SSSezgi Cinel Sahin

Sezgi Cinel Sahin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sezgi Cinel Sahin has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Relationship Between Oral Hygiene Habits and The Presence of Oral Mucosal Lesions in Patients with Removable Prosthesis

    by Sezgi Cinel Şahin, Melih Özdede, Gülfem Özlü Uçan, Hasret Tanrıverdi Sahan

    Purpose: Oral mucosal lesions (OMLs) may develop in patients using removable dentures due to various local and systemic risk factors. This study aimed to assess the oral hygiene habits of patients with removable dentures, determine the prevalence of OMLs, and analyze the relationship between oral hygiene practices and the occurrence of these lesions. Material and Methods: Patients using a removable prosthesis for at least one year were included. The patients' sociodemographic characteristics, systemic condition, and oral/denture hygiene habits were assessed. Clinical findings, prosthesis stomatitis classification, and (if any) OMLs (epulis fissuratum, flabby ridge, traumatic fibroma, pseudomembranous candidiasis, angular cheilitis, frictional keratosis, traumatic ulcer), if any were evaluated. Descriptive analysis and chi-square tests were used for the analysis. Results: A significant part (n=31, 38%) of the 80 patients used the same prosthesis for 10 years or more, while 53.8% (n=43) of the participants did not receive any information from their dentists regarding prosthesis cleaning. The oral hygiene of two-thirds of the patients (n=54, 67.5%) was poor. Over half of the patients (n=43) used their dentures without interruption. More than half of the patients (n=60) had one or more OMLs. No significant relationship was found between the lesions and age or gender (p>0.05). Conclusion: The results of this study showed that most patients using removable dentures had poorly fitting dentures. Additionally, it was found that dentists do not provide adequate oral care training to their denture patients. Dentists should offer more comprehensive guidance on denture care and encourage patients to attend regular dental check-ups.

  • Open Access

    In the Third Year of the COVID‐19 Pandemic, the Worry of Applying to the Prosthodontics Clinic or Transmitting COVID‐19 to Relatives Can Cause Anxiety/Depression and Not Being Able to Wear a Mask During Treatment Can Also Cause Anxiety

    by Hatice Lamia Elif Sagesen, Sezgi Cinel Sahin, Cagri Koyal

    Objective: To evaluate the anxiety and depression levels and the factors affecting them in the patients who applied to the Prosthodontics Clinic during the end of the pandemic process with the ‘Hospital Anxiety and Depression Scale (HADS)’. Methods: To determine the symptoms of anxiety and depression, probable cause questions and the “Turkish version of the HADS” were applied to the volunteers who applied to the Prosthodontics Clinic. In the study, independent groups t‐ and one‐way ANOVA tests were used to compare the data according to the groups, the Chi‐square test was used for the relationships between group variables, and logistic regression analysis was used to determine the factors affecting anxiety and depression. Results: A total of 194 volunteers (96 male, 98 female) were included in the study. Of the participants, anxiety was detected in 42.3%, depression was detected in 58.8%, and the HADS average was measured as 15.97 ± 7.66. In the depression score classification, the difference between the depression scores of nonsmoking participants (7.8 ± 4.03) and smokers (9.07 ± 3.36) was found to be statistically significant ( p = 0.036). Applying to the prosthodontics clinic during the period when pandemic measures were reduced (OR = 2.158) and the possibility of transmitting COVID‐19 to relatives (OR = 1.816), and removing the mask during examination and treatment (OR = 2.245) were factors that increased the risk of anxiety. Applying to the prosthodontics clinic (OR = 2.757), the possibility of transmitting COVID‐19 to relatives (OR = 1.653) were factors that increased the risk of depression in participants. Conclusion: In the third year of the pandemic, we can assume that patients who have not had COVID‐19 and were smokers who applied to the prosthodontics clinic are more prone to depression. Also, it can be said that application to the prosthodontics clinic during this period and the worrying about transmitting COVID‐19 to relatives are both anxiety and depression‐increasing factors. Removing the mask during examination and treatment is an anxiety‐increasing factor.

  • Effect of Different Adhesive Resin and Composite Veneering Materials on Adhesion to Polyetheretherketone

