Daniel Saenz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Saenz has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
Niko Papanikolaou
Department of Radiation Oncology The University of Texas Health Science Center at San Antonio San Antonio Texas USA
7 shared publications- Sotirios Stathakis
Department of Radiation Oncology, Mary Bird Perkin Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809, USA
7 shared publications Karl Rasmussen
Department of Radiation Oncology, School of Medicine The University of Texas Health Science Center at San Antonio San Antonio Texas USA
6 shared publicationsNeil Kirby
Department of Radiation Oncology School of Medicine The University of Texas Health Science Center at San Antonio San Antonio TX USA
5 shared publicationsNikos Papanikolaou
Department of Radiation Oncology, School of Medicine The University of Texas Health Science Center at San Antonio San Antonio Texas USA
4 shared publications- Bhudatt R. Paliwal
Department of Human Oncology, University of Wisconsin - Madison, Madison, USA
3 shared publications
Latest Publications
- Open Access
- 5 June 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70114
The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT
Purpose: Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing clinicians to better visualize motion of targets. To quantitatively understand the degree to which target visualization is improved by 4D CBCT, an edge visualization metric (EVM) has been developed to describe the change in voxel intensities at the edge of targets in 4D CBCT maximum intensity projection images relative to 3D CBCT images. Methods: The EVM describes the median distance where voxel intensities drop from 80% to 20% of target voxel values. The EVM was evaluated in a phantom study with a CIRS dynamic thorax phantom and with eleven on‐treatment lung SBRT patients. Results: In the phantom study, the EVM was improved for 4D CBCT relative to 3D CBCT for one‐cm targets (2.43 ± 0.22 mm vs. 2.67 ± 0.31 mm, p = 0.04) and for 2‐cm targets (2.60 ± 0.35 mm vs. 3.46 ± 1.03 mm, p = 0.02). In patients, the EVM was 3.59 ± 1.01 mm vs. 4.25 ± 1.24 mm ( p < 0.05). Conclusions: When evaluating an imaging acquisition's degree of motion blurring and ability to delineate target edges, EVM may provide a less biased way to evaluate edge detection in the presence of motion when compared to traditional methods.
- 5 June 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70114
Open AccessThe edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT
Purpose: Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing clinicians to better visualize motion of targets. To quantitatively understand the degree to which target visualization is improved by 4D CBCT, an edge visualization metric (EVM) has been developed to describe the change in voxel intensities at the edge of targets in 4D CBCT maximum intensity projection images relative to 3D CBCT images. Methods: The EVM describes the median distance where voxel intensities drop from 80% to 20% of target voxel values. The EVM was evaluated in a phantom study with a CIRS dynamic thorax phantom and with eleven on‐treatment lung SBRT patients. Results: In the phantom study, the EVM was improved for 4D CBCT relative to 3D CBCT for one‐cm targets (2.43 ± 0.22 mm vs. 2.67 ± 0.31 mm, p = 0.04) and for 2‐cm targets (2.60 ± 0.35 mm vs. 3.46 ± 1.03 mm, p = 0.02). In patients, the EVM was 3.59 ± 1.01 mm vs. 4.25 ± 1.24 mm ( p < 0.05). Conclusions: When evaluating an imaging acquisition's degree of motion blurring and ability to delineate target edges, EVM may provide a less biased way to evaluate edge detection in the presence of motion when compared to traditional methods.
