ZDZhitao Dai

Zhitao Dai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhitao Dai has a total of 151 co-authors. Here are the top co-authors by number of shared publications:

  • Cheng Chen

    Department of Radiation and Medical Oncology Zhongnan Hospital of Wuhan University Wuhan China

    5 shared publications
  • Suyan Bi

    Post-Doctoral Research Center, Yuebei People's Hospital, Southern Medical University, Shaoguan, Guangdong Province, China

    5 shared publications
  • Tingting Cao

    Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China

    5 shared publications
  • Meiling Xu

    National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China

    4 shared publications
  • Changyou Zhong

    Cancer Center, Meizhou People’s Hospital (Huangtang Hospital), Meizhou, China

    3 shared publications
  • Huanfan Su

    Department of Medical Imaging, Jiangxi Medical College, 334000, Shangrao, Jiangxi, China

    3 shared publications

Latest Publications

  • Open Access

    A concentration-source-driven and GPU-accelerated standalone radiochemistry framework for continuous water radiolysis and pulse-structure simulation

    by Shuai Hu, Jialin Huang, Zhizhen Wei, Can Mo, Yuanjie Bi, Meiyu Si, Kilian-Simon Baumann, Pengyi Ji, Xin Ge, Yuanchun Ye, et al.

    Objective. Radiochemistry modeling plays a critical role in understanding the evolution of radiolytic species and their potential role in radiation-induced biological responses. Conventional Monte Carlo approaches can resolve early non-homogeneous chemistry, but their direct use in long-time, large-volume, or multi-pulse chemical-stage simulations is limited by high computational cost and boundary-condition constraints. This study aims to develop a GPU-accelerated, standalone radiochemistry framework driven by species concentration distribution sources (SCDS), enabling continuous water radiolysis modeling from the early non-homogeneous stage to the homogeneous stage and supporting flexible construction of pulse structures. Approach. SCDS were generated from Geant4-DNA simulations at t start = 5   ns and used as source terms for subsequent reaction–diffusion calculations. A concentration-dependent correction (CDC), fitted as a function of the local reactant concentration product, was incorporated to account for non-homogeneous reaction kinetics not captured by classical mass-action reaction–diffusion equations (RDEs). A 1   nm minimum reaction unit and a dual-grid GPU implementation were used to preserve simulation accuracy while ensuring efficiency. The model was benchmarked against Geant4-DNA for 50 and 500 MeV protons, 100 MeV u − 1 4 He ions and 200 MeV u − 1 12 C ions, and was used to simulate inter-track effects and macro-pulse irradiation. Main results. The fitted CDC functions captured the concentration-dependent kinetic discrepancy with R 2 > 0.99 for representative reactions and became negligible in the low-concentration regime, thereby recovering classical RDE kinetics. Using a single set of CDC functions, RDEs-extended reproduced Geant4-DNA time-dependent G -values for 50 and 500 MeV protons, 100 MeV u − 1 4 He ions and 200 MeV u − 1 12 C ions, with most species showing deviations within ± 5 % at 1   μ s . The GPU-accelerated implementation reduced computation time by 193.74 – 1191.37 × for the 1   μ s benchmark cases. Pulse-structure simulations showed stronger depletion of e aq − and OH − under shorter source separation and higher dose per pulse, indicating enhanced radical overlap and recombination. Significance. This work establishes an SCDS-driven, GPU-accelerated radiochemistry framework for continuous chemical-stage simulation of water radiolysis. The framework improves computational efficiency, reduces dependence on incident-particle tracking and boundary conditions, and supports pulse-structure simulations for studying radiolytic species evolution. The proposed model provides an efficient and extensible tool for simulating pulsed radiochemistry in realistic radiotherapy scenarios.