    by Sezgi Cinel Sahin, Lamia Mutlu-Sagesen, Isil Karaokutan, Mutlu Ozcan

    Objective: To evaluate the effect of different adhesives and veneering resins on the shear bond strength (SBS) of polyetheretherketone (PEEK). Methods: A total of 138 PEEK specimens were randomly divided into 6 groups according to adhesive material application: Control (C, no application), Adhese Universal (A) (Ivoclar Vivadent, Schaan, Liechtenstein), Gluma Bond Universal (G) (Heraeus Kulzer, South Bend, IN, USA), G-PremioBOND (P) (GC Corporation, Tokyo, Japan), Single Bond Universal (S) (3M, Saint Paul, MN, USA) and visio.link (V) (Bredent, Senden, Germany). Each adhesive group was divided into two subgroups according to the type of veneering material: Estenia direct composite (D) and Gradia Plus indirect composite (IN) (both GC Corporation). After the veneering process, the specimens were aged by thermal cycling. Kruskal-Wallis and Mann-Whitney U tests were used for SBS analysis (P < 0.05). Results: The highest SBS results were obtained in the VIN group, followed by the V-D, P-D, G(IN), A(IN), A(D), S-IN, S-D, P-IN, G(D), C-IN and C-D groups, respectively (P = 0.001). There were no significant differences in terms of the type of veneering composite when the same adhesive was applied (P > 0.05), except for Gluma Bond Universal (P = 0.009). All the adhesives tested showed clinically acceptable SBS results. Conclusion: Visio.link offered the highest adhesion to PEEK, whereas the tested universal adhesives may be used as an alternative to visio.link in clinical settings. It was determined that changing the veneer type has no statistical difference when the same adhesive material is used.


  • Open Access

    Effects of polishing protocols on the surface roughness and color stability of polyetheretherketone (PEEK)

    by Sezgi Cinel Şahin, Hatice Lamia Sağesen

    This study aimed to evaluate the effects of different polishing protocols on the surface properties and color stability of the polyetheretherketone (PEEK). A total of 96 disc-shaped specimens were fabricated from PEEK material and divided into 6 different groups: control (CN), ‘‘Abraso-Starglanz’’ polishing paste (A), ‘‘Yildiz’’ polishing paste (Y), ‘‘Enhance’’ polishing system (EN), ‘‘Super snap’’ polishing kit (SS), and silicone polisher (SP). Surface roughness (Ra) were measured with a profilometer and the surface topography was examined under scanning electron microscope. Color differences were measured with a spectrophotometer according to the CIEDE2000 (∆E00) formulation before and after coffee immersion. Data were statistically analyzed with Kruskall–Wallis and Spearman's correlation analysis (p<0.05, p<0.001). A statistically significant difference was observed between the Ra measurements of the polishing protocols (p<0.001). Ra measurements except A, Y, and SS groups were found to be higher than the clinical acceptable threshold of surface roughness (0.20 μm). In ΔE00 measurements, statistically significant differences were observed between the CN and SP (p=0.041), EN (p=0.001), and A (p=0.002) polishing protocols. No correlation was found between Ra and color stability. Only in the A, Y and SS polishing protocols, Ra measurements were not found to be risky in terms of acceptable threshold of surface roughness. Polishing protocols have also generally failed to maintain the color stability. Considering the surface roughness and color stability, the ‘‘Abraso-Starglanz’’ paste may be suitable method for PEEK material.


  • The effect of different cleaning agents and resin cement materials on the bond strength of contaminated zirconia

    by Sezgi Cinel Sahin, Ersan Celik

    The purpose of this study was to examine the effect of different cleaning methods and resin cements on the shear bond strength (SBS) of contaminated zirconia. A total of 92 disc‐shaped zirconia specimens were contaminated with different procedures. Then, the specimens were grouped according to cleaning methods and resin cements: no cleaning + Variolink Esthetic DC (CNV), no cleaning + Panavia V5 (CNP), sandblasted + Variolink Esthetic DC (SBV), sandblasted + Panavia V5 (SBP), Ivoclean + Variolink Esthetic DC (ICV), Ivoclean + Panavia V5 (ICP), Katana Cleaner + Variolink Esthetic DC (KCV), and Katana Cleaner + Panavia V5 (KCP). Following an aging protocol in a 37°C for 1 week, SBS analysis was performed with a universal test machine. For the surface topography and elemental analysis, scanning electron microscopy and energy‐dispersive X‐ray spectroscopy (EDS) were used. Significance was evaluated as p < .05 and p < .01. The highest SBS results were found in the SBP group, showing a statistically significant difference from all other groups (p < .05). For the same cleaning method, Panavia V5 showed statistically significantly higher SBS values than Variolink Esthetic DC (p < .01), except the CNP–CNV (p = .880) and KCP–KCV (p = .082) groups. The most detected surface elements by EDS were Zr, O, C, and N, respectively. The contaminated zirconia surfaces must be cleaned for successful adhesion. The use of phosphate‐containing adhesives in combination with sandblasting will increase the adhesion strength, and universal cleaning agents can be a good alternative to sandblasting.


  • Evaluation of residual contamination on reused healing abutments

    by Sezgi Cinel Sahin, Kadriye Ayca Dere

    Objectives The purpose of this study is to evaluate residual contamination of healing abutments sterilized by dealers of dental implant companies. Material and methods Healing abutments collected from dealers of different implant companies were randomly numbered, and they were examined for visible deformation and contamination on the abutment surface, packaging errors, and presence of a sterilization indicator. The healing abutments were stained with a dye solution for contamination detection and evaluated by dividing into different regions. The presence of residual contamination was examined through photographic images taken from the healing abutments and the data obtained were recorded. Pearson’s chi-square analysis was used to evaluate the relation between implant brands and contamination status. Significance was evaluated as p n=176, 99.4%). The most intense staining was seen in the screw driver hole (n=172, 97.1%), body (n=113, 63.8%), occlusal (n=107, 60.4%), screw (n=79, 44.6%), and connector (n=72, 40.6%) regions, respectively. A significant relationship was found between the brands and the contamination status (p <0.05). Conclusion The reuse of healing abutments is not suitable, as it does not ensure optimum cleaning and sterilization, and it is not possible to eliminate contaminants completely. Clinical relevance Despite the economic benefits of multiple use of healing abutments, disadvantages should be carefully evaluated by clinicians.


