LSLucíola Lucena de Sousa

Lucíola Lucena de Sousa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lucíola Lucena de Sousa has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Rapid Solidification Processing on the Microstructure and Corrosion of 316L Austenitic Stainless Steel

    by Raíra Chefer Apolinario, Isabela Daianezi, Spyridion Haritos Borges, Lucíola Lucena de Sousa, Haroldo Cavalcanti Pinto, Neide Aparecida Mariano


  • Open Access

    Temperature and time effect of thermal aging treatment on microstructure and corrosion resistance of UNS S31803 duplex stainless steel

    by Isabela Dainezi, Spyridion Haritos Borges, Luciola Lucena de Sousa, Neide Aparecida Mariano

    Duplex stainless steels correspond to a class of steel in which the microstructure is composed basically by the phases ferrite and austenite. Given the metastable character of ferrite, associated phase transformations can occur during thermal treatments, which can lead to a reduction in corrosion resistance. Therefore, the aim of this work was to evaluate the influence of the solution-treated at 1100°C for 30min and aging at 500 and 600°C for 1, 3 and 12h, on the microstructure and corrosion resistance of DSS UNS S31803. The steels were characterized by SEM, EDS, XRD, hardness, microhardness and thermal analysis. The steels aged at 500°C for 1h presented the phase alpha line dispersed in the ferrite, and the steels aged at 600°C for 12h presented the phases alpha line, sigma and chi. In the assays of double cycle potentiodynamic reactivation in solution of 0.5M H2SO4 and 0.01M KSNC, it was observed that no sensitization occurred. Furthermore, in the tests of cyclic potentiodynamic polarization, in 3.5% NaCl solution, it was verified that the precipitation of the alpha line phase did not alter corrosion resistance; nevertheless, the sigma phase reduced corrosion resistance.


  • Spark plasma sintering of Ti6Si2B-based Ti-Si-B alloys and their corrosion resistance in artificial saliva and SBF media

    by Bárbara de Oliveira Fiorin, Troy Holland, Lucas Moreira Ferreira, Lucíola Lucena de Sousa, Neide Aparecida Mariano, Carlos Angelo Nunes, Marcello Filgueira, Alfeu Saraiva Ramos


  • Open Access

    Biomimetic coating on titanium: evaluation of bioactivity and corrosion

    by Mariny Fabiéle Cabral Coelho, Lucíola Lucena de Sousa, Carolina Cruz Ferreira, Brenda Fernanda Gaspar de Souza, Eliana Cristina da Silva Rigo, Neide Aparecida Mariano

    Pure titanium and its alloys have been widely applied as implant material with excellent results in a long term because of their excellent biocompatibility and resistance to corrosion. Biomaterials with porous structure optimize the interfacial resistance between the material and the bone, leading to a more efficient fixation of the implant by bone growth in the pores. Titanium implants covered with calcium phosphates have received increasing application in odontology and orthopedics, and clinical studies indicate that the healthy bone tissue responds positively to the bioceramic surfaces. Calcium phosphates, particularly hydroxyapatite in the form of coating, provide a bioactive surface to the metal, which induces the direct union between the implant and the bone tissue. Consequently, the time for osseointegration and, therefore, the total time for treatment, can be reduced. Researches have been conducted to obtain a coating, in order to enhance the adherence between bone and implant, modifying the metal surface, allowing an efficient regeneration of the bone tissue, osseointegration and accelerating its growth. In this work, the effect of coating by the biomimetic method on a titanium substrate was studied, consisting of the immersion of the substrate in a synthetic SBF (Simulated Body Fluid) solution, with composition, pH and temperature similar to blood plasma. The coating was efficient for obtaining hydroxyapatite, which was confirmed by the techniques of scanning electron microscopy (SEM), X-ray diffraction (XRD) and infrared. The bioactivity assay revealed that the samples which received the coating with 1.5 SBF presented bioactive characteristic by the formation and development of the carbonated hydroxyapatite on the surface, in a superior way to the samples without coating, thus suggesting a fast osseointegration of the bone with the implant. The polarization curves showed that the titanium without coating presented a higher resistance to corrosion compared to the titanium with coating.


  • Microstructure and corrosion behavior in SBF medium of spark plasma sintered Ti-xZr-20Si-10B (x = 5, 7, 10, 15, 20 at.-%) alloys

    by Isadora Rossi Bertoli, Marcello Filgueira, Lucas Moreira Ferreira, Lucíola Lucena de Sousa, Neide Aparecida Mariano, Alfeu Saraiva Ramos, Carlos Angelo Nunes, Claudinei dos Santos, Erika Coaglia Trindade Ramos


  • Open Access

    Characterization Alloys of the Sn-Zn System Produced by Melt Spinning

    by Luis Gustavo Cordiolli Russi, Lucíola Lucena de Sousa, Alfeu Saraiva Ramos, Piter Gargarella, Neide Aparecida Mariano

