Sheung Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sheung Lu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bathiya Prashan Senevirathna
Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA; Institute for Systems Research, University of Maryland, College Park, MD, USA
3 shared publications - Elisabeth Smela
Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
3 shared publications - Pamela Abshire
Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, United States
3 shared publications Bathiya Senevirathna
University of Maryland, Dept. of Electrical and Computer Engineering, College Park
2 shared publications- John R. Basile
Department of Oncology and Diagnostic Sciences, University of Maryland Dental School, 650 West Baltimore Street, 7-North, Baltimore, MD, 21201, USA.
2 shared publications - Marc Dandin
Department of Electrical and Computer Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
2 shared publications
Latest Publications
- 1 October 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 142, 111501
High resolution monitoring of chemotherapeutic agent potency in cancer cells using a CMOS capacitance biosensor
- 1 October 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 142, 111501
High resolution monitoring of chemotherapeutic agent potency in cancer cells using a CMOS capacitance biosensor
- 4 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1214-1225
Correlation of Capacitance and Microscopy Measurements Using Image Processing for a Lab-on-CMOS Microsystem
We present a capacitance sensor chip developed in a 0.35 μm CMOS process for monitoring biological cell viability and proliferation. The chip measures cell-to-substrate binding through capacitance-to-frequency conversion with a sensitivity of 590 kHz/fF. In vitro experiments with two human ovarian cancer cell lines (CP70, A2780) were performed and showed the ability to track cell viability in real-time over three days. An imaging platform was developed to provide time-lapse images of the sensor surface, which allowed for concurrent visual and capacitance observation of the cells. Results showed the ability to detect single cell binding events and changes in cell morphology. Image processing was performed to estimate cell coverage of sensor electrodes, showing good linear correlation and providing a sensor gain of 1.28 $\pm$ 0.29 aF/μm2, which agrees with values reported in literature. The device is designed for unsupervised operation with minimal packaging requirements. Only a microcontroller is required for readout, making it suitable for applications outside the traditional laboratory setting.- 4 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1214-1225
Correlation of Capacitance and Microscopy Measurements Using Image Processing for a Lab-on-CMOS Microsystem
We present a capacitance sensor chip developed in a 0.35 μm CMOS process for monitoring biological cell viability and proliferation. The chip measures cell-to-substrate binding through capacitance-to-frequency conversion with a sensitivity of 590 kHz/fF. In vitro experiments with two human ovarian cancer cell lines (CP70, A2780) were performed and showed the ability to track cell viability in real-time over three days. An imaging platform was developed to provide time-lapse images of the sensor surface, which allowed for concurrent visual and capacitance observation of the cells. Results showed the ability to detect single cell binding events and changes in cell morphology. Image processing was performed to estimate cell coverage of sensor electrodes, showing good linear correlation and providing a sensor gain of 1.28 $\pm$ 0.29 aF/μm2, which agrees with values reported in literature. The device is designed for unsupervised operation with minimal packaging requirements. Only a microcontroller is required for readout, making it suitable for applications outside the traditional laboratory setting.- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (3) , 510-520
Real-Time Measurements of Cell Proliferation Using a Lab-on-CMOS Capacitance Sensor Array
We describe a capacitance sensor array that has been incorporated into a lab-on-CMOS system for applications in monitoring cell viability. This paper presents analytical models, calibration results, and measured experimental results of the biosensor. The sensor has been characterized and exhibits a sensitivity of 590 kHz/fF. We report results from benchtop tests and in vitro experiments demonstrating on-chip tracking of cell adhesion as well as monitoring of cell viability. Human ovarian cancer cells were cultured on chip, and measured capacitance responses were validated by comparison with images from photomicrographs of the chip surface. Analysis was performed to quantify cell proliferation and adhesion, and responses to live cells were estimated to be 100 aF/cell.
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (3) , 510-520
Real-Time Measurements of Cell Proliferation Using a Lab-on-CMOS Capacitance Sensor Array
We describe a capacitance sensor array that has been incorporated into a lab-on-CMOS system for applications in monitoring cell viability. This paper presents analytical models, calibration results, and measured experimental results of the biosensor. The sensor has been characterized and exhibits a sensitivity of 590 kHz/fF. We report results from benchtop tests and in vitro experiments demonstrating on-chip tracking of cell adhesion as well as monitoring of cell viability. Human ovarian cancer cells were cultured on chip, and measured capacitance responses were validated by comparison with images from photomicrographs of the chip surface. Analysis was performed to quantify cell proliferation and adhesion, and responses to live cells were estimated to be 100 aF/cell.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
System Integration of IC chips for Lab-on-CMOS Applications
Integrating CMOS sensor chips to allow for wet experimentation on lab-on-CMOS devices is a challenging task. In this paper we describe a chip packaging method that will allow for simple integration and handling of small integrated circuit (IC) chips. A chip is embedded in an epoxy handle wafer to allow for photolithographic processing. Electrical connections are provided by a sputter-deposited copper layer and an electroplated nickel layer. Passivation was performed using a second epoxy layer. The process was evaluated by packaging a capacitance sensor chip and performing live cell culture experiments with package cleaning and reuse. Results showed good structural reliability in three repeated experiments over five cumulative days, with no adverse effects on the viability of cells.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
System Integration of IC chips for Lab-on-CMOS Applications
Integrating CMOS sensor chips to allow for wet experimentation on lab-on-CMOS devices is a challenging task. In this paper we describe a chip packaging method that will allow for simple integration and handling of small integrated circuit (IC) chips. A chip is embedded in an epoxy handle wafer to allow for photolithographic processing. Electrical connections are provided by a sputter-deposited copper layer and an electroplated nickel layer. Passivation was performed using a second epoxy layer. The process was evaluated by packaging a capacitance sensor chip and performing live cell culture experiments with package cleaning and reuse. Results showed good structural reliability in three repeated experiments over five cumulative days, with no adverse effects on the viability of cells.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Characterization of a high dynamic range lab-on-CMOS capacitance sensor array
We describe a capacitance sensor array that has been incorporated into a lab-on-CMOS system for applications in monitoring cell viability. This paper presents measured experimental results of a high dynamic range capacitance sensor array. The sensors have been characterized and the data fitted to analytical models, allowing end-to-end calibration of the responses. The sensor exhibits a sensitivity of up to 593 kHz/fF, resolution down to 17.5 aF, and an input sensing range of 12 fF.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Characterization of a high dynamic range lab-on-CMOS capacitance sensor array
We describe a capacitance sensor array that has been incorporated into a lab-on-CMOS system for applications in monitoring cell viability. This paper presents measured experimental results of a high dynamic range capacitance sensor array. The sensors have been characterized and the data fitted to analytical models, allowing end-to-end calibration of the responses. The sensor exhibits a sensitivity of up to 593 kHz/fF, resolution down to 17.5 aF, and an input sensing range of 12 fF.
