I. W. E. M. van Dijk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
I. W. E. M. van Dijk has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Arjan Bel
Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
5 shared publications - Zdenko van Kesteren
Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
5 shared publications - Markus F. Stevens
Department of Anaesthesiology, Amsterdam UMC—Location University of Amsterdam , Amsterdam 1105AZ
4 shared publications - Michael John Parkes
Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
4 shared publications - Geertjan van Tienhoven
Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
3 shared publications - Johannes K. Veldman-Landegent
Department of Radiation Oncology, Amsterdam UMC—Location University of Amsterdam , Amsterdam 1105AZ
3 shared publications
Latest Publications
- 11 May 2026
Non-invasive mechanical ventilation reduces cardiorespiratory motion and increases heart-stomach distance for stereotactic arrhythmia radiotherapy: a healthy volunteer study.
Stereotactic arrhythmia radiotherapy (STAR) is an emerging non-invasive treatment for patients with therapy-refractory ventricular tachycardia (VT). However, STAR's targeting accuracy is challenged by cardiorespiratory motion, which may necessitate compromises in dose delivery to protect nearby organs at risk (OAR), particularly the stomach. Non-invasive mechanical ventilation at 60 breaths per minute with 15cmH₂O positive end-expiratory pressure (NIMV60P) has been shown to reduce respiratory motion and to potentially increase anatomical separation between thoracic structures. This study aimed to quantify the effect of NIMV60P on cardiorespiratory motion of the left diaphragm and the minimal heart-stomach distance. We retrospectively analyzed MRI data from 22 healthy volunteers who underwent two sessions while free-breathing, breath-holding and undergoing NIMV60P. Diaphragm motion was quantified using coronal cine MRIs. The minimal heart-stomach distance was measured using 3D MRIs during breath-hold inhalation (BH-inhalation), exhalation (BH-exhalation), and NIMV60P. Encompassing volumes of the heart and stomach were generated from BH-inhalation and BH-exhalation scans to evaluate overlap or separation during free-breathing. Lastly, cine frames were deformably registered to assess temporal heart-stomach distance variation. NIMV60P significantly reduced median cranial-caudal diaphragm motion by half from 30 mm (IQR: 16 mm) during free-breathing to 15 mm (IQR: 7 mm, p60P, significantly larger than during BH-inhalation (10.3 mm, p=0.04) and BH-exhalation (4.6 mm, p60P significantly reduces diaphragm motion and increases the distance between heart and stomach in healthy volunteers, supporting its integration with STAR to potentially improve targeting and reduce stomach toxicity, especially for inferior wall VT targets.
- 11 May 2026
Non-invasive mechanical ventilation reduces cardiorespiratory motion and increases heart-stomach distance for stereotactic arrhythmia radiotherapy: a healthy volunteer study.
Stereotactic arrhythmia radiotherapy (STAR) is an emerging non-invasive treatment for patients with therapy-refractory ventricular tachycardia (VT). However, STAR's targeting accuracy is challenged by cardiorespiratory motion, which may necessitate compromises in dose delivery to protect nearby organs at risk (OAR), particularly the stomach. Non-invasive mechanical ventilation at 60 breaths per minute with 15cmH₂O positive end-expiratory pressure (NIMV60P) has been shown to reduce respiratory motion and to potentially increase anatomical separation between thoracic structures. This study aimed to quantify the effect of NIMV60P on cardiorespiratory motion of the left diaphragm and the minimal heart-stomach distance. We retrospectively analyzed MRI data from 22 healthy volunteers who underwent two sessions while free-breathing, breath-holding and undergoing NIMV60P. Diaphragm motion was quantified using coronal cine MRIs. The minimal heart-stomach distance was measured using 3D MRIs during breath-hold inhalation (BH-inhalation), exhalation (BH-exhalation), and NIMV60P. Encompassing volumes of the heart and stomach were generated from BH-inhalation and BH-exhalation scans to evaluate overlap or separation during free-breathing. Lastly, cine frames were deformably registered to assess temporal heart-stomach distance variation. NIMV60P significantly reduced median cranial-caudal diaphragm motion by half from 30 mm (IQR: 16 mm) during free-breathing to 15 mm (IQR: 7 mm, p60P, significantly larger than during BH-inhalation (10.3 mm, p=0.04) and BH-exhalation (4.6 mm, p60P significantly reduces diaphragm motion and increases the distance between heart and stomach in healthy volunteers, supporting its integration with STAR to potentially improve targeting and reduce stomach toxicity, especially for inferior wall VT targets.