- Open Access
- 19 October 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (2) , e14173
Dosimetric characterization of a new surface‐conforming electron MLC prototype
The purpose is to reduce normal tissue radiation toxicity for electron therapy through the creation of a surface‐conforming electron multileaf collimator (SCEM). The SCEM combines the benefits of skin collimation, electron conformal radiotherapy, and modulated electron radiotherapy.An early concept for the SCEM was constructed. It consists of leaves that protrude towards the patient, allowing the leaves to conform closely to irregular patient surfaces. The leaves are made of acrylic to decrease bremsstrahlung, thereby decreasing the out‐of‐field dose. Water tank scans were performed with the SCEM in place for various field sizes for all available electron energies (6, 9, 12, and 15 MeV) with a 0.5 cm air gap to the water surface at 100 cm source‐to‐surface distance (SSD). These measurements were compared with Cerrobend cutouts with the field size‐matched at 100 and 110 cm SSD. Output factor measurements were taken in solid water for each energy at dmax for both the cerrobend cutouts and SCEM at 100 cm SSD.Percent depth dose (PDD) curves for the SCEM shifted shallower for all energies and field sizes. The SCEM also produced a higher surface dose relative to Cerrobend cutouts, with the maximum being a 9.8% increase for the 3 cm × 9 cm field at 9 MeV. When compared to the Cerrobend cutouts at 110 cm SSD, the SCEM showed a significant decrease in the penumbra, particularly for lower energies (i.e., 6 and 9 MeV). The SCEM also showed reduced out‐of‐field dose and lower bremsstrahlung production than the Cerrobend cutouts. The SCEM provides significant improvement in the penumbra and out‐of‐field dose by allowing collimation close to the skin surface compared to Cerrobend cutouts. However, the added scatter from the SCEM increases shallow PDD values. Future work will focus on reducing this scatter while maintaining the penumbra and out‐of‐field benefits the SCEM has over conventional collimation.
- 19 October 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (2) , e14173
Open AccessDosimetric characterization of a new surface‐conforming electron MLC prototype
The purpose is to reduce normal tissue radiation toxicity for electron therapy through the creation of a surface‐conforming electron multileaf collimator (SCEM). The SCEM combines the benefits of skin collimation, electron conformal radiotherapy, and modulated electron radiotherapy.An early concept for the SCEM was constructed. It consists of leaves that protrude towards the patient, allowing the leaves to conform closely to irregular patient surfaces. The leaves are made of acrylic to decrease bremsstrahlung, thereby decreasing the out‐of‐field dose. Water tank scans were performed with the SCEM in place for various field sizes for all available electron energies (6, 9, 12, and 15 MeV) with a 0.5 cm air gap to the water surface at 100 cm source‐to‐surface distance (SSD). These measurements were compared with Cerrobend cutouts with the field size‐matched at 100 and 110 cm SSD. Output factor measurements were taken in solid water for each energy at dmax for both the cerrobend cutouts and SCEM at 100 cm SSD.Percent depth dose (PDD) curves for the SCEM shifted shallower for all energies and field sizes. The SCEM also produced a higher surface dose relative to Cerrobend cutouts, with the maximum being a 9.8% increase for the 3 cm × 9 cm field at 9 MeV. When compared to the Cerrobend cutouts at 110 cm SSD, the SCEM showed a significant decrease in the penumbra, particularly for lower energies (i.e., 6 and 9 MeV). The SCEM also showed reduced out‐of‐field dose and lower bremsstrahlung production than the Cerrobend cutouts. The SCEM provides significant improvement in the penumbra and out‐of‐field dose by allowing collimation close to the skin surface compared to Cerrobend cutouts. However, the added scatter from the SCEM increases shallow PDD values. Future work will focus on reducing this scatter while maintaining the penumbra and out‐of‐field benefits the SCEM has over conventional collimation.
- Open Access
- 25 August 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (10) , 36-44
A customizable aluminum compensator system for total body irradiation
Purpose To develop a simplified aluminum compensator system for total body irradiation (TBI) that is easy to assemble and modify in a short period of time for customized patient treatments. Methods The compensator is composed of a combination of 0.3 cm thick aluminum bars, two aluminum T-tracks, spacers, and metal bolts. The system is mounted onto a plexiglass block tray. The design consists of 11 fixed sectors spanning from the patient's head to feet. The outermost sectors utilize 7.6 cm wide aluminum bars, while the remaining sectors use 2.5 cm wide aluminum bars. There is a magnification factor of 5 from the compensator to the patient treatment plane. Each bar of aluminum is interconnected at each adjacent sector with a tongue and groove arrangement and fastened to the T-track using a metal washer, bolt, and nut. Inter-bar leakage of the compensator was tested using a water tank and diode. End-to-end measurements were performed with an ion chamber in a solid water phantom and also with a RANDO phantom using internal and external optically stimulated luminescent detectors (OSLDs). In-vivo patient measurements from the first 20 patients treated with this aluminum compensator were compared to those from 20 patients treated with our previously used lead compensator system. Results The compensator assembly time was reduced to 20–30 min compared to the 2–4 h it would take with the previous lead design. All end-to-end measurements were within 10% of that expected. The median absolute in-vivo error for the aluminum compensator was 3.7%, with 93.8% of measurements being within 10% of that expected. The median error for the lead compensator system was 5.3%, with 85.1% being within 10% of that expected. Conclusion This design has become the standard compensator at our clinic. It allows for quick assembly and customization along with meeting the Task Group 29 recommendations for dose uniformity.