  • Open Access

    Implementation and preliminary evaluation of a practical digital workflow for routine laser‐radiation field coincidence quality assurance on the CyberKnife M6

    by Linzheng Hu, Yongkang Zhao, Chunling Zheng, Jiajun Cai, Yajun Jia, Yi Tao, Yikun Liu, Yin Zhang, Zhitao Dai

    Purpose: To implement and preliminarily evaluate a practical digital acquisition‐and‐analysis workflow for routine laser‐radiation field coincidence quality assurance (QA) on the CyberKnife M6 by integrating multileaf collimator (MLC) QA tool‐based laser reference definition, QA StereoChecker (QASC)‐based external digital image acquisition, and automated analysis with CKQA, an in‐house CyberKnife QA software, and to compare this workflow with clinically realistic film‐based alternatives. Methods: Methods a and b were film‐based measurements performed at the perch position. Method a used manual laser marking on film, whereas method b used the central metal marker of the MLC QA tool to define the laser reference. Method c used QASC as an external digital image‐acquisition platform in combination with the MLC QA tool, and method d used film on the same QASC‐based setup as a control. All methods were tested with 10 fixed collimators (5–40 mm). Images were analyzed using ImageJ and CKQA. Mean deviation, standard deviation, root mean square error (RMSE), and pairwise two‐sided exact Wilcoxon signed‐rank tests were used for exploratory comparisons. Results: All evaluated workflows achieved submillimeter mean deviations. Across both analysis approaches, the mean deviation ranked consistently in descending order: method a > method b > method d > method c. Under the present experimental conditions, method c yielded the lowest mean deviation and RMSE (0.116 mm and 0.155 mm with CKQA), whereas method a showed the largest deviations. Dataset‐level exact Wilcoxon signed‐rank tests showed that several comparisons involving method a were statistically significant, but statistically significant differences were not uniform across both ImageJ‐ and CKQA‐based comparisons. For comparisons between analysis methods within each workflow, CKQA and ImageJ were not significantly different for methods a and b, whereas CKQA yielded significantly lower deviations than ImageJ for methods c and d ( p < 0.05). Conclusions: Laser‐radiation field coincidence testing is an established CyberKnife QA procedure. The present study implemented and preliminarily evaluated a practical digital acquisition‐and‐analysis workflow for this routine task. The workflow combining MLC QA tool‐based laser reference definition, QASC‐based external digital image acquisition, and automated CKQA analysis provided a standardized and less operator‐dependent procedure under the present experimental conditions. Its main value lies in reducing manual marking, film handling, scanning, and subjective image‐analysis steps rather than in introducing a new physical measurement principle. In centers where QASC is not available, the film‐based workflow using the MLC QA tool (method b) may serve as a practical alternative.

  • Open Access

    Dosimetric comparison of pipe-joint versus conventional VMAT for lattice radiotherapy in bulky tumors: a retrospective planning study

    by Changyou Zhong, Meiling Xu, Shengzhen Dong, Cuiting Xu, Zhendong Jiang, Haidong Yu, Zhitao Dai

  • Open Access

    Global Landscape of Registered Clinical Studies of Spatially Fractionated Radiotherapy: Evidence Gaps and Research Priorities

    by Jiaomei Zhou, Suyan Bi, Zhitao Dai

    Background: Clinical investigation of spatially fractionated radiotherapy (SFRT) is expanding, but the extent to which registered interventions are defined sufficiently for replication remains unclear. We characterised the global portfolio of registered SFRT studies, assessed its evidence maturity, and identified priorities for future clinical research. Methods: We searched the World Health Organization International Clinical Trials Registry Platform (WHO ICTRP) through 14 July 2026 as the sole global identification source. Candidate records were verified against official registry records or retained official exports, cross registry duplicates were resolved at the protocol level, and independent studies were summarised by temporal, geographic, clinical, technical, and design characteristics. Reporting completeness was assessed using a nine-domain framework and parameter-level classifications. Results: We identified 59 independent studies. Fifty (84.7%) began or were scheduled to begin in 2023–2026, with 2026 representing a partial year; 55 (93.2%) were interventional and 43 (72.9%) were non-comparative. Twenty-four studies (40.7%) evaluated SFRT alone, whereas 35 (59.3%) incorporated at least one additional protocol-defined treatment modality. Among these 35 multimodal studies, sequencing was explicitly reported in 24 (68.6%) and quantitative inter-treatment timing in 10 (28.6%). SFRT dose and fractionation were specifically or quantitatively reported in 24 studies (40.7%). All studies registered primary endpoints, but none had posted primary-registry summary results containing observed clinical endpoint values. Conclusions: The registered SFRT portfolio is expanding rapidly but remains early-stage, heterogeneous, and predominantly signal-generating. Multimodality treatment is common, whereas timing and intervention-defining technical details are incompletely reported. Future disease-specific, preferably multicentre trials should incorporate reproducible intervention definitions and transparent outcome reporting.