- Open Access
- 14 March 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 38
Benefits of daily online plan adaptation with reduced margins in neoadjuvant chemoradiotherapy for esophageal cancer
- 14 March 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 38
Open AccessBenefits of daily online plan adaptation with reduced margins in neoadjuvant chemoradiotherapy for esophageal cancer
- Open Access
- 28 June 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-2
Correction: Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy
- 28 June 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-2
Open AccessCorrection: Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy
- Open Access
- 21 May 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-11
Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy
Background: Due to respiratory motion, accurate radiotherapy delivery to thoracic and abdominal tumors is challenging. We aimed to quantify the ability of mechanical ventilation to reduce respiratory motion, by measuring diaphragm motion magnitudes in the same volunteers during free breathing (FB), mechanically regularized breathing (RB) at 22 breaths per minute (brpm), variation in mean diaphragm position across multiple deep inspiration breath-holds (DIBH) and diaphragm drift during single prolonged breath-holds (PBH) in two MRI sessions. Methods: In two sessions, MRIs were acquired from fifteen healthy volunteers who were trained to be mechanically ventilated non-invasively We measured diaphragm motion amplitudes during FB and RB, the inter-quartile range (IQR) of the variation in average diaphragm position from one measurement over five consecutive DIBHs, and diaphragm cranial drift velocities during single PBHs from inhalation (PIBH) and exhalation (PEBH) breath-holds. Results: RB significantly reduced the respiratory motion amplitude by 39%, from median (range) 20.9 (10.6–41.9) mm during FB to 12.8 (6.2–23.8) mm. The median IQR for variation in average diaphragm position over multiple DIBHs was 4.2 (1.0–23.6) mm. During single PIBHs with a median duration of 7.1 (2.0–11.1) minutes, the median diaphragm cranial drift velocity was 3.0 (0.4–6.5) mm/minute. For PEBH, the median duration was 5.8 (1.8–10.2) minutes with 4.4 (1.8–15.1) mm/minute diaphragm drift velocity. Conclusions: Regularized breathing at a frequency of 22 brpm resulted in significantly smaller diaphragm motion amplitudes compared to free breathing. This would enable smaller treatment volumes in radiotherapy. Furthermore, prolonged breath-holding from inhalation and exhalation with median durations of six to seven minutes are feasible. Trial registration: Medical Ethics Committee protocol NL.64693.018.18.
- 21 May 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-11
Open AccessQuantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy
Background: Due to respiratory motion, accurate radiotherapy delivery to thoracic and abdominal tumors is challenging. We aimed to quantify the ability of mechanical ventilation to reduce respiratory motion, by measuring diaphragm motion magnitudes in the same volunteers during free breathing (FB), mechanically regularized breathing (RB) at 22 breaths per minute (brpm), variation in mean diaphragm position across multiple deep inspiration breath-holds (DIBH) and diaphragm drift during single prolonged breath-holds (PBH) in two MRI sessions. Methods: In two sessions, MRIs were acquired from fifteen healthy volunteers who were trained to be mechanically ventilated non-invasively We measured diaphragm motion amplitudes during FB and RB, the inter-quartile range (IQR) of the variation in average diaphragm position from one measurement over five consecutive DIBHs, and diaphragm cranial drift velocities during single PBHs from inhalation (PIBH) and exhalation (PEBH) breath-holds. Results: RB significantly reduced the respiratory motion amplitude by 39%, from median (range) 20.9 (10.6–41.9) mm during FB to 12.8 (6.2–23.8) mm. The median IQR for variation in average diaphragm position over multiple DIBHs was 4.2 (1.0–23.6) mm. During single PIBHs with a median duration of 7.1 (2.0–11.1) minutes, the median diaphragm cranial drift velocity was 3.0 (0.4–6.5) mm/minute. For PEBH, the median duration was 5.8 (1.8–10.2) minutes with 4.4 (1.8–15.1) mm/minute diaphragm drift velocity. Conclusions: Regularized breathing at a frequency of 22 brpm resulted in significantly smaller diaphragm motion amplitudes compared to free breathing. This would enable smaller treatment volumes in radiotherapy. Furthermore, prolonged breath-holding from inhalation and exhalation with median durations of six to seven minutes are feasible. Trial registration: Medical Ethics Committee protocol NL.64693.018.18.
- Open Access
- 2 June 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1111) , 20200191
Defining short and prolonged breath-holds
- 2 June 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1111) , 20200191
Open AccessDefining short and prolonged breath-holds