Pamela Abshire
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pamela Abshire has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Elisabeth Smela
Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
4 shared publications - Bathiya Prashan Senevirathna
Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA; Institute for Systems Research, University of Maryland, College Park, MD, USA
3 shared publications - Kasun Pathirage
Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, United States
3 shared publications - Marc Dandin
Department of Electrical and Computer Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
3 shared publications - Peng Xu
Command and Control Engineering College, Army Engineering University of PLA, Nanjing 210007, China
3 shared publications - Sheung Lu
Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA; Institute for Systems Research, University of Maryland, College Park, MD, USA
3 shared publications
Latest Publications
- Open Access
A fast and simple algorithm for accurate spike detection in HD-MEA recordings
Background: High density microelectrode arrays provide a strong platform to study individual neuronal activity and neuronal network dynamics. However, the analysis of high volume and complex data present several challenges. Common spike detection methods based on Root-Mean-Square (RMS) threshold crossing underestimate the number of spikes during neuronal bursting, which frequently occurs in neuronal cultures. In addition, the detection of action potentials by multiple electrodes makes spikes sorting a computationally expensive task. New Method: We optimized a previously described detection method, based on the scaled median of absolute deviations (MED) that is more accurate during high rates of neuronal firing. In addition, we added a step to de-duplicate (DP) spikes recorded on multiple electrodes, which enhanced the accuracy of MED. The combined method of detection and de-duplication (DP-MED) is less computationally expensive and easier to implement than popular sorting alternatives like Kilosort-4. Results and Conclusions: During burst periods, the MED-based method detected over half of spikes that were undetected by the RMS-based method. To evaluate the performance of DP-MED, we simulated data that emulates neuronal activity recorded with HD-MEA. Across increasing firing rates, DP-MED shows more precision than Kilosort-4 but is slightly less accurate. After inducing high firing rate in cortical cultures with pharmacological stimulation, DP-MED detected a similar number of spikes than Kilosort-4, however, the analysis in Kilosort-4 was 40-fold more time-consuming. These results highlight the effectiveness of the DP-MED method in the context of drug screening using HD-MEAs.
Open AccessA fast and simple algorithm for accurate spike detection in HD-MEA recordings
Background: High density microelectrode arrays provide a strong platform to study individual neuronal activity and neuronal network dynamics. However, the analysis of high volume and complex data present several challenges. Common spike detection methods based on Root-Mean-Square (RMS) threshold crossing underestimate the number of spikes during neuronal bursting, which frequently occurs in neuronal cultures. In addition, the detection of action potentials by multiple electrodes makes spikes sorting a computationally expensive task. New Method: We optimized a previously described detection method, based on the scaled median of absolute deviations (MED) that is more accurate during high rates of neuronal firing. In addition, we added a step to de-duplicate (DP) spikes recorded on multiple electrodes, which enhanced the accuracy of MED. The combined method of detection and de-duplication (DP-MED) is less computationally expensive and easier to implement than popular sorting alternatives like Kilosort-4. Results and Conclusions: During burst periods, the MED-based method detected over half of spikes that were undetected by the RMS-based method. To evaluate the performance of DP-MED, we simulated data that emulates neuronal activity recorded with HD-MEA. Across increasing firing rates, DP-MED shows more precision than Kilosort-4 but is slightly less accurate. After inducing high firing rate in cortical cultures with pharmacological stimulation, DP-MED detected a similar number of spikes than Kilosort-4, however, the analysis in Kilosort-4 was 40-fold more time-consuming. These results highlight the effectiveness of the DP-MED method in the context of drug screening using HD-MEAs.
