Rajesh Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rajesh Gupta has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Alok Agrawal
Delhi Transco Limited New Delhi India
4 shared publications- Chandra Sekhar Nalamati
Electrical Engineering Department, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India
4 shared publications - Venkitusamy Karthikeyan
Department of Electrical Engineering National Institute of Technology Calicut India
4 shared publications - Mayank Kumar
Delhi Technological University
3 shared publications - Paulson Samuel
MNNIT Allahabad
3 shared publications - Satish Kumar Gudey
Department of Electrical and Electronics Engineering, Gayatri Vidya Parishad College of Engineering (Autonomous), Visakhapatnam, India
3 shared publications
Latest Publications
- 21 October 2026
- Published by Wiley in Energy Storage
- Vol. 8 (8) , e70556
Solar Photovoltaic Based Modular Electric Vehicle Battery Charging Using Interleaved Boost and Phase‐Shifted Full‐Bridge Converters
This paper proposes direct charging of lithium‐ion batteries in electric vehicles (EVs) using standalone solar photovoltaic (PV) systems at distributed charging stations. A PV plant can be operated in an adaptive optimal mode to dynamically regulate its output power to match the aggregate charging power drawn by multiple lithium‐ion batteries, as reflected in the DC‐link voltage. To stabilize the DC‐link voltage and balance power between PV generation and battery load, a master–slave control strategy is used. In this setup, the DC‐link voltage controller acts as the master, generating a corrective duty cycle to reduce voltage changes. The MPPT (Maximum Power Point Tracking) controller, acting as the slave, provides the base duty cycle to extract the maximum power possible from the PV array. The resulting composite duty ratio drives a multiple‐phase interleaved boost DC–DC converter, improving power conversion efficiency and reducing input current ripple. A distributed phase‐shifted full‐bridge converter (PSFBC) is used to charge the batteries following the constant current–constant voltage (CC–CV) method. The proposed architecture is implemented using a modular three‐leg inverter, which is scalable and allows integration of higher‐rated PV arrays and additional battery charging channels without requiring any major modification in the control strategy, owing to the flexibility of the master–slave coordination mechanism. A multiple‐modular boost‐PSFB converter using four three‐phase inverter modules has been used for implementing the four‐phase IBC‐PSFB converter for 10.44 kW solar PV to charge four 72 V, 100 Ah Li‐ion batteries through MATLAB Simulink software. The control algorithm is also validated in real‐time using Typhoon‐HIL in virtual HIL mode for implementing a two‐phase IBC‐PSFB converter, based on a practical setup comprising a 2.2 kW solar PV system and two 72 V, 26 Ah Li‐ion batteries.
- 21 October 2026
- Published by Wiley in Energy Storage
- Vol. 8 (8) , e70556
Solar Photovoltaic Based Modular Electric Vehicle Battery Charging Using Interleaved Boost and Phase‐Shifted Full‐Bridge Converters
This paper proposes direct charging of lithium‐ion batteries in electric vehicles (EVs) using standalone solar photovoltaic (PV) systems at distributed charging stations. A PV plant can be operated in an adaptive optimal mode to dynamically regulate its output power to match the aggregate charging power drawn by multiple lithium‐ion batteries, as reflected in the DC‐link voltage. To stabilize the DC‐link voltage and balance power between PV generation and battery load, a master–slave control strategy is used. In this setup, the DC‐link voltage controller acts as the master, generating a corrective duty cycle to reduce voltage changes. The MPPT (Maximum Power Point Tracking) controller, acting as the slave, provides the base duty cycle to extract the maximum power possible from the PV array. The resulting composite duty ratio drives a multiple‐phase interleaved boost DC–DC converter, improving power conversion efficiency and reducing input current ripple. A distributed phase‐shifted full‐bridge converter (PSFBC) is used to charge the batteries following the constant current–constant voltage (CC–CV) method. The proposed architecture is implemented using a modular three‐leg inverter, which is scalable and allows integration of higher‐rated PV arrays and additional battery charging channels without requiring any major modification in the control strategy, owing to the flexibility of the master–slave coordination mechanism. A multiple‐modular boost‐PSFB converter using four three‐phase inverter modules has been used for implementing the four‐phase IBC‐PSFB converter for 10.44 kW solar PV to charge four 72 V, 100 Ah Li‐ion batteries through MATLAB Simulink software. The control algorithm is also validated in real‐time using Typhoon‐HIL in virtual HIL mode for implementing a two‐phase IBC‐PSFB converter, based on a practical setup comprising a 2.2 kW solar PV system and two 72 V, 26 Ah Li‐ion batteries.