- 25 August 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (10) , 36-44
Open AccessA customizable aluminum compensator system for total body irradiation
Purpose To develop a simplified aluminum compensator system for total body irradiation (TBI) that is easy to assemble and modify in a short period of time for customized patient treatments. Methods The compensator is composed of a combination of 0.3 cm thick aluminum bars, two aluminum T-tracks, spacers, and metal bolts. The system is mounted onto a plexiglass block tray. The design consists of 11 fixed sectors spanning from the patient's head to feet. The outermost sectors utilize 7.6 cm wide aluminum bars, while the remaining sectors use 2.5 cm wide aluminum bars. There is a magnification factor of 5 from the compensator to the patient treatment plane. Each bar of aluminum is interconnected at each adjacent sector with a tongue and groove arrangement and fastened to the T-track using a metal washer, bolt, and nut. Inter-bar leakage of the compensator was tested using a water tank and diode. End-to-end measurements were performed with an ion chamber in a solid water phantom and also with a RANDO phantom using internal and external optically stimulated luminescent detectors (OSLDs). In-vivo patient measurements from the first 20 patients treated with this aluminum compensator were compared to those from 20 patients treated with our previously used lead compensator system. Results The compensator assembly time was reduced to 20–30 min compared to the 2–4 h it would take with the previous lead design. All end-to-end measurements were within 10% of that expected. The median absolute in-vivo error for the aluminum compensator was 3.7%, with 93.8% of measurements being within 10% of that expected. The median error for the lead compensator system was 5.3%, with 85.1% being within 10% of that expected. Conclusion This design has become the standard compensator at our clinic. It allows for quick assembly and customization along with meeting the Task Group 29 recommendations for dose uniformity.
- Open Access
- 3 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 198-207
On the evaluation of mobile target trajectory between four‐dimensional computer tomography and four‐dimensional cone‐beam computer tomography
Purpose: For mobile lung tumors, four‐dimensional computer tomography (4D CT) is often used for simulation and treatment planning. Localization accuracy remains a challenge in lung stereotactic body radiation therapy (SBRT) treatments. An attractive image guidance method to increase localization accuracy is 4D cone‐beam CT (CBCT) as it allows for visualization of tumor motion with reduced motion artifacts. However, acquisition and reconstruction of 4D CBCT differ from that of 4D CT. This study evaluates the discrepancies between the reconstructed motion of 4D CBCT and 4D CT imaging over a wide range of sine target motion parameters and patient waveforms.Methods: A thorax motion phantom was used to examine 24 sine motions with varying amplitudes and cycle times and seven patient waveforms. Each programmed motion was imaged using 4D CT and 4D CBCT. The images were processed to auto segment the target. For sine motion, the target centroid at each phase was fitted to a sinusoidal curve to evaluate equivalence in amplitude between the two imaging modalities. The patient waveform motion was evaluated based on the average 4D data sets.Results: The mean difference and root‐mean‐square‐error between the two modalities for sine motion were −0.35 ± 0.22 and 0.60 mm, respectively, with 4D CBCT slightly overestimating amplitude compared with 4D CT. The two imaging methods were determined to be significantly equivalent within ±1 mm based on two one‐sided t tests (p < 0.001). For patient‐specific motion, the mean difference was 1.5 ± 2.1 (0.8 ± 0.6 without outlier), 0.4 ± 0.3, and 0.8 ± 0.6 mm for superior/inferior (SI), anterior/posterior (AP), and left/right (LR), respectively.Conclusion: In cases where 4D CT is used to image mobile tumors, 4D CBCT is an attractive localization method due to its assessment of motion with respect to 4D CT, particularly for lung SBRT treatments where accuracy is paramount.