  • Open Access

    R3Net: Recursive Residual Refinement Network Architecture for Decoder‐Free Medical Image Segmentation

    by Jing Huang, Yongkang Zhao, Yuhan Li, Zhitao Dai, Cheng Chen, Qiying Lai

    Background: Medical image segmentation methods based on encoder–decoder architectures often achieve high accuracy but typically require substantial computational resources and contain redundant parameters. Purpose: This study aims to develop an efficient decoder‐free segmentation framework that maintains competitive performance by strengthening the encoding process. Methods: We propose R3Net, an encoder‐only segmentation architecture based on a recursive residual refinement (R3) mechanism. By recursively reusing encoder stages and progressively fusing multiscale features through residual pathways, R3Net reconstructs high‐resolution features without requiring a dedicated decoder. Results: Experiments on three medical imaging modalities—cardiac MRI (Automated Cardiac Diagnosis Challenge), abdominal CT (Synapse), and thyroid ultrasound (Thyroid Nodule Multimodal Learning)—demonstrate that R3Net achieves segmentation performance comparable to representative encoder–decoder models while reducing the number of model parameters and computational complexity. Conclusion: R3Net provides an effective decoder‐free alternative for medical image segmentation, suggesting that competitive dense prediction can be achieved through recursive refinement within the encoder.

  • Open Access

    Enhanced 3D-GRID radiotherapy on helical tomotherapy via personalized geometric optimization: A comparative study with IMRT and VMAT

    by Wu Weiwei, Li Jinwei, Yin Hui, Liu Zhiwei, Wang Chuangao, Dai Zhitao

  • Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation

    by Jialin Huang, Shuai Hu, Can Mo, Yuanchun Ye, Tengda Zhang, Zhitao Dai, Yongsheng Huang, Yuan Chen, Jinfen Zheng, Jinghui Wang, et al.

    Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.

  • Open Access

    Spiral volumetric modulated arc therapy enhances peak-to-valley dose contrast for 3D-GRID radiotherapy compared to VMAT and tomotherapy

