Anne T. Davis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anne T. Davis has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Nisbet
Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
5 shared publications Antony L. Palmer
Department of Medical Physics and Biomedical Engineering, University College London, UK; Department of Medical Physics, Portsmouth Hospitals University NHS Trust, Portsmouth, UK
3 shared publications- Antony L. Palmer
Portsmouth Hospitals NHS Trust, Portsmouth, UK; University of Surrey, Guildford, UK
3 shared publications Anand M. Ravindran
Department of Radiotherapy Physics, East Suffolk and North Essex Foundation Trust, Ipswich, UK
1 shared publicationAndrew Bird
Radiotherapy department, Worcestershire Oncology Centre, Worcestershire Acute Hospitals NHS Trust, UK
1 shared publicationAndrew Nisbet
Department of Medical Physics and Biomedical Engineering, University College London, UK
1 shared publication
Latest Publications
- 14 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104912
Assessment and improvement of the quality of radiotherapy treatment planning CT images using a clinically validated phantom based method and a multicentre intercomparison
- 14 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104912
Assessment and improvement of the quality of radiotherapy treatment planning CT images using a clinically validated phantom based method and a multicentre intercomparison
- 26 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 110-118
Improving the quality of head and neck radiotherapy CT images using a second image reconstruction set
- 26 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 110-118
Improving the quality of head and neck radiotherapy CT images using a second image reconstruction set
- 19 November 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1129) , 20210796
Analysis and results from a UK national dose audit of paediatric CT examinations
Objective: To present the results following a UK national patient dose audit of paediatric CT examinations, to propose updated UK national diagnostic reference levels (DRLs) and to analyse current practice to see if any recommendations can be made to assist with optimisation. Methods: A UK national dose audit was undertaken in 2019 focussing on paediatric CT examinations of the head, chest, abdomen/pelvis and cervical spine using the methods proposed by the International Commission on Radiological Protection. The audit pro-forma contained mandatory fields, of which the post-examination dosimetry (volume CT dose index and dose–length product) and the patient weight (for body examinations) were the most important. Results: Analysis of the data submitted indicates that it is appropriate to propose national DRLs for CT head examinations in the 0-<1, 1–<5, 5–<10 and 10–<15 year age ranges. This extends the number of age categories of national DRLs from those at present and revises the existing values downwards. For CT chest examinations, it is appropriate to propose national DRLs for the first time in the UK for the 5–<15, 15–<30, 30–<50 and 50–<80 kg weight ranges. There were insufficient data received to propose national DRLs for abdomen/pelvis or cervical spine examinations. Recommendations towards optimisation focus on the use of tube current (mA) modulation, iterative reconstruction and the selection of examination tube voltage (kVp). Conclusion: Updated UK national DRLs are proposed for paediatric CT examinations of the head and chest. Advances in knowledge: A national patient dose audit of paediatric CT examinations has led to the proposal of updated national DRLs.
- 19 November 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1129) , 20210796
Analysis and results from a UK national dose audit of paediatric CT examinations
Objective: To present the results following a UK national patient dose audit of paediatric CT examinations, to propose updated UK national diagnostic reference levels (DRLs) and to analyse current practice to see if any recommendations can be made to assist with optimisation. Methods: A UK national dose audit was undertaken in 2019 focussing on paediatric CT examinations of the head, chest, abdomen/pelvis and cervical spine using the methods proposed by the International Commission on Radiological Protection. The audit pro-forma contained mandatory fields, of which the post-examination dosimetry (volume CT dose index and dose–length product) and the patient weight (for body examinations) were the most important. Results: Analysis of the data submitted indicates that it is appropriate to propose national DRLs for CT head examinations in the 0-<1, 1–<5, 5–<10 and 10–<15 year age ranges. This extends the number of age categories of national DRLs from those at present and revises the existing values downwards. For CT chest examinations, it is appropriate to propose national DRLs for the first time in the UK for the 5–<15, 15–<30, 30–<50 and 50–<80 kg weight ranges. There were insufficient data received to propose national DRLs for abdomen/pelvis or cervical spine examinations. Recommendations towards optimisation focus on the use of tube current (mA) modulation, iterative reconstruction and the selection of examination tube voltage (kVp). Conclusion: Updated UK national DRLs are proposed for paediatric CT examinations of the head and chest. Advances in knowledge: A national patient dose audit of paediatric CT examinations has led to the proposal of updated national DRLs.
