Lan Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lan Xiao has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Qunfang Wu
Nanjing University of Aeronautics and Astronautics
16 shared publications - Qin Wang
Nanjing University of Aeronautics and Astronautics
13 shared publications - Chuyang Wang
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
8 shared publications - Jinbo Li
Department of Automation Engineering Nanjing University of Aeronautics and Astronautics Nanjing China
5 shared publications - Huijie Jiang
Nanjing, Jiangsu China
4 shared publications Qin Wang
Nanjing University of Aeronautics and Astronautics, Nanjing, China
4 shared publications
Latest Publications
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (8) , 13291-13302
The Decoupling Magnetic Integration Method and Global Loss Optimization for LLC -DAB Hybrid Converter With Circuit State Correlation
The LLC-DAB quasi-parallel hybrid converter (LDHC) exhibits both excellent efficiency and voltage regulation capability. However, a large number of transformer units and bulky magnetic components result in low power density and low efficiency. The existing integration methods for magnetic components in such hybrid converters rely on the decoupling of the common magnetic circuit and introduce an additional magnetic core structure. This paper presents an integration method for LDHC transformers that eliminates the common magnetic circuit and derives the design boundaries for the magnetic core under decoupling conditions. The correlation model between the structure of DAB magnetic components and circuit states was established, and the optimization of the magnetic component structure, considering volume and global loss, was realized using the particle swarm optimization (PSO) algorithm. Finally, two 750V/48V@2.5kW prototypes were built, and experiments demonstrated that the proposed method improved peak efficiency by 1.24%. The power density of the integrated magnetic core reached 690W/in3, which was 16.97% higher than that of the discrete integrated prototype.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (8) , 13291-13302
The Decoupling Magnetic Integration Method and Global Loss Optimization for LLC -DAB Hybrid Converter With Circuit State Correlation
The LLC-DAB quasi-parallel hybrid converter (LDHC) exhibits both excellent efficiency and voltage regulation capability. However, a large number of transformer units and bulky magnetic components result in low power density and low efficiency. The existing integration methods for magnetic components in such hybrid converters rely on the decoupling of the common magnetic circuit and introduce an additional magnetic core structure. This paper presents an integration method for LDHC transformers that eliminates the common magnetic circuit and derives the design boundaries for the magnetic core under decoupling conditions. The correlation model between the structure of DAB magnetic components and circuit states was established, and the optimization of the magnetic component structure, considering volume and global loss, was realized using the particle swarm optimization (PSO) algorithm. Finally, two 750V/48V@2.5kW prototypes were built, and experiments demonstrated that the proposed method improved peak efficiency by 1.24%. The power density of the integrated magnetic core reached 690W/in3, which was 16.97% higher than that of the discrete integrated prototype.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP  (21686777) , 1
A Soft-Switching Hybrid Control Strategy Based on DPWM for SiC Asynchronous Parallel Three-Phase Inverters
Aviation converters impose stringent requirements for high-frequency and high-efficiency operation on three-phase inverters. However, SiC-based three-phase inverters still experience significant switching losses at high switching frequencies, which limits further improvements in both switching frequency and system efficiency. To address these challenges, this paper proposes a zero-voltage switching (ZVS) hybrid control strategy for SiC asynchronous parallel three-phase inverters. The proposed strategy integrates discontinuous pulse width modulation (DPWM), quadrilateral current mode (QCM), and clamping mode, in which the clamping interval is optimally configured within each fundamental cycle to ensure ZVS of the power devices throughout the entire cycle. This approach effectively reduces current stress and conduction losses under heavy-load conditions and thus enhances system efficiency. For cases with load power factors less than unity, the DPWM strategy dynamically adjusts the position of the clamping interval by compensating the zero-sequence voltage component so that the interval aligns with the peak phase current, thereby further optimizing system loss distribution. Additionally, a transition interval is introduced during the changeover between clamping and QCM intervals to further mitigate current stress. The operation principle of the proposed hybrid control is systematically analyzed, including the amplitude and optimization of current stress in QCM mode and the relationship between the power factor and the zero-sequence component. Finally, a 6 kVA, 200 kHz SiC inverter prototype was developed to validate the proposed strategy. Experimental results demonstrate that the proposed scheme achieves an efficiency of 98.6% at full load, thereby confirming the effectiveness and engineering feasibility of the proposed control method.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP  (21686777) , 1