- Open Access
- 4 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Towards Diverse and Coherent Augmentation for Time-Series Forecasting
Time-series data augmentation mitigates the issue of insufficient training data for deep learning models. Yet, existing augmentation methods are mainly designed for classification, where class labels can be preserved even if augmentation alters the temporal dynamics. We note that augmentation designed for forecasting requires diversity as well as coherence with the original temporal dynamics. As time-series data generated by real-life physical processes exhibit characteristics in both the time and frequency domains, we propose to combine Spectral and Time Augmentation (STAug) for generating more diverse and coherent samples. Specifically, in the frequency domain, we use the Empirical Mode Decomposition to decompose a time series and reassemble the subcomponents with random weights. This way, we generate diverse samples while being coherent with the original temporal relationships as they contain the same set of base components. In the time domain, we adapt a mix-up strategy that generates diverse as well as linearly in-between coherent samples. Experiments on five real-world time-series datasets demonstrate that STAug outperforms the base models without data augmentation as well as state-of-the-art augmentation methods.
- 4 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Open AccessTowards Diverse and Coherent Augmentation for Time-Series Forecasting
Time-series data augmentation mitigates the issue of insufficient training data for deep learning models. Yet, existing augmentation methods are mainly designed for classification, where class labels can be preserved even if augmentation alters the temporal dynamics. We note that augmentation designed for forecasting requires diversity as well as coherence with the original temporal dynamics. As time-series data generated by real-life physical processes exhibit characteristics in both the time and frequency domains, we propose to combine Spectral and Time Augmentation (STAug) for generating more diverse and coherent samples. Specifically, in the frequency domain, we use the Empirical Mode Decomposition to decompose a time series and reassemble the subcomponents with random weights. This way, we generate diverse samples while being coherent with the original temporal relationships as they contain the same set of base components. In the time domain, we adapt a mix-up strategy that generates diverse as well as linearly in-between coherent samples. Experiments on five real-world time-series datasets demonstrate that STAug outperforms the base models without data augmentation as well as state-of-the-art augmentation methods.
- 17 May 2023
- Published by Springer Nature
- p. 145-156
Selective Harmonic Compensation in Active Power Filter Using Nonlinear Predictive Current Control Method
- 17 May 2023
- Published by Springer Nature
- p. 145-156
Selective Harmonic Compensation in Active Power Filter Using Nonlinear Predictive Current Control Method
- Open Access
- 1 October 2022
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 11 (5) , 2500-2509
Bridgeless single stage AC/DC converter with power factor correction
This research paper proposes a novel bridgeless single-stage isolated converter with power factor correction and load voltage control. The proposed converter reduces the input diode bridge requirement with reduced passive components and provides a unidirectional flow of power to the load. The single-stage design reduces the use of an electrolytic capacitor, which improves reliability and reduces the size of the converter. The proposed control method is based on a single proportional integral (PI) controller to achieve both power factor correction and input current control. The proposed bridgeless converter is suitable for electric vehicle (EV) charging. A simulation study is performed on the MATLAB/Simulink to verify the effectiveness of the proposed converter. The converter is implemented in the laboratory to obtain the experimental results using typhoon hardware in the loop (HIL) based real time simulator.
- 1 October 2022
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 11 (5) , 2500-2509
Open AccessBridgeless single stage AC/DC converter with power factor correction
This research paper proposes a novel bridgeless single-stage isolated converter with power factor correction and load voltage control. The proposed converter reduces the input diode bridge requirement with reduced passive components and provides a unidirectional flow of power to the load. The single-stage design reduces the use of an electrolytic capacitor, which improves reliability and reduces the size of the converter. The proposed control method is based on a single proportional integral (PI) controller to achieve both power factor correction and input current control. The proposed bridgeless converter is suitable for electric vehicle (EV) charging. A simulation study is performed on the MATLAB/Simulink to verify the effectiveness of the proposed converter. The converter is implemented in the laboratory to obtain the experimental results using typhoon hardware in the loop (HIL) based real time simulator.