  • Open Access

    Titanium Biomimetically Coated With Hydroxyapatite, Silver Nitrate and Polycaprolactone, for Use In Biomaterials (Biomedicine)

    by Carolina Cruz Ferreira, Lucíola Lucena de Sousa, Virgilio Pereira Ricci, Eliana Cristina da Silva Rigo, Alfeu Saraiva Ramos, Maria Gabriela Nogueira Campos, Neide Aparecida Mariano

    Titanium is used in orthopedic and orthodontic implants because it has good corrosion resistance and excellent biocompatibility. Thus, studies seek to obtain a coating to improve the adhesion between the bone and the implant, by modifying the metal’s surface. The objective of this work was to biomimetically coat C.P. Ti with hydroxyapatite doped with silver nitrate, a component with antimicrobial properties, coating the metallic-ceramic composite with a polycaprolactone polymer film, which is known by generate improved implant-tissue interaction, and reducing postoperative complications from bacterial infections. The characterization of the material demonstrated the existence of the coating overall surface of the metallic substrate. The results obtained from the bacterial culture tests with Staphylococcus aureus showed that nitrate was effective in reducing the amount of live bacteria present in the supernatant, as well as those adhered to the surface of the material. In addition, the polymeric coating did not prevent the release of the bactericidal agent, not interfering in the effect there.


  • Open Access

    Influence of Molybdenum on Microstructure and Pitting Corrosion Behavior of Solution-Treated Duplex Stainless Steel in a Lithium Chloride Solution

    by Stephania Cappellari de Rezende, Isabela Dainezi, Raíra Chefer Apolinario, Lucíola Lucena de Sousa, Neide Aparecida Mariano

    With technological advances in the several areas of knowledge, the constant search for materials with characteristics that meet certain applications has been growing, especially in the chemical and petrochemical industries, where materials capable of withstanding the conditions of corrosion in aggressive environments are required. The aim of this paper was to analyze the influence of the alloy element molybdenum on the microstructure and the resistance to corrosion of two duplex stainless steels identified as A (with molybdenum) and B (without molybdenum), after solution-treated under the following conditions: heating at 1100ºC for 30, 120 and 240 minutes. The steels were characterized by SEM, EDS, DRX and microhardness. The rise in solution treatment time fostered an increase in the volumetric fraction of the ferrite phase, in both steels. The solution treatment at 1100ºC for 120 minutes, for steels A and B, provided good resistance to pit corrosion, as well as the development of a passivating film in the solution of lithium chloride (120,000 ppm of chloride ions).


  • Evaluation of the Bactericidal Properties of the Biomimetic Coating of Ha Doped with AgNO3

    by Lucíola Lucena de Sousa, Deborah Gouvêa Prado, Mariny Fabiéle Cabral Coelho, Virgilio Pereira Ricci, Guilherme Vilela Ferreira, Eliana C. da S. Rigo, Mérilin Cristina dos Santos Fernandes, Neide Aparecida Mariano

    Commercially pure titanium and its alloys have been widely applied as implant materials with excellent long-term results and present benefits compared to other metal biomaterials because of the good mechanical strength and modulus of elasticity with values close to those of the bone. Titanium implants coated with hydroxyapatite give the metal a bioactive surface, which induces a direct connection between the implant and the bone tissue. As a consequence, the time for osseointegration, and hence the total treatment time, may be reduced. This paper aimed at studying the bactericidal effect of silver nitrate at 10 ppm and 100 ppm, incorporated in the layer on the surface of commercial titanium. The results showed efficiency in both osseointegration and bactericidal effect, confirmed by scanning electron microscopy, X-ray diffraction and corrosion tests. The bacterial culture tests, by means of the halo inhibition tests, indicate that the doping with AgNO3 in concentrations 10 and 100 ppm did not present significant variation.

  • Effect of Solution Annealing Time on the Microstructure and Corrosion Resistance of Duplex Stainless Steel

    by Stephania Capellari de Rezende, Maria Eurenice Rocha Cronemberger, Rodrigo Silva, Carlos A. Della Rovere, Sebastião Elias Kuri, Lucíola Lucena de Sousa, Neide Aparecida Mariano

    The formation of intermetallic phases during thermal treatments is a decisive point for the performance of duplex stainless steels, which may prevent the obtaining or provoke degradation of their properties. This paper presents an investigation on the corrosion resistance of duplex SAF 2205 steel as received and after solution annealing treatment. The objective was to evaluate the correlation between the solution annealing time, the resulting microstructural changes and the corrosion resistance of the steel through electrochemical tests of cyclic potentiodynamic polarization and double-cycle potentiokinetic reactivation (DL-EPR). The heat treatments were performed at 1100° C for 30, 120 and 240 min with subsequent air cooling. The results of the DL-EPR showed that although there was no presence of intermetallic phases even with the absence of intermetallic phases, the solution annealing time influenced the degree of chromium depletion of the samples, so that with the increase of time, there was an increase in the degree of chrome depletion.