Ning Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ning Zhou has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Lixue Dong
Affiliation Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, United States of America
8 shared publicationsBryan E. Pfingst
Department of Otolaryngology, Kresge Hearing Research Institute, University of Michigan, Ann Arbor, Michigan 48109-5616, USA
3 shared publicationsSusannah Dixon
Affiliation Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, United States of America
3 shared publications- John J. Galvin
House Inst. Foundation, 1127 Wilshire Blvd., Ste. 1620, Los Angeles, CA 90017
2 shared publications Juliana Mathews
Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, United States
2 shared publications- Li Xu
Ohio University
2 shared publications
Latest Publications
- Open Access
- 8 June 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (6) , e0269652
Perception of speaker sincerity in complex social interactions by cochlear implant users
Understanding insincere language (sarcasm and teasing) is a fundamental part of communication and crucial for maintaining social relationships. This can be a challenging task for cochlear implant (CIs) users who receive degraded suprasegmental information important for perceiving a speaker’s attitude. We measured the perception of speaker sincerity (literal positive, literal negative, sarcasm, and teasing) in 16 adults with CIs using an established video inventory. Participants were presented with audio-only and audio-visual social interactions between two people with and without supporting verbal context. They were instructed to describe the content of the conversation and answer whether the speakers meant what they said. Results showed that subjects could not always identify speaker sincerity, even when the content of the conversation was perfectly understood. This deficit was greater for perceiving insincere relative to sincere utterances. Performance improved when additional visual cues or verbal context cues were provided. Subjects who were better at perceiving the content of the interactions in the audio-only condition benefited more from having additional visual cues for judging the speaker’s sincerity, suggesting that the two modalities compete for cognitive recourses. Perception of content also did not correlate with perception of speaker sincerity, suggesting that what was said vs. how it was said were perceived using unrelated segmental versus suprasegmental cues. Our results further showed that subjects who had access to lower-order resolved harmonic information provided by hearing aids in the contralateral ear identified speaker sincerity better than those who used implants alone. These results suggest that measuring speech recognition alone in CI users does not fully describe the outcome. Our findings stress the importance of measuring social communication functions in people with CIs.
- 8 June 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (6) , e0269652
Open AccessPerception of speaker sincerity in complex social interactions by cochlear implant users
Understanding insincere language (sarcasm and teasing) is a fundamental part of communication and crucial for maintaining social relationships. This can be a challenging task for cochlear implant (CIs) users who receive degraded suprasegmental information important for perceiving a speaker’s attitude. We measured the perception of speaker sincerity (literal positive, literal negative, sarcasm, and teasing) in 16 adults with CIs using an established video inventory. Participants were presented with audio-only and audio-visual social interactions between two people with and without supporting verbal context. They were instructed to describe the content of the conversation and answer whether the speakers meant what they said. Results showed that subjects could not always identify speaker sincerity, even when the content of the conversation was perfectly understood. This deficit was greater for perceiving insincere relative to sincere utterances. Performance improved when additional visual cues or verbal context cues were provided. Subjects who were better at perceiving the content of the interactions in the audio-only condition benefited more from having additional visual cues for judging the speaker’s sincerity, suggesting that the two modalities compete for cognitive recourses. Perception of content also did not correlate with perception of speaker sincerity, suggesting that what was said vs. how it was said were perceived using unrelated segmental versus suprasegmental cues. Our results further showed that subjects who had access to lower-order resolved harmonic information provided by hearing aids in the contralateral ear identified speaker sincerity better than those who used implants alone. These results suggest that measuring speech recognition alone in CI users does not fully describe the outcome. Our findings stress the importance of measuring social communication functions in people with CIs.
- Open Access
- 1 May 2022
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 2 (5) , 055201
Acoustic analysis of tone production in Mandarin-speaking bimodal cochlear implant users
The benefit of using a hearing aid with a cochlear implant (bimodal hearing) has been demonstrated for tone perception under certain conditions. The present study evaluated bimodal effects for tone production by comparing performance between a bimodal and a unimodal implant group. Results showed that acoustic differentiation of tones produced by the bimodal group was better than the unimodal implant group, and performance was dependent on the subject's acoustic thresholds but not related to implant experience or age at implantation. The findings support the use of amplified acoustic hearing in conjunction with the implant for better development of pitch production.