- 9 June 2022
- Published by Taylor & Francis in IETE Technical Review
- Vol. 40 (2) , 220-233
Formulation of Switching Instant for Improved Dynamic Performance in the Predictive Current Control Technique
This paper analyzes the dynamic performance of the predictive current control (PCC) scheme for a single-phase grid-connected (SPGC) voltage source inverter (VSI). VSI performance and its operating conditions, such as steady-state and dynamic-state, have been analyzed. Conventionally a linear current error (eL)-based control technique is used, which has poorer current tracking during dynamic conditions. In this paper, a novel control technique has been proposed that utilizes a non-linear current error (eNL) based on the instantaneous grid voltage and DC-link voltage to calculate the switching instant, which gives better tracking performance during the dynamic condition. A mathematical model of digitally controlled PCC predicts the load current for all switching states of the inverter. Calculations of these predicted current values are done by using a cost function. The switching state with minimum cost function is selected and applied to the inverter for improved dynamic performance. The effect of parameter variations, such as load current, DC-link voltage etc., has been investigated. The performance of the proposed method has been tested at different sampling frequencies. The effectiveness of the PCC technique is simulated in specialized power electronics software and experimentally validated by a proto-type model using an FPGA controller.
- 9 June 2022
- Published by Taylor & Francis in IETE Technical Review
- Vol. 40 (2) , 220-233
Formulation of Switching Instant for Improved Dynamic Performance in the Predictive Current Control Technique
This paper analyzes the dynamic performance of the predictive current control (PCC) scheme for a single-phase grid-connected (SPGC) voltage source inverter (VSI). VSI performance and its operating conditions, such as steady-state and dynamic-state, have been analyzed. Conventionally a linear current error (eL)-based control technique is used, which has poorer current tracking during dynamic conditions. In this paper, a novel control technique has been proposed that utilizes a non-linear current error (eNL) based on the instantaneous grid voltage and DC-link voltage to calculate the switching instant, which gives better tracking performance during the dynamic condition. A mathematical model of digitally controlled PCC predicts the load current for all switching states of the inverter. Calculations of these predicted current values are done by using a cost function. The switching state with minimum cost function is selected and applied to the inverter for improved dynamic performance. The effect of parameter variations, such as load current, DC-link voltage etc., has been investigated. The performance of the proposed method has been tested at different sampling frequencies. The effectiveness of the PCC technique is simulated in specialized power electronics software and experimentally validated by a proto-type model using an FPGA controller.
- 27 May 2022
- Published by Springer Nature
- p. 253-270
Study on Classifications and Modeling of Loads in Low Voltage Distribution System
- 27 May 2022
- Published by Springer Nature
- p. 253-270
Study on Classifications and Modeling of Loads in Low Voltage Distribution System
- 18 February 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (11) , 8502-8510
Switching Frequency Formulation for Predictive Current Control in Grid-Connected VSI
In this paper, a switching frequency has been formulated for grid-connected voltage source inverter (VSI) operated using the Continuous Control Set-Predictive Current Control (CCS-PCC) technique. An instantaneous expression of switching frequency has been derived for the VSI operated using the predictive current control technique. The effect of sampling frequency has been analyzed on the switching frequency of the converter operation. The effect of sampling time has a direct impact on the switching frequency as the cost function of the PCC depends on the sampling frequency. The analysis provides a generalized mathematical expression of switching frequency for the VSI operating in current control mode using the predictive current control method. With the help of this generalized expression, the maximum switching frequency and minimum load current error have been obtained. Simulation has been performed for verification of the analytical results through a Typhoon HIL-402 kit for real-time simulation and experimental validation.
- 18 February 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (11) , 8502-8510
Switching Frequency Formulation for Predictive Current Control in Grid-Connected VSI
In this paper, a switching frequency has been formulated for grid-connected voltage source inverter (VSI) operated using the Continuous Control Set-Predictive Current Control (CCS-PCC) technique. An instantaneous expression of switching frequency has been derived for the VSI operated using the predictive current control technique. The effect of sampling frequency has been analyzed on the switching frequency of the converter operation. The effect of sampling time has a direct impact on the switching frequency as the cost function of the PCC depends on the sampling frequency. The analysis provides a generalized mathematical expression of switching frequency for the VSI operating in current control mode using the predictive current control method. With the help of this generalized expression, the maximum switching frequency and minimum load current error have been obtained. Simulation has been performed for verification of the analytical results through a Typhoon HIL-402 kit for real-time simulation and experimental validation.
