JNJunko Nakahira

Junko Nakahira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junko Nakahira has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of alveolar recruitment maneuver on respiratory resistance during general anesthesia: a prospective observational study

    by Junko Nakahira, Shoko Nakano, Toshiaki Minami

    Background: Alveolar recruitment maneuvers enable easily reopening nonaerated lung regions via a transient elevation in transpulmonary pressure. To evaluate the effect of these maneuvers on respiratory resistance, we used an oscillatory technique during mechanical ventilation. This study was conducted to assess the effect of the alveolar recruitment maneuvers on respiratory resistance under routine anesthesia. We hypothesized that respiratory resistance at 5 Hz (R5) after the maneuver would be decreased after the lung aeration.Methods: After receiving the ethics committee’s approval, we enrolled 33 patients who were classified with an American Society of Anesthesiologists physical status of 1, 2 or 3 and were undergoing general anesthesia for transurethral resection of a bladder tumor within a 12-month period from 2017 to 2018. The recruitment maneuver was performed 30 min after endotracheal intubation. The maneuver consisted of sustained manual inflation of the anesthesia reservoir bag to a peak inspiratory pressure of 40 cmH2O for 15 s, including 5 s of gradually increasing the peak inspiratory pressure. Respiratory resistance was measured using the forced oscillation technique before and after the maneuver, and the mean R5 was calculated during the expiratory phase. The respiratory resistance and ventilator parameter results were analyzed using paired Student’st-tests, andp < 0.05 was considered statistically significant.Results: We analyzed 31 patients (25 men and 6 women). R5 was 7.3 ± 1.6 cmH2O/L/sec before the recruitment maneuver during mechanical ventilation and was significantly decreased to 6.4 ± 1.7 cmH2O/L/sec after the maneuver. Peak inspiratory pressure and plateau pressure were significantly decreased, and pulmonary compliance was increased, although the values were not clinically relevant.Conclusion: The recruitment maneuver decreased respiratory resistance and increased lung compliance during mechanical ventilation.Trial registration: Name of registry: Japan Medical Association Center for Clinical Trials.Trial registration number: reference JMA-IIA00136.Date of registration: 2 September 2013.URL of trial registry record:https://dbcentre3.jmacct.med.or.jp/JMACTR/App/JMACTRE02_04/JMACTRE02_04.aspx?kbn=3&seqno=3582


  • Efficacy of Goreisan in Preventing Transurethral Resection Syndrome in Transurethral Resection of the Prostate: A Randomized-Controlled Study

    by Atsushi Fujiwara, Junko Nakahira, Shoko Nakano, Toshiyuki Sawai, Toshiaki Minami

    Objectives: Nonconductive irrigation fluids used during transurethral resection (TUR) of the prostate can cause fluid overload and dilutional hyponatremia. TUR syndrome is generally defined as serum sodium at or below 125 mmol/L with cardiovascular and neurologic symptoms. The aim of this study was to evaluate the effects of Goreisan, a traditional Japanese Kampo medicine, on serum sodium levels and the occurrence of TUR syndrome in patients undergoing TUR of the prostate. Design: This was a randomized-controlled trial. Settings/Location: This trial was conducted at the Osaka Medical College Hospital and Keneikai Sanko Hospital. Subjects: Fifty patients scheduled for TUR of the prostate were included. Interventions: Patients in the Goreisan group (n = 23) received 2.5 g Goreisan orally on the night before surgery and on the morning of surgery. The control group (n = 27) did not receive Goreisan. Surgical procedures, perioperative management, and patient monitoring were otherwise the same in both groups. Outcome Measures: The primary outcome was occurrence of TUR syndrome. The secondary outcome was serum sodium level. Results: Serum sodium remained above 125 mmol/L in all patients, so none of the patients met the criteria for TUR syndrome. However, the Goreisan group had significantly higher intraoperative sodium levels (p < 0.001) and significantly higher intraoperative (p = 0.008) and postoperative (p = 0.02) hemoglobin levels than the control group. Conclusions: These findings indicate that preoperative Goreisan administration can help maintain serum sodium levels in patients undergoing TUR of the prostate.


  • Open Access

    Factors Associated with Poor Satisfaction with Anesthesia in Patients Who Had Previous Surgery: A Retrospective Study

    by Junko Nakahira, Toshiyuki Sawai, Junichi Ishio, Shoko Nakano, Toshiaki Minami

    As most studies investigating patient satisfaction with anesthesia have some bias, previous results may underrepresent the true level of dissatisfaction wit ...