- 1 May 2022
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 2 (5) , 055201
Open AccessAcoustic analysis of tone production in Mandarin-speaking bimodal cochlear implant users
The benefit of using a hearing aid with a cochlear implant (bimodal hearing) has been demonstrated for tone perception under certain conditions. The present study evaluated bimodal effects for tone production by comparing performance between a bimodal and a unimodal implant group. Results showed that acoustic differentiation of tones produced by the bimodal group was better than the unimodal implant group, and performance was dependent on the subject's acoustic thresholds but not related to implant experience or age at implantation. The findings support the use of amplified acoustic hearing in conjunction with the implant for better development of pitch production.
- Open Access
- 8 February 2021
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 22 (2) , 177-192
Sensitivity to Pulse Phase Duration as a Marker of Neural Health Across Cochlear Implant Recipients and Electrodes
In cochlear implants, loudness has been shown to grow more slowly with increasing pulse phase duration (PPD) than with pulse amplitude (PA), possibly due to “leaky” charge integration. This leakiness has been recently quantified in terms of “charge integration efficiency,” defined as the log difference between the PPD dynamic range and PA dynamic range (both expressed in charge units), relative to a common threshold anchor. Such leakiness may differ across electrodes and/or test ears, and may reflect underlying neural health. In this study, we examined the across-site variation of charge integration in recipients of Cochlear© devices. PPD and PA dynamic ranges were measured relative to two threshold anchors with either a 25- or 50-microsecond PPD. Strength-duration functions, previously shown to relate to survival of spiral ganglion cells and peripheral processes, were compared to charge integration efficiency on selected electrodes. Results showed no significant or systematic relationship between the across-site variation in charge integration efficiency and electrode position or threshold levels. Charge integration efficiency was poorer with the 50-μs threshold anchor, suggesting that greater leakiness was associated with larger PPD dynamic ranges. Poorer and more variable charge integration efficiency across electrodes was associated with longer duration of any hearing loss, consistent with the idea that poor integration is related to neural degeneration. More variable integration efficiency was also associated with poorer speech recognition performance across test ears. The slopes of the strength-duration functions at maximum acceptable loudness were significantly correlated with charge integration efficiency. However, the strength-duration slopes were not predictive of duration of any hearing loss or speech recognition performance in our participants. As such, charge integration efficiency may be a better candidate to measure leakiness in neural populations across the electrode array, as well as the general health of the auditory nerve in human cochlear implant recipients.
- 8 February 2021
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 22 (2) , 177-192
Open AccessSensitivity to Pulse Phase Duration as a Marker of Neural Health Across Cochlear Implant Recipients and Electrodes
In cochlear implants, loudness has been shown to grow more slowly with increasing pulse phase duration (PPD) than with pulse amplitude (PA), possibly due to “leaky” charge integration. This leakiness has been recently quantified in terms of “charge integration efficiency,” defined as the log difference between the PPD dynamic range and PA dynamic range (both expressed in charge units), relative to a common threshold anchor. Such leakiness may differ across electrodes and/or test ears, and may reflect underlying neural health. In this study, we examined the across-site variation of charge integration in recipients of Cochlear© devices. PPD and PA dynamic ranges were measured relative to two threshold anchors with either a 25- or 50-microsecond PPD. Strength-duration functions, previously shown to relate to survival of spiral ganglion cells and peripheral processes, were compared to charge integration efficiency on selected electrodes. Results showed no significant or systematic relationship between the across-site variation in charge integration efficiency and electrode position or threshold levels. Charge integration efficiency was poorer with the 50-μs threshold anchor, suggesting that greater leakiness was associated with larger PPD dynamic ranges. Poorer and more variable charge integration efficiency across electrodes was associated with longer duration of any hearing loss, consistent with the idea that poor integration is related to neural degeneration. More variable integration efficiency was also associated with poorer speech recognition performance across test ears. The slopes of the strength-duration functions at maximum acceptable loudness were significantly correlated with charge integration efficiency. However, the strength-duration slopes were not predictive of duration of any hearing loss or speech recognition performance in our participants. As such, charge integration efficiency may be a better candidate to measure leakiness in neural populations across the electrode array, as well as the general health of the auditory nerve in human cochlear implant recipients.