  • Porselen laminate veneerler hakkındaki YouTube videolarının değerlendirilmesi

    by Sezgi Ci̇nEl Şahi̇n

    Amaç: Bu çalışmanın amacı, estetik dental uygulamalardan biri olan porselen laminate veneer uygulamaları hakkındaki YouTube videolarının içeriğini değerlendirmektir.Gereç ve Yöntem: ‘Porselen laminate veneer’ anahtar sözcükleri kullanılarak YouTube’da sistematik bir arama yapıldı. Videolar yükleyiciye göre sınıflandırılıp, bilgi içerikleri değerlendirildi. Video bilgileri-kalite indeksi aracılığıyla video kalitesi hesaplandı. Ayrıca videoların etkileşim ve görüntülenme oranları da analiz edildi. Elde edilen veriler, istatistiksel olarak incelendi ve anlamlılık p<0.01 ve p<0.05 düzeylerinde değerlendirildi. Bulgular: Çalışma kapsamında taranan ilk 120 video içerisinden 70 video çalışmaya dahil edildi. Video yükleyicilerine göre dağılımlar değerlendirildiğinde, en fazla videonun TV kanalları (n=17, %25.3) tarafından yüklendiği görüldü. Video yükleyicileri değişmeksizin, tüm videoların bilgi içeriğinin yetersiz olduğu tespit edildi. Protetik diş tedavisi uzmanları tarafından yüklenen videoların daha fazla izlendiği ve etkileşim oranlarının istatistiksel olarak daha yüksek olduğu (p<0.05), ancak bu videoların bilgi içeriği açısından diğer yükleyicilere ait videolardan yetersiz olduğu tespit edildi. Sonuç: Porselen laminate veneerler ile ilgili YouTube videolarının bilgi içerikleri yetersiz bulundu. En çok görüntülenen YouTube videoları, protetik diş tedavisi uzmanlarına ait olsa da bu videoların içeriklerinin bilgi akışı ve video kalitesi gibi parametreler açısından diğer yükleyicilere göre daha yetersiz olduğu tespit edildi.


  • Static and Dynamic Stress Analysis of Standard- and Narrow-Diameter Implants: A 3D Finite Element Analysis

    by Sezgi Sahin

    Sezgi Cinel Sahin, DDS: Purpose: The purpose of the three-dimensional (3D) finite element analysis study was to compare the use of titanium-zirconium (Ti-Zr) narrow-diameter implants as an alternative to titanium (Ti) or Ti-Zr standard-diameter implants in the posterior jaw regions. Materials and Methods: Ti-Zr and Ti standard-diameter implants (4.1 mm) and Ti-Zr narrow-diameter implants (3.3 mm) in cylindrical (parallel) macrodesign were simulated in the mandibular and maxillary first premolar area. Forces of 100 N were applied to the crowns in a vertical and oblique (45-degree angle to the long axis) direction. The von Mises stresses and fatigue strength values of the implants and principal stresses in the bone structures were evaluated. Results: In vertical and oblique force application, stress data in cortical and trabecular bone structures were found to be higher in 3.3-mm Ti-Zr narrow-diameter implant models than 4.1-mm Ti-Zr and Ti standard-diameter implant models. Also, the von Mises stress data of the 3.3-mm Ti-Zr narrow-diameter implants were higher than the 4.1-mm Ti-Zr and Ti standard-diameter implants. The shortest cycle of fatigue failure and estimated duration of clinical success (years) results were found in the mandibular 3.3-mm Ti-Zr implant model under oblique force, and these results remained below the identified 30-year critical threshold. Conclusion: Considering all implant models, Ti-Zr narrow-diameter implants exhibited higher stress values than Ti-Zr and Ti standard-diameter implants. In the premolar region, care should be taken biomechanically when using Ti-Zr narrow-diameter implants as an alternative to standard-diameter implants. Further comparative and in vivo studies are needed to examine the long-term success of Ti-Zr narrow-diameter implants as an alternative to standard-diameter implants.


  • Views and anxiety levels of Turkish dental students during the COVID-19 pandemic

    by Melih Özdede, Sezgi Sahin

    Introduction The novel coronavirus disease (COVID-19) has become an important public health problem that may have negative effects on psychological health. This study aims to evaluate the views and anxiety levels of dental students during COVID-19. Material and methods A questionnaire...