Saeed Zahedi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Saeed Zahedi has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- David Moser
Chas A Blatchford & Sons Ltd, Basingstoke United Kingdom of Great Britain and Northern Ireland RG22 4AH
4 shared publications - David Moser
Blatchford Group, Unit D Antura, Bond Close, Basingstoke, UK
3 shared publications - Michael McGrath
Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK
3 shared publications - Alexander Dickinson
University of Southampton
2 shared publications - Andrea Giovanni Cutti
Centro Protesi Inail, Vigorso di Budrio, 40054 Bologna, Italy
2 shared publications Aopa Socket Guidance Workgroup
Department of Industrial Engineering, University of Padua, Padua (PD), Italy
2 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (10) , e0358882
Lower limb prosthetic users’ activity classification through real-world inertial sensing
The prescription of lower limb prosthetics relies heavily on the assigned K-level. K-level assessment has been criticised for subjectivity and variability, potentially leading to inappropriate component selection and poorer functional outcomes. This study presents an original methodology for objectively determining activity levels from inertial sensor data, developed through rigorous data collection on 20 amputees who walked on various types of outdoor terrain (flat ground, stairs, ramp, grass/uneven/unstable surfaces), with and without a walking aid. Advanced machine learning algorithms were applied to the real-world IMU data, to establish a validated classification model for daily activity outside the laboratory. A random forest classifier achieved a mean leave‑some‑out accuracy of 65.70% (SD 6.6%; 95% CI 47.3–84.1%) and cross‑validation accuracy of 85.65% (SD 0.79%; 95% CI 83.4–87.9%). Per‑class sensitivity ranged from approximately 44–78% in leave‑some‑out analyses, with lower performance for ramp ascending and descending. The difference between cross‑validation and leave‑some‑out accuracies indicates participant‑specific overfitting, so the leave‑some‑out accuracy is considered the current conservative estimate of performance on unseen users and the cross-validation accuracy an estimate of potential accuracy with a more robust dataset. The research subsequently incorporated a preliminary clinical evaluation of the approach on a subset of 3 amputees using a data collection protocol for unsupervised, longitudinal real-world monitoring, with preliminary insight into perceived clinical significance of outcomes ascertained through exploratory interviews with 4 prescribing health care professionals. The findings suggest potential benefits of real-world inertial sensing, supporting a move from primarily subjective clinical assessment toward more objective, data-driven activity classification. This research demonstrates that an evidence-based tool for enhancing K-level prescription could in future provide more appropriate component selection and improve long-term mobility for prosthetic users, but current accuracies and sample sizes indicate that the system should be viewed as a promising proof‑of‑concept rather than a definitive tool for changing K‑level prescription.
- 9 October 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (10) , e0358882
Open AccessLower limb prosthetic users’ activity classification through real-world inertial sensing
The prescription of lower limb prosthetics relies heavily on the assigned K-level. K-level assessment has been criticised for subjectivity and variability, potentially leading to inappropriate component selection and poorer functional outcomes. This study presents an original methodology for objectively determining activity levels from inertial sensor data, developed through rigorous data collection on 20 amputees who walked on various types of outdoor terrain (flat ground, stairs, ramp, grass/uneven/unstable surfaces), with and without a walking aid. Advanced machine learning algorithms were applied to the real-world IMU data, to establish a validated classification model for daily activity outside the laboratory. A random forest classifier achieved a mean leave‑some‑out accuracy of 65.70% (SD 6.6%; 95% CI 47.3–84.1%) and cross‑validation accuracy of 85.65% (SD 0.79%; 95% CI 83.4–87.9%). Per‑class sensitivity ranged from approximately 44–78% in leave‑some‑out analyses, with lower performance for ramp ascending and descending. The difference between cross‑validation and leave‑some‑out accuracies indicates participant‑specific overfitting, so the leave‑some‑out accuracy is considered the current conservative estimate of performance on unseen users and the cross-validation accuracy an estimate of potential accuracy with a more robust dataset. The research subsequently incorporated a preliminary clinical evaluation of the approach on a subset of 3 amputees using a data collection protocol for unsupervised, longitudinal real-world monitoring, with preliminary insight into perceived clinical significance of outcomes ascertained through exploratory interviews with 4 prescribing health care professionals. The findings suggest potential benefits of real-world inertial sensing, supporting a move from primarily subjective clinical assessment toward more objective, data-driven activity classification. This research demonstrates that an evidence-based tool for enhancing K-level prescription could in future provide more appropriate component selection and improve long-term mobility for prosthetic users, but current accuracies and sample sizes indicate that the system should be viewed as a promising proof‑of‑concept rather than a definitive tool for changing K‑level prescription.
