MPMichael John Parkes

Michael John Parkes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael John Parkes has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 11 May 2026

    Non-invasive mechanical ventilation reduces cardiorespiratory motion and increases heart-stomach distance for stereotactic arrhythmia radiotherapy: a healthy volunteer study.

    by T Weststrate, I W E M van Dijk, J K Veldman-Landegent, Z van Kesteren, M J Parkes, E M T Dieleman, W F Hoeksema, P G Postema, J Visser, N van Wieringen, et al.

    Stereotactic arrhythmia radiotherapy (STAR) is an emerging non-invasive treatment for patients with therapy-refractory ventricular tachycardia (VT). However, STAR's targeting accuracy is challenged by cardiorespiratory motion, which may necessitate compromises in dose delivery to protect nearby organs at risk (OAR), particularly the stomach. Non-invasive mechanical ventilation at 60 breaths per minute with 15cmH₂O positive end-expiratory pressure (NIMV60P) has been shown to reduce respiratory motion and to potentially increase anatomical separation between thoracic structures. This study aimed to quantify the effect of NIMV60P on cardiorespiratory motion of the left diaphragm and the minimal heart-stomach distance. We retrospectively analyzed MRI data from 22 healthy volunteers who underwent two sessions while free-breathing, breath-holding and undergoing NIMV60P. Diaphragm motion was quantified using coronal cine MRIs. The minimal heart-stomach distance was measured using 3D MRIs during breath-hold inhalation (BH-inhalation), exhalation (BH-exhalation), and NIMV60P. Encompassing volumes of the heart and stomach were generated from BH-inhalation and BH-exhalation scans to evaluate overlap or separation during free-breathing. Lastly, cine frames were deformably registered to assess temporal heart-stomach distance variation. NIMV60P significantly reduced median cranial-caudal diaphragm motion by half from 30 mm (IQR: 16 mm) during free-breathing to 15 mm (IQR: 7 mm, p60P, significantly larger than during BH-inhalation (10.3 mm, p=0.04) and BH-exhalation (4.6 mm, p60P significantly reduces diaphragm motion and increases the distance between heart and stomach in healthy volunteers, supporting its integration with STAR to potentially improve targeting and reduce stomach toxicity, especially for inferior wall VT targets.

  • Open Access

    Correction: Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy

    by Z. van Kesteren, J. K. Veldman, M. J. Parkes, M. F. Stevens, P. Balasupramaniam, J. G. van Den Aardweg, G. van Tienhoven, A. Bel, I. W. E. M. van Dijk

  • Open Access

    Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy

    by Z. van Kesteren, J. K. Veldman, M. J. Parkes, M. F. Stevens, P. Balasupramaniam, J. G. van Den Aardweg, G. van Tienhoven, A. Bel, I. W. E. M. van Dijk

    Background: Due to respiratory motion, accurate radiotherapy delivery to thoracic and abdominal tumors is challenging. We aimed to quantify the ability of mechanical ventilation to reduce respiratory motion, by measuring diaphragm motion magnitudes in the same volunteers during free breathing (FB), mechanically regularized breathing (RB) at 22 breaths per minute (brpm), variation in mean diaphragm position across multiple deep inspiration breath-holds (DIBH) and diaphragm drift during single prolonged breath-holds (PBH) in two MRI sessions. Methods: In two sessions, MRIs were acquired from fifteen healthy volunteers who were trained to be mechanically ventilated non-invasively We measured diaphragm motion amplitudes during FB and RB, the inter-quartile range (IQR) of the variation in average diaphragm position from one measurement over five consecutive DIBHs, and diaphragm cranial drift velocities during single PBHs from inhalation (PIBH) and exhalation (PEBH) breath-holds. Results: RB significantly reduced the respiratory motion amplitude by 39%, from median (range) 20.9 (10.6–41.9) mm during FB to 12.8 (6.2–23.8) mm. The median IQR for variation in average diaphragm position over multiple DIBHs was 4.2 (1.0–23.6) mm. During single PIBHs with a median duration of 7.1 (2.0–11.1) minutes, the median diaphragm cranial drift velocity was 3.0 (0.4–6.5) mm/minute. For PEBH, the median duration was 5.8 (1.8–10.2) minutes with 4.4 (1.8–15.1) mm/minute diaphragm drift velocity. Conclusions: Regularized breathing at a frequency of 22 brpm resulted in significantly smaller diaphragm motion amplitudes compared to free breathing. This would enable smaller treatment volumes in radiotherapy. Furthermore, prolonged breath-holding from inhalation and exhalation with median durations of six to seven minutes are feasible. Trial registration: Medical Ethics Committee protocol NL.64693.018.18.


