David Moser
Research Subjects
Research Interests
David Moser has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Michael McGrath
Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK
3 shared publications - Saeed Zahedi
Blatchford, Basingstoke, United Kingdom
3 shared publications - Katherine C. Davies
Affiliation Sheffield Teaching Hospitals, Sheffield, South Yorkshire, United Kingdom
2 shared publications - Piotr Laszczak
Blatchford Group, Unit D Antura, Bond Close, Basingstoke, UK
2 shared publications A. Kazemzadeh
BAE SYSTEMS, Manassas, VA, USA
1 shared publicationAlan Kercher
Endolite North America, Miamisburg, OH, USA
1 shared publication
Latest Publications
- Open Access
- 4 January 2021
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 4 (1)
USING A SWEATING RESIDUUM/SOCKET INTERFACE SIMULATOR FOR THE EVALUATION OF SWEAT MANAGEMENT LINERS IN LOWER LIMB PROSTHETICS
BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects. Layman’s Abstract Simulators can be used in prosthetics research to make experiments more repeatable. In this study, a test apparatus was created to replicate the mechanical effects of residual limb sweating. An artificial residual limb was made from silicone and a 3D printed, transtibial bone model. Small holes were made throughout the silicone to act like pores, allowing water to travel to the outside surface, like sweat. The limb was loaded to mimic walking and its movement within the socket was measured. For some tests, water was added internally to see the effect of sweat. Two types of liner were used and compared; a standard one and one with perforations. In terms of movement, the results were generally consistent between each cycle for the dry tests. For standard liners, the addition of sweating increased the variability of movement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on movement (0.04mm v 0.04mm, p=0.497). The test apparatus simulated the effect of residual limb sweating. The findings indicate that moisture on the skin can lead to inconsistent movement, but perforated liners help to remove this moisture, which helps improve consistency of performance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/35213/27472 How To Cite: McGrath M, Davies K.C, Gallego A, Laszczak P, Tang J, Zahedi S, Moser D. Using a sweating residuum/socket interface simulator for the evaluation of sweat management liners in lower limb prosthetics. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.3. https://doi.org/10.33137/cpoj.v4i1.35213 Corresponding Author: Dr. Michael McGrath, PhDResearch Scientist–Clinical Evidence,Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, United Kingdom.Email: mike.mcgrath@blatchford.co.ukORCID: https://orcid.org/0000-0003-0195-970X
- 4 January 2021
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 4 (1)
Open AccessUSING A SWEATING RESIDUUM/SOCKET INTERFACE SIMULATOR FOR THE EVALUATION OF SWEAT MANAGEMENT LINERS IN LOWER LIMB PROSTHETICS
BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects. Layman’s Abstract Simulators can be used in prosthetics research to make experiments more repeatable. In this study, a test apparatus was created to replicate the mechanical effects of residual limb sweating. An artificial residual limb was made from silicone and a 3D printed, transtibial bone model. Small holes were made throughout the silicone to act like pores, allowing water to travel to the outside surface, like sweat. The limb was loaded to mimic walking and its movement within the socket was measured. For some tests, water was added internally to see the effect of sweat. Two types of liner were used and compared; a standard one and one with perforations. In terms of movement, the results were generally consistent between each cycle for the dry tests. For standard liners, the addition of sweating increased the variability of movement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on movement (0.04mm v 0.04mm, p=0.497). The test apparatus simulated the effect of residual limb sweating. The findings indicate that moisture on the skin can lead to inconsistent movement, but perforated liners help to remove this moisture, which helps improve consistency of performance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/35213/27472 How To Cite: McGrath M, Davies K.C, Gallego A, Laszczak P, Tang J, Zahedi S, Moser D. Using a sweating residuum/socket interface simulator for the evaluation of sweat management liners in lower limb prosthetics. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.3. https://doi.org/10.33137/cpoj.v4i1.35213 Corresponding Author: Dr. Michael McGrath, PhDResearch Scientist–Clinical Evidence,Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, United Kingdom.Email: mike.mcgrath@blatchford.co.ukORCID: https://orcid.org/0000-0003-0195-970X
