concentrations.- 24 May 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (11) , 2591-2594
Focused anti-scatter grid for background reduction in x-ray fluorescence tomography
X-ray fluorescence (XRF) tomography is an emerging imaging technology with the potential for high spatial resolution molecular imaging. One of the key limitations is the background noise due to Compton scattering since it degrades the signal and limits the sensitivity. In this Letter, we present a linear focused anti-scatter grid that reduces the Compton scattering background. An anti-scatter grid was manufactured and evaluated both experimentally and theoretically with Monte Carlo simulations. The measurements showed a 31% increase in signal-to-background ratio, and simulations of an improved grid showed that this can easily be extended up to . Simulated tomographies using the improved grid show a large improvement in reconstruction quality. The anti-scatter grid will be important for in vivo XRF tomography since the background reduction allows for faster scan times, lower doses, and lower nanoparticle concentrations.- 13 September 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (19) , 23191-23198
Removal of ring artifacts in microtomography by characterization of scintillator variations
Ring artifacts reduce image quality in tomography, and arise from faulty detector calibration. In microtomography, we have identified that ring artifacts can arise due to high-spatial frequency variations in the scintillator thickness. Such variations are normally removed by a flat-field correction. However, as the spectrum changes, e.g. due to beam hardening, the detector response varies non-uniformly introducing ring artifacts that persist after flat-field correction. In this paper, we present a method to correct for ring artifacts from variations in scintillator thickness by using a simple method to characterize the local scintillator response. The method addresses the actual physical cause of the ring artifacts, in contrary to many other ring artifact removal methods which rely only on image post-processing. By applying the technique to an experimental phantom tomography, we show that ring artifacts are strongly reduced compared to only making a flat-field correction.
- 13 September 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (19) , 23191-23198
Removal of ring artifacts in microtomography by characterization of scintillator variations
Ring artifacts reduce image quality in tomography, and arise from faulty detector calibration. In microtomography, we have identified that ring artifacts can arise due to high-spatial frequency variations in the scintillator thickness. Such variations are normally removed by a flat-field correction. However, as the spectrum changes, e.g. due to beam hardening, the detector response varies non-uniformly introducing ring artifacts that persist after flat-field correction. In this paper, we present a method to correct for ring artifacts from variations in scintillator thickness by using a simple method to characterize the local scintillator response. The method addresses the actual physical cause of the ring artifacts, in contrary to many other ring artifact removal methods which rely only on image post-processing. By applying the technique to an experimental phantom tomography, we show that ring artifacts are strongly reduced compared to only making a flat-field correction.
- 9 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (6Part1) , 2731-2740
Characterization of scintillator‐based detectors for few‐ten‐keV high‐spatial‐resolution x‐ray imaging
Purpose: High‐spatial‐resolution x‐ray imaging in the few‐ten‐keV range is becoming increasingly important in several applications, such as small‐animal imaging and phase‐contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator‐based detectors for this energy range and at high spatial frequencies.Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties.Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution.Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high‐resolution few‐ten‐keV imaging system for best performance.
- 9 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (6Part1) , 2731-2740
Characterization of scintillator‐based detectors for few‐ten‐keV high‐spatial‐resolution x‐ray imaging
Purpose: High‐spatial‐resolution x‐ray imaging in the few‐ten‐keV range is becoming increasingly important in several applications, such as small‐animal imaging and phase‐contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator‐based detectors for this energy range and at high spatial frequencies.Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties.Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution.Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high‐resolution few‐ten‐keV imaging system for best performance.