A Soft-Switching Hybrid Control Strategy Based on DPWM for SiC Asynchronous Parallel Three-Phase Inverters
Aviation converters impose stringent requirements for high-frequency and high-efficiency operation on three-phase inverters. However, SiC-based three-phase inverters still experience significant switching losses at high switching frequencies, which limits further improvements in both switching frequency and system efficiency. To address these challenges, this paper proposes a zero-voltage switching (ZVS) hybrid control strategy for SiC asynchronous parallel three-phase inverters. The proposed strategy integrates discontinuous pulse width modulation (DPWM), quadrilateral current mode (QCM), and clamping mode, in which the clamping interval is optimally configured within each fundamental cycle to ensure ZVS of the power devices throughout the entire cycle. This approach effectively reduces current stress and conduction losses under heavy-load conditions and thus enhances system efficiency. For cases with load power factors less than unity, the DPWM strategy dynamically adjusts the position of the clamping interval by compensating the zero-sequence voltage component so that the interval aligns with the peak phase current, thereby further optimizing system loss distribution. Additionally, a transition interval is introduced during the changeover between clamping and QCM intervals to further mitigate current stress. The operation principle of the proposed hybrid control is systematically analyzed, including the amplitude and optimization of current stress in QCM mode and the relationship between the power factor and the zero-sequence component. Finally, a 6 kVA, 200 kHz SiC inverter prototype was developed to validate the proposed strategy. Experimental results demonstrate that the proposed scheme achieves an efficiency of 98.6% at full load, thereby confirming the effectiveness and engineering feasibility of the proposed control method.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (5) , 8065-8077
A Current Sharing Strategy With Model Predictive Control for Multiphase Parallel LLC -Buck Converters
Input-series-output-parallel (ISOP) LLC-Buck converters are widely used in energy storage systems for their high efficiency and wide voltage gain range. However, parameter mismatches among parallel modules often cause power imbalance and degraded current sharing. This article proposes a model predictive control (MPC) based current sharing strategy for multiphase LLC-Buck converters. A current-sharing error model is established to analyze the impact of mismatched parameters, including resonant components, magnetizing inductance, switch characteristics, and Buck inductor resistance. Based on this, a fixed-frequency, single-step MPC algorithm is developed, incorporating real-time reference updates and an observer to correct model deviations. Compared with the widely used average current control, the proposed method enhances dynamic response, robustness, and current balance. A 500 W two-phase LLC-Buck prototype (48 V to 3.2 V) is built, and both simulation and experimental results validate the approach, achieving current sharing errors of 0.84% at half-load and 0.27% at full-load.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (5) , 8065-8077
A Current Sharing Strategy With Model Predictive Control for Multiphase Parallel LLC -Buck Converters
Input-series-output-parallel (ISOP) LLC-Buck converters are widely used in energy storage systems for their high efficiency and wide voltage gain range. However, parameter mismatches among parallel modules often cause power imbalance and degraded current sharing. This article proposes a model predictive control (MPC) based current sharing strategy for multiphase LLC-Buck converters. A current-sharing error model is established to analyze the impact of mismatched parameters, including resonant components, magnetizing inductance, switch characteristics, and Buck inductor resistance. Based on this, a fixed-frequency, single-step MPC algorithm is developed, incorporating real-time reference updates and an observer to correct model deviations. Compared with the widely used average current control, the proposed method enhances dynamic response, robustness, and current balance. A 500 W two-phase LLC-Buck prototype (48 V to 3.2 V) is built, and both simulation and experimental results validate the approach, achieving current sharing errors of 0.84% at half-load and 0.27% at full-load.