- Open Access
- 3 September 2020
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 3 (2)
USING PERFORATED LINERS TO COMBAT THE DETRIMENTAL EFFECTS OF EXCESSIVE SWEATING IN LOWER LIMB PROSTHESIS USERS
BACKGROUND: Excessive sweating of the residual limb has a substantial effect on the daily activities of people with lower limb amputation. Prosthetic liners offer protection and comfort to sensitive areas but often exacerbate perspiration. They act as insulators, trapping sweat on the skin’s surface to the detriment of skin health. Recently, liners with perforations have been developed, allowing the moisture to escape. The goal of this study was to assess the impact of such liners. METHODS: A sample group of 13 patients with unilateral transtibial amputation, who wore a perforated liner (PL) as part of their current prescription, was compared to 20 control patients who wore non-perforated liners (NPL). During their routine appointments, they completed a survey of scientifically validated outcome measures relating to their limb health, pain and the impact on daily life over a 12-month period. RESULTS: Patients using the PL had healthier residual limbs, reporting higher scores on questions relating to limb health, experiencing fewer skin issues (p<0.001) and estimating a 61.8% lower rating in perceived sweat (p=0.004). Perhaps consequentially, there was a lower incidence of residual (p=0.012) and phantom (p=0.001) limb pain when compared to the control group. The prevalence of individual issues affecting the residual limbs of PL users was also lower. Of the issues that remained, only 23% were attributed to sweating in PL users, compared to 49% for the NPL group (p=0.066). PL users missed fewer days of work in the year (2.4 vs 11.6, p=0.267) and were also limited on fewer days (1.4 vs 75.4, p=0.009). CONCLUSION: The use of perforated liners shows much promise within prosthetic care, significantly improving the health of the residual limb. The observed effects on perceived sweat reduction, residual skin health, pain levels and patient limitation suggest that perforated liners are highly beneficial to patients. Layman's Abstract Individuals with amputation often find that they sweat more as they exert more energy when walking and because the total surface area of their body is reduced. Silicone liners are used to cushion the residual limb and as a way of attaching a prosthetic leg, but they act as insulators causing the residual limb to get hot and sweaty. The material isn’t breathable, so the sweat is not able to escape, instead staying on the skin’s surface and causing discomfort or leading to the development of skin conditions. Liners that have small holes in them allow sweat to travel away from the body and preserve skin health. Patients who wore a perforated liner, as well as patients who wore a liner without holes, filled in questionnaires about their experience, the results of which were compared. Generally, patients who wore the perforated liner had healthier skin on their residual limbs and experienced fewer skin conditions than the other patient group. Out of the issues they did experience, fewer were attributed to sweating. The study group experienced less frequent pain both in their physical and phantom limbs. They also considered themselves less limited by their prosthetic device and missed fewer days of work. These observations suggest that perforated liners are highly beneficial to patients within the prosthetic field. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/34610/26579 How To Cite: Davies K.C, McGrath M, Savage Z, Stenson A, Moser D, Zahedi S. Using perforated liners to combat the detrimental effects of excessive sweating in lower limb prosthesis users. Canadian Prosthetics & Orthotics Journal. 2020;Volume 3, Issue 2, No.1. https://doi.org/10.33137/cpoj.v3i2.34610 Corresponding Author: K.C Davies, Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK.E-mail: katherine.davies@blatchford.co.ukORCID: https://orcid.org/0000-0003-2933-4365
- 3 September 2020
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 3 (2)
