Zbynek Skvor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zbynek Skvor has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Karel Hoffmann
Department of Electromagnetic Field, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
13 shared publications - Pavel Staněk
Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Brehova 7, 11519 Prague, Czech Republic
3 shared publications - Jan Vancl
Dept. of Electromagnetic Field, Czech Technical University, Technická 2, 166 27 Praha, Czech Republic
2 shared publications L. Divina
2 shared publications- Petr Cerny
Dept. of Electromagnetic Field, Czech Technical University, Technická 2, 166 27 Praha, Czech Republic
2 shared publications V. Sokol
2 shared publications
Latest Publications
- 28 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (9) , 5376-5391
Evaluation of Insertion Losses of Power EMC Filters Operated in Actual Impedance Environment
Insertion losses (ILs) of power electromagnetic compatibility (EMC) filters are measured often up to the relatively high GHz region, usually by standard microwave 50- $\Omega $ vector network analyzers (VNAs) in accordance with related standards. However, the obtained $S$ -parameters do not correspond to conditions when the filters are connected to impedances of actual power sources and loads. Evaluated examples show that actual operational ILs can be significantly lower than values obtained directly from 50- $\Omega $ measurements. The presented virtual measurement method uses 50- $\Omega $ $S$ -parameter measurements and subsequently processes the data using the newly derived evaluation formulas applicable for any filter sources and loads at any frequencies. Parameters of three different particular power cables employed as practical sources and loads are measured in the frequency band from 0.1 to 10 GHz. These data are used for the proposed advanced insertion loss calculations. The results demonstrate the influences of practical cable input impedances on power filter ILs for common-mode (CM) and differential-mode (DM) transmissions, and their conversions. Related to common 50- $\Omega $ measurements, the operational IL drops can reach almost 40 dB for CM–CM transmissions, 5 dB for DM–DM transmissions, and 20 dB for CM–DM conversions. This proves that the practical information capabilities of the standard 50- $\Omega $ evaluation are really limited.
- 28 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (9) , 5376-5391
Evaluation of Insertion Losses of Power EMC Filters Operated in Actual Impedance Environment
Insertion losses (ILs) of power electromagnetic compatibility (EMC) filters are measured often up to the relatively high GHz region, usually by standard microwave 50- $\Omega $ vector network analyzers (VNAs) in accordance with related standards. However, the obtained $S$ -parameters do not correspond to conditions when the filters are connected to impedances of actual power sources and loads. Evaluated examples show that actual operational ILs can be significantly lower than values obtained directly from 50- $\Omega $ measurements. The presented virtual measurement method uses 50- $\Omega $ $S$ -parameter measurements and subsequently processes the data using the newly derived evaluation formulas applicable for any filter sources and loads at any frequencies. Parameters of three different particular power cables employed as practical sources and loads are measured in the frequency band from 0.1 to 10 GHz. These data are used for the proposed advanced insertion loss calculations. The results demonstrate the influences of practical cable input impedances on power filter ILs for common-mode (CM) and differential-mode (DM) transmissions, and their conversions. Related to common 50- $\Omega $ measurements, the operational IL drops can reach almost 40 dB for CM–CM transmissions, 5 dB for DM–DM transmissions, and 20 dB for CM–DM conversions. This proves that the practical information capabilities of the standard 50- $\Omega $ evaluation are really limited.
- 13 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (6) , 2422-2438
On the Stability of Oscillatory Modes in an Oscillator Based on a Distributed Amplifier
An in-depth investigation of oscillation modes in an oscillator based on a distributed amplifier is presented. It shows that instability problems reported in previous papers are intrinsic to the circuit nonlinear dynamics. The undesired phenomena include discontinuous jumps when continuously varying the tuning voltage, quasi-periodicity, or two incommensurable self-generated oscillations, and nonuniqueness of the mode, meaning that the same frequency can be achieved by several combinations of tuning voltages. The numerical bifurcation analysis of the circuit reveals a complicated dynamical structure that explains the mechanisms leading to the reported undesired behaviors. Special attention is paid to the presence of complicated bifurcation scenarios leading to quasi-periodic behavior and a chaotic regime. The results of this theoretical investigation are confirmed by independent numerical simulations through time-domain integration and qualitatively predict the experimental observations. Then, a stabilization procedure based on the introduction of resistors is presented, evaluating its impact on the oscillation amplitude and the uniqueness of the desired oscillation modes obtained when tuning the bias voltages.
