Tae Soo Bae
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tae Soo Bae has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Byeong Chan Cho
Dept. of Convergence Engineering, Jungwon University, Chungbuk, Korea
6 shared publicationsJae Woong Han
Dept. of Medical Device Industry, Jungwon University, Chungbuk, Korea
6 shared publicationsBo Won Jung
Department of Biomedical Engineering, Jungwon University, Chungbuk, Republic of Korea
2 shared publications- Kwon-Hee Kim
Department of Mechanical Engineering, Korea University, 145, Anam-Ro, Seongbuk-gu, Seoul 02841, Korea
2 shared publications - Byoung-Hyun Min
Department of Orthopedic Surgery, School of Medicine, Ajou University, Suwon, Republic of Korea; Institute of Regenerative Medicine, Wake Forest University, NC, USA; Advanced Translational Engineering & Medical Science, Seoul, Republic of Korea
1 shared publication Cheolwoong Ko
Biomedical and Welfare Technology R&BD Group, Korea Institute of Industrial Technology, Chungcheongnam-do, South Korea
1 shared publication
Latest Publications
- 4 September 2026
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 40 (9) , 6947-6952
Biomechanical effects of femoral aspect ratio and tunnel position on ACL graft loading under cyclic knee motion
- 4 September 2026
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 40 (9) , 6947-6952
Biomechanical effects of femoral aspect ratio and tunnel position on ACL graft loading under cyclic knee motion
- 13 July 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (10) , 4317-4329
Are Standard High Tibial Osteotomy Strategies Appropriate for Patients With a Discoid Lateral Meniscus?
- 13 July 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (10) , 4317-4329
Are Standard High Tibial Osteotomy Strategies Appropriate for Patients With a Discoid Lateral Meniscus?
- 1 May 2025
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 26 (10) , 2749-2760
Are Homogeneous Models Still Reliable for Analyzing Implant Bone Resorption?
- 1 May 2025
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 26 (10) , 2749-2760
Are Homogeneous Models Still Reliable for Analyzing Implant Bone Resorption?
- 12 March 2024
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 38 (3) , 1613-1623
Effect of floor and chair sit-to-stand motions on determination of optimal surgical site for anterior cruciate ligament reconstruction surgery
- 12 March 2024
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 38 (3) , 1613-1623
Effect of floor and chair sit-to-stand motions on determination of optimal surgical site for anterior cruciate ligament reconstruction surgery
- 28 August 2023
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 24 (11) , 2083-2098
Effects of Mid- and Low-Frequency Electromyostimulation for Prevention of Sarcopenia on Lower Extremity Muscles
- 28 August 2023
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 24 (11) , 2083-2098
Effects of Mid- and Low-Frequency Electromyostimulation for Prevention of Sarcopenia on Lower Extremity Muscles
- 1 July 2021
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 38 (7) , 521-528
Comparative Study of Gait Stability Using COM-COP Inclination Angle Changes of Elderly
The current method of gait analysis has several limitations for determining gait stability, such as a complicated preparation process, repeated experimental procedures that are time-consuming, and financial burden of experiments. This study investigated whether gait stability could be analyzed using only the COM-COP (Center of Mass-Center of Pressure) inclination angle connecting COM and COP. COM and COP coordinates were obtained from a motion analysis system for a total of 40 elderly and young subjects. The COM-COP inclination angle that changed in real time during level walking was then analyzed to obtain gait stability on each of sagittal and frontal planes using these coordinates. As a result, the gait symmetry index on the sagittal plane did not show a statistically significant difference between young and elderly subjects (First Step, p = 0.189; Second Step, p = 0.711). On the frontal plane, elderly subjects showed 0.39 degrees (p = 0.058) and 0.5 degree (p = 0.03) larger side-to-side sway angles in the first and second steps than young subjects, respectively. Gait stability can be analyzed using a more simplified experimental method with minimum amount of data in future gait analysis.
- 1 July 2021
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 38 (7) , 521-528
Comparative Study of Gait Stability Using COM-COP Inclination Angle Changes of Elderly
The current method of gait analysis has several limitations for determining gait stability, such as a complicated preparation process, repeated experimental procedures that are time-consuming, and financial burden of experiments. This study investigated whether gait stability could be analyzed using only the COM-COP (Center of Mass-Center of Pressure) inclination angle connecting COM and COP. COM and COP coordinates were obtained from a motion analysis system for a total of 40 elderly and young subjects. The COM-COP inclination angle that changed in real time during level walking was then analyzed to obtain gait stability on each of sagittal and frontal planes using these coordinates. As a result, the gait symmetry index on the sagittal plane did not show a statistically significant difference between young and elderly subjects (First Step, p = 0.189; Second Step, p = 0.711). On the frontal plane, elderly subjects showed 0.39 degrees (p = 0.058) and 0.5 degree (p = 0.03) larger side-to-side sway angles in the first and second steps than young subjects, respectively. Gait stability can be analyzed using a more simplified experimental method with minimum amount of data in future gait analysis.