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (4) , 6280-6289
Multimode Rectifiers With Ultra-Wide Voltage Gain Based on Adjustable Turns Ratio Transformer and Voltage Doubling Structures
For applications such as plug-in electric vehicle battery charging, isolated dc–dc converters are required to accommodate a wide output voltage range. However, existing isolated dc–dc converters exhibit limited voltage gain range and suffer from a drastic efficiency drop under wide voltage range regulation. This article presents a family of rectifier structures utilizing adjustable turns ratio transformers combined with voltage doubling structures, and summarizes the topological deduction laws. The rectifier structure can operate in different gain modes by adjusting the states of secondary switches to expand voltage gain range. Combining LLC converter with one of the proposed rectifiers to obtain a novel resonant converter, which has a wider voltage range compared to existing solutions. The converter can operate in five different voltage gain modes, and the switching frequency of each mode is near the resonant frequency, which helps improve efficiency and soft switching performance. A 2.5 A rated prototype that converts 390 V input to 60–780 V output is designed and tested to validate the solution. The designed prototype demonstrates a peak efficiency of 97.1%.
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (4) , 6280-6289
Multimode Rectifiers With Ultra-Wide Voltage Gain Based on Adjustable Turns Ratio Transformer and Voltage Doubling Structures
For applications such as plug-in electric vehicle battery charging, isolated dc–dc converters are required to accommodate a wide output voltage range. However, existing isolated dc–dc converters exhibit limited voltage gain range and suffer from a drastic efficiency drop under wide voltage range regulation. This article presents a family of rectifier structures utilizing adjustable turns ratio transformers combined with voltage doubling structures, and summarizes the topological deduction laws. The rectifier structure can operate in different gain modes by adjusting the states of secondary switches to expand voltage gain range. Combining LLC converter with one of the proposed rectifiers to obtain a novel resonant converter, which has a wider voltage range compared to existing solutions. The converter can operate in five different voltage gain modes, and the switching frequency of each mode is near the resonant frequency, which helps improve efficiency and soft switching performance. A 2.5 A rated prototype that converts 390 V input to 60–780 V output is designed and tested to validate the solution. The designed prototype demonstrates a peak efficiency of 97.1%.
- 23 June 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25  (12) , 2226-2238
Model prediction-based switch open-circuit fault diagnosis and localization for MMCs
- 23 June 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25  (12) , 2226-2238
Model prediction-based switch open-circuit fault diagnosis and localization for MMCs
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 11985-11990
Self-Excitation, Balanced, Passive Variable Inductor for Fast-Response Buck Converter
To improve the transient response speed of single-phase voltage regulators (VRs), this article proposes a self-excitation, balanced, passive variable inductor for a fast-response buck converter. The dc bias component of the buck converter's inductor current intensifies with increasing load, acting as an excitation source that induces magnetic core saturation, achieving inductance reduction. This method eliminates reliance on external excitation. First, an analytical model for the proposed inductor structure is established and the iterative process is used to solve for the nonlinear magnetic flux density in this article. Then, the optimal design of the structure is achieved by the particle swarm optimization (PSO) algorithm. Finally, three 12 V/3.3 V@50 kHz buck converters were built for experimental comparison. Compared to a fixed inductor, the inductance of the proposed inductor decreases from 33 μH to 16 μH when switching the power from 50 W to 75 W, and the response time of the buck converter decreases from 4 ms to 1.2 ms.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 11985-11990
Self-Excitation, Balanced, Passive Variable Inductor for Fast-Response Buck Converter
To improve the transient response speed of single-phase voltage regulators (VRs), this article proposes a self-excitation, balanced, passive variable inductor for a fast-response buck converter. The dc bias component of the buck converter's inductor current intensifies with increasing load, acting as an excitation source that induces magnetic core saturation, achieving inductance reduction. This method eliminates reliance on external excitation. First, an analytical model for the proposed inductor structure is established and the iterative process is used to solve for the nonlinear magnetic flux density in this article. Then, the optimal design of the structure is achieved by the particle swarm optimization (PSO) algorithm. Finally, three 12 V/3.3 V@50 kHz buck converters were built for experimental comparison. Compared to a fixed inductor, the inductance of the proposed inductor decreases from 33 μH to 16 μH when switching the power from 50 W to 75 W, and the response time of the buck converter decreases from 4 ms to 1.2 ms.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13  (3) , 3516-3528
An Adaptive Fault-Tolerant Control Without Fault Location of Open-Phase Fault for Dual Three-Phase PMSM Drive System