- 13 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (6) , 2422-2438
On the Stability of Oscillatory Modes in an Oscillator Based on a Distributed Amplifier
An in-depth investigation of oscillation modes in an oscillator based on a distributed amplifier is presented. It shows that instability problems reported in previous papers are intrinsic to the circuit nonlinear dynamics. The undesired phenomena include discontinuous jumps when continuously varying the tuning voltage, quasi-periodicity, or two incommensurable self-generated oscillations, and nonuniqueness of the mode, meaning that the same frequency can be achieved by several combinations of tuning voltages. The numerical bifurcation analysis of the circuit reveals a complicated dynamical structure that explains the mechanisms leading to the reported undesired behaviors. Special attention is paid to the presence of complicated bifurcation scenarios leading to quasi-periodic behavior and a chaotic regime. The results of this theoretical investigation are confirmed by independent numerical simulations through time-domain integration and qualitatively predict the experimental observations. Then, a stabilization procedure based on the introduction of resistors is presented, evaluating its impact on the oscillation amplitude and the uniqueness of the desired oscillation modes obtained when tuning the bias voltages.
- 25 October 2022
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 33 (6) , 267-276
Time Multiplexing of Currents for Magnetic Particle Inspection
This article concerns magnetization methods for detecting arbitrary oriented defects by magnetic particle inspection. The authors propose a new method of magnetization with omnidirectional detection ability requiring only a single-channel DC or AC power supply. The detection of all defects by the new method can be achieved during a single testing (spraying) cycle.
- 25 October 2022
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 33 (6) , 267-276
Time Multiplexing of Currents for Magnetic Particle Inspection
This article concerns magnetization methods for detecting arbitrary oriented defects by magnetic particle inspection. The authors propose a new method of magnetization with omnidirectional detection ability requiring only a single-channel DC or AC power supply. The detection of all defects by the new method can be achieved during a single testing (spraying) cycle.
- 27 April 2022
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 38 (1) , 34-44
Impact of crest factor on indication quality in the magnetic particle inspection process
Magnetic particle inspection is a well-established industrial process of quality control. The ISO standard for magnetic particle inspection requires control of the crest factor and recommends avoiding current waveforms with a crest factor larger than three without documented evidence of detection effectiveness. Modern test bench units often use thyristor regulation of the magnetization current, which enables broad control ranges to generate an adequate magnetic field. A possible method of evaluation of magnetic field for magnetic particle inspection is to quantify the force effect on a detection particle. The cumulative force effect can be expressed as an impulse of force on a detection particle. The method of evaluation by an impulse of force implies that crest factor does not have a major effect if the impulse is controlled. This work contains a theoretical analysis of force in magnetic field generated by thyristor controlled currents. In the experimental part a comparison of indications generated by magnetic fields of different crest factorsis performed. The results of the experiment are in line with the theoretical analysis and show that it is the impulse that plays the major role in the formation of an indication and not crest factor.
- 27 April 2022
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 38 (1) , 34-44
Impact of crest factor on indication quality in the magnetic particle inspection process
Magnetic particle inspection is a well-established industrial process of quality control. The ISO standard for magnetic particle inspection requires control of the crest factor and recommends avoiding current waveforms with a crest factor larger than three without documented evidence of detection effectiveness. Modern test bench units often use thyristor regulation of the magnetization current, which enables broad control ranges to generate an adequate magnetic field. A possible method of evaluation of magnetic field for magnetic particle inspection is to quantify the force effect on a detection particle. The cumulative force effect can be expressed as an impulse of force on a detection particle. The method of evaluation by an impulse of force implies that crest factor does not have a major effect if the impulse is controlled. This work contains a theoretical analysis of force in magnetic field generated by thyristor controlled currents. In the experimental part a comparison of indications generated by magnetic fields of different crest factorsis performed. The results of the experiment are in line with the theoretical analysis and show that it is the impulse that plays the major role in the formation of an indication and not crest factor.