- 1 June 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 49 (3) , 257-259
How does the content of the 20th I.S.P.O. World Congress align with the United Nations Sustainable Development Goals?
- 1 June 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 49 (3) , 257-259
How does the content of the 20th I.S.P.O. World Congress align with the United Nations Sustainable Development Goals?
- Open Access
- 9 February 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (1) , 3-12
Mechanical testing of transtibial prosthetic sockets: A discussion paper from the American Orthotic and Prosthetic Association Socket Guidance Workgroup
Background: The advent of novel manufacturing technologies, materials, and socket design concepts could introduce risks to prosthetic limb users, as the existing knowledge base for safe fabrication may not apply. Moreover, although structural test standards exist for mass-produced prosthetic components, they are not applicable to prosthetic sockets. Methods: The “AOPA Socket Guidance Workgroup” was formed in 2020 to provide the prosthetic community with evidence-based clinical best practices and methods in the field of prosthetic socket structural analysis. This multidisciplinary expert workgroup undertook a critical analysis of the knowledge gaps regarding the requirements for mechanical testing of lower limb prosthetic sockets. Results: The Workgroup identified knowledge gaps in 4 domains. Domain 1 describes the shape and composition of a mock residual limb, required to support and generate in vivo representative loading within the socket. Domain 2 concerns prosthetic socket coordinate systems and alignment. Domain 3 regards the components and requirements of test specimens. Finally, Domain 4 considers test conditions, loading parameters, and acceptance criteria. Conclusions: This paper describes these knowledge gaps in detail and recommends potential solution approaches based on literature review, group consensus around existing knowledge, or the formation of new study groups to fill each knowledge gap. Our intent is for the recommendations arising from this paper to support the community (e.g., researchers in the clinic, academia, industry, and funders) in addressing these knowledge gaps.
- 9 February 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (1) , 3-12
Open AccessMechanical testing of transtibial prosthetic sockets: A discussion paper from the American Orthotic and Prosthetic Association Socket Guidance Workgroup
Background: The advent of novel manufacturing technologies, materials, and socket design concepts could introduce risks to prosthetic limb users, as the existing knowledge base for safe fabrication may not apply. Moreover, although structural test standards exist for mass-produced prosthetic components, they are not applicable to prosthetic sockets. Methods: The “AOPA Socket Guidance Workgroup” was formed in 2020 to provide the prosthetic community with evidence-based clinical best practices and methods in the field of prosthetic socket structural analysis. This multidisciplinary expert workgroup undertook a critical analysis of the knowledge gaps regarding the requirements for mechanical testing of lower limb prosthetic sockets. Results: The Workgroup identified knowledge gaps in 4 domains. Domain 1 describes the shape and composition of a mock residual limb, required to support and generate in vivo representative loading within the socket. Domain 2 concerns prosthetic socket coordinate systems and alignment. Domain 3 regards the components and requirements of test specimens. Finally, Domain 4 considers test conditions, loading parameters, and acceptance criteria. Conclusions: This paper describes these knowledge gaps in detail and recommends potential solution approaches based on literature review, group consensus around existing knowledge, or the formation of new study groups to fill each knowledge gap. Our intent is for the recommendations arising from this paper to support the community (e.g., researchers in the clinic, academia, industry, and funders) in addressing these knowledge gaps.