An adaptive fault-tolerant control (FTC) method without fault localization is proposed for the common open-phase faults (OPFs) in dual three-phase permanent magnet synchronous motor (DTP-PMSM) drive systems. The method eliminates the need for fault localization through fault diagnosis, thus reducing the risk of misdiagnosis. The operational state of the DTP-PMSM under OPF is analyzed and a uniform reference current with fault current angle is established in the dual dq coordinate system. After an OPF occurs, the unified current reference can be directly applied to the drive system without fault localization. The fault current angle is acquired by Phase-Locked Loop (PLL), and can still be well acquired even under light load condition. Compared with the existing PLL-based adaptive fault tolerance scheme, one PLL loop is reduced, which reduces the computational burden. The proposed adaptive FTC scheme does not require adjustment of the control framework, machine model and transformation matrix before and after the OPF, and the switching between minimum copper loss, maximum torque output and healthy operation can be achieved by adjusting the amplitude coefficient of the reference current. Experimental results verify the effectiveness of the proposed fault-tolerant control scheme.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13  (3) , 3516-3528
An Adaptive Fault-Tolerant Control Without Fault Location of Open-Phase Fault for Dual Three-Phase PMSM Drive System
An adaptive fault-tolerant control (FTC) method without fault localization is proposed for the common open-phase faults (OPFs) in dual three-phase permanent magnet synchronous motor (DTP-PMSM) drive systems. The method eliminates the need for fault localization through fault diagnosis, thus reducing the risk of misdiagnosis. The operational state of the DTP-PMSM under OPF is analyzed and a uniform reference current with fault current angle is established in the dual dq coordinate system. After an OPF occurs, the unified current reference can be directly applied to the drive system without fault localization. The fault current angle is acquired by Phase-Locked Loop (PLL), and can still be well acquired even under light load condition. Compared with the existing PLL-based adaptive fault tolerance scheme, one PLL loop is reduced, which reduces the computational burden. The proposed adaptive FTC scheme does not require adjustment of the control framework, machine model and transformation matrix before and after the OPF, and the switching between minimum copper loss, maximum torque output and healthy operation can be achieved by adjusting the amplitude coefficient of the reference current. Experimental results verify the effectiveness of the proposed fault-tolerant control scheme.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13  (3) , 3440-3452
An Improved Hybrid ZVS Modulation for SiC High-Frequency Three-Phase Inverter
In recent years, SiC three-phase inverters have been widely used in aviation electric propulsion systems due to their advanced performance. However, some challenges remain, such as the power loss at high-frequency switching and difficulty in further improving efficiency. To solve this problem, we proposed an improved hybrid zero-voltage-switching (ZVS) modulation for the high-frequency SiC three-phase inverter. It combines the variable current band control with the clamping modulation to achieve the ZVS during the full line-cycle, to further improve the efficiency. In this paper, the control target of about 120-degree clamp per phase and the soft-switching resonant period are analyzed in detail, and the variable current band is discussed. Still, the transient process of switching between the clamping mode and the high-frequency modulation mode is presented, which minimizes the additional power loss. Finally, a 5-kW/250 kHz proof-of-concept prototype was built and it can realize a peak efficiency of 98.88%, and the efficiency of the proposed method can be increased by 0.38% compared with existing similar modulation. All theoretical analyses and proposed modulation strategies are verified by the designed prototype.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13  (3) , 3440-3452
An Improved Hybrid ZVS Modulation for SiC High-Frequency Three-Phase Inverter
In recent years, SiC three-phase inverters have been widely used in aviation electric propulsion systems due to their advanced performance. However, some challenges remain, such as the power loss at high-frequency switching and difficulty in further improving efficiency. To solve this problem, we proposed an improved hybrid zero-voltage-switching (ZVS) modulation for the high-frequency SiC three-phase inverter. It combines the variable current band control with the clamping modulation to achieve the ZVS during the full line-cycle, to further improve the efficiency. In this paper, the control target of about 120-degree clamp per phase and the soft-switching resonant period are analyzed in detail, and the variable current band is discussed. Still, the transient process of switching between the clamping mode and the high-frequency modulation mode is presented, which minimizes the additional power loss. Finally, a 5-kW/250 kHz proof-of-concept prototype was built and it can realize a peak efficiency of 98.88%, and the efficiency of the proposed method can be increased by 0.38% compared with existing similar modulation. All theoretical analyses and proposed modulation strategies are verified by the designed prototype.