Svetlana M. Shmeleva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Svetlana M. Shmeleva has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Leonid Rafailovich Gavrilov
Russian Academy of Sciences
3 shared publications - Adam Shaw
National Physical Laboratory
2 shared publications - Eleanor Martin
Department of Medical Physics and Biomedical Engineering, University College London, London, UK
2 shared publications Neelaksh Sadhoo
Acoust. and Ionising Radiation Div., National Physical Lab., Teddington, United Kingdom
2 shared publications- Vera Aleksandrovna Khokhlova
Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
2 shared publications Oleg A Sapozhnikov
Physics Faculty, Moscow State University, Moscow 119991, Russia
1 shared publication
Latest Publications
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4154
Feasibility of using infra-red system for absolute calibration of high intensity focused ultrasound fields
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4154
Feasibility of using infra-red system for absolute calibration of high intensity focused ultrasound fields
- 1 August 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (2) , 1586-1597
Infrared mapping of ultrasound fields generated by medical transducers: Feasibility of determining absolute intensity levels
Considerable progress has been achieved in the use of infrared (IR) techniques for qualitative mapping of acoustic fields of high intensity focused ultrasound (HIFU) transducers. The authors have previously developed and demonstrated a method based on IR camera measurement of the temperature rise induced in an absorber less than 2 mm thick by ultrasonic bursts of less than 1 s duration. The goal of this paper was to make the method more quantitative and estimate the absolute intensity distributions by determining an overall calibration factor for the absorber and camera system. The implemented approach involved correlating the temperature rise measured in an absorber using an IR camera with the pressure distribution measured in water using a hydrophone. The measurements were conducted for two HIFU transducers and a flat physiotherapy transducer of 1 MHz frequency. Corresponding correction factors between the free field intensity and temperature were obtained and allowed the conversion of temperature images to intensity distributions. The system described here was able to map in good detail focused and unfocused ultrasound fields with sub-millimeter structure and with local time average intensity from below 0.1 W/cm2 to at least 50 W/cm2. Significantly higher intensities could be measured simply by reducing the duty cycle.
- 1 August 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (2) , 1586-1597
Infrared mapping of ultrasound fields generated by medical transducers: Feasibility of determining absolute intensity levels
Considerable progress has been achieved in the use of infrared (IR) techniques for qualitative mapping of acoustic fields of high intensity focused ultrasound (HIFU) transducers. The authors have previously developed and demonstrated a method based on IR camera measurement of the temperature rise induced in an absorber less than 2 mm thick by ultrasonic bursts of less than 1 s duration. The goal of this paper was to make the method more quantitative and estimate the absolute intensity distributions by determining an overall calibration factor for the absorber and camera system. The implemented approach involved correlating the temperature rise measured in an absorber using an IR camera with the pressure distribution measured in water using a hydrophone. The measurements were conducted for two HIFU transducers and a flat physiotherapy transducer of 1 MHz frequency. Corresponding correction factors between the free field intensity and temperature were obtained and allowed the conversion of temperature images to intensity distributions. The system described here was able to map in good detail focused and unfocused ultrasound fields with sub-millimeter structure and with local time average intensity from below 0.1 W/cm2 to at least 50 W/cm2. Significantly higher intensities could be measured simply by reducing the duty cycle.
- 26 March 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (8) , 2537-2559
The role of acoustic nonlinearity in tissue heating behind a rib cage using a high-intensity focused ultrasound phased array
The goal of this study was to investigate theoretically the effects of nonlinear propagation in a high-intensity focused ultrasound (HIFU) field produced by a therapeutic phased array and the resultant heating of tissue behind a rib cage. Three configurations of focusing were simulated: in water, in water with ribs in the beam path and in water with ribs backed by a layer of soft tissue. The Westervelt equation was used to model the nonlinear HIFU field, and a 1 MHz phased array consisting of 254 circular elements was used as a boundary condition to the model. The temperature rise in tissue was modelled using the bioheat equation, and thermally necrosed volumes were calculated using the thermal dose formulation. The shapes of lesions predicted by the modelling were compared with those previously obtained in in vitro experiments at low-power sonications. Intensity levels at the face of the array elements that corresponded to the formation of high-amplitude shock fronts in the focal region were determined as 10 W cm(-2) in the free field in water and 40 W cm(-2) in the presence of ribs. It was shown that exposures with shocks provided a substantial increase in tissue heating, and its better spatial localization in the main focal region only. The relative effects of overheating ribs and splitting of the focus due to the periodic structure of the ribs were therefore reduced. These results suggest that utilizing nonlinear propagation and shock formation effects can be beneficial for inducing confined HIFU lesions when irradiating through obstructions such as ribs. Design of compact therapeutic arrays to provide maximum power outputs with lower intensity levels at the elements is necessary to achieve shock wave regimes for clinically relevant sonication depths in tissue.
- 26 March 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (8) , 2537-2559
The role of acoustic nonlinearity in tissue heating behind a rib cage using a high-intensity focused ultrasound phased array
The goal of this study was to investigate theoretically the effects of nonlinear propagation in a high-intensity focused ultrasound (HIFU) field produced by a therapeutic phased array and the resultant heating of tissue behind a rib cage. Three configurations of focusing were simulated: in water, in water with ribs in the beam path and in water with ribs backed by a layer of soft tissue. The Westervelt equation was used to model the nonlinear HIFU field, and a 1 MHz phased array consisting of 254 circular elements was used as a boundary condition to the model. The temperature rise in tissue was modelled using the bioheat equation, and thermally necrosed volumes were calculated using the thermal dose formulation. The shapes of lesions predicted by the modelling were compared with those previously obtained in in vitro experiments at low-power sonications. Intensity levels at the face of the array elements that corresponded to the formation of high-amplitude shock fronts in the focal region were determined as 10 W cm(-2) in the free field in water and 40 W cm(-2) in the presence of ribs. It was shown that exposures with shocks provided a substantial increase in tissue heating, and its better spatial localization in the main focal region only. The relative effects of overheating ribs and splitting of the focus due to the periodic structure of the ribs were therefore reduced. These results suggest that utilizing nonlinear propagation and shock formation effects can be beneficial for inducing confined HIFU lesions when irradiating through obstructions such as ribs. Design of compact therapeutic arrays to provide maximum power outputs with lower intensity levels at the elements is necessary to achieve shock wave regimes for clinically relevant sonication depths in tissue.