- 8 February 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (1) , 1-2
Toward standardized methods for prosthetic socket mechanical testing
- 8 February 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (1) , 1-2
Toward standardized methods for prosthetic socket mechanical testing
- Open Access
- 4 January 2021
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 4 (1)
USING A SWEATING RESIDUUM/SOCKET INTERFACE SIMULATOR FOR THE EVALUATION OF SWEAT MANAGEMENT LINERS IN LOWER LIMB PROSTHETICS
BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects. Layman’s Abstract Simulators can be used in prosthetics research to make experiments more repeatable. In this study, a test apparatus was created to replicate the mechanical effects of residual limb sweating. An artificial residual limb was made from silicone and a 3D printed, transtibial bone model. Small holes were made throughout the silicone to act like pores, allowing water to travel to the outside surface, like sweat. The limb was loaded to mimic walking and its movement within the socket was measured. For some tests, water was added internally to see the effect of sweat. Two types of liner were used and compared; a standard one and one with perforations. In terms of movement, the results were generally consistent between each cycle for the dry tests. For standard liners, the addition of sweating increased the variability of movement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on movement (0.04mm v 0.04mm, p=0.497). The test apparatus simulated the effect of residual limb sweating. The findings indicate that moisture on the skin can lead to inconsistent movement, but perforated liners help to remove this moisture, which helps improve consistency of performance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/35213/27472 How To Cite: McGrath M, Davies K.C, Gallego A, Laszczak P, Tang J, Zahedi S, Moser D. Using a sweating residuum/socket interface simulator for the evaluation of sweat management liners in lower limb prosthetics. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.3. https://doi.org/10.33137/cpoj.v4i1.35213 Corresponding Author: Dr. Michael McGrath, PhDResearch Scientist–Clinical Evidence,Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, United Kingdom.Email: mike.mcgrath@blatchford.co.ukORCID: https://orcid.org/0000-0003-0195-970X
- 4 January 2021
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 4 (1)
Open AccessUSING A SWEATING RESIDUUM/SOCKET INTERFACE SIMULATOR FOR THE EVALUATION OF SWEAT MANAGEMENT LINERS IN LOWER LIMB PROSTHETICS
BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects. Layman’s Abstract Simulators can be used in prosthetics research to make experiments more repeatable. In this study, a test apparatus was created to replicate the mechanical effects of residual limb sweating. An artificial residual limb was made from silicone and a 3D printed, transtibial bone model. Small holes were made throughout the silicone to act like pores, allowing water to travel to the outside surface, like sweat. The limb was loaded to mimic walking and its movement within the socket was measured. For some tests, water was added internally to see the effect of sweat. Two types of liner were used and compared; a standard one and one with perforations. In terms of movement, the results were generally consistent between each cycle for the dry tests. For standard liners, the addition of sweating increased the variability of movement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on movement (0.04mm v 0.04mm, p=0.497). The test apparatus simulated the effect of residual limb sweating. The findings indicate that moisture on the skin can lead to inconsistent movement, but perforated liners help to remove this moisture, which helps improve consistency of performance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/35213/27472 How To Cite: McGrath M, Davies K.C, Gallego A, Laszczak P, Tang J, Zahedi S, Moser D. Using a sweating residuum/socket interface simulator for the evaluation of sweat management liners in lower limb prosthetics. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.3. https://doi.org/10.33137/cpoj.v4i1.35213 Corresponding Author: Dr. Michael McGrath, PhDResearch Scientist–Clinical Evidence,Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, United Kingdom.Email: mike.mcgrath@blatchford.co.ukORCID: https://orcid.org/0000-0003-0195-970X
- Open Access
- 3 September 2020
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 3 (2)
USING PERFORATED LINERS TO COMBAT THE DETRIMENTAL EFFECTS OF EXCESSIVE SWEATING IN LOWER LIMB PROSTHESIS USERS
