Pavel Staněk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pavel Staněk has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Zbynek Skvor
Department of Electromagnetic Field, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
3 shared publications - L. Tomasek
Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University, Brehova 78/7, 115 19 Prague 1, Czech Republic
2 shared publications - A. A. Kostina
Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Brehova 7, 11519 Prague, Czech Republic
1 shared publication A. Ilg
Physik-Institut, University of Zurich, Winterthurerstrasse 190, 8057 Zurich, Switzerland
1 shared publication- A. Lorenzetti
Universität Zürich
1 shared publication - Ajit Kumar
Université de Strasbourg, CNRS, IPHC UMR 7178, F-67000 Strasbourg, France
1 shared publication
Latest Publications
- Open Access
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03033
Performance studies of the CE-65v2 MAPS prototype structure
With the next upgrade of the ALICE inner tracking system (ITS3) as its primary focus, a set of small MAPS test structures have been developed in the 65 nm TPSCo CMOS process. The CE-65 focuses on the characterisation of the analogue charge collection properties of this technology. The latest iteration, the CE-65v2, was produced in different processes (Standard, with a low-dose n-type blanket, and blanket with gap between pixels), pixel pitches (15, 18, 22.5 µm) and pixel arrangements (square or staggered). The comparatively large pixel array size of 48×24 pixels in CE-65v2 allows the uniformity of the pixel response to be studied, among other benefits. The CE-65v2 chip was characterised in a test beam at the CERN SPS. A first analysis showed that hit efficiencies of ≥ 99% and spatial resolution better than 5 µm can be achieved for all pitches and process variants. For the Standard process, thanks to larger charge sharing, even spatial resolutions below 3 µm are reached, in line with vertex detector requirements for the FCC-ee. This contribution further investigates the data collected at the SPS test beam. Thanks to the large sensor size and efficient data collection, a large amount of statistics was collected, which allows for detailed in-pixel studies to see the efficiency and spatial resolution as a function of the hit position within the pixels. Again, different pitches and process variants are compared.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03033
Open AccessPerformance studies of the CE-65v2 MAPS prototype structure
With the next upgrade of the ALICE inner tracking system (ITS3) as its primary focus, a set of small MAPS test structures have been developed in the 65 nm TPSCo CMOS process. The CE-65 focuses on the characterisation of the analogue charge collection properties of this technology. The latest iteration, the CE-65v2, was produced in different processes (Standard, with a low-dose n-type blanket, and blanket with gap between pixels), pixel pitches (15, 18, 22.5 µm) and pixel arrangements (square or staggered). The comparatively large pixel array size of 48×24 pixels in CE-65v2 allows the uniformity of the pixel response to be studied, among other benefits. The CE-65v2 chip was characterised in a test beam at the CERN SPS. A first analysis showed that hit efficiencies of ≥ 99% and spatial resolution better than 5 µm can be achieved for all pitches and process variants. For the Standard process, thanks to larger charge sharing, even spatial resolutions below 3 µm are reached, in line with vertex detector requirements for the FCC-ee. This contribution further investigates the data collected at the SPS test beam. Thanks to the large sensor size and efficient data collection, a large amount of statistics was collected, which allows for detailed in-pixel studies to see the efficiency and spatial resolution as a function of the hit position within the pixels. Again, different pitches and process variants are compared.
- Open Access
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03036
The data acquisition system for the PANDA Micro-Vertex Detector
The PANDA (antiProton ANnihilation at DArmstadt) experiment will study the strong interaction in annihilation reactions between an antiproton beam and a stationary cluster jet target. The PANDA detector will be composed of several sub-detectors designed for tracking, particle identification and calorimetry. The Micro-Vertex Detector (MVD) is the innermost part of the tracking system surrounding the interaction region, which is designed for precise vertex and tracking detection. It consists of silicon pixel and double-sided microstrip detectors. For the readout of the microstrip sensors an ASIC called ToASt (Torino Asic for Strip readout) is being developed in 0.11 μm CMOS technology at INFN Turin. The ASIC takes advantage of both Time-over-Threshold and Time-of-Arrival methods to accurately measure the event's energy and timestamp. To sustain the acquisition of the microstrip sensors a MDC (Module Data Concentrator) ASIC is under development at KIT. Up to eight ToASt front-ends' data streams are multiplexed, read out and processed by one MDC. The data of several MDCs are collected and processed by the off-detector readout card MMB (MVD Multiplexer Board), also under development at KIT. The processed data is then transferred via 100 GbE optical links to the computing nodes. The ToASt chips have been integrated with the FPGA implementation of the MDC to form the first fully functional detector module. Beam tests have been performed at the COSY facility in Jülich. This paper focuses on the design of MDC ASIC and MMB board, the integration with the ToASt and presents preliminary beam test results.
