LCLuciana Tourinho Campos

Luciana Tourinho Campos

*This is an algorithmically generated author record based on publicly available information.

Luciana Tourinho Campos has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Context-dependent modulation of epithelial–mesenchymal transition–associated markers and migration behavior by mammography-equivalent low-dose radiation in established breast cell lines

    by Leslie Pereira, Antonio G. F. Lima, Marcella T. Ferreira, Ellen V. Silva, Laila R. Fernandes, Luís A. G. Magalhães, Luciana T. Campos, Verônica Morandi, Samara C. Ferreira-Machado

    Mammography is an essential breast cancer screening tool that uses low doses of ionizing radiation. Determining whether such exposures modulate cellular processes associated with epithelial plasticity remains important. This preliminary study investigated whether clinically relevant radiation doses (≈2.14 mGy per exposure) influence epithelial-mesenchymal transition (EMT)-associated markers and motility in breast cell lines. Human breast cell lines MCF-10A (non-tumorigenic), MCF-7 (luminal, ER+), and MDA-MB-231 (triple-negative) were exposed to single (2.14 mGy) or repeated (2.14 + 2.14 mGy) doses. Exposure was defined using a Monte Carlo-estimated glandular-equivalent dose derived from a breast-equivalent phantom under mammographic conditions. EMT-associated markers (E-cadherin, fibronectin, vimentin), collective migration, extracellular matrix invasion, MMP-2/9 activity, and transendothelial migration were assessed. Low-dose irradiation induced cell-specific modulation of EMT-associated markers and motility (p-values correspond to single and repeated exposures, respectively). In MCF-10A cells, E-cadherin expression decreased (p = 0.0025; p = 0.028). A fibronectin degradation pattern was observed under both regimens; however, total band quantification (220 kDa subunit plus smaller fragments) was unchanged. Collective migration increased modestly (p < 0.05), while invasion through a basement membrane matrix increased markedly (p < 0.0001), and MMP-9 activity decreased (p < 0.0001). In MCF-7 cells, irradiation increased fibronectin (p = 0.05, repeated doses), enhanced collective migration (p < 0.05; p < 0.001), abolished MMP-2 activity in controls (in both treatments), and reduced MMP-9 activity (p < 0.0001), without altering invasion. In MDA-MB-231 cells, vimentin expression was upregulated after repeated exposures (p = 0.0067), while fibronectin expression decreased (p = 0.035; p = 0.046). Matrix invasion increased after single and repeated exposures (p < 0.05; p < 0.0001), MMP-9 activity increased after single exposure (p < 0.0001), and transendothelial migration decreased after single and repeated exposures (p < 0.01; p < 0.0001), without changes in collective migration. MMP-2 activity was undetectable in MCF-10A and MDA-MB-231 cells. Mammography-equivalent radiation doses were associated with lineage-dependent modulation of EMT-associated markers and cellular motility in vitro, indicating context-dependent phenotypic effects of clinically relevant low-dose radiation.

  • Open Access

    Quality control of radiotherapy treatment plans with electrons

    by Luciana Tourinho Campos, Luiz Ribeiro Da Rosa, Delano Valdivino Batista, Delson Braz

    In this work the quality of the treatment planning generated by EclipseÒ commercial treatment planning system for electron beams of energy 9 and 20 MeV was verified and their accuracy in the calculation of dose distributions for several clinical situations was evaluated. Tests cases had been developed according to the Brazilian reality, having as reference the radiotherapy treatments carried out in the National Institute of the Cancer.The system developed for checking the quality of treatment planning systems with electrons was efficient in evaluating the Eclipse planning system by identifying the failures of their algorithms, especially in planning the isodose. The verification system has been validated against the Monte Carlo method and the experimental data with an ionization chamber and showed the shortcomings of generalized pencil beam and eMC algorithms.

  • Open Access

    Determination of a beam quality conversion factor from 60Co to 192Ir

    by Luciana Tourinho Campos, Luis Alexandre Gonçalves Magalhães, Carlos Eduardo Veloso de Almeida


  • Open Access

    Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    by L T Campos, S P Leite, C E V de Almeida, L A G Magalhães

    Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.