- 1 October 2020
- Published by Elsevier in Physica Medica
- Vol. 78, 38-47
Can different Catphan phantoms be used in a multi-centre audit of radiotherapy CT image quality?
- 1 October 2020
- Published by Elsevier in Physica Medica
- Vol. 78, 38-47
Can different Catphan phantoms be used in a multi-centre audit of radiotherapy CT image quality?
- Open Access
- 1 November 2019
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 1 (1)
Radiation dosimetry changes in radiotherapy treatment plans for adult patients arising from the selection of the CT image reconstruction kernel
Objective: The reconstruction kernel used for a CT scan strongly influences the image quality. This work investigates the changes in Hounsfield units (HUs) which can arise when altering the image reconstruction kernel for planning CT images and the associated changes in dose in the radiotherapy treatment plan if the treatment planning system (TPS) is not re-calibrated. Methods: Head and neck, prostate and lung CT images from four centres were used. For a specific scan, the base image was acquired using the original reconstruction kernel (used when the TPS was calibrated) and the treatment plan produced. The treatment plan was applied to all images from the other reconstruction kernels. Differences in dose-volume metrics for the planning target volume (PTV) and organs at risk (OARs) were noted and HU differences between images measured for air, soft tissue and bone. Results: : HU change in soft tissue had the greatest influence on dose change. When within ±20 HU for soft tissue and ±50 HU for bone and air the dose change in the PTV and OAR was within ±0.5% and ±1% respectively. Conclusions: : When imaging parameters were changed, if HU change was within ±20 HU for soft tissue and ±50 HU for bone and air, the change in the PTV and OAR doses was below 1%. Advances in knowledge: The degree of dose change in the treatment plan with HU change is demonstrated for current TPS algorithms. This adds to the limited evidence base for recommendations on HU tolerances as a tool for radiotherapy CT protocol optimization.
- 1 November 2019
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 1 (1)
Open AccessRadiation dosimetry changes in radiotherapy treatment plans for adult patients arising from the selection of the CT image reconstruction kernel
Objective: The reconstruction kernel used for a CT scan strongly influences the image quality. This work investigates the changes in Hounsfield units (HUs) which can arise when altering the image reconstruction kernel for planning CT images and the associated changes in dose in the radiotherapy treatment plan if the treatment planning system (TPS) is not re-calibrated. Methods: Head and neck, prostate and lung CT images from four centres were used. For a specific scan, the base image was acquired using the original reconstruction kernel (used when the TPS was calibrated) and the treatment plan produced. The treatment plan was applied to all images from the other reconstruction kernels. Differences in dose-volume metrics for the planning target volume (PTV) and organs at risk (OARs) were noted and HU differences between images measured for air, soft tissue and bone. Results: : HU change in soft tissue had the greatest influence on dose change. When within ±20 HU for soft tissue and ±50 HU for bone and air the dose change in the PTV and OAR was within ±0.5% and ±1% respectively. Conclusions: : When imaging parameters were changed, if HU change was within ±20 HU for soft tissue and ±50 HU for bone and air, the change in the PTV and OAR doses was below 1%. Advances in knowledge: The degree of dose change in the treatment plan with HU change is demonstrated for current TPS algorithms. This adds to the limited evidence base for recommendations on HU tolerances as a tool for radiotherapy CT protocol optimization.