    by Wu Weiwei, Zhiwei Liu, Li Weizhi, Li Zhenghuan, Dai Zhitao, Wang Chuangao

    Three-dimensional GRID radiotherapy for bulky tumours requires high peak dose while effectively preserving a low-dose intratumoural valley, but this remains challenging with current linac-based techniques. Spiral volumetric modulated arc therapy (sVMAT) is an integrated delivery technique with synchronized longitudinal couch motion and gantry rotation that generates a spiral/helical beam trajectory, combining key advantages of volumetric modulated arc therapy (VMAT) and helical tomotherapy (TOMO). This study evaluated the dosimetric feasibility of sVMAT for single-fraction 3D-GRID radiotherapy and compared it with conventional VMAT and TOMO. Twenty patients with bulky tumours were retrospectively replanned. Cylindrical GRID peak structures with a diameter of 1.0 cm were generated within the GTV using a uniform 0.5-1.0 cm retraction from the GTV boundary and a 1.0 cm clearance from adjacent OARs; cylinders violating these spatial constraints were automatically truncated or excised. A single fraction of 18 Gy was prescribed to the virtual GRID peaks only, while dose to the intervening non-peak GTV valley was minimized as low as reasonably achievable rather than intentionally prescribed. For each patient, three plans were individually generated: VMAT, TOMO and sVMAT. sVMAT plans were created on the NeuRT Aurora platform using DeepPlan with synchronized gantry rotation and bidirectional couch translation. Dosimetric comparisons included gradient index (GI), peak-to-valley dose ratio using two definitions (PVDR1=D10%/D90% and PVDR2=D2%/D50%), and OAR sparing. Delivery efficiency was evaluated using monitor units (MU) and beam-on time. sVMAT showed the strongest overall dosimetric performance. sVMAT achieved the steepest dose gradient, with a lower GI than VMAT and TOMO (8.86 ± 2.00 vs. 14.93 ± 5.18 and 15.07 ± 5.97; both p < 0.001). PVDR1 was numerically highest with sVMAT (5.137 ± 2.325), compared with VMAT (4.692 ± 2.213) and TOMO (3.963 ± 2.288). PVDR2 was also highest with sVMAT (2.975 ± 0.470 vs. 2.604 ± 0.464 and 2.575 ± 0.567, respectively). All three techniques met single-fraction OAR constraints without clinically meaningful differences. Both MU and beam-on time for sVMAT were intermediate between VMAT and TOMO, with VMAT showing the lowest values and TOMO the highest; mean beam-on time was 1181 ± 512 s for sVMAT, versus 307 ± 30 s for VMAT and 1896 ± 1224 s for TOMO. For cylindrical 3D-GRID radiotherapy, sVMAT provided superior dose confinement and enhanced peak-to-valley dose contrast, while maintaining OAR sparing comparable to VMAT and TOMO. These findings support sVMAT as a promising platform for modern high-contrast 3D-GRID radiotherapy.

  • Open Access

    Spatially fractionated radiation therapy (SFRT): a scoping review of dosimetric and biological evidence supporting a valley dose–driven translational framework

    by Suyan Bi, Changyou Zhong, Ying Long, Zhongqing Huang, Zhitao Dai

    Background: Spatially fractionated radiation therapy (SFRT)—mainly including GRID, LATTICE, minibeam, and microbeam—widens the therapeutic window for bulky or radioresistant tumors. Yet clinical translation faces two persistent hurdles: technical heterogeneity across modalities and a lack of evidence-based, tumor-specific dose prescription guidelines. Methods: This scoping review maps the SFRT evidence landscape from 2005 to 2025. Following PRISMA-ScR guidelines, we synthesized 60 studies (preclinical, clinical, technical) and identified valley dose (D valley ) as a consistently reported strong candidate predictor of the therapeutic window. Results: Based on this pattern, we outline an evidence-informed organizational framework. Synthesizing the extracted data, we delineate a tripartite structure that emerged from the literature: (1) a tumor-and modality-specific dosimetric decision frame work (Level 1) capturing histology-dependent D valley benchmarks (e.g., ≥ 2 Gy for cervical LATTICE, ~ 10 Gy for brain proton minibeam) with PVDR guidance; (2) a Mechanism- Biomarker-Outcome (MBO) chain (Level 2) linking spatial dose gradients to quantifiable cascades—vascular normalization (DCE-MRI Ktrans), immune preservation (CD8⁺ density), and bystander signaling (HMGB1, TNF-α, ROS); (3) an exploratory surrogate marker model (Level 3) identifying early short-term metrics (6-month metabolic response ≥ 50% SUVmax reduction, cytokine dynamics) as candidate correlates of long-term local control. Conclusion: By mapping the shift from peak-centric ablation to a valley-dose-driven approach reflected in the literature, this review provides a structured, evidence-informed scaffold for future clinical trial design and technical harmonization. The framework presented is intended as a hypothesis-generating tool to inform the standardized implementation of SFRT in precision radiation oncology.