- 25 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Circuits and Systems Magazine
- Vol. 25 (3) , 73-79
Advancing Healthcare Through Wearable Technology: Key Takeaways From the IEEE CASS Workshop on Medical Wearables [CASS Conference Highlights]
The IEEE CASS Workshop on Medical Wearables, held on October 27, 2024, in Xi’an, China, focused on the impact of wearable technologies in healthcare. Experts gathered to discuss advancements in sensor design, power management, and data transmission for wearable devices, highlighting how they enable continuous health monitoring and improve patient care. Key topics included challenges in miniaturization, energy efficiency, and the need for standardized data protocols for interoperability. The presentations featured several recent innovations like galvanic body-coupled power transfer, non-invasive blood gas monitoring, and AI-driven EEG and auscultation diagnostics. The workshop also addressed commercialization barriers, including regulatory requirements, intellectual property, and user-centered design. Emphasizing interdisciplinary collaboration, the event explored how wearables can be integrated into healthcare systems for proactive, personalized care. Emerging AI, telemedicine, and bio-sensing trends are poised to revolutionize patient management, making continuous, remote monitoring more accessible and practical. The workshop concluded with a note of optimism about the future potential of medical wearables to reshape healthcare delivery globally.
- 25 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Circuits and Systems Magazine
- Vol. 25 (3) , 73-79
Advancing Healthcare Through Wearable Technology: Key Takeaways From the IEEE CASS Workshop on Medical Wearables [CASS Conference Highlights]
The IEEE CASS Workshop on Medical Wearables, held on October 27, 2024, in Xi’an, China, focused on the impact of wearable technologies in healthcare. Experts gathered to discuss advancements in sensor design, power management, and data transmission for wearable devices, highlighting how they enable continuous health monitoring and improve patient care. Key topics included challenges in miniaturization, energy efficiency, and the need for standardized data protocols for interoperability. The presentations featured several recent innovations like galvanic body-coupled power transfer, non-invasive blood gas monitoring, and AI-driven EEG and auscultation diagnostics. The workshop also addressed commercialization barriers, including regulatory requirements, intellectual property, and user-centered design. Emphasizing interdisciplinary collaboration, the event explored how wearables can be integrated into healthcare systems for proactive, personalized care. Emerging AI, telemedicine, and bio-sensing trends are poised to revolutionize patient management, making continuous, remote monitoring more accessible and practical. The workshop concluded with a note of optimism about the future potential of medical wearables to reshape healthcare delivery globally.
- Open Access
- 10 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0300526
Interpretable dimensionality reduction and classification of mass spectrometry imaging data in a visceral pain model via non-negative matrix factorization
Mass spectrometry imaging (MSI) is a powerful scientific tool for understanding the spatial distribution of biochemical compounds in tissue structures. In this paper, we introduce three novel approaches in MSI data processing to perform the tasks of data augmentation, feature ranking, and image registration. We use these approaches in conjunction with non-negative matrix factorization (NMF) to resolve two of the biggest challenges in MSI data analysis, namely: 1) the large file sizes and associated computational resource requirements and 2) the complexity of interpreting the very high dimensional raw spectral data. There are many dimensionality reduction techniques that address the first challenge but do not necessarily result in readily interpretable features, leaving the second challenge unaddressed. We demonstrate that NMF is an effective dimensionality reduction algorithm that reduces the size of MSI datasets by three orders of magnitude with limited loss of information, yielding spatial and spectral components with meaningful correlation to tissue structure that may be used directly for subsequent data analysis without the need for additional clustering steps. This analysis is demonstrated on an MSI dataset from female Sprague-Dawley rats for an animal model of comorbid visceral pain hypersensitivity (CPH). We find that high-dimensional MSI data (∼ 100,000 ions per pixel) can be reduced to 20 spectral NMF components with < 20% loss in reconstruction accuracy. The resulting spatial NMF components are reproducible and correlate well with H&E-stained tissue images. These components may also be used to generate images with enhanced specificity for different tissue types. Small patches of NMF data (i.e., 20 spatial NMF components over 20 × 20 pixels) provide an accuracy of ∼ 87% in classifying CPH vs naïve control subjects. This paper presents the novel data processing methodologies that were used to produce these results, encompassing novel data processing pipelines for data augmentation to support training for classification, ranking of features according to their contribution to classification, and image registration to enhance tissue-specific imaging.