  • Open Access

    Shortening the preparation time of the single prolonged breath-hold for radiotherapy sessions

    by Michael John Parkes, Stuart Green, Jason Cashmore, Qamar Ghafoor, Thomas Clutton-Brock

    Objective: Single prolonged breath-holds of >5 min can be obtained in cancer patients. Currently, however, the preparation time in each radiotherapy session is a practical limitation for clinical adoption of this new technique. Here, we show by how much our original preparation time can be shortened without unduly compromising breath-hold duration. Methods: 44 healthy subjects performed single prolonged breath-holds from 60% O2 and mechanically induced hypocapnia. We tested the effect on breath-hold duration of shortening preparation time (the durations of acclimatization, hyperventilation and hypocapnia) by changing these durations and or ventilator settings. Results: Mean original breath-hold duration was 6.5 ± 0.2 (standard error) min. The total original preparation time (from connecting the facemask to the start of the breath-hold) was 26 ± 1 min. After shortening the hypocapnia duration from 16 to 5 min, mean breath-hold duration was still 6.1 ± 0.2 min (ns vs the original). After abolishing the acclimatization and shortening the hypocapnia to 1 min (a total preparation time now of 9 ± 1 min), a mean breath-hold duration of >5 min was still possible (now significantly shortened to 5.2 ± 0.6 min, p < 0.001). After shorter and more vigorous hyperventilation (lasting 2.7 ± 0.3 min) and shorter hypocapnia (lasting 43 ± 4 s), a mean breath-hold duration of >5 min (5.3 ± 0.2 min, p < 0.05) was still possible. Here, the final total preparation time was 3.5 ± 0.3 min. Conclusions: These improvements may facilitate adoption of the single prolonged breath-hold for a range of thoracic and abdominal radiotherapies especially involving hypofractionation. Advances in knowledge: Multiple short breath-holds improve radiotherapy for thoracic and abdominal cancers. Further improvement may occur by adopting the single prolonged breath-hold of >5 min. One limitation to clinical adoption is its long preparation time. We show here how to reduce the mean preparation time from 26 to 3.5 min without compromising breath-hold duration


  • Open Access

    Safely achieving single prolonged breath-holds of > 5 minutes for radiotherapy in the prone, front crawl position

    by Mj Parkes, Wilfried De Neve, Vincent Vakaet, Geoffrey Heyes, Timothy Jackson, Richard Delaney, Gavin Kirby, Stuart Green, Warren Kilby, Jason Cashmore, et al.

    Objective: Breast cancer radiotherapy is increasingly delivered supine with multiple, short breath-holds. There may be heart and lung sparing advantages for locoregional breast cancer of both prone treatment and in a single breath-hold. We test here whether single prolonged breath-holds are possible in the prone, front crawl position. Methods: 19 healthy volunteers were trained to deliver supine, single prolonged breath-holds with pre-oxygenation and hypocapnia. We tested whether all could achieve the same durations in the prone, front crawl position. Results: 19 healthy volunteers achieved supine, single prolonged breath-holds for mean of 6.2 ± 0.3 min. All were able to hold safely for the same duration while prone (6.1 ± 0.2 min ns. by paired ANOVA). With prone, the increased weight on the chest did not impede chest inflation, nor the ability to hold air in the chest. Thus, the rate of chest deflation (mean anteroposterior deflation movement of three craniocaudally arranged surface markers on the spinal cord) was the same (1.2 ± 0.2, 2.0 ± 0.4 and 1.2 ± 0.4 mm/min) as found previously during supine prolonged breath-holds. No leakage of carbon dioxide or air was detectable into the facemask. Conclusion: Single prolonged (>5 min) breath-holds are equally possible in the prone, front crawl position. Advances in knowledge: Prolonged breath-holds in the front crawl position are possible and have the same durations as in the supine position. Such training would therefore be feasible for some patients with breast cancer requiring loco-regional irradiation. It would have obvious advantages for hypofractionation.


  • Open Access

    Effects of deep inspiration breath hold on prone photon or proton irradiation of breast and regional lymph nodes

    by Bruno Speleers, Max Schoepen, Francesca Belosi, Vincent Vakaet, Wilfried De Neve, Pieter Deseyne, Leen Paelinck, Tom Vercauteren, Michael J. Parkes, Tony Lomax, et al.

