Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Magdalena Niemczewska-Wójcik has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dual measurement system for surface texture characterization of a zirconium-modified aluminum alloy

    by Magdalena Niemczewska-Wójcik, Monika Madej, Dana Bolibruchová

  • Open Access

    Mechanical Performance Investigation of Recycled HDPE Reinforced with Nanoclay for Enhanced Strength and Sustainability

    by Sundarakannan Rajendran, Sakthivel Sankaran, Geetha Palani, Magdalena Niemczewska-Wójcik, Thirumalai Kumaran Sundaresan, Uthayakumar Marimuthu, Koppiahraj Karuppiah

    The increasing demand for sustainable materials has intensified efforts to enhance the performance of recycled polymers for engineering applications. This study investigates the effect of nanoclay reinforcement on the mechanical properties of recycled high-density polyethylene (rHDPE). Nanoclay was incorporated into rHDPE at varying loadings through melt blending, and the resulting composites were evaluated in terms of tensile, flexural, impact, and hardness properties. The tensile strength and tensile modulus improved significantly with increasing nanoclay content, reaching maximum values of 31.27 MPa and 2.39 GPa, respectively, at 1.5 wt% nanoclay, corresponding to increases of 23.11% and 47.53% relative to unreinforced rHDPE. Similarly, the flexural strength and flexural modulus attained peak values of 25.88 MPa and 1105.08 MPa at 1.5 wt% nanoclay, representing improvements of 12.57% and 15.49%, respectively. Impact strength exhibited a different trend, achieving a maximum value of 73.58 kJ/m2 at 0.5 wt% nanoclay before decreasing at higher loadings, indicating a transition towards more brittle behaviour. Hardness increased progressively with nanoclay addition and reached a maximum value of 68.06 Shore D at 1.5 wt%, exceeding both unreinforced rHDPE and virgin HDPE. The overall results demonstrate that nanoclay effectively compensates for the mechanical degradation associated with recycling by enhancing stiffness, strength, and surface hardness. Among the investigated formulations, 1.5 wt% nanoclay provided the optimum balance of mechanical performance, while higher loadings led to reduced reinforcement efficiency due to particle agglomeration. These findings highlight the potential of nanoclay-reinforced rHDPE as a sustainable, high-performance material for applications in packaging, construction, and automotive components, thereby supporting circular economy initiatives and resource-efficient material development.


  • Open Access

    Surface texture and wear characteristics of micro-hybrid and nano-hybrid resin composites under simulated frictional conditions

    by Magdalena A. Osiewicz, Cornelis J. Kleverlaan, Arie Werner, Michael Marxer, Dominique Filipec, Magdalena Niemczewska-Wójcik

    The goal of work was to evaluate the surface texture and wear behaviour of two resin-based composites – AP-X (micro-hybrid) and FSE (nano-hybrid), under two frictional conditions. Specimens were subjected to simulated occlusal wear using the ACTA wear machine, following two-body wear (full contact) and three-body wear (slurry-lubricated) protocols. Surface texture was assessed before and after wear using 3D profilometry and SEM. Roughness parameters and wear rate were measured. SEM micrographs provided insights into wear mechanisms. Initial surface roughness of FSE was higher than AP-X due to nanocluster morphology (Ra: 0.965–1.050 μm vs. 0.470–0.489 μm; Sq: 1.25–1.32 μm vs. 0.554–0.667 μm ). Two-body wear caused significant degradation in FSE, including nanocluster plucking and matrix cracking, whereas AP-X showed more stable wear resistance. Under three-body wear, FSE demonstrated a polishing effect (Ra reduced to 0.564 μm; Sq reduced to 0.766 μm), while AP-X experienced increased surface roughness (Ra increased to 0.966 μm; Sq increased to 0.869 μm) due to macro-filler exposure. Wear analysis confirmed higher material loss under three-body friction conditions. FSE exhibited better performance under slurry-lubricated conditions but was more susceptible to fatigue-driven degradation in full contact. Conversely, AP-X demonstrated superior stability under two-body wear, making it more suitable for bruxers.


  • ASSESSMENT OF THE POTENTIAL FUNCTIONAL PROPERTIES OF NITRIDE COATING SURFACES FOR MEDICAL APPLICATIONS

    by Magdalena Niemczewska-Wójcik, Danuta Owczarek, Monika Madej, Piotr Niesłony, Michał Jakubowicz

    The study focuses on selected nitride coatings (TiN, ZrN, CrN) applied to AISI 316L surgical steel, used in medical technology for dental and surgical friction components. Cylindrical specimens with different surface characteristics, polished and sandblasted finishes, underwent surface topography analysis using contact measurement methods. Uncoated AISI 316L served as the base surface. The objective was to assess the potential performance of these nitride coatings and compare their surface properties with those of the uncoated base material. Results showed that TiN and CrN coatings on both polished and sandblasted surfaces exhibited the most promising topographic and profile characteristics. These findings will be confirmed through further tribological laboratory tests.

  • Open Access

    Synthesis of silicone oil based magnetorhelogical fluid and performance analysis in a landing gear using bat-based gradient boost mechanism

    by Selvaraj Suseela Stalin, Marimuthu Uthayakumar, P. Balamurugan, M. Pethuraj, Jerzy A. Sładek, Magdalena Niemczewska-Wójcik

    Aircraft landing gear is used to reduce the vibration and impact load that is transmitted from the ground to the aircraft body. This paper aims at investigating the application of the Magneto-Rehological damper in the landing gear system which provides high amplitude damping force through the...


