MLMohd Juzaila Abd Latif

Mohd Juzaila Abd Latif

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohd Juzaila Abd Latif has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and analysis of a portal frame test rig for vertical load testing of goalpost pipeline support

    by Tsaqif Al Farrel Ghazali, Mohd Shukri Yob, Mohd Juzaila Abd Latif, Ojo Kurdi, Fudhail Abdul Munir

    Pipe support is a crucial infrastructure in the oil and gas industry, requiring robust designs to withstand various loads and maintain operational stability. While numerical analysis is commonly used to assess the interaction between pipelines and supports, experimental testing remains essential for validation. However, field testing is often costly and difficult due to safety constraints. To overcome this, a reliable test rig with minimal deflection is needed to ensure accurate experimental results. This study uses finite element analysis (FEA) to evaluate both a goalpost pipeline support and a newly developed portal frame test rig. The test rig was analyzed under two conditions: the failure load of the goalpost support and an amplified load with a factor of 2.5 to simulate unexpected scenarios. Results show the test rig can safely withstand loads up to 40 kN, meeting the EN 1990 safety factor requirement of 1.5. Furthermore, critical components remained within the deflection limit specified by the British Constructional Steelwork Association (BCSA), which is under L/1,000 of the beam length. These results confirm the structural integrity and suitability of the portal frame test rig for accurate testing of the goalpost pipeline support structure.

  • Open Access

    Test rig development for load test of pipe saddle support

    by Muhammad Arif Rayhan, Mohd Shukri Yob, Mohd Juzaila Abd Latif, Ojo Kurdi, Fudhail Abdul Munir

    Pipe saddle support is a structure commonly used to support horizontal steel pipe. It prevents direct contact between the pipe and the support. Pipe saddle support can experience displacement due to pipe movement and insufficient stress analysis. Given these concerns, conducting a load test is essential to determine the stress on pipe saddle supports. However, a universal testing machine (UTM) is not suitable for this purpose due to the size limitation. Therefore, this study proposed a test rig setup for the pipe saddle support load test. The test rig consists of a portal frame secured by an underground locking system featuring a strong floor. Additionally, an actual pipe is utilized to replicate actual loading conditions on the pipe saddle support. The applied load is measured using a load cell, with a custom-designed bracket to ensure precise load transfer. Finally, the pipe saddle support specimen is bolted to a base support to maintain stability during the load test. Stress analysis using finite element analysis (FEA) demonstrated that the test rig is suitable for conducting load tests on the specimens with a maximum force of 80 kN. FEA confirmed that the test rig operates within a safety factor of 1.3.

  • Alteration of Biomechanical Properties in Early-Stage Osteoarthritis: A Study on Elastic Modulus and Permeability of Articular Cartilage

    by Syaidatul Syakirah Salehuddin, Mohd Juzaila Abd Latif, Mohamad Shukri Zakaria, Muhamad Noor Harun, Munirah Sha’BAn


  • Open Access

    A rigorous examination of electromyography forearm muscle response in grasping and swinging scenarios

    by Wan Mohd Bukhari Wan Daud, Mohammad Osman Tokhi, Rubita Sudirman, Mohd Juzaila Abd Latif, Norafizah Abas, Tole Sutikno

    This study examines the use of electromyography (EMG) in analyzing forearm muscle responses in hand grasping force with swinging motions. We start by establishing the basics of hand grasping force and swinging motions, laying the groundwork for subsequent discussions. The paper critically assesses various EMG techniques, highlighting how they reveal muscle activity during hand grasping in dynamic situations. We explore how swinging motions affect hand grasping force biomechanics, emphasizing the role of EMG in capturing dynamic muscle activity. A thorough examination of methodologies used in EMG studies provides insights into current practices and emerging trends. Practical applications across fields like rehabilitation and robotics underscore the relevance of this research. The study concludes by addressing current challenges and suggesting future research directions. This synthesis provides a straightforward resource for researchers, practitioners, and technologists seeking a deeper understanding of EMG indices in hand-grasping force analysis with swinging action.

  • Open Access

    Thermal Analysis of Micro Plasma Wire Arc Additive Manufacturing Deposition Process

    by Siti Khairiyah Sulaiman, Mohd Rizal Alkahari, Mohd Juzaila Abd Latif, Yupiter Harangan Prasada Manurung, Keval Priapratama Prajadhiana

    Additive manufacturing (AM) is rapidly developing with emerging technology of wire arc additive manufacturing (WAAM) process due to its ability to manufacture large components and high deposition rate. However, WAAM faces mechanical properties problems like porosity, distortion, and strength due to the large heat affected zone (HAZ) from commonly used heat sources such as metal inert gas (MIG) and tungsten inert gas (TIG). Utilization of micro plasma as the heat source should reduce this problem since it has a smaller heat source diameter. Therefore, this study investigates the thermal distribution of micro plasma wire arc additive manufacturing (MPWAAM) by developing a finite element method (FEM) model. This paper focuses on the fabrication of single-layer multitrack deposition and tool path planning of multi-layer multitrack depositions by MPWAAM process. The melt pool size and peak temperature are mainly governed by heat input per unit travel speed of the worktable, with current and voltage being the significant factors. Besides, tool path planning strategy influences the properties and quality of the final product, where parallel tool path design with longer interlayer cooling time minimized part distortion and residual stresses.


