Latest Publications

  • Open Access

    Impact of Synchronous Condensers’ Ratings on Mitigating Subsynchronous Oscillations in Wind Farms

    by Dimitrios Dimitropoulos, Mohammad Kazem Bakhshizadeh, Lukasz Kocewiak, Xiongfei Wang, Frede Blaabjerg

    Subsynchronous oscillations have occurred in wind farms due to the high penetration of converter-based technology in power systems and may potentially lead to grid instability. As an effective solution, synchronous condensers, with their ability to control voltage and inject reactive power in the power system, are increasingly being adopted, as they can lead to the mitigation of such oscillations in weak grid conditions. However, the impact of synchronous condensers’ power ratings on system stability is a topic that requires further investigation. In fact, an improper selection of a synchronous condenser’s rating will not extinguish existing subsynchronous oscillations and may even cause the emergence of new oscillatory phenomena. This paper presents a novel examination of the impact that the synchronous condenser’s power rating has on the small-signal stability of a wind farm with existing subsynchronous oscillations while being connected to a weak grid. The wind farm’s model is developed using state-space modeling, centering on grid interconnection and incorporating the state-space submodel of a synchronous condenser to show its impact on subsynchronous oscillation mitigation. The stability analysis determines the optimal synchronous condenser’s power ratings for suppressing these oscillations in the wind farm model. The findings are corroborated through time domain simulations and fast-Fourier transformation (FFT) analysis, which further validate the stability effects of a synchronous condenser’s rating.


  • Open Access

    An Extended Nonlinear Stability Assessment Methodology For Type-4 Wind Turbines via Time Reversal Trajectory

    by Sujay Ghosh, Mohammad Kazem Bakhshizadeh, Guangya Yang, Łukasz Kocewiak

    As the integration of renewable energy generation increases and as conventional generation is phased out, there is a gradual decline in the grid's strength and resilience at the connection point of wind turbines (WTs). Previous studies have shown that traditional grid-following controlled converters exhibit deteriorating dynamic characteristics and may result in an unstable system when connected to a weak grid. Due to the limitations of linear analysis, transient stability investigations are necessary. However, existing methods, such as standalone time-domain simulations or analytical Lyapunov stability criteria, have drawbacks, including computational intensity or excessive conservatism. Our prior research proposed an innovative approach to estimate the system boundary - a time-limited region of attraction (TLRoA), using a hybrid linearised Lyapunov function-based method and the time-reversal technique to compensate for the known limitations. However, in that work, the accuracy of the estimated TLRoA was not investigated, i.e. the TLRoA was not compared against a forward simulated region of attraction, and the sensitivity of the system parameters on the TLRoA was not explored. Moreover, the framework did not consider nonlinear control elements such as PLL saturation. In this paper, we not only build upon our previous work and propose directions that address these gaps but also enhance its effectiveness by introducing optimal sampling to improve further the speed of estimating the TLRoA. Furthermore, the stability boundary is verified using time-domain simulation studies in PSCAD.

  • Open Access

    Nonlinear Stability Boundary Assessment of Multi-Converter Systems Based On Reverse Time Trajectory

    by Sujay Ghosh, Mohammad Kazem Bakhshizadeh, Guangya Yang, Łukasz Kocewiak

    As the integration of wind power accelerates, wind power plants (WPPs) are expected to play a crucial role in ensuring stability in future power grids. This paper examines the nonlinear stability boundary of a multi-converter system in a wind power plant (WPP) connected to an AC power grid via a long HVAC cable. Traditionally, for nonlinear analysis of WPPs, a simplification is adopted wherein the WPP is treated as an aggregation of individual wind turbines (WTs), with a simplified portrayal of the collector network. However, in the presence of different technologies, such as STATCOM, that are placed away from the WTs, the model aggregation will not hold. This paper presents a unified methodology to model and investigate the high-dimensional stability boundary of a WPP with a STATCOM. The stability region of the system, i.e. the region of attraction (RoA), is determined by the reverse time (backwards) trajectory technique. Furthermore, the estimated stability boundary is verified using time-domain simulation studies in PSCAD.

  • Open Access

    Nonlinear Stability Investigation of Type-4 Wind Turbines With Non-Autonomous Behavior Based on Transient Damping Characteristics

    by Sujay Ghosh, Mohammad Kazem Bakhshizadeh, Guangya Yang, Łukasz Kocewiak, Bikash C. Pal, Mithulan Nadarajah

    As wind and solar power penetration increases, more and more conventional power plants are being replaced; as a result, the nature of transient stability of the system evolves where the converter’s behaviour play dominating role during network events. This has necessitated a re-assessment of the nonlinear stability of the system. So far, the energy function-based transient stability method applied to synchronous machines has been applied to the converter-based system. However, there is ambiguity in terms of the damping quantification capturing the non-autonomous behaviour of the wind turbine systems, such as post-fault active current ramp rate control. This work aims to clarify the similarity between the synchronous machine model and a reduced large signal model of a wind turbine, and the difference in terms of the damping characteristics and how this impacts the system’s stability from a nonlinear perspective. A non-autonomous energy function is discussed that analytically proves that a wind turbine system with post-fault active ramp rate control is more stable compared to no ramp rate control. Finally, the stability boundary is constructed and validated using time-domain simulation studies.