Open AccessUSING PERFORATED LINERS TO COMBAT THE DETRIMENTAL EFFECTS OF EXCESSIVE SWEATING IN LOWER LIMB PROSTHESIS USERS
BACKGROUND: Excessive sweating of the residual limb has a substantial effect on the daily activities of people with lower limb amputation. Prosthetic liners offer protection and comfort to sensitive areas but often exacerbate perspiration. They act as insulators, trapping sweat on the skin’s surface to the detriment of skin health. Recently, liners with perforations have been developed, allowing the moisture to escape. The goal of this study was to assess the impact of such liners. METHODS: A sample group of 13 patients with unilateral transtibial amputation, who wore a perforated liner (PL) as part of their current prescription, was compared to 20 control patients who wore non-perforated liners (NPL). During their routine appointments, they completed a survey of scientifically validated outcome measures relating to their limb health, pain and the impact on daily life over a 12-month period. RESULTS: Patients using the PL had healthier residual limbs, reporting higher scores on questions relating to limb health, experiencing fewer skin issues (p<0.001) and estimating a 61.8% lower rating in perceived sweat (p=0.004). Perhaps consequentially, there was a lower incidence of residual (p=0.012) and phantom (p=0.001) limb pain when compared to the control group. The prevalence of individual issues affecting the residual limbs of PL users was also lower. Of the issues that remained, only 23% were attributed to sweating in PL users, compared to 49% for the NPL group (p=0.066). PL users missed fewer days of work in the year (2.4 vs 11.6, p=0.267) and were also limited on fewer days (1.4 vs 75.4, p=0.009). CONCLUSION: The use of perforated liners shows much promise within prosthetic care, significantly improving the health of the residual limb. The observed effects on perceived sweat reduction, residual skin health, pain levels and patient limitation suggest that perforated liners are highly beneficial to patients. Layman's Abstract Individuals with amputation often find that they sweat more as they exert more energy when walking and because the total surface area of their body is reduced. Silicone liners are used to cushion the residual limb and as a way of attaching a prosthetic leg, but they act as insulators causing the residual limb to get hot and sweaty. The material isn’t breathable, so the sweat is not able to escape, instead staying on the skin’s surface and causing discomfort or leading to the development of skin conditions. Liners that have small holes in them allow sweat to travel away from the body and preserve skin health. Patients who wore a perforated liner, as well as patients who wore a liner without holes, filled in questionnaires about their experience, the results of which were compared. Generally, patients who wore the perforated liner had healthier skin on their residual limbs and experienced fewer skin conditions than the other patient group. Out of the issues they did experience, fewer were attributed to sweating. The study group experienced less frequent pain both in their physical and phantom limbs. They also considered themselves less limited by their prosthetic device and missed fewer days of work. These observations suggest that perforated liners are highly beneficial to patients within the prosthetic field. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/34610/26579 How To Cite: Davies K.C, McGrath M, Savage Z, Stenson A, Moser D, Zahedi S. Using perforated liners to combat the detrimental effects of excessive sweating in lower limb prosthesis users. Canadian Prosthetics & Orthotics Journal. 2020;Volume 3, Issue 2, No.1. https://doi.org/10.33137/cpoj.v3i2.34610 Corresponding Author: K.C Davies, Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK.E-mail: katherine.davies@blatchford.co.ukORCID: https://orcid.org/0000-0003-2933-4365
- Open Access
- 15 December 2018
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
PERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE
INTRODUCTION For many years, the biomechanical evaluation of prosthetic performance has centred around gait analysis and motion capture. While this provides useful, scientific insights, everyday life is not limited to straight-line, level, steady-state walking. With advancements in portable sensor technology in the last two decades, long-term activity monitoring (AM) has become a more feasible and reliable prospect for accurately representing the real-world walking behaviour of patients. Modern microprocessor knees (MPKs) have begun to have this functionality built into the devices themselves, without the necessity for additional, external hardware. Abstract PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/32031/24448 How to cite: Sykes A, Stech N, Laszczak P, McGrath M, Kercher A, Zahedi S, Moser D. PERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE. CANADIAN PROSTHETICS & ORTHOTICS JOURNAL, VOLUME 1, ISSUE 2, 2018; ABSTRACT, ORAL PRESENTATION AT THE AOPA’S 101ST NATIONAL ASSEMBLY, SEPT. 26-29, VANCOUVER, CANADA, 2018. DOI: https://doi.org/10.33137/cpoj.v1i2.32031 Abstracts were Peer-reviewed by the American Orthotic Prosthetic Association (AOPA) 101st National Assembly Scientific Committee. http://www.aopanet.org/
- 15 December 2018
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Open AccessPERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE
INTRODUCTION For many years, the biomechanical evaluation of prosthetic performance has centred around gait analysis and motion capture. While this provides useful, scientific insights, everyday life is not limited to straight-line, level, steady-state walking. With advancements in portable sensor technology in the last two decades, long-term activity monitoring (AM) has become a more feasible and reliable prospect for accurately representing the real-world walking behaviour of patients. Modern microprocessor knees (MPKs) have begun to have this functionality built into the devices themselves, without the necessity for additional, external hardware. Abstract PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/32031/24448 How to cite: Sykes A, Stech N, Laszczak P, McGrath M, Kercher A, Zahedi S, Moser D. PERFORMANCE OF AN ACTIVITY MONITOR INTEGRATED INTO A MICROPROCESSOR KNEE. CANADIAN PROSTHETICS & ORTHOTICS JOURNAL, VOLUME 1, ISSUE 2, 2018; ABSTRACT, ORAL PRESENTATION AT THE AOPA’S 101ST NATIONAL ASSEMBLY, SEPT. 26-29, VANCOUVER, CANADA, 2018. DOI: https://doi.org/10.33137/cpoj.v1i2.32031 Abstracts were Peer-reviewed by the American Orthotic Prosthetic Association (AOPA) 101st National Assembly Scientific Committee. http://www.aopanet.org/
- 13 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 2263-2272 vol.5
The RAD750/sup TM/-a radiation hardened PowerPC/sup TM/ processor for high performance spaceborne applications
BAE SYSTEMS has developed the RAD750/sup TM/, a fully licensed radiation hardened implementation of the PowerPC 750/sup TM/ microprocessor, based on the original design database. The processor is implemented in a 2.5 volt, 0.25 micron, six-layer metal CMOS technology. Employing a superscalar RISC architecture, processor performance of 240 million Dhrystone 2.1 instructions per second (MIPS) at 133 MHz is provided, while dissipating less than six watts of power. The RAD750 achieves radiation hardness of 1E-11 upsets/bit-day and is designed for use in high performance spaceborne applications. A new companion ASIC, the Power PCI, provides the bridge between the RAD750, the 33 MHz PCI backplane bus, and system memory. The Power PCI is implemented in a 3.3 volt, 0.5 micron, five-layer metal CMOS technology, and achieves radiation hardness of <1E-10 upsets/bit-day. This paper describes the implementation of both designs.
- 13 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 2263-2272 vol.5
The RAD750/sup TM/-a radiation hardened PowerPC/sup TM/ processor for high performance spaceborne applications
BAE SYSTEMS has developed the RAD750/sup TM/, a fully licensed radiation hardened implementation of the PowerPC 750/sup TM/ microprocessor, based on the original design database. The processor is implemented in a 2.5 volt, 0.25 micron, six-layer metal CMOS technology. Employing a superscalar RISC architecture, processor performance of 240 million Dhrystone 2.1 instructions per second (MIPS) at 133 MHz is provided, while dissipating less than six watts of power. The RAD750 achieves radiation hardness of 1E-11 upsets/bit-day and is designed for use in high performance spaceborne applications. A new companion ASIC, the Power PCI, provides the bridge between the RAD750, the 33 MHz PCI backplane bus, and system memory. The Power PCI is implemented in a 3.3 volt, 0.5 micron, five-layer metal CMOS technology, and achieves radiation hardness of <1E-10 upsets/bit-day. This paper describes the implementation of both designs.