- 10 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0300526
Open AccessInterpretable dimensionality reduction and classification of mass spectrometry imaging data in a visceral pain model via non-negative matrix factorization
Mass spectrometry imaging (MSI) is a powerful scientific tool for understanding the spatial distribution of biochemical compounds in tissue structures. In this paper, we introduce three novel approaches in MSI data processing to perform the tasks of data augmentation, feature ranking, and image registration. We use these approaches in conjunction with non-negative matrix factorization (NMF) to resolve two of the biggest challenges in MSI data analysis, namely: 1) the large file sizes and associated computational resource requirements and 2) the complexity of interpreting the very high dimensional raw spectral data. There are many dimensionality reduction techniques that address the first challenge but do not necessarily result in readily interpretable features, leaving the second challenge unaddressed. We demonstrate that NMF is an effective dimensionality reduction algorithm that reduces the size of MSI datasets by three orders of magnitude with limited loss of information, yielding spatial and spectral components with meaningful correlation to tissue structure that may be used directly for subsequent data analysis without the need for additional clustering steps. This analysis is demonstrated on an MSI dataset from female Sprague-Dawley rats for an animal model of comorbid visceral pain hypersensitivity (CPH). We find that high-dimensional MSI data (∼ 100,000 ions per pixel) can be reduced to 20 spectral NMF components with < 20% loss in reconstruction accuracy. The resulting spatial NMF components are reproducible and correlate well with H&E-stained tissue images. These components may also be used to generate images with enhanced specificity for different tissue types. Small patches of NMF data (i.e., 20 spatial NMF components over 20 × 20 pixels) provide an accuracy of ∼ 87% in classifying CPH vs naïve control subjects. This paper presents the novel data processing methodologies that were used to produce these results, encompassing novel data processing pipelines for data augmentation to support training for classification, ranking of features according to their contribution to classification, and image registration to enhance tissue-specific imaging.
- Open Access
Interpretable dimensionality reduction and classification of mass spectrometry imaging data in a visceral pain model via non-negative matrix factorization
Mass spectrometry imaging (MSI) is a powerful scientific tool for understanding the spatial distribution of biochemical compounds in tissue structures. MSI data analysis presents problems due to the large file sizes and computational resource requirements and also due to the complexity of interpreting the raw spectral data. Dimensionality reduction techniques that address the first issue do not necessarily result in readily interpretable features. In this paper, we present non-negative matrix factorization (NMF) as a dimensionality reduction algorithm that reduces the size of MSI datasets by three orders of magnitude with limited loss of information, yielding spatial and spectral components with meaningful correlation to tissue structure. This analysis is demonstrated on an MSI dataset from female Sprague-Dawley rats for an animal model of comorbid visceral pain hypersensitivity (CPH). The significant findings are: 1) High-dimensional MSI data ( ∼ 100,000 ions per pixel) was reduced to 20 spectral NMF components with < 20% loss in reconstruction accuracy. 2) Spatial NMF components are reproducible and correlate well with H&E-stained tissue images. 3) Spatial NMF components may be used to provide images with enhanced specificity for different tissue types. 4) Small patches of NMF data (i.e., 20 spatial NMF components over 20 x 20 pixels) provide an accuracy of ∼ 87% in classifying CPH vs näıve control subjects. This paper presents novel methodologies for data augmentation to support classification, ranking of features according to their contribution to classification, and image registration to support tissue-specific imaging.
