Sotirios I. Nanou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sotirios I. Nanou has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Stavros A. Papathanassiou
9 shared publications- Georgios N. Psarros
School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
3 shared publications Stavros Papathanassiou
School of Electrical and Computer Engineering, National Technical University of Athens (NTUA), Greece
3 shared publicationsApostolos G. Papakonstantinou
1 shared publicationCostas D. Vournas
1 shared publication- Georgios Patsakis
Industrial Engineering and Operations Research, University of California Berkeley, 1438 Berkeley, California United States 94720
1 shared publication
Latest Publications
- 1 February 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 229
Optimal dispatch of BESS-fed virtual power lines under transmission congestion and bulk renewable generation
- 1 February 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 229
Optimal dispatch of BESS-fed virtual power lines under transmission congestion and bulk renewable generation
- 1 January 2018
- Published by Elsevier in Renewable Energy
- Vol. 115, 338-352
Generation scheduling in non-interconnected islands with high RES penetration
- 1 January 2018
- Published by Elsevier in Renewable Energy
- Vol. 115, 338-352
Generation scheduling in non-interconnected islands with high RES penetration
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28, 1-5
Fault ride-through response of VSC-HVDC links operating in island systems with parallel AC interconnectors
The main objective of this paper is to present a suitable dynamic model for a high-voltage dc link based on voltage source converters (VSC-HVDC), with fault ride-through (FRT) capability, suitable for dynamic studies dealing with island interconnection projects where external ac links are also present. The analysis provides insight to the expected response of dc and ac interconnectors operating in parallel, along with onsite conventional generation, under both balanced and unbalanced voltage dips. The presented model includes the necessary converter control features which provide immunity to voltage dips and regulation of output current. The study-case system selected in this work corresponds to the planning for the future interconnection of Crete island to the Greek mainland system with parallel ac and dc interconnectors. Time-domain simulations are performed in Matlab/Simulink, confirming the satisfactory response obtained by the developed model.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28, 1-5
Fault ride-through response of VSC-HVDC links operating in island systems with parallel AC interconnectors
The main objective of this paper is to present a suitable dynamic model for a high-voltage dc link based on voltage source converters (VSC-HVDC), with fault ride-through (FRT) capability, suitable for dynamic studies dealing with island interconnection projects where external ac links are also present. The analysis provides insight to the expected response of dc and ac interconnectors operating in parallel, along with onsite conventional generation, under both balanced and unbalanced voltage dips. The presented model includes the necessary converter control features which provide immunity to voltage dips and regulation of output current. The study-case system selected in this work corresponds to the planning for the future interconnection of Crete island to the Greek mainland system with parallel ac and dc interconnectors. Time-domain simulations are performed in Matlab/Simulink, confirming the satisfactory response obtained by the developed model.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Generic average-value modeling of MMC-HVDC links considering submodule capacitor dynamics
The main objective of this paper is to propose a generic average-value model for the state-of-the-art modular multilevel converter (MMC) topology used in commercial high voltage dc transmission (HVDC) applications. The proposed model does not rely solely on the fundamental frequency modeling approach, but it also takes into account the expected dynamic behavior of submodule capacitors connected in series in each arm of the actual MMC circuit topology. The model includes six controlled voltage sources, connected in each converter arm, which are governed by the dynamics of an equivalent submodule capacitor, reproducing the expected voltage ripple, as well as the circulating currents induced inside each converter arm. To evaluate the accuracy of the proposed average-value MMC model, a comparative assessment is performed against the detailed switching model, via time-domain simulations in Matlab/Simulink, under normal operation and in the presence of grid faults.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Generic average-value modeling of MMC-HVDC links considering submodule capacitor dynamics
The main objective of this paper is to propose a generic average-value model for the state-of-the-art modular multilevel converter (MMC) topology used in commercial high voltage dc transmission (HVDC) applications. The proposed model does not rely solely on the fundamental frequency modeling approach, but it also takes into account the expected dynamic behavior of submodule capacitors connected in series in each arm of the actual MMC circuit topology. The model includes six controlled voltage sources, connected in each converter arm, which are governed by the dynamics of an equivalent submodule capacitor, reproducing the expected voltage ripple, as well as the circulating currents induced inside each converter arm. To evaluate the accuracy of the proposed average-value MMC model, a comparative assessment is performed against the detailed switching model, via time-domain simulations in Matlab/Simulink, under normal operation and in the presence of grid faults.
