CCCrystal L. Coolbaugh

Crystal L. Coolbaugh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Crystal L. Coolbaugh has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Emily C. Bush

    Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA

    5 shared publications
  • Theodore F. Towse

    Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA

    5 shared publications
  • Brett Byram

    Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA

    3 shared publications
  • David Hawkins

    Biomedical Engineering Graduate Group, University of California, Davis, Davis, CA 95616, USA

    3 shared publications
  • E. Brian Welch

    Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA

    3 shared publications
  • Bruce M. Damon

    Vanderbilt University Institute of Imaging Science, Nashville, Tennessee; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee; Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee; Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, Tennessee; and

    2 shared publications

Latest Publications

  • Open Access

    Liver histology is associated with long-term clinical outcomes in patients with metabolic dysfunction–associated steatohepatitis

    by Zobair M. Younossi, Kamal Kant Mangla, Tina Landsvig Berentzen, Katrine Grau, Mette Skalshøi Kjær, Steen Ladelund, Louise Maymann Nitze, Crystal Coolbaugh, Chih-Yuan Hsu, Hannes Hagström

    Background: Few studies have examined the risk of long-term clinical outcomes in patients with metabolic dysfunction–associated steatohepatitis in relation to liver histology. We aimed to study this using a real-world cohort. Methods: Adults (N = 702) recorded on Vanderbilt University Medical Center’s Synthetic Derivative database (1984–2021) with evidence of metabolic dysfunction–associated steatohepatitis on liver biopsy were followed from the first biopsy until the first clinical event or last database entry (median: 4.7 y). Risks of cirrhosis (N = 650), other noncirrhotic liver-related (N = 702) and cardiovascular-related outcomes (N = 660), and mortality due to liver, cardiovascular, or cancer events (N = 660) were determined as a function of baseline histology (fibrosis stage [F], lobular inflammation grade [LI], hepatocyte ballooning grade [HB], and steatosis score) adjusting for sex, age, diabetes, and weight-loss surgery. Results: Cirrhosis risk was reduced for lower versus higher fibrosis stage (HR: F0–1 vs. F3: 0.22 [95% CI: 0.12–0.42]), LI1 versus LI2–3 (0.42 [0.19–0.97]), and HB1 versus HB2 (0.20 [0.08–0.50]). Lower fibrosis stage was associated with significantly lower risks of liver-related outcomes versus F4 cirrhosis (eg, F0–1: 0.12 [0.05–0.25]), whereas no differences were seen across baseline lobular inflammation, hepatocyte ballooning, and steatosis grades/scores. Lower versus higher lobular inflammation grade was associated with lower risks for liver-related outcomes in patients with weight-loss surgery. There was a trend for lower risks for cardiovascular-related and any long-term outcomes with lower versus higher fibrosis stage. Conclusions: Fibrosis stage and lobular inflammation and hepatocyte ballooning grades predict the risk of long-term outcomes, supporting the use of these histological features as potential surrogate markers of disease progression or clinical outcomes. Export


  • Quantitative Muscle Fascicle Tractography Using Brightness-Mode Ultrasound

    by Hannah Kilpatrick, Emily Bush, Carly Lockard, Xingyu Zhou, Crystal Coolbaugh, Bruce Damon

    A muscle’s architecture, defined as the geometric arrangement of its fibers with respect to its mechanical line of action, impacts its abilities to produce force and shorten or lengthen under load. Ultrasound and other noninvasive imaging methods have contributed significantly to our understanding of these structure–function relationships. The goal of this work was to develop a MATLAB toolbox for tracking and mathematically representing muscle architecture at the fascicle scale, based on brightness-mode ultrasound imaging data. The MuscleUS_Toolbox allows user-performed segmentation of a region of interest and automated modeling of local fascicle orientation; calculation of streamlines between aponeuroses of origin and insertion; and quantification of fascicle length, pennation angle, and curvature. A method is described for optimizing the fascicle orientation modeling process, and the capabilities of the toolbox for quantifying and visualizing fascicle architecture are illustrated in the human tibialis anterior muscle. The toolbox is freely available.


  • Open Access

    Cold exposure induces dynamic, heterogeneous alterations in human brown adipose tissue lipid content

    by Crystal L. Coolbaugh, Bruce M. Damon, Emily C. Bush, E. Brian Welch, Theodore F. Towse

    Brown adipose tissue undergoes a dynamic, heterogeneous response to cold exposure that can include the simultaneous synthesis, uptake, and oxidation of fatty acids. The purpose of this work was to quantify these changes in brown adipose tissue lipid content (fat-signal fraction (FSF)) using fat-water magnetic resonance imaging during individualized cooling to 3 °C above a participant’s shiver threshold. Eight healthy men completed familiarization, perception-based cooling, and MRI-cooling visits. FSF maps of the supraclavicular region were acquired in thermoneutrality and during cooling (59.5 ± 6.5 min). Brown adipose tissue regions of interest were defined, and voxels were grouped into FSF decades (0–10%, 10–20%…90–100%) according to their initial value. Brown adipose tissue contained a heterogeneous morphology of lipid content. Voxels with initial FSF values of 60–100% (P < 0.05) exhibited a significant decrease in FSF while a simultaneous increase in FSF occurred in voxels with initial FSF values of 0–30% (P < 0.05). These data suggest that in healthy young men, cold exposure elicits a dynamic and heterogeneous response in brown adipose tissue, with areas initially rich with lipid undergoing net lipid loss and areas of low initial lipid undergoing a net lipid accumulation.


  • Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol

    by Emily C. Bush, Aliya Gifford, Crystal L. Coolbaugh, Theodore F. Towse, Bruce M. Damon, E. Brian Welch

    As new techniques are developed to image adipose tissue, methods to validate such protocols are becoming increasingly important. Phantoms, experimental replicas of a tissue or organ of interest, provide a low cost, flexible solution. However, without access to expensive and specialized equipment, constructing stable phantoms with high fat fractions (e.g., >50% fat fraction levels such as those seen in brown adipose tissue) can be difficult due to the hydrophobic nature of lipids. This work presents a detailed, low cost protocol for creating 5x 100 mL phantoms with fat fractions of 0%, 25%, 50%, 75%, and 100% using basic lab supplies (hotplate, beakers, etc.) and easily accessible components (distilled water, agar, water-soluble surfactant, sodium benzoate, gadolinium-diethylenetriaminepentacetate (DTPA) contrast agent, peanut oil, and oil-soluble surfactant). The protocol was designed to be flexible; it can be used to create phantoms with different fat fractions and a wide range of volumes. Phantoms created with this technique were evaluated in the feasibility study that compared the fat fraction values from fat-water magnetic resonance imaging to the target values in the constructed phantoms. This study yielded a concordance correlation coefficient of 0.998 (95% confidence interval: 0.972-1.00). In summary, these studies demonstrate the utility of fat phantoms for validating adipose tissue imaging techniques across a range of clinically relevant tissues and organs.


  • Accelerometer-based prediction of running injury in National Collegiate Athletic Association track athletes

    by Dovin Kiernan, David A. Hawkins, Martin A.C. Manoukian, Madeline McKallip, Laura Oelsner, Charles F. Caskey, Crystal L. Coolbaugh


  • Open Access

    An Individualized, Perception-Based Protocol to Investigate Human Physiological Responses to Cooling

    by Crystal L. Coolbaugh, Emily C. Bush, Elizabeth S. Galenti, E. Brian Welch, Theodore F. Towse

    Cold exposure, a known stimulant of the thermogenic effects of brown adipose tissue (BAT), is the most widely used method to study BAT physiology in adult humans. Recently, individualized cooling has been recommended to standardize the physiological cold stress applied across participants, but critical experimental details remain unclear. The purpose of this work was to develop a detailed methodology for an individualized, perception-based protocol to investigate human physiological responses to cooling. Participants were wrapped in two water-circulating blankets and fitted with skin temperature probes to estimate BAT activity and peripheral vasoconstriction. We created a thermoesthesia graphical user interface (tGUI) to continuously record the subject's perception of cooling and shivering status during the cooling protocol. The protocol began with a 15 min thermoneutral phase followed by a series of 10 min cooling phases and concluded when sustained shivering (>1 min duration) occurred. Researchers used perception of cooling feedback (tGUI ratings) to manually adjust and personalize the water temperature at each cooling phase. Blanket water temperatures were recorded continuously during the protocol. Twelve volunteers (ages: 26.2 ± 1.4 years; 25% female) completed a feasibility study to evaluate the proposed protocol. Water temperature, perception of cooling, and shivering varied considerably across participants in response to cooling. Mean clavicle skin temperature, a surrogate measure of BAT activity, decreased (−0.99°C, 95% CI: −1.7 to −0.25°C, P = 0.16) after the cooling protocol, but an increase in supraclavicular skin temperature was observed in 4 participants. A strong positive correlation was also found between thermoesthesia and peripheral vasoconstriction (ρ = 0.84, P < 0.001). The proposed individualized, perception-based protocol therefore has potential to investigate the physiological responses to cold stress applied across populations with varying age, sex, body composition, and cold sensitivity characteristics.