  • Effect of printing orientation on structural strength of 3D-printed polylactic acid prosthetic socket using fused deposition modeling

    by Adila Fazliana Che Manan, Mohd Juzaila Abd Latif, Misalini Narasamman, Masjuri Musa, Mohd Nazim Abdul Rahman, Guo Dong Lim, Parathy Rajaandra

    Background: Recent fused deposition modeling (FDM) technology could offer accessible socket fabrication and resolve conventional fabrication issues. However, the printing orientation in FDM affects the structural integrity and reliability. Objective: To examine the effect of printing orientation on the structural strength of 3D-printed sockets using FDM. Study Design: Experimental study of 3D-printed socket at different printing orientations in static and cyclic loadings. Methods: This study scanned residual limbs of 2 transtibial amputees weighing 53 kg (P4) and 125 kg (P6) to create 3D-printed prosthetic sockets using FDM. Ten sockets of a P4 amputee were printed at various orientations from 0° to 90° for a structural static test. In addition, 6 sockets of the P6 amputee were printed at 90° for static and cyclic tests according to ISO 10328. Results: Based on the results, sockets printed at 0° and 90° for the P4 amputee exceeded static ultimate force under condition I according to ISO 10328 standards with 4880 N and 4430 N, respectively. Sockets at 30°, 45°, and 60° failed before the minimum force requirement was reached. Further validation of the 90° printed socket passed the static test in conditions I and II, and the cyclic test in condition II, enduring 3 million cycles without failure. Conclusion: The 0° and 90° printing orientations are recommended for their superior mechanical properties, whereas other orientations may pose safety risks because of insufficient structural strength. These findings could contribute to developing more reliable and durable prosthetic sockets that meet ISO 10328 standards to enhance the quality of life for amputees.


  • Open Access

    Effect of Storage Temperature of Articular Cartilage on Magnetic Resonance Imaging Greyscale and Biomechanical Properties

    by Hashemi Hashim, Mohd Juzaila Abd Latif, Mohammad Shukri Zakaria, Ruzy Haryati Hambali, Hambali Arep, Muhammad Noor Harun, Nguyen Ho Quang, Munirah Sha’ban

    Storage and preservation of articular cartilage are important in experimental studies. Various storage temperatures were used which led to conflicting results on the biomechanical properties of the cartilage. Therefore, this study aimed to examine the effect of storage temperature on the magnetic resonance imaging (MRI) image and biomechanical properties of articular cartilage. The cartilage specimens were extracted from hip bovine joints which were then tested in fresh condition and in a single freeze-thaw cycle at -20°C to observe the effect of the temperature. Low-field MRI was utilized to obtain the images which were processed to determine the greyscale intensity of the cartilage. Subsequently, indentation tests were conducted on the cartilage and the data was integrated with finite element analysis to characterize the biomechanical properties of permeability and elastic modulus. Based on the results, the elastic modulus of the frozen cartilage decreased to 29%, while the permeability increased to 77% compared to the fresh cartilage. Furthermore, a strong positive correlation (r=0.85) was found between MRI image greyscale and permeability, while a negative moderate correlation (r=-0.51) was obtained between MRI image greyscale and elastic modulus. These findings highlighted the significant effect of storage temperature on the MRI image greyscale and biomechanical properties of cartilage.

  • Structural Strength of Transtibial Prosthetic Socket at Different Printing Orientations in Fused Deposition Modelling

    by Adila Fazliana Che Manan, Mohd Juzaila Abd Latif, Misalini Narasamman, Masjuri Musa, Mohd Nazim Abdul Rahman, Lim Guo Dong, Parathy Rajaandra

  • Effects of Storage Temperature on Biomechanical Properties of Articular Cartilage

    by Hashemi Hashim, Mohd Juzaila Abd Latif, Rizwana Seeni Ibramsa, Mohamad Shukri Zakaria, Ruzy Haryati Hambali, Hambali Arep, Muhamad Noor Harun

  • Effect of elastic deformation on lubrication characteristics in different clearances and head size of metallic artificial hip joint

    by Mohd Syafiq Mohd Suri, Ab Aziz Mohd Yusof, Ardiyansyah Syahrom, Mohd Juzaila Abd. Latif, Muhamad Noor Harun

    The issue of lubrication in metallic artificial hip joints is discussed to prevent the two bearing surfaces from contacting each other. This study aims to analyse the characteristics of elastohydrodynamic lubrication (EHL) and investigate the effect of radial clearance and head size on the tribological performance of metallic artificial hip joints under steady-state conditions using the Fluid-Structure-Interaction (FSI) method. The average load in the z-direction and flexion-extension motion around the y-axis were used to represent normal walking. This study demonstrates that the film thickness profile from the validation study aligns with the findings of the previous study. The contour of the fluid pressure in the central contact zone changes with different time steps – the direction of fluid movement corresponds to the solid-fluid reaction. Additionally, the deformation of the cup surfaces contributes to the continuous fluid film that separates the contact surfaces. Furthermore, design parameters also influence EHL performance. It has been discovered that less radial clearance and a larger head size led to an increase in fluid film thickness.