Open AccessInterpretable dimensionality reduction and classification of mass spectrometry imaging data in a visceral pain model via non-negative matrix factorization
Mass spectrometry imaging (MSI) is a powerful scientific tool for understanding the spatial distribution of biochemical compounds in tissue structures. MSI data analysis presents problems due to the large file sizes and computational resource requirements and also due to the complexity of interpreting the raw spectral data. Dimensionality reduction techniques that address the first issue do not necessarily result in readily interpretable features. In this paper, we present non-negative matrix factorization (NMF) as a dimensionality reduction algorithm that reduces the size of MSI datasets by three orders of magnitude with limited loss of information, yielding spatial and spectral components with meaningful correlation to tissue structure. This analysis is demonstrated on an MSI dataset from female Sprague-Dawley rats for an animal model of comorbid visceral pain hypersensitivity (CPH). The significant findings are: 1) High-dimensional MSI data ( ∼ 100,000 ions per pixel) was reduced to 20 spectral NMF components with < 20% loss in reconstruction accuracy. 2) Spatial NMF components are reproducible and correlate well with H&E-stained tissue images. 3) Spatial NMF components may be used to provide images with enhanced specificity for different tissue types. 4) Small patches of NMF data (i.e., 20 spatial NMF components over 20 x 20 pixels) provide an accuracy of ∼ 87% in classifying CPH vs näıve control subjects. This paper presents novel methodologies for data augmentation to support classification, ranking of features according to their contribution to classification, and image registration to support tissue-specific imaging.
- 1 January 2022
- Published by Springer Nature
- p. 553-570
CMOS Capacitance Biosensors to Monitor Cell Viability
- 1 January 2022
- Published by Springer Nature
- p. 553-570
CMOS Capacitance Biosensors to Monitor Cell Viability
- 1 January 2020
- Published by Springer Nature
- p. 1-18
CMOS Capacitance Biosensors to Monitor Cell Viability
- 1 January 2020
- Published by Springer Nature
- p. 1-18
CMOS Capacitance Biosensors to Monitor Cell Viability
- 1 October 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 142, 111501
High resolution monitoring of chemotherapeutic agent potency in cancer cells using a CMOS capacitance biosensor
- 1 October 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 142, 111501
High resolution monitoring of chemotherapeutic agent potency in cancer cells using a CMOS capacitance biosensor
- 4 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1214-1225
Correlation of Capacitance and Microscopy Measurements Using Image Processing for a Lab-on-CMOS Microsystem
We present a capacitance sensor chip developed in a 0.35 μm CMOS process for monitoring biological cell viability and proliferation. The chip measures cell-to-substrate binding through capacitance-to-frequency conversion with a sensitivity of 590 kHz/fF. In vitro experiments with two human ovarian cancer cell lines (CP70, A2780) were performed and showed the ability to track cell viability in real-time over three days. An imaging platform was developed to provide time-lapse images of the sensor surface, which allowed for concurrent visual and capacitance observation of the cells. Results showed the ability to detect single cell binding events and changes in cell morphology. Image processing was performed to estimate cell coverage of sensor electrodes, showing good linear correlation and providing a sensor gain of 1.28 $\pm$ 0.29 aF/μm2, which agrees with values reported in literature. The device is designed for unsupervised operation with minimal packaging requirements. Only a microcontroller is required for readout, making it suitable for applications outside the traditional laboratory setting.- 4 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1214-1225
Correlation of Capacitance and Microscopy Measurements Using Image Processing for a Lab-on-CMOS Microsystem
We present a capacitance sensor chip developed in a 0.35 μm CMOS process for monitoring biological cell viability and proliferation. The chip measures cell-to-substrate binding through capacitance-to-frequency conversion with a sensitivity of 590 kHz/fF. In vitro experiments with two human ovarian cancer cell lines (CP70, A2780) were performed and showed the ability to track cell viability in real-time over three days. An imaging platform was developed to provide time-lapse images of the sensor surface, which allowed for concurrent visual and capacitance observation of the cells. Results showed the ability to detect single cell binding events and changes in cell morphology. Image processing was performed to estimate cell coverage of sensor electrodes, showing good linear correlation and providing a sensor gain of 1.28 $\pm$ 0.29 aF/μm2, which agrees with values reported in literature. The device is designed for unsupervised operation with minimal packaging requirements. Only a microcontroller is required for readout, making it suitable for applications outside the traditional laboratory setting.- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (3) , 510-520
Real-Time Measurements of Cell Proliferation Using a Lab-on-CMOS Capacitance Sensor Array
We describe a capacitance sensor array that has been incorporated into a lab-on-CMOS system for applications in monitoring cell viability. This paper presents analytical models, calibration results, and measured experimental results of the biosensor. The sensor has been characterized and exhibits a sensitivity of 590 kHz/fF. We report results from benchtop tests and in vitro experiments demonstrating on-chip tracking of cell adhesion as well as monitoring of cell viability. Human ovarian cancer cells were cultured on chip, and measured capacitance responses were validated by comparison with images from photomicrographs of the chip surface. Analysis was performed to quantify cell proliferation and adhesion, and responses to live cells were estimated to be 100 aF/cell.
