APAntony L. Palmer

Antony L. Palmer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Antony L. Palmer has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A review of radiotherapy linear accelerator quality control techniques

    by Elisha Tassano-Smith, Antony L Palmer, Wojciech Polak, Andrew Nisbet

    This study provides a review of recent publications on different quality control (QC) techniques for radiotherapy linear accelerators (linacs). QC in radiotherapy is essential to ensure patient safety, deliver optimal quality treatments, monitor equipment performance over time, and to satisfy statutory or recommended testing. While conventional QC methods are still widely used and valuable, there have been advances in QC methods and approaches which aim to improve efficiency and keep pace with the rapidly advancing complexity of clinical equipment and treatment delivery methods. Existing reviews of QC concepts mainly focus on single QC techniques. There are limited reviews that explore and compare the variety of techniques to QC, which is the aim of this report. QC techniques were separated into 7 domains: conventional QC, automated and manufacturer integrated QC, risk, statistical, artificial intelligence (AI), end-to-end and patient-specific QC (PSQC), external dosimetry audits and clinical trial credentialing audits. An overview of each technique with example studies from literature is presented.

  • Open Access

    A survey and analysis of radiotherapy linear accelerator quality control in the United Kingdom, for c-arm and ring gantry systems and associated patient specific quality control

    by Elisha Tassano-Smith, Antony L Palmer, Wojciech Polak, Andrew Nisbet

    Objectives: To conduct a survey of radiotherapy linear accelerator quality control (QC) across the United Kingdom (UK) on behalf of the Institute of Physics and Engineering in Medicine (IPEM) Radiotherapy Special Interest Group and Interdepartmental Dosimetry Audit (IDA) Sub-committee. To update results from a similar survey published in 2012 and compare to the latest guidance from IPEM Report 81 (2018). There have been significant developments of equipment and clinical practice since the previous survey and IPEM publication, requiring an updated review and benchmark of QC practice. Methods: All UK radiotherapy centres were invited to complete a comprehensive survey of their local QC practice, with questions on c-arm gantry, ring-gantry, linac ancillary equipment, and patient-specific QC. Results: 63% (n = 43/68) of the UK radiotherapy centres responded. IPEM Report 81 was used to inform QC practice in 91% of centres. For the majority of tests studied centres were meeting or exceeding the recommendations of this report. Standard output was still performed weekly in 26% of centres compared to monthly recommendation in Report 81. Comprehensive tables of frequency and tolerances of QC tests were collated for c-arm and ring gantry linacs and ancillary equipment. Conclusions: A comprehensive review of consensus practice for linac QC radiotherapy across the UK is presented. Findings include the main stated reasons QC is undertaken is to “demonstrate safe use.” On efficiency, it was found that about half of centres state they undertake “the right amount of QC.” Half also state review of their QC process is “required.” Advances in knowledge: Updated data are presented on current practice for linac QC in the UK.


  • Open Access

    A review of kilovoltage radiotherapy treatment in the United Kingdom: quality control, radiation dosimetry, treatment equipment, and workload

    by Antony L Palmer, Jason Brimelow, Patrick Downes, Mayur Munshi, David Nash, Bhupinder Rai, Andrew R White

    Objectives: To survey kilovoltage (kV) radiotherapy in the United Kingdom, updating a 2016 study, focussing on radiotherapy physics, including equipment quality control (QC) and radiation dosimetry, with information on installed equipment and clinical activity. Methods: All UK radiotherapy physics departments (n = 68) were invited to complete a comprehensive survey. An analysis of the installed equipment base, patient numbers, clinical activity, QC testing, and radiation dosimetry processes were undertaken. Results: 91% of centres (n = 62) responded to the survey. kV radiotherapy was available in 70% of UK radiotherapy departments, with a wide variation in workload; 7-436 patients/centre annually. There has been an increase in centres using treatment calculation software rather than manual methods, up from 36% in 2016 to 50% currently. Only 50% of centres use an independent calculation check method. There was an increase in the use of the addendum to the UK dosimetry code of practice, enabling medium energy calibration in-air rather than at depth in phantom, citing “clinical relevance.” Appropriate levels of QC testing were being conducted at UK centres, with Institute of Physics and Engineering in Medicine (IPEM) Report 81 cited as a primary source of guidance. Good consensus for the frequency and tolerance values used for QC was seen across UK centres. Conclusions: A comprehensive review of consensus practice for QC and dosimetry in kV radiotherapy across the United Kingdom is presented, with supporting information on equipment installation and clinical use. Advances in Knowledge: Updated data are presented on kV radiotherapy treatment in the United Kingdom, with focus on physics aspects of QC and dosimetry.


  • Open Access

    National radiotherapy dosimetry audit in the UK – A vision and roadmap

    by Sarah Misson, Antony L Palmer, Patricia Diez, Mohammed Hussein, Catharine H Clark


  • Open Access

    Radiochromic film dosimetry in radiotherapy: a survey of current practice in the United Kingdom

    by Antony L Palmer, David Nash

    Objectives: To establish the variation in film dosimetry usage in radiotherapy centres across the United Kingdom. To identify consensus and highlight areas of potential improvement to enhance radiotherapy dosimetry verification with film. Methods: A survey questionnaire was designed by members of the Institute of Physics and Engineering in Medicine Interdepartmental Dosimetry Audit Group via Microsoft Forms and distributed to all Heads of Radiotherapy Physics in the United Kingdom. The survey was open from June 19, 2023, to July 31, 2023. Results: Forty responses were received from the 62 radiotherapy centres in the United Kingdom, of which 58% were currently using film dosimetry and a further 7 were keen to commence use. Many reported film use had decreased in recent years but was still valuable particularly for commissioning and implementing new techniques. The variation and consensus of methods for film dosimetry calibration, measurement, and application was established. A review of barriers to implementation and methods to reduce uncertainty were included in the assessment. Conclusions: A comprehensive assessment of film dosimetry usage in radiotherapy in the United Kingdom has been collated, which demonstrates a wide variation in methods, across typical clinical users, but maintains film as a valuable dosimetry option. Advances in knowledge: This research provides a snapshot of current film dosimetry use across the United Kingdom. It examines the variation and consensus of practice to which individual users can compare their systems, and identifies opportunities to improvement in the accuracy of film dosimetry.