- 2 August 2019
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 38 (3) , 1-6
Automated Magnetic Field Evaluation for Magnetic Particle Inspection by Impulse
- 2 August 2019
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 38 (3) , 1-6
Automated Magnetic Field Evaluation for Magnetic Particle Inspection by Impulse
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Microstrip open — Problematic calibration standard
Microstrip open end (Open) applied as a calibration standard in frequency band up to 26 GHz was analyzed using CST Microwave Studio (CST). Arlon CuClad 233 with thickness 0.508mm was used for simulations. Different lengths of the microstrip lines in front of the Open were considered. Significant influence of the radiated field and the length of the microstrip line on the reflection coefficient magnitude of the standard in the order 0.01 was discovered. Physical explanation of the phenomenon is given.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Microstrip open — Problematic calibration standard
Microstrip open end (Open) applied as a calibration standard in frequency band up to 26 GHz was analyzed using CST Microwave Studio (CST). Arlon CuClad 233 with thickness 0.508mm was used for simulations. Different lengths of the microstrip lines in front of the Open were considered. Significant influence of the radiated field and the length of the microstrip line on the reflection coefficient magnitude of the standard in the order 0.01 was discovered. Physical explanation of the phenomenon is given.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Microwave interferometric method for metal sheet thickness measurement
A new microwave method capable of contactless thickness measurement of metal sheets with high resolution has been proposed. First experimental results in X-band are reported. The method is based on precise interferometric phase evaluation of a signal reflected step by step from two surfaces of a metal sheet whose thickness is to be measured. This is achieved using interference between the reflected and reference signals. Micrometer resolution at 10 GHz can be expected.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Microwave interferometric method for metal sheet thickness measurement
A new microwave method capable of contactless thickness measurement of metal sheets with high resolution has been proposed. First experimental results in X-band are reported. The method is based on precise interferometric phase evaluation of a signal reflected step by step from two surfaces of a metal sheet whose thickness is to be measured. This is achieved using interference between the reflected and reference signals. Micrometer resolution at 10 GHz can be expected.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Precise microwave measurement of liquid level
A simple interferometric waveguide setup has been developed, enabling for precise distance measurement of liquid level. Total reflection from the liquid surface is not necessary. For the most common case of lossy liquids, reflection phase must be determined properly. This may be accomplished by the use of a waveguide short for calibration. The setup was tested in measurement of water level. Resolution of the order of micrometers was achieved in X-band.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Precise microwave measurement of liquid level
A simple interferometric waveguide setup has been developed, enabling for precise distance measurement of liquid level. Total reflection from the liquid surface is not necessary. For the most common case of lossy liquids, reflection phase must be determined properly. This may be accomplished by the use of a waveguide short for calibration. The setup was tested in measurement of water level. Resolution of the order of micrometers was achieved in X-band.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Contactless distance measurement method
A new method capable of contactless distance measurement with high resolution has been proposed. The method is intended to measure distance differences smaller than one half of a wavelength. First experimental results are reported. The method is based on precise phase evaluation of signal reflected by the surface whose distance is measured. This is achieved using interference between the reflected and reference signals. Micrometer resolution at 10 GHz can be expected.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Contactless distance measurement method
A new method capable of contactless distance measurement with high resolution has been proposed. The method is intended to measure distance differences smaller than one half of a wavelength. First experimental results are reported. The method is based on precise phase evaluation of signal reflected by the surface whose distance is measured. This is achieved using interference between the reflected and reference signals. Micrometer resolution at 10 GHz can be expected.
- 23 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 58 (9) , 2518
Authors' reply
In order to obtain results in the above paper, we used five parameters. According to our statement that inserting a transmission line between the scalar analyzer and a perturbation two-port would not affect measured values, we imposed the condition that the argument of S11 is zero during calibration and data correction. Any other real value would do the same job.
- 23 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 58 (9) , 2518
Authors' reply
In order to obtain results in the above paper, we used five parameters. According to our statement that inserting a transmission line between the scalar analyzer and a perturbation two-port would not affect measured values, we imposed the condition that the argument of S11 is zero during calibration and data correction. Any other real value would do the same job.