- 1 August 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1076) , 20160406
Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review
This article reviews publications related to the use of CT scans for radiotherapy treatment planning, specifically the impact of scan protocol changes on CT number and treatment planning dosimetry and on CT image quality. A search on PubMed and EMBASE and a subsequent review of references yielded 53 relevant articles. CT scan parameters significantly affect image quality. Some will also affect Hounsfield unit (HU) values, though this is not comprehensively reported on. Changes in tube kilovoltage and, on some scanners, field of view and reconstruction algorithms have been found to produce notable HU changes. The degree of HU change which can be tolerated without changing planning dose by >1% depends on the body region and size, planning algorithms, treatment beam energy and type of plan. A change in soft-tissue HU value has a greater impact than changes in HU for bone and air. The use of anthropomorphic phantoms is recommended when assessing HU changes. There is limited published work on CT scan protocol ...
- 1 August 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1076) , 20160406
Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review
This article reviews publications related to the use of CT scans for radiotherapy treatment planning, specifically the impact of scan protocol changes on CT number and treatment planning dosimetry and on CT image quality. A search on PubMed and EMBASE and a subsequent review of references yielded 53 relevant articles. CT scan parameters significantly affect image quality. Some will also affect Hounsfield unit (HU) values, though this is not comprehensively reported on. Changes in tube kilovoltage and, on some scanners, field of view and reconstruction algorithms have been found to produce notable HU changes. The degree of HU change which can be tolerated without changing planning dose by >1% depends on the body region and size, planning algorithms, treatment beam energy and type of plan. A change in soft-tissue HU value has a greater impact than changes in HU for bone and air. The use of anthropomorphic phantoms is recommended when assessing HU changes. There is limited published work on CT scan protocol ...
- 1 February 2015
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 44 (2) , 20140223
The reduction of dose in paediatric panoramic radiography: the impact of collimator height and programme selection
The aim of this work was to estimate the doses to radiosensitive organs in the head of a young child undergoing panoramic radiography and to establish the effectiveness of a short collimator in reducing dose. Thermoluminescent dosemeters were used in a paediatric head phantom to simulate an examination on a 5-year-old child. The panoramic system used was an Instrumentarium OP200 D (Instrumentarium Dental, Tuusula, Finland). The collimator height options were 110 and 140 mm. Organ doses were measured using exposure programmes intended for use with adult and child size heads. The performance of the automatic exposure control (AEC) system was also assessed. The short collimator reduced the dose to the brain and the eyes by 57% and 41%, respectively. The dose to the submandibular and sublingual glands increased by 32% and 20%, respectively, when using a programme with a narrower focal trough intended for a small jaw. The effective dose measured with the short collimator and paediatric programme was 7.7 μSv. The dose to the lens of the eye was 17 μGy. When used, the AEC system produced some asymmetry in the dose distribution across the head. Panoramic systems when used to frequently image children should have programmes specifically designed for imaging small heads. There should be a shorter collimator available and programmes that deliver a reduced exposure time and allow reduction of tube current. Programme selection should also provide flexibility for focal trough size, shape and position to match the smaller head size.
- 1 February 2015
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 44 (2) , 20140223
The reduction of dose in paediatric panoramic radiography: the impact of collimator height and programme selection
The aim of this work was to estimate the doses to radiosensitive organs in the head of a young child undergoing panoramic radiography and to establish the effectiveness of a short collimator in reducing dose. Thermoluminescent dosemeters were used in a paediatric head phantom to simulate an examination on a 5-year-old child. The panoramic system used was an Instrumentarium OP200 D (Instrumentarium Dental, Tuusula, Finland). The collimator height options were 110 and 140 mm. Organ doses were measured using exposure programmes intended for use with adult and child size heads. The performance of the automatic exposure control (AEC) system was also assessed. The short collimator reduced the dose to the brain and the eyes by 57% and 41%, respectively. The dose to the submandibular and sublingual glands increased by 32% and 20%, respectively, when using a programme with a narrower focal trough intended for a small jaw. The effective dose measured with the short collimator and paediatric programme was 7.7 μSv. The dose to the lens of the eye was 17 μGy. When used, the AEC system produced some asymmetry in the dose distribution across the head. Panoramic systems when used to frequently image children should have programmes specifically designed for imaging small heads. There should be a shorter collimator available and programmes that deliver a reduced exposure time and allow reduction of tube current. Programme selection should also provide flexibility for focal trough size, shape and position to match the smaller head size.