    We report on a comparative dosimetrical study between deep inspiration breath hold (DIBH) and shallow breathing (SB) in prone crawl position for photon and proton radiotherapy of whole breast (WB) and locoregional lymph node regions, including the internal mammary chain (LN_MI). We investigate the dosimetrical effects of DIBH in prone crawl position on organs-at-risk for both photon and proton plans. For each modality, we further estimate the effects of lung and heart doses on the mortality risks of different risk profiles of patients. Thirty-one patients with invasive carcinoma of the left breast and pathologically confirmed positive lymph node status were included in this study. DIBH significantly decreased dose to heart for photon and proton radiotherapy. DIBH also decreased lung doses for photons, while increased lung doses were observed using protons because the retracting heart is displaced by low-density lung tissue. For other organs-at-risk, DIBH resulted in significant dose reductions using photons while minor differences in dose deposition between DIBH and SB were observed using protons. In patients with high risks for cardiac and lung cancer mortality, average thirty-year mortality rates from radiotherapy-related cardiac injury and lung cancer were estimated at 3.12% (photon DIBH), 4.03% (photon SB), 1.80% (proton DIBH) and 1.66% (proton SB). The radiation-related mortality risk could not outweigh the ~ 8% disease-specific survival benefit of WB + LN_MI radiotherapy in any of the assessed treatments.


  • Open Access

    Defining short and prolonged breath-holds

    by Michael Parkes, Jason Cashmore, Stuart Green, Thomas Clutton-Brock, Irma Van Dijk, Zdenko van Kesteren, Geertjan van Tienhoven, Arjan Bel, Joost van Den Aardweg, Markus Stevens


  • Open Access

    Hypocapnia Alone Fails to Provoke Important Electrocardiogram Changes in Coronary Artery Diseased Patients

    by Michael J. Parkes, James P. Sheppard, Thomas Barker, Aaron M. Ranasinghe, Eshan Senanayake, Thomas H. Clutton-Brock, Michael P. Frenneaux

    Background: There is still an urgent clinical need to develop non-invasive diagnostic tests for early ischemic heart disease because, once angina occurs, it is too late. Hypocapnia has long been known to cause coronary artery vasoconstriction. Some new cardiology tests are accompanied by the claim that they must have potential diagnostic value if hypocapnia enhances their cardiac effects in healthy subjects. But no previous study has tested whether hypocapnia produces bigger cardiac effects in patients with angina than in healthy subjects. Methods: Severe hypocapnia (a PetCO2 level of 20 mmHg) lasting >15 min was mechanically induced by facemask, while conscious and unmedicated, in 18 healthy subjects and in 10 patients with angina and angiographically confirmed coronary artery disease, awaiting by-pass surgery. Each participant was their own control in normocapnia (where CO2 was added to the inspirate) and the order of normocapnia and hypocapnia was randomized. Twelve lead electrocardiograms (ECG) were recorded and automated measurements were made on all ECG waveforms averaged over >120 beats. 2D echocardiography was also performed on healthy subjects. Results: In the 18 healthy subjects, we confirm that severe hypocapnia (a mean PetCO2 of 20 ± 0 mmHg, P < 0.0001) consistently increased the mean T wave amplitude in leads V1–V3, but by only 31% (P < 0.01), 15% (P < 0.001) and 11% (P < 0.05), respectively. Hypocapnia produced no other significant effects (p > 0.05) on their electro- or echocardiogram. All 10 angina patients tolerated the mechanical hyperventilation well, with minimal discomfort. Hypocpania caused a similar increase in V1 (by 39%, P < 0.05 vs. baseline, but P > 0.05 vs. healthy controls) and did not induce angina. Its effects were no greater in patients who did not take β-blockers, or did not take organic nitrates, or had the worst Canadian Cardiovascular Society scores. Conclusion: Non-invasive mechanical hyperventilation while awake and unmedicated is safe and acceptable, even to patients with angina. Using it to produce severe and prolonged hypocapnia alone does produce significant ECG changes in angina patients. But its potential diagnostic value for identifying patients with coronary stenosis requires further evaluation.


  • Open Access

    The feasibility, safety and optimization of multiple prolonged breath-holds for radiotherapy

    by Michael John Parkes, Stuart Green, Warren Kilby, Jason Cashmore, Qamar Ghafoor, Thomas Henry Clutton-Brock