- 3 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 198-207
Open AccessOn the evaluation of mobile target trajectory between four‐dimensional computer tomography and four‐dimensional cone‐beam computer tomography
Purpose: For mobile lung tumors, four‐dimensional computer tomography (4D CT) is often used for simulation and treatment planning. Localization accuracy remains a challenge in lung stereotactic body radiation therapy (SBRT) treatments. An attractive image guidance method to increase localization accuracy is 4D cone‐beam CT (CBCT) as it allows for visualization of tumor motion with reduced motion artifacts. However, acquisition and reconstruction of 4D CBCT differ from that of 4D CT. This study evaluates the discrepancies between the reconstructed motion of 4D CBCT and 4D CT imaging over a wide range of sine target motion parameters and patient waveforms.Methods: A thorax motion phantom was used to examine 24 sine motions with varying amplitudes and cycle times and seven patient waveforms. Each programmed motion was imaged using 4D CT and 4D CBCT. The images were processed to auto segment the target. For sine motion, the target centroid at each phase was fitted to a sinusoidal curve to evaluate equivalence in amplitude between the two imaging modalities. The patient waveform motion was evaluated based on the average 4D data sets.Results: The mean difference and root‐mean‐square‐error between the two modalities for sine motion were −0.35 ± 0.22 and 0.60 mm, respectively, with 4D CBCT slightly overestimating amplitude compared with 4D CT. The two imaging methods were determined to be significantly equivalent within ±1 mm based on two one‐sided t tests (p < 0.001). For patient‐specific motion, the mean difference was 1.5 ± 2.1 (0.8 ± 0.6 without outlier), 0.4 ± 0.3, and 0.8 ± 0.6 mm for superior/inferior (SI), anterior/posterior (AP), and left/right (LR), respectively.Conclusion: In cases where 4D CT is used to image mobile tumors, 4D CBCT is an attractive localization method due to its assessment of motion with respect to 4D CT, particularly for lung SBRT treatments where accuracy is paramount.
- 1 January 2021
- Vol. 7 (3) , 223-232
Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions.
The accuracy of stereotactic radiosurgery (SRS) to multiple metastases with a single-isocenter using high definition dynamic radiosurgery (HDRS) was evaluated across institutions. An SRS plan was delivered at six HDRS-capable institutions to an anthropomorphic phantom consisting of point, film, and 3D-gel dosimeters. Direct dose comparison and gamma analysis were used to evaluate the accuracy. Point measurements averaged across institutions were within 1.2±0.5%. The average gamma passing rate in the film was 96.6±2.2% (3%/2 mm). For targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions across multiple institutions in this study was within 1 mm for targets within 4 cm of isocenter. Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.
- 1 January 2021
- Vol. 7 (3) , 223-232
Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions.
The accuracy of stereotactic radiosurgery (SRS) to multiple metastases with a single-isocenter using high definition dynamic radiosurgery (HDRS) was evaluated across institutions. An SRS plan was delivered at six HDRS-capable institutions to an anthropomorphic phantom consisting of point, film, and 3D-gel dosimeters. Direct dose comparison and gamma analysis were used to evaluate the accuracy. Point measurements averaged across institutions were within 1.2±0.5%. The average gamma passing rate in the film was 96.6±2.2% (3%/2 mm). For targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions across multiple institutions in this study was within 1 mm for targets within 4 cm of isocenter. Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.
- Open Access
- 18 July 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (9) , 107-115
Patient‐specific dose quality assurance of single‐isocenter multiple brain metastasis stereotactic radiosurgery using PTW Octavius 4D
Purpose: Single‐isocenter multiple brain metastasis stereotactic radiosurgery is an efficient treatment modality increasing in clinical practice. The need to provide accurate, patient‐specific quality assurance (QA) for these plans is met by several options. This study reviews some of these options and explores the use of the Octavius 4D as a solution for patient‐specific plan quality assurance.Methods: The Octavius 4D Modular Phantom (O4D) with the 1000 SRS array was evaluated in this study. The array consists of 977 liquid‐filled ion chambers. The center 5.5 cm × 5.5 cm area has a detector spacing of 2.5 mm. The ability of the O4D to reconstruct three‐dimensional (3D) dose was validated against a 3D gel dosimeter, ion chamber, and film measurements. After validation, 15 patients with 2–11 targets had their plans delivered to the phantom. The criteria used for the gamma calculation was 3%/1 mm. The portion of targets which were measurable by the phantom was countable. The accompanying software compiled the measured doses allowing each target to be counted from the measured dose distribution.Results: Spatial resolution was sufficient to verify the high dose distributions characteristic of SRS. Amongst the 15 patients there were 74 targets. Of the 74 targets, 61 (82%) of them were visible on the measured dose distribution. The average gamma passing rate was 99.3% (with sample standard deviation of 0.68%).Conclusions: The high resolution provided by the O4D with 1000 SRS board insert allows for very high‐resolution measurement. This high resolution in turn can allow for high gamma passing rates. The O4D with the 1000 SRS array is an acceptable method of performing quality assurance for single‐isocenter multiple brain metastasis SRS.
