Failure of Emperion modular femoral stem with implant analysis
- 1 March 2016
- Published by Elsevier in Arthroplasty Today
- Vol. 2 (1) , 11-14
Open AccessFailure of Emperion modular femoral stem with implant analysis
- Open Access
- 3 June 2015
- Published by MDPI AG in Lubricants
- Vol. 3 (2) , 459-474
Evaluation of Two Total Hip Bearing Materials for Resistance to Wear Using a Hip Simulator
Electron beam crosslinked ultra high molecular weight polyethylene (UHMWPE) 32 mm cups with cobalt alloy femoral heads were compared with gamma-irradiation sterilized 26 mm cups and zirconia ceramic heads in a hip wear simulator. The testing was performed for a total of ten million cycles with frequent stops for cleaning and measurement of mass losses due to wear. The results showed that the ceramic on UHMWPE bearing design exhibited higher early wear than the metal on highly crosslinked samples. Once a steady state wear rate was reached, the wear rates of the two types of hip bearing systems were similar with the ceramic on UHMPWE samples continuing to show a slightly higher rate of wear than the highly crosslinked samples. The wear rates of each of the tested systems appear to be consistent with the expectations for low rates of wear in improved hip replacement systems.
- 3 June 2015
- Published by MDPI AG in Lubricants
- Vol. 3 (2) , 459-474
Open AccessEvaluation of Two Total Hip Bearing Materials for Resistance to Wear Using a Hip Simulator
Electron beam crosslinked ultra high molecular weight polyethylene (UHMWPE) 32 mm cups with cobalt alloy femoral heads were compared with gamma-irradiation sterilized 26 mm cups and zirconia ceramic heads in a hip wear simulator. The testing was performed for a total of ten million cycles with frequent stops for cleaning and measurement of mass losses due to wear. The results showed that the ceramic on UHMWPE bearing design exhibited higher early wear than the metal on highly crosslinked samples. Once a steady state wear rate was reached, the wear rates of the two types of hip bearing systems were similar with the ceramic on UHMPWE samples continuing to show a slightly higher rate of wear than the highly crosslinked samples. The wear rates of each of the tested systems appear to be consistent with the expectations for low rates of wear in improved hip replacement systems.
- 1 December 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (12) , 3038-3047
The use of polyurethane materials in the surgery of the spine: a review
- 1 December 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (12) , 3038-3047
The use of polyurethane materials in the surgery of the spine: a review
- 5 March 2014
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 102 (6) , 1332-1341
The use of compliant layer prosthetic components in orthopedic joint repair and replacement: A review
The surgical repair or treatment of degenerative joint disease has traditionally involved the substitution of synthetic materials for one or both surfaces of the joint. Engineering thermoplastics, metals, and ceramics have either been widely accepted or experimentally evaluated for use as bearing surfaces in these prostheses. When engineering thermoplastics are used, the opposing surface is a metal or a ceramic, but metal‐on‐metal, metal‐on‐ceramic, and ceramic‐on‐ceramic have also been used or tested. Researchers have sought the opportunity to utilize materials with compressive mechanical properties more closely matching those of the natural articular cartilage. This review discusses the theory, testing, and application of elastomers for one bearing component of articular joint prostheses. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 1332–1341, 2014.
- 5 March 2014
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 102 (6) , 1332-1341
The use of compliant layer prosthetic components in orthopedic joint repair and replacement: A review
The surgical repair or treatment of degenerative joint disease has traditionally involved the substitution of synthetic materials for one or both surfaces of the joint. Engineering thermoplastics, metals, and ceramics have either been widely accepted or experimentally evaluated for use as bearing surfaces in these prostheses. When engineering thermoplastics are used, the opposing surface is a metal or a ceramic, but metal‐on‐metal, metal‐on‐ceramic, and ceramic‐on‐ceramic have also been used or tested. Researchers have sought the opportunity to utilize materials with compressive mechanical properties more closely matching those of the natural articular cartilage. This review discusses the theory, testing, and application of elastomers for one bearing component of articular joint prostheses. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 1332–1341, 2014.
- 22 February 2011
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 27 (1) , 55-65
Evaluation of the wear performance of a polycarbonate-urethane acetabular component in a hip joint simulator and comparison with UHMWPE and cross-linked UHMWPE
Acetabular hip joint components manufactured from gamma-sterilized ultra high molecular weight polyethylene (UHMWPE), gamma cross-linked UHMWPE, or polycarbonate-urethane (PCU) polymers were evaluated in a hip joint simulator, using cobalt alloy femoral components, for at least 5 million cycles. The volume of material losses due to wear was calculated for each type of sample, based upon mass loss measurements, every 500,000 cycles. The loss of material for the conventional UHMWPE was much higher than for the cross-linked UHMWPE, showing about a 70% reduction in wear due to cross-linking. The material loss for the PCU samples appears to have been at least 24% lower than for the cross-linked UHMWPE. Based upon these results, the PCU material seems to have potential for use as an alternative bearing material to UHMWPE for total hip replacement surgeries.
- 22 February 2011
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 27 (1) , 55-65
Evaluation of the wear performance of a polycarbonate-urethane acetabular component in a hip joint simulator and comparison with UHMWPE and cross-linked UHMWPE
Acetabular hip joint components manufactured from gamma-sterilized ultra high molecular weight polyethylene (UHMWPE), gamma cross-linked UHMWPE, or polycarbonate-urethane (PCU) polymers were evaluated in a hip joint simulator, using cobalt alloy femoral components, for at least 5 million cycles. The volume of material losses due to wear was calculated for each type of sample, based upon mass loss measurements, every 500,000 cycles. The loss of material for the conventional UHMWPE was much higher than for the cross-linked UHMWPE, showing about a 70% reduction in wear due to cross-linking. The material loss for the PCU samples appears to have been at least 24% lower than for the cross-linked UHMWPE. Based upon these results, the PCU material seems to have potential for use as an alternative bearing material to UHMWPE for total hip replacement surgeries.