- Open Access
- 20 July 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (7) , e0236179
Effect of pulse phase duration on forward masking and spread of excitation in cochlear implant listeners
Previous cochlear implant (CI) research has shown that at a pulse train with a long pulse phase duration (PPD) requires less current but greater charge to obtain the same loudness as a pulse train with a short PPD. This might result in different excitation patterns between long and short PPDs. At equal loudness, long PPDs might produce greater masking due to greater charge. However, because they require less current, long PPDs may produce a smaller spatial spread of excitation (SOE) compared to short PPDs by evoking a greater neural firing probability within the relatively small current field. To investigate the effects of PPD on excitation patterns, overall masking and SOE were compared for equally loud stimuli with short or long PPD in 10 adult CI ears. Forward masking patterns were measured at relatively soft, medium, and loud presentation levels. Threshold shifts were calculated in terms of percent dynamic range (DR) of the probe. The area under the curve (AUC) of the masking functions was significantly larger for the long PPD than for the short PPD masker. The difference in AUC was proportional to the difference in charge between the short and long PPD maskers. To estimate SOE, the masking patterns were first normalized to the peak masking, and then AUC was calculated. SOE was significantly larger for the short PPD than for the long PPD masker. Thus, at equal loudness, long PPDs produced greater overall masking (possibly due to greater charge) but less SOE (possibly due to less current spread) than did short PPDs. The effect of the interaction between masking and SOE by long PPD stimulation remains to be tested.
- 20 July 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (7) , e0236179
Open AccessEffect of pulse phase duration on forward masking and spread of excitation in cochlear implant listeners
Previous cochlear implant (CI) research has shown that at a pulse train with a long pulse phase duration (PPD) requires less current but greater charge to obtain the same loudness as a pulse train with a short PPD. This might result in different excitation patterns between long and short PPDs. At equal loudness, long PPDs might produce greater masking due to greater charge. However, because they require less current, long PPDs may produce a smaller spatial spread of excitation (SOE) compared to short PPDs by evoking a greater neural firing probability within the relatively small current field. To investigate the effects of PPD on excitation patterns, overall masking and SOE were compared for equally loud stimuli with short or long PPD in 10 adult CI ears. Forward masking patterns were measured at relatively soft, medium, and loud presentation levels. Threshold shifts were calculated in terms of percent dynamic range (DR) of the probe. The area under the curve (AUC) of the masking functions was significantly larger for the long PPD than for the short PPD masker. The difference in AUC was proportional to the difference in charge between the short and long PPD maskers. To estimate SOE, the masking patterns were first normalized to the peak masking, and then AUC was calculated. SOE was significantly larger for the short PPD than for the long PPD masker. Thus, at equal loudness, long PPDs produced greater overall masking (possibly due to greater charge) but less SOE (possibly due to less current spread) than did short PPDs. The effect of the interaction between masking and SOE by long PPD stimulation remains to be tested.
- 1 April 2020
- Published by Elsevier in Hearing Research
- Vol. 389, 107921
Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation
- 1 April 2020
- Published by Elsevier in Hearing Research
- Vol. 389, 107921
Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation
- Open Access
- 1 January 2020
- Published by SAGE Publications in Trends in Hearing
- Vol. 24
Spectrotemporal Modulation Sensitivity in Cochlear-Implant and Normal-Hearing Listeners: Is the Performance Driven by Temporal or Spectral Modulation Sensitivity?
This study examined the contribution of temporal and spectral modulation sensitivity to discrimination of stimuli modulated in both the time and frequency domains. The spectrotemporally modulated stimuli contained spectral ripples that shifted systematically across frequency over time at a repetition rate of 5 Hz. As the ripple density increased in the stimulus, modulation depth of the 5 Hz amplitude modulation (AM) reduced. Spectrotemporal modulation discrimination was compared with subjects’ ability to discriminate static spectral ripples and the ability to detect slow AM. The general pattern from both the cochlear implant (CI) and normal hearing groups showed that spectrotemporal modulation thresholds were correlated more strongly with AM detection than with static ripple discrimination. CI subjects’ spectrotemporal modulation thresholds were also highly correlated with speech recognition in noise, when partialing out static ripple discrimination, but the correlation was not significant when partialing out AM detection. The results indicated that temporal information was more heavily weighted in spectrotemporal modulation discrimination, and for CI subjects, it was AM sensitivity that drove the correlation between spectrotemporal modulation thresholds and speech recognition. The results suggest that for the rates tested here, temporal information processing may limit performance more than spectral information processing in both CI users and normal hearing listeners.