BACKGROUND: Excessive sweating of the residual limb has a substantial effect on the daily activities of people with lower limb amputation. Prosthetic liners offer protection and comfort to sensitive areas but often exacerbate perspiration. They act as insulators, trapping sweat on the skin’s surface to the detriment of skin health. Recently, liners with perforations have been developed, allowing the moisture to escape. The goal of this study was to assess the impact of such liners. METHODS: A sample group of 13 patients with unilateral transtibial amputation, who wore a perforated liner (PL) as part of their current prescription, was compared to 20 control patients who wore non-perforated liners (NPL). During their routine appointments, they completed a survey of scientifically validated outcome measures relating to their limb health, pain and the impact on daily life over a 12-month period. RESULTS: Patients using the PL had healthier residual limbs, reporting higher scores on questions relating to limb health, experiencing fewer skin issues (p<0.001) and estimating a 61.8% lower rating in perceived sweat (p=0.004). Perhaps consequentially, there was a lower incidence of residual (p=0.012) and phantom (p=0.001) limb pain when compared to the control group. The prevalence of individual issues affecting the residual limbs of PL users was also lower. Of the issues that remained, only 23% were attributed to sweating in PL users, compared to 49% for the NPL group (p=0.066). PL users missed fewer days of work in the year (2.4 vs 11.6, p=0.267) and were also limited on fewer days (1.4 vs 75.4, p=0.009). CONCLUSION: The use of perforated liners shows much promise within prosthetic care, significantly improving the health of the residual limb. The observed effects on perceived sweat reduction, residual skin health, pain levels and patient limitation suggest that perforated liners are highly beneficial to patients. Layman's Abstract Individuals with amputation often find that they sweat more as they exert more energy when walking and because the total surface area of their body is reduced. Silicone liners are used to cushion the residual limb and as a way of attaching a prosthetic leg, but they act as insulators causing the residual limb to get hot and sweaty. The material isn’t breathable, so the sweat is not able to escape, instead staying on the skin’s surface and causing discomfort or leading to the development of skin conditions. Liners that have small holes in them allow sweat to travel away from the body and preserve skin health. Patients who wore a perforated liner, as well as patients who wore a liner without holes, filled in questionnaires about their experience, the results of which were compared. Generally, patients who wore the perforated liner had healthier skin on their residual limbs and experienced fewer skin conditions than the other patient group. Out of the issues they did experience, fewer were attributed to sweating. The study group experienced less frequent pain both in their physical and phantom limbs. They also considered themselves less limited by their prosthetic device and missed fewer days of work. These observations suggest that perforated liners are highly beneficial to patients within the prosthetic field. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/34610/26579 How To Cite: Davies K.C, McGrath M, Savage Z, Stenson A, Moser D, Zahedi S. Using perforated liners to combat the detrimental effects of excessive sweating in lower limb prosthesis users. Canadian Prosthetics & Orthotics Journal. 2020;Volume 3, Issue 2, No.1. https://doi.org/10.33137/cpoj.v3i2.34610 Corresponding Author: K.C Davies, Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK.E-mail: katherine.davies@blatchford.co.ukORCID: https://orcid.org/0000-0003-2933-4365
- 3 September 2020
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 3 (2)
Open AccessUSING PERFORATED LINERS TO COMBAT THE DETRIMENTAL EFFECTS OF EXCESSIVE SWEATING IN LOWER LIMB PROSTHESIS USERS
BACKGROUND: Excessive sweating of the residual limb has a substantial effect on the daily activities of people with lower limb amputation. Prosthetic liners offer protection and comfort to sensitive areas but often exacerbate perspiration. They act as insulators, trapping sweat on the skin’s surface to the detriment of skin health. Recently, liners with perforations have been developed, allowing the moisture to escape. The goal of this study was to assess the impact of such liners. METHODS: A sample group of 13 patients with unilateral transtibial amputation, who wore a perforated liner (PL) as part of their current prescription, was compared to 20 control patients who wore non-perforated liners (NPL). During their routine appointments, they completed a survey of scientifically validated outcome measures relating to their limb health, pain and the impact on daily life over a 12-month period. RESULTS: Patients using the PL had healthier residual limbs, reporting higher scores on questions relating to limb health, experiencing fewer skin issues (p<0.001) and estimating a 61.8% lower rating in perceived sweat (p=0.004). Perhaps consequentially, there was a lower incidence of residual (p=0.012) and phantom (p=0.001) limb pain when compared to the control group. The prevalence of individual issues affecting the residual limbs of PL users was also lower. Of the issues that remained, only 23% were attributed to sweating in PL users, compared to 49% for the NPL group (p=0.066). PL users missed fewer days of work in the year (2.4 vs 11.6, p=0.267) and were also limited on fewer days (1.4 vs 