  • Open Access

    Changes in cardiac function and hemodynamics during robot-assisted laparoscopic prostatectomy with steep head-down tilt: a prospective observational study

    by Naomi Ono, Junko Nakahira, Shoko Nakano, Toshiyuki Sawai, Toshiaki Minami

    Objective: Robot-assisted laparoscopic prostatectomy requires the patient to be placed in a steep head-down tilt. The aim of our study was to investigate changes in cardiac index and left ventricular end-diastolic volume in a steep had-down tilt. This is a prospective observational study. We investigated the influence of steep head-down tilt on cardiac function and hemodynamics without fluid restriction in 12 men of American Society of Anesthesiologists physical status I–II undergoing robot-assisted laparoscopic prostatectomy. We measured left ventricular ejection fraction, left ventricular end-diastolic volume and cardiac index by transesophageal echocardiography, cardiac index using a FloTrac® sensor, heart rate and arterial blood pressure, before and 5 min after tilting the operating table. Results: The following variables changed significantly after tilting and establishment of the pneumoperitoneum: left ventricular ejection fraction (before 62.5%, after 55.5%; P = 0.040), systolic blood pressure (before 116 mmHg, after 128 mmHg; P = 0.001) and diastolic blood pressure (before 59 mmHg, after 70 mmHg; P = 0.002). There were no significant changes in cardiac index or left ventricular end-diastolic volume measured by transesophageal echocardiography, or cardiac index by FloTrac® sensor. Left ventricular ejection fraction decreased, whereas cardiac index and left ventricular end-diastolic volume did not change, indicating that steep head-down tilt and pneumoperitoneum during robot-assisted laparoscopic prostatectomy did not greatly influence cardiac function. This study was registered as a clinical study with the Japanese Official Clinical Trial Registry (Trial Registration Number JMA-IIA00158 on 7th January, 2014)


  • Open Access

    Factors Causing Post-Anesthetic High Respiratory Resistance in Patients Undergoing Transurethral Resection of Bladder Tumors

    by Junko Nakahira, Shoko Nakano, Toshiyuki Sawai, Junichi Ishio, Naomi Ono, Toshiaki Minami

    Background: In this study, we investigated the causes of high respiratory resistance that is observed after general anesthesia. We focused on respiratory resistance at 5 Hz (R5), which were measured preoperatively and postoperatively. Methods: Our prospective observational study enrolled 68 patients who underwent transurethral resection of bladder tumors from April to October 2015. Respiratory impedance was measured the day before surgery and immediately after general anesthesia. Participants were divided into 2 groups: Group L (postoperative R5 values < 4.0 cmH2O/L/sec; n = 33) and Group H (postoperative R5 values ≥ 4.0 cmH2O/L/sec; n = 35). Patient background, preoperative R5 values, endotracheal tube or subglottic devices, anaesthetic period, desflurane or sevoflurane, and endotracheal suctioning were compared. Results: Significant parameters were height, inhalation of desflurane, endotracheal suctioning, and preoperative R5 value. Logistic regression showed that endotracheal suctioning and a higher preoperative R5 level increased postoperative respiratory resistance (> 4 cmH2O/L/sec). Conclusions: The endotracheal suctioning at the end of anesthesia influenced respiratory resistance more than use of the endotracheal tube and desflurane. Keywords: Forced Oscillation Technique; Respiratory Impedance; Ventilator-Induced Lung Injury; Mechanical Ventilation; General Anesthesia


  • Open Access

    The Effects of Endotracheal Tube and i-gel® Supraglottic Airway Device on Respiratory Impedance: A Prospective Observational Study

    by Shoko Nakano, Junko Nakahira, Yosuke Kuzukawa, Toshiyuki Sawai, Toshiaki Minami

    Background: The forced oscillation technique (FOT) is a non-invasive means of measuring respiratory resistance and reactance. We tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in FOT parameters than a supraglottic airway device (SGD). Methods: Forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder tumor resection underwent spirometry the day before surgery. Forced oscillation was measured using a MostGraph-01 device the day before surgery and immediately after removal of the airway adjunct. Changes in respiratory resistance and reactance were compared between those intubated and those who used SGD. Results: The trachea was intubated in 23 patients and SGD was used in the remaining 17 patients. Both airway adjuncts caused significant increases in preoperative respiratory resistance and reactance; however, the magnitude of the changes was significantly greater in the intubated patients. Conclusions: The SGD appears to cause less pulmonary injury than tracheal intubation. Further study is needed to illuminate the influence of mechanical ventilation, and longer-term consequences and clinical significance of the changes we found in this study. Spontaneous ventilation through an SGD may be preferable in patients with severe respiratory disease. Keywords: Forced Oscillation Technique; Respiratory Impedance; Endotracheal Intubation; Supraglottic Airway Device