  • Combining adaptive demodulation with singular value decomposition filtering for improved non-contrast perfusion ultrasound imaging

    by Brett C. Byram, Theodore Towse, Mark George, Jaime E. Tierney, Crystal Coolbaugh

    Tissue clutter caused by patient and sonographer hand motion makes perfusion ultrasound imaging difficult. We previously introduced an adaptive frequency and amplitude demodulation scheme to address this challenge. Our initial implementation used a conventional high-pass infinite impulse response (IIR) filter to attenuate the tissue signal after applying adaptive demodulation. However, other groups have shown that singular value decomposition (SVD) filtering is superior to conventional frequency domain filters. Here we evaluate the SVD filter both in comparison and in conjunction with our proposed adaptive demodulation technique. Blood-to-background SNRs were compared using power Doppler images made from single small vessel simulations with realistic tissue clutter. Additionally, filtering methods were qualitatively assessed using power Doppler images of a cut-in-half perfusion-mimicking phantom. Furthermore, in vivo power Doppler images were compared before and after muscle contraction. SVD filtering with adaptive demodulation resulted in a 7dB increase in simulated blood-to-background SNR compared to a conventional IIR filter and a 54.6% increase in power after in vivo muscle contraction compared to a 1.74% increase using a conventional IIR filter.


  • Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging

    by Jaime Tierney, Crystal Coolbaugh, Theodore Towse, Brett Byram

    Conventional Doppler ultrasound is useful for visualizing fast blood flow in large resolvable vessels. However, frame rate and tissue clutter caused by movement of the patient or sonographer make visualizing slow flow with ultrasound difficult. Patient and sonographer motion causes spectral broadening of the clutter signal, which limits ultrasound's sensitivity to velocities greater than 5-10 mm/s for typical clinical imaging frequencies. To address this, we propose a clutter filtering technique that may increase the sensitivity of Doppler measurements to at least as low as 0.52 mm/s. The proposed technique uses plane wave imaging and an adaptive frequency and amplitude demodulation scheme to decrease the bandwidth of tissue clutter. To test the performance of the adaptive demodulation method at suppressing tissue clutter bandwidths due to sonographer hand motion alone, six volunteer subjects acquired data from a stationary phantom. Additionally, to test in vivo feasibility, arterial occlusion and muscle contraction studies were performed to assess the efficiency of the proposed filter at preserving signals from blood velocities 2 mm/s or greater at a 7.8 MHz center frequency. The hand motion study resulted in initial average bandwidths of 175 Hz (8.60 mm/s), which were decreased to 10.5 Hz (0.52 mm/s) at -60 dB using our approach. The in vivo power Doppler studies resulted in 4.73 dB and 4.80 dB dynamic ranges of the blood flow with the proposed filter and 0.15 dB and 0.16 dB dynamic ranges of the blood flow with a conventional 50 Hz high-pass filter for the occlusion and contraction studies, respectively.


  • FloWave.US: validated, open-source, and flexible software for ultrasound blood flow analysis

    by Crystal L. Coolbaugh, Emily C. Bush, Charles F. Caskey, Bruce M. Damon, Theodore F. Towse

    Automated software improves the accuracy and reliability of blood velocity, vessel diameter, blood flow, and shear rate ultrasound measurements, but existing software offers limited flexibility to customize and validate analyses. We developed FloWave.US—open-source software to automate ultrasound blood flow analysis—and demonstrated the validity of its blood velocity (aggregate relative error, 4.32%) and vessel diameter (0.31%) measures with a skeletal muscle ultrasound flow phantom. Compared with a commercial, manual analysis software program, FloWave.US produced equivalent in vivo cardiac cycle time-averaged mean (TAMean) velocities at rest and following a 10-s muscle contraction (mean bias <1 pixel for both conditions). Automated analysis of ultrasound blood flow data was 9.8 times faster than the manual method. Finally, a case study of a lower extremity muscle contraction experiment highlighted the ability of FloWave.US to measure small fluctuations in TAMean velocity, vessel diameter, and mean blood flow at specific time points in the cardiac cycle. In summary, the collective features of our newly designed software—accuracy, reliability, reduced processing time, cost-effectiveness, and flexibility—offer advantages over existing proprietary options. Further, public distribution of FloWave.US allows researchers to easily access and customize code to adapt ultrasound blood flow analysis to a variety of vascular physiology applications.


  • Plane wave perfusion ultrasound imaging without contrast

    by Jaime Tierney, Crystal Coolbaugh, Theodore Towse, Brett Byram

    Perfusion imaging with conventional Doppler ultrasound is difficult due to frame rate and tissue clutter limitations. Consequently, conventional methods are only sensitive to velocities above 5-10mm/s for typical clinical imaging frequencies. To overcome this limitation and simultaneously address the frame rate and tissue clutter problems, we propose a technique that uses plane wave sequencing and an adaptive tissue clutter frequency and amplitude demodulation scheme. Suppression of tissue clutter due to sonographer hand motion was tested using phantoms and showed potential for increased Doppler sensitivity to at least as low as 1.17mm/s. Additionally, feasibility of the method is demonstrated in vivo using muscle contractions of a human calf, which resulted in 2.54dB and 0.12dB dynamic ranges of blood flow through slow-time for the proposed and conventional methods, respectively.