WGWilhelmus J. Geerts

Wilhelmus J. Geerts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wilhelmus J. Geerts has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Iodine vacancy and acetate substitution on α-FaPbI(3-x)Acy perovskite

    by Alan A.G. Santos, Nathan R. Martins, Luísa Scolfaro, Wilhelmus J. Geerts, Pablo D. Borges

  • Open Access

    Magnetic field-induced thermal behavior and sedimentation of strontium ferrite-PDMS composites for actuator applications

    by Anisul Islam, Nayeem Hasan Kashem, Wei Li, Wilhelmus J. Geerts

    Magnetic composite polymers combine the properties of both magnet and polymers which enable them to produce complex shape magnetic components. These materials have potential applications ranging microfluidics, vibration dampers, actuators, and minimally invasive medical devices, because when magnetic fields are applied to them, they can change shape precisely, quickly, and consistently. Our study investigates the behavior of strontium ferrite particles [SrO(Fe2O3)6] suspended in polydimethylsiloxane (PDMS) under the influence of gravity, applied magnetic fields, and time dependent behavior at different temperatures. We found that curing the PDMS and strontium ferrite suspension without a magnetic field result in a well-distributed particle arrangement with no coagulation. However, the particles align along the magnetic field lines while curing in the presence of a magnetic field (Hallback Cylinder), leaving a clear PDMS layer on top, while there is very little sedimentation due to gravity. To check this, we fabricated a 40 mm long sample and conducted hysteresis measurements in vibrating sample magnetometer (VSM) at various positions, showing minimal variation in magnetic saturation (Ms) values. Furthermore, we found a time-dependent curve of the transient angle as a function of temperature change, where the angle decreased over time as the particle’s magnetic moments aligned with the direction of the magnetic field. At lower temperatures, the transient angle decreased sharply due to lower dynamic viscosity in the uncured specimen. Hysteresis analysis and time-dependent studies at varying temperatures showed a notable change in curing that occurs at ∼55 °C, indicating the transition from a magneto-rheological fluid to a magnetorheological elastomer. The packing fraction of strontium ferrite particles and saturation magnetization were correlated, while coercivity was field-angle independent and remanence was field angle dependent.

  • Slot-die coating of formamidinium-cesium mixed halide perovskites in ambient conditions with FAAc additive

    by Nischal Khakurel, Drew Amyx, Maggie Yihong Chen, Yoichi Miyahara, Wilhelmus J. Geerts


  • Open Access

    Wire texture C-axis distribution of strontium ferrite/PA-12 extruded filament

    by Gabriela Espinosa-Rodriguez, Oluwasola Arigbabowo, Jonathan Alvarado, Jitendra Tate, Wilhelmus J. Geerts

    The magnetic anisotropy of strontium ferrite (SF)/PA12 filament, a popular hard magnetic ferrimagnetic composites that is used for 3D-printing of permanent magnets, is studied by vibrating sample magnetometry. The studied filaments have a composition of SF/PA-12 thermoplastic composite with a 40% wt. ratio of SF. SF particles are non-spherical platelets with an average diameter of 1.3 um and a diameter to thickness ratio of 3. Filaments are produced by a twin-screw extruder and have a diameter of 1.5 mm. SEM images show that the SF particles are homogeneously distributed through the filament. VSM measurements on different parts of the filaments show that the outer part of the cylindrical filament has a higher anisotropy, and the core is mostly isotropic. This conclusion is consistent with computational work by others which suggest that particle alignment predominantly takes place near the walls of the extruder die where shear flow is maximum. Additional hysteresis curve measurement of the outer cylindrical part of the filament parallel to the r and ϕ directions indicates that the squareness of the hysteresis curve (S) is larger in the r-direction. This indicates that the outer surface of the filament has a strong easy axis in the r-direction. We conclude that the SF platelets line up parallel to the walls of the extrusion die.