  • Open Access

    Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report

    by Naomi Ono, Junko Nakahira, Sayuri Matsunami, Toshiyuki Sawai, Toshiaki Minami

    Background: Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct the catheter placement. Case Presentation: A 74-year-old male underwent mitral valve plasty for cardiac failure caused by mitral valve regurgitation. Preoperative transthoracic echocardiography showed no septal shunt. The pulmonary artery was catheterized through a sheath introducer in the right jugular vein, and the balloon was inflated after insertion of a 15-cm catheter. The catheter was advanced until a pulmonary artery waveform was detected and the pulmonary artery wedge pressure was 21 mmHg at end-expiration. The balloon was deflated and the catheter tip was pulled back 3 cm. Pulmonary artery waveforms and appropriate a and v waves were detected, and transesophageal echocardiography confirmed the location of the catheter tip in the right pulmonary artery. The first collected blood sample had an oxygen partial pressure of 358.8 mmHg, carbon dioxide partial pressure of 20.1 mmHg, and oxygen saturation of 99%, indicating pulmonary venous blood. The pulmonary artery catheter was pulled back 5 cm, but a second blood sample showed the same results. The catheter was pulled back a further 6 cm while the location of the catheter tip was monitored on X-ray fluoroscopy. Blood gas testing through the catheter tip showed oxygen saturation of 84.4 % and oxygen partial pressure of 41.6 mmHg. Surgery was performed uneventfully. Postoperative chest radiographs showed proper placement of the pulmonary artery catheter, but radiographs on postoperative day 1 showed over-insertion, although the insertion length was unchanged. The catheter was removed. The patient was discharged 2 months postoperatively. Conclusions: Our case highlights the fact that the tip of the pulmonary artery catheter can easily advance into a peripheral branch of the pulmonary artery and cause pulmonary venous blood to be sampled instead of pulmonary arterial blood. A variety of monitoring techniques are needed to confirm accurate catheter placement. Keywords: Pulmonary Artery Catheter; Blood Sampling; Pulmonary Artery; Blood Sampling; Pulmonary Artery; Case Report

  • Open Access

    Unexpected hemorrhage during robot-assisted laparoscopic prostatectomy: a case report

    by Shoko Nakano, Junko Nakahira, Toshiyuki Sawai, Noriko Kadono, Toshiaki Minami

    Robot-assisted laparoscopic prostatectomy is increasingly performed as a minimally invasive option for patients with organ-confined prostate cancer. This technique offers several advantages over other surgical methods. However, concerns have been raised over the effects of the steep head-down tilt necessary during the procedure. We present a case in which head-down positioning and abdominal insufflation masked the signs of an intraoperative hemorrhage. A 73-year-old Asian man developed severe hypotension caused by an unexpected hemorrhage during robot-assisted laparoscopic prostatectomy for prostate cancer. Although our patient’s blood pressure steadily decreased during the procedure, his systolic blood pressure remained above 80 mmHg while he was tilted head downward at an angle of 28°. However, his blood pressure dropped immediately after he was returned to the horizontal position and abdominal insufflation – to create a pneumoperitoneum – was ceased at the end of surgery. We returned the patient to a head-down tilt to keep his blood pressure stable and began fluid infusion. Blood test results indicated that a hemorrhage was the cause of his hypotension. Open abdominal surgery was performed to stop the bleeding. The surgeons found blood pooling inside his abdomen from a longitudinal cut in a small arterial vessel in his abdominal wall, possibly a branch of his external iliac artery. The surgeons successfully controlled the hemorrhage and our patient was moved to our intensive care unit. Our patient recovered completely over the next few days, without any neurological deficits. We suspect that blood began to pool in our patient’s superior abdomen during surgery, and that increased intra-abdominal pressure suppressed the hemorrhage. When our patient was returned to the horizontal position and insufflation of his abdomen was discontinued, the resulting increased rate of hemorrhage caused a sudden drop in blood pressure. Surgeons and anesthesiologists must understand the hemodynamic changes that result from head-down patient positioning and abdominal insufflation.


  • Open Access

    Movement of Intravascular Air Bubble during Esophagectomy

    by Junko Nakahira

    MedWin is an open access Publishers on the latest research in the fields of Dental, pediatrics, diabetes, ophthalmology, Orthopedics, Biotechnology, virology.