- 18 July 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (9) , 107-115
Open AccessPatient‐specific dose quality assurance of single‐isocenter multiple brain metastasis stereotactic radiosurgery using PTW Octavius 4D
Purpose: Single‐isocenter multiple brain metastasis stereotactic radiosurgery is an efficient treatment modality increasing in clinical practice. The need to provide accurate, patient‐specific quality assurance (QA) for these plans is met by several options. This study reviews some of these options and explores the use of the Octavius 4D as a solution for patient‐specific plan quality assurance.Methods: The Octavius 4D Modular Phantom (O4D) with the 1000 SRS array was evaluated in this study. The array consists of 977 liquid‐filled ion chambers. The center 5.5 cm × 5.5 cm area has a detector spacing of 2.5 mm. The ability of the O4D to reconstruct three‐dimensional (3D) dose was validated against a 3D gel dosimeter, ion chamber, and film measurements. After validation, 15 patients with 2–11 targets had their plans delivered to the phantom. The criteria used for the gamma calculation was 3%/1 mm. The portion of targets which were measurable by the phantom was countable. The accompanying software compiled the measured doses allowing each target to be counted from the measured dose distribution.Results: Spatial resolution was sufficient to verify the high dose distributions characteristic of SRS. Amongst the 15 patients there were 74 targets. Of the 74 targets, 61 (82%) of them were visible on the measured dose distribution. The average gamma passing rate was 99.3% (with sample standard deviation of 0.68%).Conclusions: The high resolution provided by the O4D with 1000 SRS board insert allows for very high‐resolution measurement. This high resolution in turn can allow for high gamma passing rates. The O4D with the 1000 SRS array is an acceptable method of performing quality assurance for single‐isocenter multiple brain metastasis SRS.
- Open Access
- 15 July 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 165, 109316
DNA dosimeter measurements of beam profile using a novel simultaneous processing technique
- 15 July 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 165, 109316
Open AccessDNA dosimeter measurements of beam profile using a novel simultaneous processing technique
- Open Access
- 4 March 2020
- Published by Springer Nature in Research Square
Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions
Background The accuracy of stereotactic radiosurgery to multiple brain metastases with a single isocenter using high definition dynamic radiosurgery (HDRS) was evaluated to assess robustness, repeatability, and possibility of inter-institutional quality assurance amongst multiple institutions. Methods A CT simulation scan obtained from a previously treated patient was used as the data set for targeting seven brain lesions. A VMAT treatment plan was generated using Monaco and was replicated at six HDRS-capable institutions using a plan template. All institutions subsequently irradiated 3D-printed head anthropomorphic phantoms mimicking the patient’s anatomy. Three different phantoms with a point dosimeter insert, film insert, and a gel dosimeter were used. Absolute dosimetry end-to-end dosimetric accuracy as well as gamma analysis for relative dose distribution agreement analysis was used to evaluate measurement agreement with calculation. Results Point measurements averaged across all institutions using six-degree-of-freedom treatment positioning correction were within 1.2±0.5%. The average gamma passing rate in the film plane using 3D global 3D gamma analysis was 96.6±2.2% (3%/2 mm). For all targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). 88.0% average gamma passing rate was found for targets beyond 4 cm. The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions was established across multiple institutions in this study to be within 1 mm for targets within 4 cm of isocenter. Conclusions Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.