  • Open Access

    The magnetic anisotropy of field-assisted 3D printed nylon strontium ferrite composites

    by Mandesh Khadka, Oluwasola K. Arigbabowo, Jitendra S. Tate, Wilhelmus J. Geerts

    Magnetic Field Assisted Additive Manufacturing (MFAAM), 3D printing in a magnetic field, has the potential to fabricate high magnetic strength anisotropic bonded magnets. Here, 10, 35, and 54 wt% strontium ferrite bonded magnets using polyamide 12 binder were developed by twin screw compounding process and then printed via MFAAM samples in zero, and in 0.5 Tesla (H parallel to the print direction and print bed). The hysteresis curves were measured using a MicroSense EZ9 Vibrating Sample Magnetometer (VSM) for 3 different mount orientations of the sample on the sample holder to explore the magnetic anisotropy. The samples printed in zero field exhibited a weak anisotropy with an easy axis perpendicular to the print direction. This anisotropy is caused by the effect of shear flow on the orientation of the magnetic platelets in the 3D printer head. For the MFAAM samples, the S values are largest along the print bed normal. This anisotropy is caused by the field. The alignment of the magnetic particles happens when the molten suspension is in the extruder. When the material is printed, it is folded over on the print bed and its easy axis rotates 90° parallel to the print bed normally. Little realignment of the particles happens after it is printed, suggesting a sharp drop in temperature once the composite touches the print bed, indicating that field-induced effects in the nozzle dominate the anisotropy of MFAAM deposited samples.


  • Open Access

    Computational modelling of a triaxial vibrating sample magnetometer

    by Leo Rodriguez, Arjun Sapkota, Jonathan Alvarado, Jitendra S. Tate, Wilhelmus J. Geerts

    Magnetic Field Assisted Additive Manufacturing (MFAAM) enables 3D printing of magnetic materials of various shapes which exhibit a complex anisotropy energy surface containing contributions generated from different origins such as sample, particle, and agglomerate shape anisotropy, flow and field induced anisotropy, and particle crystal anisotropy. These novel magnet shapes require the need to measure the x, y, and z components of the magnetic dipole moment simultaneously to fully understand the magnetic reversal mechanism and unravel the complex magnetic anisotropy energy surface of 3D printed magnetic composites. This work aims to develop a triaxial vibrating sample magnetometer (VSM) by adding a z-coil set to a pre-existing biaxial VSM employing a modified Mallison coil set. The optimum size and location of the sensing coils were determined by modeling the sensitivity matrix of the z-coil set. The designed coil set was implemented using 3D printed spools, a manual coil winder, and gauge 38 copper wire. A 3D printed strontium ferrite nylon composite sample was used to estimate the sensitivity of the z-coils (50 mV/emu). The results herein are applicable for any VSM using a modified Mallison biaxial coil configuration allowing for a quick implementation on pre-existing systems.


  • Open Access

    On the origin of systematic errors in VSM torque curves

    by Arjun Sapkota, Leo Rodriguez, Binod D. C., Kolton Dieckow, Chandan Q. Howlader, Wilhelmus J. Geerts, Jitendra Tate

    Magnetic anisotropy (MA) is a basic and crucial magnetic property which describes how the magnetic properties change with field angle in a magnetic composite. Torque measurements are normally used to measure a sample’s anisotropy constant and can be determined directly using a torque magnetometer (TM) or indirectly using a vibrating sample magnetometer (VSM). Most TM only operate at room temperature. However, a biaxial VSM allows straightforward torque measurements at varying temperatures. VSM torque curves comprise a 2θ background caused by small misalignments of the sample on the sample rod, and/or a non-azimuthal symmetric sample shape. These errors originate from the position dependence of the pickup coil sensitivity matrix. Here, the magnetic torque of a strontium ferrite/PA-12 3D printed samples was explored using biaxial VSM and compared to measurements done with a true torque magnetometer. Torque curves were taken from 16-22kOe every 2kOe on a 4.8 mm wire and a 1.23 mm dot sample using a MicroSense EZ9 VSM. Fourier analysis was used to determine the second harmonics from each torque curve. The biaxial torque curves of the wire samples have a much larger torque amplitude which is mainly due to the crosstalk of the y-coil set. Crosstalk originates from the non-azimuthal symmetric shape of the sample and due to the wobble originating from small sample misalignments on the sample rod. Background can be minimized by using samples with near cylindrical symmetry and using a microscope when mounting the sample on the sample rod.


  • Kinematic modeling and design of untethered soft mobile magnetic robots with multiple support sections

    by Amanda de Oliveira Barros, Nayeem Hasan Kashem, Daniel Luna, Wilhelmus J. Geerts, Wei Li, James Yang