- 3 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (1) , 447-454
Frequency Control of Island VSC-HVDC Links Operating in Parallel With AC Interconnectors and Onsite Generation
The main scope of this paper is to propose a suitable frequency control scheme for high-voltage dc-links (HVDC) based on voltage source converters (VSCs), operating in island systems with on-site conventional generation and external ac interconnectors. The proposed droop-type and inertia emulator is built upon the power synchronization control (PSC) concept, where grid synchronization is achieved without the need of a dedicated synchronization unit. The dynamics of the proposed PSC-based scheme are assessed both in frequency and time domain, utilizing a realistic study-case system, which corresponds to the current planning for the interconnection of Crete to the Greek mainland system, involving ac and dc interconnectors operating in parallel with conventional local thermal units. To demonstrate the benefits offered by the proposed controller in the context of frequency response, a detailed average value model is developed for the VSC-HVDC link in MATLAB/Simulink, where severe contingencies are simulated, such as the sudden loss of the external ac interconnector or local generation, leading from mainland grid-connected to islanded operation.
- 3 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (1) , 447-454
Frequency Control of Island VSC-HVDC Links Operating in Parallel With AC Interconnectors and Onsite Generation
The main scope of this paper is to propose a suitable frequency control scheme for high-voltage dc-links (HVDC) based on voltage source converters (VSCs), operating in island systems with on-site conventional generation and external ac interconnectors. The proposed droop-type and inertia emulator is built upon the power synchronization control (PSC) concept, where grid synchronization is achieved without the need of a dedicated synchronization unit. The dynamics of the proposed PSC-based scheme are assessed both in frequency and time domain, utilizing a realistic study-case system, which corresponds to the current planning for the interconnection of Crete to the Greek mainland system, involving ac and dc interconnectors operating in parallel with conventional local thermal units. To demonstrate the benefits offered by the proposed controller in the context of frequency response, a detailed average value model is developed for the VSC-HVDC link in MATLAB/Simulink, where severe contingencies are simulated, such as the sudden loss of the external ac interconnector or local generation, leading from mainland grid-connected to islanded operation.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Evaluation of control schemes for island VSC-HVDC links operating in parallel with AC interconnectors
The main objective of this paper is to comparatively assess alternative control schemes for high voltage dc (HVDC) links based on voltage source converters (VSCs), adapted for island systems with mixed ac and dc interconnectors operating in parallel. A suitable study-case system is selected, which corresponds to the planning for the future interconnection of Crete island to the Greek mainland system, where a multitude of generating units on the island, i.e. ac and dc interconnectors along with conventional local thermal units, is expected to operate in parallel. Particular emphasis is placed on the ability of the island VSC to maintain synchronism under severe contingency events, such as following the sudden loss of the external ac interconnector or local thermal plants, which lead the VSCs to transition from grid-connected to grid-forming operation. A detailed average value model is developed for the VSC-HVDC link in Matlab/Simulink, where various disturbances are simulated.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Evaluation of control schemes for island VSC-HVDC links operating in parallel with AC interconnectors
The main objective of this paper is to comparatively assess alternative control schemes for high voltage dc (HVDC) links based on voltage source converters (VSCs), adapted for island systems with mixed ac and dc interconnectors operating in parallel. A suitable study-case system is selected, which corresponds to the planning for the future interconnection of Crete island to the Greek mainland system, where a multitude of generating units on the island, i.e. ac and dc interconnectors along with conventional local thermal units, is expected to operate in parallel. Particular emphasis is placed on the ability of the island VSC to maintain synchronism under severe contingency events, such as following the sudden loss of the external ac interconnector or local thermal plants, which lead the VSCs to transition from grid-connected to grid-forming operation. A detailed average value model is developed for the VSC-HVDC link in Matlab/Simulink, where various disturbances are simulated.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21, 1-5
Operating reserve scheduling for island systems with parallel AC-DC interconnectors: The case of Crete
In this paper, a unit commitment model is presented for island systems connected to the mainland through parallel ac and dc interconnectors. The main goal is to determine the hourly economic dispatch of all generating units, leading to maximum penetration of renewables and minimization of total operating costs. The analysis is performed in GAMS using the Mixed Integer Linear Programming (MILP) method, where all essential constraints, such as the required operating reserves, transmission capacity constraints and technical limits of the generating units and interconnectors, are properly accounted for. Crete is selected as the study-case system, whose interconnection to the Greek mainland is currently being planned with parallel ac and dc links.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21, 1-5
Operating reserve scheduling for island systems with parallel AC-DC interconnectors: The case of Crete
In this paper, a unit commitment model is presented for island systems connected to the mainland through parallel ac and dc interconnectors. The main goal is to determine the hourly economic dispatch of all generating units, leading to maximum penetration of renewables and minimization of total operating costs. The analysis is performed in GAMS using the Mixed Integer Linear Programming (MILP) method, where all essential constraints, such as the required operating reserves, transmission capacity constraints and technical limits of the generating units and interconnectors, are properly accounted for. Crete is selected as the study-case system, whose interconnection to the Greek mainland is currently being planned with parallel ac and dc links.