- 4 March 2020
- Published by Springer Nature in Research Square
Open AccessRobustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions
Background The accuracy of stereotactic radiosurgery to multiple brain metastases with a single isocenter using high definition dynamic radiosurgery (HDRS) was evaluated to assess robustness, repeatability, and possibility of inter-institutional quality assurance amongst multiple institutions. Methods A CT simulation scan obtained from a previously treated patient was used as the data set for targeting seven brain lesions. A VMAT treatment plan was generated using Monaco and was replicated at six HDRS-capable institutions using a plan template. All institutions subsequently irradiated 3D-printed head anthropomorphic phantoms mimicking the patient’s anatomy. Three different phantoms with a point dosimeter insert, film insert, and a gel dosimeter were used. Absolute dosimetry end-to-end dosimetric accuracy as well as gamma analysis for relative dose distribution agreement analysis was used to evaluate measurement agreement with calculation. Results Point measurements averaged across all institutions using six-degree-of-freedom treatment positioning correction were within 1.2±0.5%. The average gamma passing rate in the film plane using 3D global 3D gamma analysis was 96.6±2.2% (3%/2 mm). For all targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). 88.0% average gamma passing rate was found for targets beyond 4 cm. The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions was established across multiple institutions in this study to be within 1 mm for targets within 4 cm of isocenter. Conclusions Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.
- 1 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (10) , 105009
Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications
In single-isocenter stereotactic radiosurgery/radiotherapy (SRS/SRT) intracranial applications, multiple targets are being treated concurrently, often involving non-coplanar arcs, small photon beams and steep dose gradients. In search for more rigorous quality assurance protocols, this work presents and evaluates a novel methodology for patient-specific pre-treatment plan verification, utilizing 3D printing technology. In a patient’s planning CT scan, the external contour and bone structures were segmented and 3D-printed using high-density bone-mimicking material. The resulting head phantom was filled with water while a film dosimetry insert was incorporated. Patient and phantom CT image series were fused and inspected for anatomical coherence. HUs and corresponding densities were compared in several anatomical regions within the head. Furthermore, the level of patient-to-phantom dosimetric equivalence was evaluated both computationally and experimentally. A single-isocenter multi-focal SRS treatment plan was prepared, while dose distributions were calculated on both CT image series, using identical calculation parameters. Phantom- and patient-derived dose distributions were compared in terms of isolines, DVHs, dose-volume metrics and 3D gamma index (GI) analysis. The phantom was treated as if the real patient and film measurements were compared against the patient-derived calculated dose distribution. Visual inspection of the fused CT images suggests excellent geometric similarity between phantom and patient, also confirmed using similarity indices. HUs and densities agreed within one standard deviation except for the skin (modeled as ‘bone’) and sinuses (water-filled). GI comparison between the calculated distributions resulted in passing rates better than 97% (1%/1 mm). DVHs and dose-volume metrics were also in satisfying agreement. In addition to serving as a feasibility proof-of-concept, experimental absolute film dosimetry verified the computational study results. GI passing rates were above 90%. Results of this work suggest that employing the presented methodology, patient-equivalent phantoms (except for the skin and sinuses areas) can be produced, enabling literally patient-specific pre-treatment plan verification in intracranial applications.
- 1 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (10) , 105009
Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications
In single-isocenter stereotactic radiosurgery/radiotherapy (SRS/SRT) intracranial applications, multiple targets are being treated concurrently, often involving non-coplanar arcs, small photon beams and steep dose gradients. In search for more rigorous quality assurance protocols, this work presents and evaluates a novel methodology for patient-specific pre-treatment plan verification, utilizing 3D printing technology. In a patient’s planning CT scan, the external contour and bone structures were segmented and 3D-printed using high-density bone-mimicking material. The resulting head phantom was filled with water while a film dosimetry insert was incorporated. Patient and phantom CT image series were fused and inspected for anatomical coherence. HUs and corresponding densities were compared in several anatomical regions within the head. Furthermore, the level of patient-to-phantom dosimetric equivalence was evaluated both computationally and experimentally. A single-isocenter multi-focal SRS treatment plan was prepared, while dose distributions were calculated on both CT image series, using identical calculation parameters. Phantom- and patient-derived dose distributions were compared in terms of isolines, DVHs, dose-volume metrics and 3D gamma index (GI) analysis. The phantom was treated as if the real patient and film measurements were compared against the patient-derived calculated dose distribution. Visual inspection of the fused CT images suggests excellent geometric similarity between phantom and patient, also confirmed using similarity indices. HUs and densities agreed within one standard deviation except for the skin (modeled as ‘bone’) and sinuses (water-filled). GI comparison between the calculated distributions resulted in passing rates better than 97% (1%/1 mm). DVHs and dose-volume metrics were also in satisfying agreement. In addition to serving as a feasibility proof-of-concept, experimental absolute film dosimetry verified the computational study results. GI passing rates were above 90%. Results of this work suggest that employing the presented methodology, patient-equivalent phantoms (except for the skin and sinuses areas) can be produced, enabling literally patient-specific pre-treatment plan verification in intracranial applications.