  • Evaluation of a new radiochromic film dosimeter, Gafchomic EBT4, for VMAT, SABR and HDR treatment delivery verification

    by Antony L Palmer, David Nash, Wojciech Polak, Sarah Wilby

    Objective. To evaluate a new film for radiotherapy dosimetry, Gafchromic EBT4, compared to the current EBT3. To evaluate dose-response and verify test cases in MV external beam and HDR brachytherapy. Approach. Three lots (batches) of EBT4 and three lots of EBT3 films were calibrated at 6 MV over 0–1200 cGy range, using FilmQAPro software. Signal-to-noise of pixel value, reported dose (RD), and factors affecting dosimetry accuracy were evaluated (rotation of the film at scanning, energy response and post-exposure darkening). Both films were exposed to clinical treatment plans (VMAT prostate, SABR lung, single HDR source dwell, and ‘pseudo’ 3-channel HDR cervix brachytherapy). Film-RD was compared to TPS-calculated dose. Main results. EBT4 calibration curves had characteristics more favourable than EBT3 for radiation dosimetry, with improved signal to noise in film-RD of EBT4 compared to EBT3 (increase of average 46% in red and green channels at 500 cGy). Film rotation at scanning and post-exposure darkening was similar for the two films. The energy response of EBT4 is similar to EBT3. For all clinical case studies, EBT4 provided better agreement with the TPS-planned doses than EBT3. VMAT prostate gamma 3%/3 mm passing rate, EBT4 100.0% compared to EBT3 97.9%; SABR lung gamma 2%/2 mm, EBT4 99.6% and EBT3 97.9%; HDR cervix gamma 3%/2 mm, EBT4 97.7% and EBT3 95.0%. Significance. These results show EBT4 is superior to EBT3 for radiotherapy dosimetry validation of TPS plan delivery. Fundamental improvements in noise profile and calibration curve are reported for EBT4. All clinical test cases showed EBT4 provided equivalent or smaller difference in measured dose to TPS calculated dose than EBT3. Baseline data is presented on the achievable accuracy of film dosimetry in radiotherapy using the new Gafchromic EBT4 film.


  • Open Access

    Detection accuracy of I-125 seeds and needle tips, in MRI prostate tissue mimicking material: Phantom design, fabrication, and testing

    by Sarah Wilby, Antonio De Stefano, Antony L. Palmer, Wojciech Polak, Petko Petkov, Andrea Bucchi

  • A Bio-Inspired Active Prostate Phantom for Adaptive Interventions

    by Stefan Escaida Navarro, Sepaldeep Singh Dhaliwal, Mario Sanz Lopez, Sarah Wilby, Antony L. Palmer, Wojciech Polak, Rochdi Merzouki, Christian Duriez

    In this paper, a novel concept for a phantom of the prostate is introduced. To study and improve automated, robotized medical interventions, reliable phantoms are essential. During brachytherapy and biopsy, the prostate will undergo displacements and changes in orientation due to the needle insertion. Therefore, there is a shift in the target regions for radioactive seed deposition or biopsy acquisition. These shifts need to be taken into account for precise dosimetry. Furthermore, the organ can undergo deformations due to edemas causing further spatial changes in the target structure. Therefore, in this paper, we propose a bio-inspired phantom (BIP) for the prostate that is equipped with sensors and coupled with a numerical simulation for estimating deformations due to external forces. There is also a cavity within the phantom where pressure can be applied to simulate prostate growth due to inflammation. The phantom has been conceived to be MRI-safe. It can thus be deployed for the in-bore study of automated brachytherapy and biopsy. In our evaluation, we verify that changes in position of the phantom target can be correctly estimated and that these motions are plausible from a clinical point of view.


  • Open Access

    Radiation dosimetry changes in radiotherapy treatment plans for adult patients arising from the selection of the CT image reconstruction kernel

    by Anne T Davis, Sarah Muscat, Antony L. Palmer, David Buckle, James Earley, Matthew G.J. Williams, Andrew Nisbet

    Objective: The reconstruction kernel used for a CT scan strongly influences the image quality. This work investigates the changes in Hounsfield units (HUs) which can arise when altering the image reconstruction kernel for planning CT images and the associated changes in dose in the radiotherapy treatment plan if the treatment planning system (TPS) is not re-calibrated. Methods: Head and neck, prostate and lung CT images from four centres were used. For a specific scan, the base image was acquired using the original reconstruction kernel (used when the TPS was calibrated) and the treatment plan produced. The treatment plan was applied to all images from the other reconstruction kernels. Differences in dose-volume metrics for the planning target volume (PTV) and organs at risk (OARs) were noted and HU differences between images measured for air, soft tissue and bone. Results: : HU change in soft tissue had the greatest influence on dose change. When within ±20 HU for soft tissue and ±50 HU for bone and air the dose change in the PTV and OAR was within ±0.5% and ±1% respectively. Conclusions: : When imaging parameters were changed, if HU change was within ±20 HU for soft tissue and ±50 HU for bone and air, the change in the PTV and OAR doses was below 1%. Advances in knowledge: The degree of dose change in the treatment plan with HU change is demonstrated for current TPS algorithms. This adds to the limited evidence base for recommendations on HU tolerances as a tool for radiotherapy CT protocol optimization.