75.4, p=0.009). CONCLUSION: The use of perforated liners shows much promise within prosthetic care, significantly improving the health of the residual limb. The observed effects on perceived sweat reduction, residual skin health, pain levels and patient limitation suggest that perforated liners are highly beneficial to patients. Layman's Abstract Individuals with amputation often find that they sweat more as they exert more energy when walking and because the total surface area of their body is reduced. Silicone liners are used to cushion the residual limb and as a way of attaching a prosthetic leg, but they act as insulators causing the residual limb to get hot and sweaty. The material isn’t breathable, so the sweat is not able to escape, instead staying on the skin’s surface and causing discomfort or leading to the development of skin conditions. Liners that have small holes in them allow sweat to travel away from the body and preserve skin health. Patients who wore a perforated liner, as well as patients who wore a liner without holes, filled in questionnaires about their experience, the results of which were compared. Generally, patients who wore the perforated liner had healthier skin on their residual limbs and experienced fewer skin conditions than the other patient group. Out of the issues they did experience, fewer were attributed to sweating. The study group experienced less frequent pain both in their physical and phantom limbs. They also considered themselves less limited by their prosthetic device and missed fewer days of work. These observations suggest that perforated liners are highly beneficial to patients within the prosthetic field. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/34610/26579 How To Cite: Davies K.C, McGrath M, Savage Z, Stenson A, Moser D, Zahedi S. Using perforated liners to combat the detrimental effects of excessive sweating in lower limb prosthesis users. Canadian Prosthetics & Orthotics Journal. 2020;Volume 3, Issue 2, No.1. https://doi.org/10.33137/cpoj.v3i2.34610 Corresponding Author: K.C Davies, Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK.E-mail: katherine.davies@blatchford.co.ukORCID: https://orcid.org/0000-0003-2933-4365
- 17 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 24 (3) , 1011-1022
The Design, Control, and Testing of an Integrated Electrohydrostatic Powered Ankle Prosthesis
This paper presents a prototype powered ankle prosthesis which can operate passively in most of the gait cycle and provide powered assistance for toe push-off and subsequent foot dorsiflexion. The use of electrohydrostatic actuation (EHA) gives the ability to switch quickly and smoothly between passive and active modes. In this new powered ankle prosthesis, the motor-pump unit is integrated with the ankle joint and the battery and controller are held in a backpack. A 100W brushless DC motor is used to drive a 0.45cc/rev gear pump, controlling flow to an ankle cylinder through a bespoke manifold. The motor runs wet, pressurised to 6MPa, avoiding the need for a pump shaft seal and a refeeding circuit for external leakage. A dynamic system model has been develop to help analyse the EHA performance. A motor control method is proposed based on heel strike recognition and a middle stance time delay. The prosthesis has been tested with a 70kg transtibial amputee, and results are presented for walking on a treadmill at three different speeds (2.8, 3.8 and 4.8 km/h). The amputee has provided positive subjective feedback. We conclude that the hybrid passive-active approach has significant advantages for prosthesis design, and we outline future testing and development requirements.
- 17 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 24 (3) , 1011-1022
The Design, Control, and Testing of an Integrated Electrohydrostatic Powered Ankle Prosthesis
This paper presents a prototype powered ankle prosthesis which can operate passively in most of the gait cycle and provide powered assistance for toe push-off and subsequent foot dorsiflexion. The use of electrohydrostatic actuation (EHA) gives the ability to switch quickly and smoothly between passive and active modes. In this new powered ankle prosthesis, the motor-pump unit is integrated with the ankle joint and the battery and controller are held in a backpack. A 100W brushless DC motor is used to drive a 0.45cc/rev gear pump, controlling flow to an ankle cylinder through a bespoke manifold. The motor runs wet, pressurised to 6MPa, avoiding the need for a pump shaft seal and a refeeding circuit for external leakage. A dynamic system model has been develop to help analyse the EHA performance. A motor control method is proposed based on heel strike recognition and a middle stance time delay. The prosthesis has been tested with a 70kg transtibial amputee, and results are presented for walking on a treadmill at three different speeds (2.8, 3.8 and 4.8 km/h). The amputee has provided positive subjective feedback. We conclude that the hybrid passive-active approach has significant advantages for prosthesis design, and we outline future testing and development requirements.