  • Open Access

    An Efficiency Studying of an Ion Chamber Simulation Using Vriance Reduction Techniques with EGSnrc

    by L T Campos, L A Magalhães, C E V de Almeida

    Radiotherapy is an important technique of cancer treatment using ionizing radiation. The determination of total dose in reference conditions is an important contribution to uncertainty that could achieve 2%. The source of this uncertainty comes from cavity theory that relates the in-air cavity dose and the dose to water. These correction factors are determined from Monte Carlo calculations of ionization chambers. The main problem of this type of calculation is the extremely long computation time to achieve reasonable statistics. The main purpose of this work is to present a combination with variance reduction techniques for the case of an ionization chamber in water. The egs_chamber code allows for very efficient computation of ionization chamber doses and dose ratios by using various variance reduction techniques, and also permits realistic simulations of the experimental setup due to the use of EGSnrc C++ library. Russian roulette and Photon Cross Section Enhancement were used with egs_chamber code. Tests were performed to obtain the parameters of variance reduction techniques resulting in a maximum efficiency. It can be seen that the parameters which result in improved Monte Carlo calculation of the efficiency values are XCSE 64 and Russian Roulette (RR) 128. This study determines the parameters of variance reduction techniques that result in an optimal computational efficiency.

  • Open Access

    Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy

    by Luciana Tourinho Campos, Carlos Eduardo Veloso de Almeida

    The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®); it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86), which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21), which is also from BEBIG. The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair production, Rayleigh scattering and bound Compton scattering were included in the simulation. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. The cut-off energy was 10 keV for electrons and photons. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. The liquid water density was 0.998 g/cm3, and photon histories of up to 1010 were used to obtain the results with a standard deviation of less than 0.5% (k = 1). The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range.


  • Open Access

    Monte Carlo Simulation of Bony Heterogeneity Effects on Dose Profile for Small Irradiation Field in Radiotherapy

    by Simone C. Cardoso, Victor Gabriel L. Alves, Luiz Antonio R. da Rosa, Luciana T. Campos, Delano V. S. Batista, Alessandro Facure

    In the radiotherapy treatment planning of a lesion located in the head region with small field radiation beams, the heterogeneity corrections play an important role. In this work, we investigated the influence of a bony heterogeneity on dose profile inside a soft tissue phantom containing a bony material. PDD curves were obtained by simulation using the Monte Carlo code EGSnrc and employing Eclipse® treatment planning system algorithms (Batho, Modified Batho, Equivalent TAR and Anisotropic Analytic Algorithm) for a 15 MV photon beam and field sizes of 2×2 and 10×10 cm2. The Equivalent TAR method exhibited better agreement with Monte Carlo simulations for the 2×2 cm2 field size. The magnitude of the effect on PDD due to the bony heterogeneity for 1×1, 2×2 and 10×10 cm2 field sizes increases to 10, 5 and 3%, respectively.


  • Open Access

    Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry

    by L.A.R. da Rosa, S.C. Cardoso, L.T. Campos, V.G.L. Alves, D.V.S. Batista, A. Facure

    The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical algorithm (AAA) for a 15 MV photon beam and field sizes of 1?1,2?2,5?5 , and 10?10cm2 . Monte Carlo simulations were performed using the DOSRZnrc user code of EGSnrc. The experimental results agree with Monte Carlo simulations for all irradiation field sizes. Comparisons with Monte Carlo calculations show that the AAA algorithm provides the best simulations of PDD curves for all field sizes investigated. However, even this algorithm cannot accurately predict PDD values in the lung for field sizes of 1?1 and 2?2cm2 . An overdosage in the lung of about 40% and 20% is calculated by the AAA algorithm close to the interface soft tissue/lung for 1?1 and 2?2cm2 field sizes, respectively. It was demonstrated that differences of 100% between Monte Carlo results and the algorithms Batho, modified Batho, and equivalent TAR responses may exist inside the lung region for the 1?1cm2 field. PACS number: 87.55.kd