  • Open Access

    Improved Reduced-Order Model for PLL Instability Investigations

    by Mohammad Kazem Bakhshizadeh, Sujay Ghosh, Łukasz Kocewiak, Guangya Yang

    There is a rapid increase in the installed capacity of offshore wind power plants (WPPs) worldwide, and the trend will continue in the context of the recent EU energy crisis and the Ukraine war. As the share of the capacity of wind power plants increases in power systems, it is essential that WPPs can stay connected with the grid during different operational events and provide ancillary services. Recent research has identified the Phase Locked Loop (PLL) converter control as a contributing factor to instabilities driven by large-signal disturbances (i.e. severe grid faults). This type of instability is referred to as grid-synchronisation stability (GSS). In light of this, grid codes are being revised to secure the connection of WPPs and specify the services that need to be provided. To study GSS, it is essential to model the wind turbine (WT) system and grid conditions accurately. However, the actual WT models are often unavailable, black-boxed, or computationally too heavy to model in detail. Thus, simplified reduced-order models (ROM) resembling the actual system behaviour are the need of the hour. This paper presents an improved reduced-order model that considers a systematic approach to modelling the misalignment of the PLL angle in the converter states. Moreover, it considers the time-varying parameters and the step changes of initial states after fault triggering, which otherwise are neglected in the present literature. Our focus in this paper is to propose a novel WT ROM and demonstrate its effectiveness for offline studies. Based on transient stability studies, the improved reduced-order model correctly tracks the grid-angle post grid disturbances, and its trajectory is a good match compared to a detailed simulation mode in time domain.


  • Open Access

    Modal Aggregation Technique to Check the Accuracy of the Model Reduction of Array Cable Systems in Offshore Wind Farms

    by Mohammad Kazem Bakhshizadeh, Benjamin Vilmann, Łukasz Kocewiak

    The need for a verification method for aggregation techniques for passive electrical systems is necessary as power systems increase in complexity. Model reduction is crucial to increase the number of simulations necessary to ensure a stable and reliable design of power systems. This paper presents a novel modal domain-based technique to identify the best aggregation technique for a given system and to indicate the validity of the aggregation. This is done by benchmarking different aggregation techniques and using the dominant contribution factor ratio as a validity parameter. The different aggregation techniques are compared via time-domain simulations against the full detailed model. It is found that (1) the power loss aggregation technique is the most precise when it weighs the equivalent impedances of the parallel feeders, (2) unequal current generation does not impact the aggregation accuracy, (3) individual string aggregation provides the best results for dynamic simulations, and (4) the validity of aggregation decreases as frequency or cable length increases.


  • Improving the Impedance-Based Stability Criterion by Using the Vector Fitting Method

    by Mohammad Kazem Bakhshizadeh, Frede Blaabjerg, Jesper Hjerrild, Lukasz Kocewiak, Claus Leth Bak

    In this paper, some issues related to the impedance based stability criterion such as RHP poles in the minor loop gain, how to specify source and load impedances, and node-dependent stability margins are discussed and the vector fitting method is used to improve the method. This results in an eigenvalue analysis of the system instead of using the Nyquist diagram, and leads to obtain more information about the system. Furthermore, a participation factor analysis can be used to identify the problematic subsystem. The proposed method is examined in the assessment of a stable and an unstable system and simulation results are used for verification


  • Selective Harmonic Elimination Technique With Control of Capacitive DC-Link Voltages in an Asymmetric Cascaded H-Bridge Inverter for STATCOM Application

    by Rahman Sajadi, Hossein Iman-Eini, Mohammad Kazem Bakhshizadeh, Yousef Neyshabouri, Shahrokh Farhangi

    In this paper, the selective harmonic elimination (SHE) technique is introduced for a cascaded H-bridge-based static VAR compensator (CHB-STATCOM) with unequal capacitive dc-link voltages. The asymmetric topology allows increasing the number of voltage levels while keeping the converter losses low. Moreover, reactive power control is realized by using the decoupled current control, and the voltage of individual capacitors is controlled by the help of SHE modulation. Mathematical equations are derived for synthesizing the multilevel ac waveform and regulation of dc-link voltages for a CHB inverter with an arbitrary number of H-bridge cells. Then, to verify the theoretical claims, simulation and experimental results are provided for a three-phase CHB inverter with two H-bridge cells in each phase.


  • A Numerical Matrix-Based Method for Stability and Power Quality Studies Based on Harmonic Transfer Functions

    by Mohammad Kazem Bakhshizadeh, Frede Blaabjerg, Jesper Hjerrild, Xiongfei Wang, Lukasz Kocewiak, Claus Leth Bak

    Some couplings exist between the positive- and negative-sequence impedances of a voltage-sourced power converter especially in the low frequency range due to the nonlinearities and low-bandwidth control loops such as the phase-locked loop. In this paper, a new numerical method based on the harmonic transfer function for analysis of the linear time periodic systems is presented, which is able to handle these couplings. In a balanced three-phase system, there is only one coupling term, but in an unbalanced (asymmetrical) system, there are more couplings, and therefore, in order to study the interactions between these couplings a matrix-based method should be used. No information about the structure of the converter is needed and elements are modeled as black boxes with known terminal characteristics. The proposed method is applicable for both power quality (harmonic and interharmonic emissions) and stability studies, which is verified by simulations in this paper.


  • Open Access

    The Application of Vector Fitting to Eigenvalue-Based Harmonic Stability Analysis

    by Mohammad Kazem Bakhshizadeh, Changwoo Yoon, Jesper Hjerrild, Claus Leth Bak, Lukasz Hubert Kocewiak, Frede Blaabjerg, Bo Hesselbaek

    Participation factor analysis is an interesting feature of the eigenvalue-based stability analysis in a power system, which enables the developers to identify the problematic elements in a multivendor project like in an offshore wind power plant. However, this method needs a full state-space (SS) model of the elements that is not always possible to have in a competitive world due to confidentiality. In this paper, by using an identification method, the SS models for power converters are extracted from the provided data by the suppliers. Some uncertainties in the identification process are also discussed and solutions are proposed, and in the end the results are verified by time domain simulations for linear and nonlinear cases with different complexities, no matter which domain (phase or dq) is used.