- Open Access
- 16 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (12) , 4955-4967
Event-Driven Low-Power Gesture Recognition Using Differential Capacitance
Individuals with mobility impairments represent a large portion of the population. These impairments are often the sequels of strokes, spinal cord injury, or diseases, such as amyotrophic lateral sclerosis and Guillain-Barré syndrome. Many of these diagnoses manifest in upper-extremity mobility impairment, which may prohibit or make difficult actuating devices within the home. While solutions exist for smart-home automation and control, a few are approachable by those with mobility impairments. To address this issue, we designed Inviz, a touchless low-power assistive gesture recognition system that utilizes an array of textile capacitive sensors to control a smart-home automation system. We present two novel research contributions; the use of flexible textile-based capacitive arrays as differential proximity sensors, and a low-power event-driven hierarchical signal processing algorithm for capacitor sensor arrays. A fully functional prototype system is implemented and evaluated in the context of an end-to-end home automation system using intuitive swipe and hover gestures that are comfortable and approachable for users with mobility impairments. The evaluation demonstrates that the system achieves high accuracy (>90%) while maintaining low latency (<;1 s) and low energy consumption (2475 μW). In addition, we evaluate the system on a subject with upper extremity mobility impairment to verify its usage as an accessibility device.
- 16 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (12) , 4955-4967
Open AccessEvent-Driven Low-Power Gesture Recognition Using Differential Capacitance
Individuals with mobility impairments represent a large portion of the population. These impairments are often the sequels of strokes, spinal cord injury, or diseases, such as amyotrophic lateral sclerosis and Guillain-Barré syndrome. Many of these diagnoses manifest in upper-extremity mobility impairment, which may prohibit or make difficult actuating devices within the home. While solutions exist for smart-home automation and control, a few are approachable by those with mobility impairments. To address this issue, we designed Inviz, a touchless low-power assistive gesture recognition system that utilizes an array of textile capacitive sensors to control a smart-home automation system. We present two novel research contributions; the use of flexible textile-based capacitive arrays as differential proximity sensors, and a low-power event-driven hierarchical signal processing algorithm for capacitor sensor arrays. A fully functional prototype system is implemented and evaluated in the context of an end-to-end home automation system using intuitive swipe and hover gestures that are comfortable and approachable for users with mobility impairments. The evaluation demonstrates that the system achieves high accuracy (>90%) while maintaining low latency (<;1 s) and low energy consumption (2475 μW). In addition, we evaluate the system on a subject with upper extremity mobility impairment to verify its usage as an accessibility device.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 208-210
Demo abstract: A microphone sensor based system for green building applications
Acoustic sensing has influenced many applications in green building energy management, such as designing multi-modal energy disaggregation algorithms through fine-grained appliance state identifications or efficiently controlling the HVAC system based on the occupancy of the environment. In this demo paper we build a low-cost system prototype using off-the-shelf commercially available hardware (Raspberry Pi and super high gain microphone) to handle both acoustic sensing and its processing that is portable and easily deployable in any indoor environment. Our system is useful in detecting appliance noise for fine-grained energy metering and human voice for managing building energy footprint. We use the decibel strength of the sound to determine if it should be filtered out as a silence or stored in as an audio of interest. A fast fourier transform that quickly converts the sinusoidal input of the audio signals into its associated frequencies is implemented along with the Mel-Frequency Cepstral Coefficients (MFCCs) feature to distinguish between a human voice and an appliance noise. We also implement all the computations on-chip to quantify the energy-delay benefits.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 208-210
Demo abstract: A microphone sensor based system for green building applications
Acoustic sensing has influenced many applications in green building energy management, such as designing multi-modal energy disaggregation algorithms through fine-grained appliance state identifications or efficiently controlling the HVAC system based on the occupancy of the environment. In this demo paper we build a low-cost system prototype using off-the-shelf commercially available hardware (Raspberry Pi and super high gain microphone) to handle both acoustic sensing and its processing that is portable and easily deployable in any indoor environment. Our system is useful in detecting appliance noise for fine-grained energy metering and human voice for managing building energy footprint. We use the decibel strength of the sound to determine if it should be filtered out as a silence or stored in as an audio of interest. A fast fourier transform that quickly converts the sinusoidal input of the audio signals into its associated frequencies is implemented along with the Mel-Frequency Cepstral Coefficients (MFCCs) feature to distinguish between a human voice and an appliance noise. We also implement all the computations on-chip to quantify the energy-delay benefits.