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (3) , 510-520
Real-Time Measurements of Cell Proliferation Using a Lab-on-CMOS Capacitance Sensor Array
We describe a capacitance sensor array that has been incorporated into a lab-on-CMOS system for applications in monitoring cell viability. This paper presents analytical models, calibration results, and measured experimental results of the biosensor. The sensor has been characterized and exhibits a sensitivity of 590 kHz/fF. We report results from benchtop tests and in vitro experiments demonstrating on-chip tracking of cell adhesion as well as monitoring of cell viability. Human ovarian cancer cells were cultured on chip, and measured capacitance responses were validated by comparison with images from photomicrographs of the chip surface. Analysis was performed to quantify cell proliferation and adhesion, and responses to live cells were estimated to be 100 aF/cell.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 24 (10) , 3156-3168
Frequency-Boost Jitter Reduction for Voltage-Controlled Ring Oscillators
Ring oscillators (ROs) are popular due to their small area, modest power, wide tuning range, and ease of scaling with process technology. However, their use in many applications is limited due to poor phase noise and jitter performance. Thermal noise and flicker noise contribute jitter that decreases inversely with oscillation frequency. This paper describes a frequency-boost technique to reduce jitter in ROs. We boost the internal oscillation frequency and introduce a frequency divider following the oscillator to maintain the desired output frequency. This approach offers reduced jitter as well as the opportunity to trade off output jitter with power for dynamic performance management. The oscillator has 32 operating modes, corresponding to different values for the ring size and frequency division. In a 0.5-μm CMOS process, the highest oscillation frequency achieved is 25 MHz with a root-mean-square period jitter of 54 ps and a power consumption of 817 μW at 5 V supply. A jitter model for current-starved oscillators was derived and verified by measurement; a direct relationship between oscillation frequency and jitter was derived and measured. Compared with other oscillators, this design achieves the highest performance in terms of jitter per unit interval and figure-of-merit. The performance is expected to improve in more advanced technologies. The results are summarized to offer design guidance based on the frequency-boost technique.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 24 (10) , 3156-3168
Frequency-Boost Jitter Reduction for Voltage-Controlled Ring Oscillators
Ring oscillators (ROs) are popular due to their small area, modest power, wide tuning range, and ease of scaling with process technology. However, their use in many applications is limited due to poor phase noise and jitter performance. Thermal noise and flicker noise contribute jitter that decreases inversely with oscillation frequency. This paper describes a frequency-boost technique to reduce jitter in ROs. We boost the internal oscillation frequency and introduce a frequency divider following the oscillator to maintain the desired output frequency. This approach offers reduced jitter as well as the opportunity to trade off output jitter with power for dynamic performance management. The oscillator has 32 operating modes, corresponding to different values for the ring size and frequency division. In a 0.5-μm CMOS process, the highest oscillation frequency achieved is 25 MHz with a root-mean-square period jitter of 54 ps and a power consumption of 817 μW at 5 V supply. A jitter model for current-starved oscillators was derived and verified by measurement; a direct relationship between oscillation frequency and jitter was derived and measured. Compared with other oscillators, this design achieves the highest performance in terms of jitter per unit interval and figure-of-merit. The performance is expected to improve in more advanced technologies. The results are summarized to offer design guidance based on the frequency-boost technique.