- 1 November 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 140, 925-932
Evaluation of an enhanced power dispatch control scheme for multi-terminal HVDC grids using Monte-Carlo simulation
- 1 November 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 140, 925-932
Evaluation of an enhanced power dispatch control scheme for multi-terminal HVDC grids using Monte-Carlo simulation
- 19 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 31 (6) , 5042-5050
Grid Code Compatibility of VSC-HVDC Connected Offshore Wind Turbines Employing Power Synchronization Control
This paper presents an alternative control scheme for offshore wind turbines (WTs) connected to the mainland grid through high voltage dc (HVDC) links based on voltage source converters (VSCs). The proposed WT controller inherently provides rapid droop-type frequency response, without the need to implement an additional WT frequency controller. A coordinated control approach is proposed between the WT and HVDC controllers in order to achieve fault ride-through (FRT) and frequency response capabilities, relying solely on offshore frequency modulation. To demonstrate the FRT capability of the VSC-HVDC link, a detailed EMT-type model is first developed in Matlab/Simulink, where onshore grid faults are tested. Then, the offshore wind farm is connected to a study case system in order to assess the contribution of the VSC-HVDC link to frequency regulation, by exploiting the proposed WT controller along with the communication capability between the two HVDC VSCs.
- 19 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 31 (6) , 5042-5050
Grid Code Compatibility of VSC-HVDC Connected Offshore Wind Turbines Employing Power Synchronization Control
This paper presents an alternative control scheme for offshore wind turbines (WTs) connected to the mainland grid through high voltage dc (HVDC) links based on voltage source converters (VSCs). The proposed WT controller inherently provides rapid droop-type frequency response, without the need to implement an additional WT frequency controller. A coordinated control approach is proposed between the WT and HVDC controllers in order to achieve fault ride-through (FRT) and frequency response capabilities, relying solely on offshore frequency modulation. To demonstrate the FRT capability of the VSC-HVDC link, a detailed EMT-type model is first developed in Matlab/Simulink, where onshore grid faults are tested. Then, the offshore wind farm is connected to a study case system in order to assess the contribution of the VSC-HVDC link to frequency regulation, by exploiting the proposed WT controller along with the communication capability between the two HVDC VSCs.
- Open Access
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 9 (8) , 882-891
Evaluation of a communication‐based fault ride‐through scheme for offshore wind farms connected through high‐voltage DC links based on voltage source converter
Offshore wind farms connected to the mainland through high‐voltage DC links based on voltage source converters (VSC‐HVDC) are subject to grid code requirements, such as fault ride‐through (FRT) capability and dynamic voltage support. To address the challenge of FRT capability, sophisticated control strategies are required, capable of handling the power imbalance between the two interconnection ends during onshore grid faults. Τhis study proposes an FRT method which combines a de‐loading control strategy for the offshore wind turbines, utilising the communication infrastructure of the VSC‐HVDC system, with a DC chopper to dissipate the power surplus that cannot be effectively curtailed via the communication link. The impact of communication system latency on the expected FRT response and the required rating of the DC chopper is investigated using a linearised small‐signal model introduced in this study, whose results are validated against time‐domain simulations using detailed electromagnetic transient‐type models for the entire system. It is concluded that the required rating of chopper resistors can be substantially reduced when existing communication capabilities are exploited, even in the presence of relatively high communication delays.
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 9 (8) , 882-891
Open AccessEvaluation of a communication‐based fault ride‐through scheme for offshore wind farms connected through high‐voltage DC links based on voltage source converter
Offshore wind farms connected to the mainland through high‐voltage DC links based on voltage source converters (VSC‐HVDC) are subject to grid code requirements, such as fault ride‐through (FRT) capability and dynamic voltage support. To address the challenge of FRT capability, sophisticated control strategies are required, capable of handling the power imbalance between the two interconnection ends during onshore grid faults. Τhis study proposes an FRT method which combines a de‐loading control strategy for the offshore wind turbines, utilising the communication infrastructure of the VSC‐HVDC system, with a DC chopper to dissipate the power surplus that cannot be effectively curtailed via the communication link. The impact of communication system latency on the expected FRT response and the required rating of the DC chopper is investigated using a linearised small‐signal model introduced in this study, whose results are validated against time‐domain simulations using detailed electromagnetic transient‐type models for the entire system. It is concluded that the required rating of chopper resistors can be substantially reduced when existing communication capabilities are exploited, even in the presence of relatively high communication delays.