- 1 January 2020
- Published by SAGE Publications in Trends in Hearing
- Vol. 24
Open AccessSpectrotemporal Modulation Sensitivity in Cochlear-Implant and Normal-Hearing Listeners: Is the Performance Driven by Temporal or Spectral Modulation Sensitivity?
This study examined the contribution of temporal and spectral modulation sensitivity to discrimination of stimuli modulated in both the time and frequency domains. The spectrotemporally modulated stimuli contained spectral ripples that shifted systematically across frequency over time at a repetition rate of 5 Hz. As the ripple density increased in the stimulus, modulation depth of the 5 Hz amplitude modulation (AM) reduced. Spectrotemporal modulation discrimination was compared with subjects’ ability to discriminate static spectral ripples and the ability to detect slow AM. The general pattern from both the cochlear implant (CI) and normal hearing groups showed that spectrotemporal modulation thresholds were correlated more strongly with AM detection than with static ripple discrimination. CI subjects’ spectrotemporal modulation thresholds were also highly correlated with speech recognition in noise, when partialing out static ripple discrimination, but the correlation was not significant when partialing out AM detection. The results indicated that temporal information was more heavily weighted in spectrotemporal modulation discrimination, and for CI subjects, it was AM sensitivity that drove the correlation between spectrotemporal modulation thresholds and speech recognition. The results suggest that for the rates tested here, temporal information processing may limit performance more than spectral information processing in both CI users and normal hearing listeners.
- 23 April 2019
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 58 (9) , 587-597
Longitudinal effect of deactivating stimulation sites based on low-rate thresholds on speech recognition in cochlear implant users
Objective: The objective of the current study was to examine the longitudinal effect of deactivating stimulation sites estimated to produce broad neural excitation on speech recognition. Design: Spatial patterns of neural excitation were estimated based on a previously established psychophysical measure, that is, detection threshold for low-rate pulse trains. Stimulation sites with relatively poor thresholds were deactivated in an experimental map. The acute effect was evaluated, in quiet and in noise, immediately after the experimental map was created (baseline), after the subjects practiced with the experimental map for two months (treatment), and after the subjects’ daily map was switched back again to the clinical map for another two months (withdrawal). Study sample: Eight Cochlear Nucleus device users participated in the study. Results: For both listening in noise and in quiet, the greatest effect of deactivation was observed after the subjects were given time to adapt to the new frequency allocations. The effect was comparable for listening in fluctuating and steady-state noises. All subjects benefited from deactivation for listening in noise, but subjects with greater variability in thresholds were more likely to benefit from deactivation for listening in quiet. Conclusion: The benefit of electrode deactivation for speech recognition can increase with practice.
- 23 April 2019
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 58 (9) , 587-597
Longitudinal effect of deactivating stimulation sites based on low-rate thresholds on speech recognition in cochlear implant users
Objective: The objective of the current study was to examine the longitudinal effect of deactivating stimulation sites estimated to produce broad neural excitation on speech recognition. Design: Spatial patterns of neural excitation were estimated based on a previously established psychophysical measure, that is, detection threshold for low-rate pulse trains. Stimulation sites with relatively poor thresholds were deactivated in an experimental map. The acute effect was evaluated, in quiet and in noise, immediately after the experimental map was created (baseline), after the subjects practiced with the experimental map for two months (treatment), and after the subjects’ daily map was switched back again to the clinical map for another two months (withdrawal). Study sample: Eight Cochlear Nucleus device users participated in the study. Results: For both listening in noise and in quiet, the greatest effect of deactivation was observed after the subjects were given time to adapt to the new frequency allocations. The effect was comparable for listening in fluctuating and steady-state noises. All subjects benefited from deactivation for listening in noise, but subjects with greater variability in thresholds were more likely to benefit from deactivation for listening in quiet. Conclusion: The benefit of electrode deactivation for speech recognition can increase with practice.