- 10 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 16 (3) , 4607-4618
Coordinated Control of Hybrid DERs Enabled Grid-Interactive Residential PCM With Hybrid Bus Layout
This article proposes a multi-terminal grid interactive power conditioning module (PCM) for integration of hybrid distributed energy resources (DERs) within single phase residential premises, along with the Energy Storage Stacks (ESSs). The PCM also features hybrid bus layouts with medium-low voltage dc (MVdc) and low voltage dc (LVdc), for dc load integrations, and ac bus layout for single phase ac loads. The bi-directional MVdc and LVdc bus facilitate the effective power management and bus voltage support. It operates in all grid feeding, forming and supportive modes. The ESSs includes battery for system energy management and the supercapacitor for dc bus stabilization during transient conditions. The coordinated control of the PCM is capable of interfacing multiple DERs, dc/ac loads, and ESS. The controllers in the PCM are self-adaptive to the frequent islanding situations and ensure the system stability with minimum use of sensory feedbacks. The PCM has loop type dc bus feeder to make residential system operative during transient/faulty conditions. Simulation results verify the feasibility of the proposed system in all active and passive grid feeding; and grid forming modes and experimental setup is used to test the performance of the proposed PCM control through a single microcontroller.
- 10 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 16 (3) , 4607-4618
Coordinated Control of Hybrid DERs Enabled Grid-Interactive Residential PCM With Hybrid Bus Layout
This article proposes a multi-terminal grid interactive power conditioning module (PCM) for integration of hybrid distributed energy resources (DERs) within single phase residential premises, along with the Energy Storage Stacks (ESSs). The PCM also features hybrid bus layouts with medium-low voltage dc (MVdc) and low voltage dc (LVdc), for dc load integrations, and ac bus layout for single phase ac loads. The bi-directional MVdc and LVdc bus facilitate the effective power management and bus voltage support. It operates in all grid feeding, forming and supportive modes. The ESSs includes battery for system energy management and the supercapacitor for dc bus stabilization during transient conditions. The coordinated control of the PCM is capable of interfacing multiple DERs, dc/ac loads, and ESS. The controllers in the PCM are self-adaptive to the frequent islanding situations and ensure the system stability with minimum use of sensory feedbacks. The PCM has loop type dc bus feeder to make residential system operative during transient/faulty conditions. Simulation results verify the feasibility of the proposed system in all active and passive grid feeding; and grid forming modes and experimental setup is used to test the performance of the proposed PCM control through a single microcontroller.
- 1 January 2022
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 15 (6) , 430-443
Three Port Isolated AC/DC Converter with Power Factor Correction
Background Conventionally, a two-stage conversion is required for providing isolated DC output. Objectives This paper aimed at proposing a converter comprising three ports with isolated output and higher output power and voltage levels, and to study its switching operations. Methods The converter has two input ports that connect an AC source and the solar PV source. The third port acts as an output port to supply the desired load. The proposed topology can supply the high dc output voltage with isolation while maintaining a high input power factor. A single-stage conversion is used in the converter, which helps in reducing the switching devices and the bulky electrolytic capacitor while integrating a solar PV. As there is no intermediate stage of conversion in the proposed converter, it is well suited for the standalone PV-based applications, such as remote light electric vehicle chargers. Results The simulation verification of the proposed converter has been obtained in the MATLAB/SIMULINK, and the experimental results have been obtained via a control algorithm implemented using FPGA-based Typhoon HIL 402, which demonstrated the control method and working of topology to be effective. Conclusion The desirable operation of the converter has been achieved.
- 1 January 2022
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 15 (6) , 430-443
Three Port Isolated AC/DC Converter with Power Factor Correction
Background Conventionally, a two-stage conversion is required for providing isolated DC output. Objectives This paper aimed at proposing a converter comprising three ports with isolated output and higher output power and voltage levels, and to study its switching operations. Methods The converter has two input ports that connect an AC source and the solar PV source. The third port acts as an output port to supply the desired load. The proposed topology can supply the high dc output voltage with isolation while maintaining a high input power factor. A single-stage conversion is used in the converter, which helps in reducing the switching devices and the bulky electrolytic capacitor while integrating a solar PV. As there is no intermediate stage of conversion in the proposed converter, it is well suited for the standalone PV-based applications, such as remote light electric vehicle chargers. Results The simulation verification of the proposed converter has been obtained in the MATLAB/SIMULINK, and the experimental results have been obtained via a control algorithm implemented using FPGA-based Typhoon HIL 402, which demonstrated the control method and working of topology to be effective. Conclusion The desirable operation of the converter has been achieved.