- Open Access
- 20 November 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (1) , 154-159
A dosimetric analysis of a spine SBRT specific treatment planning system
Purpose: The Brainlab Elements treatment planning system utilizes distinct modules for treatment planning specific to stereotactic treatment sites including single or multiple brain lesions as well as spine. This work investigates the hypothesis that an optimization tailored specifically to spine can in fact create dosimetrically superior plans to those created in more general use treatment planning systems (TPS).Methods: Ten spine patients at our institution were replanned in Brainlab Elements, Phillips Pinnacle3, and Elekta Monaco. The planning target volume (PTV) included the vertebral body (in either the thoracic or lumbar spine), pedicles, and transverse processes. In all plans, the target was prescribed 20 Gy to 95% of the PTV. Objectives for the study included D5%<25 Gy and spinal cord D0.035cc < 14 Gy. Plans were evaluated by the satisfaction of the objectives as well total monitor units (MU), gradient index (GI), conformity index (CI), and dose gradient (distance between 100% and 50% isodose lines) in a selected slice between the vertebral body and spinal cord.Results: All TPS produced clinically acceptable plans. The sharpest dose gradient was achieved with Elements (mean 3.3 ± 0.2 mm). This resulted in lowest spinal cord maximum point doses (6.6 ± 1.0 Gy). Gradient indices were also the smallest for Elements (3.6 ± 0.5). Further improvement in gradient index and spinal cord sparing were not performed due to the subsequent violation of the PTV D5% < 25 Gy constraint or the loss of conformity due to the loss of coverage at the PTV‐spinal canal interface.Conclusions: Brainlab Elements planning which relies on arc duplication to specifically optimize for spine anatomy did result in dosimetrically superior plans while holding prescription levels constant. While any planning system can improve upon specific dosimetric objectives, the simultaneous satisfaction of all constraints was best achieved with Brainlab Elements.
- 20 November 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (1) , 154-159
Open AccessA dosimetric analysis of a spine SBRT specific treatment planning system
Purpose: The Brainlab Elements treatment planning system utilizes distinct modules for treatment planning specific to stereotactic treatment sites including single or multiple brain lesions as well as spine. This work investigates the hypothesis that an optimization tailored specifically to spine can in fact create dosimetrically superior plans to those created in more general use treatment planning systems (TPS).Methods: Ten spine patients at our institution were replanned in Brainlab Elements, Phillips Pinnacle3, and Elekta Monaco. The planning target volume (PTV) included the vertebral body (in either the thoracic or lumbar spine), pedicles, and transverse processes. In all plans, the target was prescribed 20 Gy to 95% of the PTV. Objectives for the study included D5%<25 Gy and spinal cord D0.035cc < 14 Gy. Plans were evaluated by the satisfaction of the objectives as well total monitor units (MU), gradient index (GI), conformity index (CI), and dose gradient (distance between 100% and 50% isodose lines) in a selected slice between the vertebral body and spinal cord.Results: All TPS produced clinically acceptable plans. The sharpest dose gradient was achieved with Elements (mean 3.3 ± 0.2 mm). This resulted in lowest spinal cord maximum point doses (6.6 ± 1.0 Gy). Gradient indices were also the smallest for Elements (3.6 ± 0.5). Further improvement in gradient index and spinal cord sparing were not performed due to the subsequent violation of the PTV D5% < 25 Gy constraint or the loss of conformity due to the loss of coverage at the PTV‐spinal canal interface.Conclusions: Brainlab Elements planning which relies on arc duplication to specifically optimize for spine anatomy did result in dosimetrically superior plans while holding prescription levels constant. While any planning system can improve upon specific dosimetric objectives, the simultaneous satisfaction of all constraints was best achieved with Brainlab Elements.