- 1 January 2019
- Published by Elsevier in Hearing Research
- Vol. 371, 1-10
Pulse-rate discrimination deficit in cochlear implant users: is the upper limit of pitch peripheral or central?
- 1 January 2019
- Published by Elsevier in Hearing Research
- Vol. 371, 1-10
Pulse-rate discrimination deficit in cochlear implant users: is the upper limit of pitch peripheral or central?
- 25 April 2018
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 19 (3) , 317-330
Temporal Modulation Detection Depends on Sharpness of Spatial Tuning
Prior research has shown that in electrical hearing, cochlear implant (CI) users’ speech recognition performance is related in part to their ability to detect temporal modulation (i.e., modulation sensitivity). Previous studies have also shown better speech recognition when selectively stimulating sites with good modulation sensitivity rather than all stimulation sites. Site selection based on channel interaction measures, such as those using imaging or psychophysical estimates of spread of neural excitation, has also been shown to improve speech recognition. This led to the question of whether temporal modulation sensitivity and spatial selectivity of neural excitation are two related variables. In the present study, CI users’ modulation sensitivity was compared for sites with relatively broad or narrow neural excitation patterns. This was achieved by measuring temporal modulation detection thresholds (MDTs) at stimulation sites that were significantly different in their sharpness of the psychophysical spatial tuning curves (PTCs) and measuring MDTs at the same sites in monopolar (MP) and bipolar (BP) stimulation modes. Nine postlingually deafened subjects implanted with Cochlear Nucleus® device took part in the study. Results showed a significant correlation between the sharpness of PTCs and MDTs, indicating that modulation detection benefits from a more spatially restricted neural activation pattern. There was a significant interaction between stimulation site and mode. That is, using BP stimulation only improved MDTs at stimulation sites with broad PTCs but had no effect or sometimes a detrimental effect on MDTs at stimulation sites with sharp PTCs. This interaction could suggest that a criterion number of nerve fibers is needed to achieve optimal temporal resolution, and, to achieve optimized speech recognition outcomes, individualized selection of site-specific current focusing strategies may be necessary. These results also suggest that the removal of stimulation sites measured with poor MDTs might improve both temporal and spectral resolution.
- 25 April 2018
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 19 (3) , 317-330
Temporal Modulation Detection Depends on Sharpness of Spatial Tuning
Prior research has shown that in electrical hearing, cochlear implant (CI) users’ speech recognition performance is related in part to their ability to detect temporal modulation (i.e., modulation sensitivity). Previous studies have also shown better speech recognition when selectively stimulating sites with good modulation sensitivity rather than all stimulation sites. Site selection based on channel interaction measures, such as those using imaging or psychophysical estimates of spread of neural excitation, has also been shown to improve speech recognition. This led to the question of whether temporal modulation sensitivity and spatial selectivity of neural excitation are two related variables. In the present study, CI users’ modulation sensitivity was compared for sites with relatively broad or narrow neural excitation patterns. This was achieved by measuring temporal modulation detection thresholds (MDTs) at stimulation sites that were significantly different in their sharpness of the psychophysical spatial tuning curves (PTCs) and measuring MDTs at the same sites in monopolar (MP) and bipolar (BP) stimulation modes. Nine postlingually deafened subjects implanted with Cochlear Nucleus® device took part in the study. Results showed a significant correlation between the sharpness of PTCs and MDTs, indicating that modulation detection benefits from a more spatially restricted neural activation pattern. There was a significant interaction between stimulation site and mode. That is, using BP stimulation only improved MDTs at stimulation sites with broad PTCs but had no effect or sometimes a detrimental effect on MDTs at stimulation sites with sharp PTCs. This interaction could suggest that a criterion number of nerve fibers is needed to achieve optimal temporal resolution, and, to achieve optimized speech recognition outcomes, individualized selection of site-specific current focusing strategies may be necessary. These results also suggest that the removal of stimulation sites measured with poor MDTs might improve both temporal and spectral resolution.