- 9 January 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (1) , 417-422
Effect of fin length and shape of stemless humeral components in a reverse shoulder implant system: a FEA study
- 9 January 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (1) , 417-422
Effect of fin length and shape of stemless humeral components in a reverse shoulder implant system: a FEA study
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Biomechanical Effects of Aspect Ratio of the Knee during Outside‐In Anterior Cruciate Ligament Reconstruction Surgery
We analyzed tunnel length, graft bending angle, and stress of the graft according to tunnel entry position and aspect ratio (ASR: ratio of anteroposterior depth to mediolateral width) of the articular surface for the distal femur during single‐bundle outside‐in anterior cruciate ligament reconstruction (ACLR) surgery. We performed multiflexible body dynamic analyses with four ASR (98, 105, 111, and 117%) knee models. The various ASRs were associated with approximately 1 mm changes in tunnel length. The graft bending angle increased when the entry point was far from the lateral epicondyle and was larger when the ASR was smaller. The graft was at maximum stress, 117% ASR, when the tunnel entry point was near the lateral epicondyle. The maximum stress value at a 5 mm distance from the lateral epicondyle was 3.5 times higher than the 15 mm entry position, and the cases set to 111% and 105% ASR showed 1.9 times higher stress values when at a 5 mm distance compared with a 15 mm distance. In the case set at 98% ASR, the low‐stress value showed a without‐distance difference from the lateral epicondyle. Our results suggest that there is no relationship between the ASR and femoral tunnel length. A smaller ASR causes a higher graft bending angle, and a larger ASR causes greater stress in the graft.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessBiomechanical Effects of Aspect Ratio of the Knee during Outside‐In Anterior Cruciate Ligament Reconstruction Surgery
We analyzed tunnel length, graft bending angle, and stress of the graft according to tunnel entry position and aspect ratio (ASR: ratio of anteroposterior depth to mediolateral width) of the articular surface for the distal femur during single‐bundle outside‐in anterior cruciate ligament reconstruction (ACLR) surgery. We performed multiflexible body dynamic analyses with four ASR (98, 105, 111, and 117%) knee models. The various ASRs were associated with approximately 1 mm changes in tunnel length. The graft bending angle increased when the entry point was far from the lateral epicondyle and was larger when the ASR was smaller. The graft was at maximum stress, 117% ASR, when the tunnel entry point was near the lateral epicondyle. The maximum stress value at a 5 mm distance from the lateral epicondyle was 3.5 times higher than the 15 mm entry position, and the cases set to 111% and 105% ASR showed 1.9 times higher stress values when at a 5 mm distance compared with a 15 mm distance. In the case set at 98% ASR, the low‐stress value showed a without‐distance difference from the lateral epicondyle. Our results suggest that there is no relationship between the ASR and femoral tunnel length. A smaller ASR causes a higher graft bending angle, and a larger ASR causes greater stress in the graft.
- 1 October 2019
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 36 (10) , 983-988
Evaluation of Joint Load as Pre-Operative Traction in Fracture Reduction Surgeries of Femur and Tibia
Safe pre-operative traction applied and maintained to the fractured site in fracture reduction surgery is crucial. However, existing traction techniques performed by clinicians or manual traction devices are not elaborate and have no traction force information considering differences in patients’ bodies. The purpose of this study was to evaluate joint loads of fractured sites as pre-operative traction forces considering body mass index (BMI) during fracture reduction surgeries using a robotassisted device. We developed a lower-extremity dummy model to measure joint loads at hip, knee, ankle, and fractured sites. In 240 cases, four BMI types, six traction forces and two fractured sites were used. Results showed that joint load on major joints decreased as BMI increased. Additionally, joint load increased proportionally in the fractured tibia, but showed inverse tendency in the fractured femur. Control errors of up to 20% in repetitive control and approximately 30% in random control were measured, in comparison to estimated joint loads. Control error increased as traction force decreased. It is possible that applicability of robot systems to safe and precise surgical assistance can be validated. More precise traction control and real-time traction load monitoring technology will enable replacement of traction techniques in the near future.
- 1 October 2019
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 36 (10) , 983-988
Evaluation of Joint Load as Pre-Operative Traction in Fracture Reduction Surgeries of Femur and Tibia
Safe pre-operative traction applied and maintained to the fractured site in fracture reduction surgery is crucial. However, existing traction techniques performed by clinicians or manual traction devices are not elaborate and have no traction force information considering differences in patients’ bodies. The purpose of this study was to evaluate joint loads of fractured sites as pre-operative traction forces considering body mass index (BMI) during fracture reduction surgeries using a robotassisted device. We developed a lower-extremity dummy model to measure joint loads at hip, knee, ankle, and fractured sites. In 240 cases, four BMI types, six traction forces and two fractured sites were used. Results showed that joint load on major joints decreased as BMI increased. Additionally, joint load increased proportionally in the fractured tibia, but showed inverse tendency in the fractured femur. Control errors of up to 20% in repetitive control and approximately 30% in random control were measured, in comparison to estimated joint loads. Control error increased as traction force decreased. It is possible that applicability of robot systems to safe and precise surgical assistance can be validated. More precise traction control and real-time traction load monitoring technology will enable replacement of traction techniques in the near future.