- Open Access
- 15 December 2018
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
PERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE
INTRODUCTION For many years, the biomechanical evaluation of prosthetic performance has centred around gait analysis and motion capture. While this provides useful, scientific insights, everyday life is not limited to straight-line, level, steady-state walking. With advancements in portable sensor technology in the last two decades, long-term activity monitoring (AM) has become a more feasible and reliable prospect for accurately representing the real-world walking behaviour of patients. Modern microprocessor knees (MPKs) have begun to have this functionality built into the devices themselves, without the necessity for additional, external hardware. Abstract PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/32031/24448 How to cite: Sykes A, Stech N, Laszczak P, McGrath M, Kercher A, Zahedi S, Moser D. PERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE. CANADIAN PROSTHETICS & ORTHOTICS JOURNAL, VOLUME 1, ISSUE 2, 2018; ABSTRACT, ORAL PRESENTATION AT THE AOPA’S 101ST NATIONAL ASSEMBLY, SEPT. 26-29, VANCOUVER, CANADA, 2018. DOI: https://doi.org/10.33137/cpoj.v1i2.32031 Abstracts were Peer-reviewed by the American Orthotic Prosthetic Association (AOPA) 101st National Assembly Scientific Committee. http://www.aopanet.org/
- 15 December 2018
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Open AccessPERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE
INTRODUCTION For many years, the biomechanical evaluation of prosthetic performance has centred around gait analysis and motion capture. While this provides useful, scientific insights, everyday life is not limited to straight-line, level, steady-state walking. With advancements in portable sensor technology in the last two decades, long-term activity monitoring (AM) has become a more feasible and reliable prospect for accurately representing the real-world walking behaviour of patients. Modern microprocessor knees (MPKs) have begun to have this functionality built into the devices themselves, without the necessity for additional, external hardware. Abstract PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/32031/24448 How to cite: Sykes A, Stech N, Laszczak P, McGrath M, Kercher A, Zahedi S, Moser D. PERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE. CANADIAN PROSTHETICS & ORTHOTICS JOURNAL, VOLUME 1, ISSUE 2, 2018; ABSTRACT, ORAL PRESENTATION AT THE AOPA’S 101ST NATIONAL ASSEMBLY, SEPT. 26-29, VANCOUVER, CANADA, 2018. DOI: https://doi.org/10.33137/cpoj.v1i2.32031 Abstracts were Peer-reviewed by the American Orthotic Prosthetic Association (AOPA) 101st National Assembly Scientific Committee. http://www.aopanet.org/
- 23 October 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (1) , 132-137
Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications
A novel capacitance-based sensor designed for monitoring mechanical stresses at the stump-socket interface of lower-limb amputees is described. It provides practical means of measuring pressure and shear stresses simultaneously. In particular, it comprises of a flexible frame (20 mm × 20 mm), with thickness of 4mm. By employing rapid prototyping technology in its fabrication, it offers a low-cost and versatile solution, with capability of adopting bespoke shapes of lower-limb residua. The sensor was first analysed using finite element analysis (FEA) and then evaluated using lab-based electromechanical tests. The results validate that the sensor is capable of monitoring both pressure and shear at stresses up to 350 kPa and 80 kPa, respectively. A post-signal processing model is developed to induce pressure and shear stresses, respectively. The effective separation of pressure and shear signals can be potentially advantageous for sensor calibration in clinical applications. The sensor also demonstrates high linearity (approx. 5-8%) and high pressure (approx. 1.3 kPa) and shear (approx. 0.6 kPa) stress resolution performance. Accordingly, the sensor offers the potential for exploitation as an assistive tool to both evaluate prosthetic socket fitting in clinical settings and alert amputees in home settings of excessive loading at the stump-socket interface, effectively preventing stump tissue breakdown at an early stage.
- 23 October 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (1) , 132-137
Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications
A novel capacitance-based sensor designed for monitoring mechanical stresses at the stump-socket interface of lower-limb amputees is described. It provides practical means of measuring pressure and shear stresses simultaneously. In particular, it comprises of a flexible frame (20 mm × 20 mm), with thickness of 4mm. By employing rapid prototyping technology in its fabrication, it offers a low-cost and versatile solution, with capability of adopting bespoke shapes of lower-limb residua. The sensor was first analysed using finite element analysis (FEA) and then evaluated using lab-based electromechanical tests. The results validate that the sensor is capable of monitoring both pressure and shear at stresses up to 350 kPa and 80 kPa, respectively. A post-signal processing model is developed to induce pressure and shear stresses, respectively. The effective separation of pressure and shear signals can be potentially advantageous for sensor calibration in clinical applications. The sensor also demonstrates high linearity (approx. 5-8%) and high pressure (approx. 1.3 kPa) and shear (approx. 0.6 kPa) stress resolution performance. Accordingly, the sensor offers the potential for exploitation as an assistive tool to both evaluate prosthetic socket fitting in clinical settings and alert amputees in home settings of excessive loading at the stump-socket interface, effectively preventing stump tissue breakdown at an early stage.