  • Open Access

    Surface Topography and Tribological Properties of Cutting Tool Coatings

    by Magdalena Niemczewska-Wójcik, Monika Madej

    The surface topography formed during the technological process has an influence on the wear characteristics and modifies the surface topography of friction components during the operation process, including cutting tools. It is therefore important to carry out research to find the best material...


  • Open Access

    Dry Sliding Wear Studies on Sillimanite and B4C Reinforced Aluminium Hybrid Composites Fabricated by Vacuum Assisted Stir Casting Process

    by Manickaraj Pethuraj, Marimuthu Uthayakumar, Shanmugavel Rajesh, Mohd Shukry Abdul Majid, Sivaprakasam Rajakarunakaran, Magdalena Niemczewska-Wójcik

    This paper presents the results of studies to understand the influence of hybridisation on mechanical and tribological behaviour as well as dry sliding wear of aluminium metal matrix composites. Sillimanite and boron carbide (B4C) were used as primary and secondary reinforcements and pure aluminium was used as the matrix material. The composite was fabricated by using a vacuum assisted stir casting process. Different research instruments were used, including a scanning electron microscope with EDX spectrometer, a surface measurement device, a thermal image analyser, as well as a tribotester. The results show that tensile, impact strength and hardness of the hybridised composites are superior (a step ahead) than unreinforced and primary composites. The wear behaviour of the fabricated specimens was tested for the dry sliding wear behaviour under the load range of 10–50 N with the steps of 20 N for the sliding velocities 0.75, 1.5 and 2.25 m/s over a distance of 1000 m. The wear rate increased with load and decreased as the wt.% of reinforcement increased. The wear rate of the composite with 10 wt.% Al2SiO5 was approximately 44% lower than that of the composite with 5 wt.% Al2SiO5. The same dependence was noted for hybrid composite (5 wt.% Al2SiO5 + 5 wt.% B4C)—the wear rate was approximately 50.8% lower than that of the composite with 5 wt.% Al2SiO5 under the same test condition. The friction coefficient decreased as the weight percentage of the reinforcement (Al2SiO5 and B4C) increased due to the uniform distribution of the reinforcement on the surface of the composites. The main wear mechanism of the studied materials was abrasion wear. The wear mechanism of the composite had tribochemical type. It involved the oxidation and transfer of the material, which formed protective tribolayers ensuring an additional sliding process. The mechanism that played the main role in the wear process of the composites was a combination of abrasive, adhesive and oxidative wear.


  • Open Access

    Investigation of the Surface Topography of Titanium Alloys Applied to Friction Components

    by Grzegorz Gawłowski, Magdalena Niemczewska-Wójcik

    The subject of this study and analysis was titanium alloy, applied among others to the friction components of orthopaedic (artificial hip joint) implants. This material was subjected to abrasive finishing using a synthetic diamond as a tool. The properties of the studied titanium alloy were...


  • Open Access

    Characteristics of the Surface Topography and Tribological Properties of Reinforced Aluminum Matrix Composite

    by Magdalena Niemczewska-Wójcik, Manickaraj Pethuraj, Marimuthu Uthayakumar, Mohd Shukry Abdul Majid

    Due to their excellent synergistic properties, Aluminum Matrix Composites (AMC) have achieved a high degree of prominence in different industries. In addition to strength, the wear resistance of materials is also an important criterion for numerous applications. The wear resistance depends on the surface topography as well as the working conditions of the interacting parts. Therefore, extensive experiments are being conducted to improve the suitability of engineering materials (including AMC) for different applications. This paper presents research on manufactured aluminum metal matrix composites reinforced with 10 wt.% of Al2SiO5 (aluminum sillimanite). The manufactured and prepared samples were subjected to surface topography measurements and to tribological studies both with and without lubricant using a block-on-ring tester. Based on the results, analyses of the surface topography (i.e., surface roughness parameters, Abbott–Firestone curve, and surface defects) as well as of the tribological characteristics (i.a. friction coefficient, linear wear, and wear intensity) were performed. Differences in the surface topography of the manufactured elements were shown. The surface topography had a significant impact on tribological characteristics of the sliding joints in the tests where lubrication was and was not used. Better tribological characteristics were obtained for the surfaces characterized by greater roughness (determined on the basis of both the profile and surface texture parameters). In the case of tribological tests with lubrication, the friction coefficient as well as the wear intensity was significantly lower compared to tribological tests without lubrication. However, lower values of the friction coefficient and wear intensity were still recorded for the surfaces that were characterized by greater roughness. The obtained results showed that it is important to analyze the surface topography because surface characteristics influence tribological properties.


  • Open Access

    Stereometric and Tribometric Studies of Polymeric Pin and Ceramic Plate Friction Pair Components

    by Magdalena Niemczewska-Wójcik, Artur Wójcik

    Two complementary approaches should be used for the full characterisation of friction pair components. The first approach consists of stereometric studies of machined as well as worn surface topography of the friction components with multiple measurement methods used. The second approach, tribometric studies, enables the tribological characteristics of the friction pair. This work presents the complete characterisation of polymeric pin and ceramic plate friction pair components based on studies with the use of three research instruments: an interference microscope, a scanning electron microscope and a tribological tester. The results of the studies showed that the same treatment conditions used for different but similar ceramic materials did not provide exactly the same characteristics of both the machined and worn surface topography. Moreover, the results showed that the material properties and machined surface topography of the ceramic component significantly affected the friction coefficient and linear wear as well as the wear intensity of the polymeric component. Connecting the two approaches, stereometric studies and tribometric studies, allowed for a better identification of the wear mechanism of the polymeric pin (i.e., abrasion, fatigue and adhesion wear) and the kind of wear products (polymeric material).