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03036
Open AccessThe data acquisition system for the PANDA Micro-Vertex Detector
The PANDA (antiProton ANnihilation at DArmstadt) experiment will study the strong interaction in annihilation reactions between an antiproton beam and a stationary cluster jet target. The PANDA detector will be composed of several sub-detectors designed for tracking, particle identification and calorimetry. The Micro-Vertex Detector (MVD) is the innermost part of the tracking system surrounding the interaction region, which is designed for precise vertex and tracking detection. It consists of silicon pixel and double-sided microstrip detectors. For the readout of the microstrip sensors an ASIC called ToASt (Torino Asic for Strip readout) is being developed in 0.11 μm CMOS technology at INFN Turin. The ASIC takes advantage of both Time-over-Threshold and Time-of-Arrival methods to accurately measure the event's energy and timestamp. To sustain the acquisition of the microstrip sensors a MDC (Module Data Concentrator) ASIC is under development at KIT. Up to eight ToASt front-ends' data streams are multiplexed, read out and processed by one MDC. The data of several MDCs are collected and processed by the off-detector readout card MMB (MVD Multiplexer Board), also under development at KIT. The processed data is then transferred via 100 GbE optical links to the computing nodes. The ToASt chips have been integrated with the FPGA implementation of the MDC to form the first fully functional detector module. Beam tests have been performed at the COSY facility in Jülich. This paper focuses on the design of MDC ASIC and MMB board, the integration with the ToASt and presents preliminary beam test results.
- 25 October 2022
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 33 (6) , 267-276
Time Multiplexing of Currents for Magnetic Particle Inspection
This article concerns magnetization methods for detecting arbitrary oriented defects by magnetic particle inspection. The authors propose a new method of magnetization with omnidirectional detection ability requiring only a single-channel DC or AC power supply. The detection of all defects by the new method can be achieved during a single testing (spraying) cycle.
- 25 October 2022
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 33 (6) , 267-276
Time Multiplexing of Currents for Magnetic Particle Inspection
This article concerns magnetization methods for detecting arbitrary oriented defects by magnetic particle inspection. The authors propose a new method of magnetization with omnidirectional detection ability requiring only a single-channel DC or AC power supply. The detection of all defects by the new method can be achieved during a single testing (spraying) cycle.
- 27 April 2022
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 38 (1) , 34-44
Impact of crest factor on indication quality in the magnetic particle inspection process
Magnetic particle inspection is a well-established industrial process of quality control. The ISO standard for magnetic particle inspection requires control of the crest factor and recommends avoiding current waveforms with a crest factor larger than three without documented evidence of detection effectiveness. Modern test bench units often use thyristor regulation of the magnetization current, which enables broad control ranges to generate an adequate magnetic field. A possible method of evaluation of magnetic field for magnetic particle inspection is to quantify the force effect on a detection particle. The cumulative force effect can be expressed as an impulse of force on a detection particle. The method of evaluation by an impulse of force implies that crest factor does not have a major effect if the impulse is controlled. This work contains a theoretical analysis of force in magnetic field generated by thyristor controlled currents. In the experimental part a comparison of indications generated by magnetic fields of different crest factorsis performed. The results of the experiment are in line with the theoretical analysis and show that it is the impulse that plays the major role in the formation of an indication and not crest factor.
- 27 April 2022
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 38 (1) , 34-44
Impact of crest factor on indication quality in the magnetic particle inspection process
Magnetic particle inspection is a well-established industrial process of quality control. The ISO standard for magnetic particle inspection requires control of the crest factor and recommends avoiding current waveforms with a crest factor larger than three without documented evidence of detection effectiveness. Modern test bench units often use thyristor regulation of the magnetization current, which enables broad control ranges to generate an adequate magnetic field. A possible method of evaluation of magnetic field for magnetic particle inspection is to quantify the force effect on a detection particle. The cumulative force effect can be expressed as an impulse of force on a detection particle. The method of evaluation by an impulse of force implies that crest factor does not have a major effect if the impulse is controlled. This work contains a theoretical analysis of force in magnetic field generated by thyristor controlled currents. In the experimental part a comparison of indications generated by magnetic fields of different crest factorsis performed. The results of the experiment are in line with the theoretical analysis and show that it is the impulse that plays the major role in the formation of an indication and not crest factor.
- 2 August 2019
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 38 (3) , 1-6
Automated Magnetic Field Evaluation for Magnetic Particle Inspection by Impulse
- 2 August 2019
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 38 (3) , 1-6
Automated Magnetic Field Evaluation for Magnetic Particle Inspection by Impulse