Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Bryan Ormond has a total of 109 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the Filtration and Breathability of Commercial Respiratory Devices for Potential Wildland and Wildland-Urban Interface Firefighting Operations

    by Melissa Armistead, Hannah Kirk, Emily Lowder, Warren Jasper, Cassandra Kwon, George Broyles, Matt Rahn, Kelcey Stricker, Rick Swan, R. Bryan Ormond

    Wildland firefighters are facing frequent and extreme wildfire behavior, placing them at greater risk for concentrated and cumulative inhalation exposures over each fire season. This study evaluated commercially available respirators and nontraditional respiratory devices to assess their potential use in wildland/wildland-urban interface (WUI) operations. Filter testing was conducted to identify devices with potential as barrier and/or protective face coverings under current respiratory standards. An animatronic headform was used to evaluate these devices alongside certified respirators through a simulated fit test to measure total filtration efficacy (TFE) and differential pressure (ΔP) at two breathing workloads. From these evaluations, the quality factor (qf) on the headform was predicted to be the most realistic measure of performance. Ultimately, no device was able to maintain qf ≥ 14 kPa–1 with TFE ≥ 50% and ΔP ≤ 5 mm H2O at both light and moderate workloads. Given the arduous workloads typical of wildland/WUI firefighting, this raises concerns about potential applications in the field. However, several of these devices maintained TFE ≥ 50% that could offer short-term solutions to help reduce exposure with intermittent use. More research is needed to ensure these proposed measures of TFE and ΔP are feasible without imposing a significant physiological burden.

  • Open Access

    Volatile per- and polyfluoroalkyl substances (PFAS) and other semi-volatile organic chemicals in indoor air of fire stations: the influence of gear storage conditions

    by Heather M. Stapleton, Nicholas J. Herkert, Duncan Hay, Kate Hoffman, R. Bryan Ormond

    Previous studies have examined firefighters' exposure to chemicals associated with fire calls and per- and polyfluoroalkyl substances (PFAS); however, little attention has been given to exposures in the fire station itself. This study measured volatile PFAS and other semi-volatile organic chemicals (SVOCs) in indoor air of fire stations in North Carolina, USA. Eleven fire stations and one turnout gear cleaning and supply station across three different counties in North Carolina were sampled between May and September of 2024. In each station, air was sampled both in the day room (area where firefighters congregate during the day) and in the area where the turnout gear was stored. Samples were extracted and analyzed for 14 different PFAS and 120 different SVOCs using GC-HRMS. The most frequently detected chemicals were PFASs, combustion byproducts, and phthalates. 8 : 2 FTOH was measured at the highest level at 1067 ng m−3. Total SVOC levels, and particularly PFAS, were significantly higher in closed rooms with turnout gear relative to storage areas open to the apparatus bay or the day room. Exposure estimates indicate that some turnout gear storage areas may pose a health risk for PFOA based on inhalation exposure to 8 : 2 FTOH and conversion to PFOA in the blood. These data highlight a need to consider station design and ventilation needs to mitigate risks.

  • Open Access

    Development of an animatronic headform test method for determining the efficacy of medical masks and barrier face coverings—part 2: validation study

    by Melissa Armistead, Didem Kiryaman, Anuja Dandekar, Mark Gaskill, Marc Mathews, Arjunsing Girase, R. Bryan Ormond

    There is a need for a realistic method to evaluate the performance of barrier face coverings and medical masks in the wake of growing respiratory concerns among the general public. In this study, the previous animatronic headform test method was optimized to evaluate the total filtration efficacy and breathing resistance of 12 products during a 10-minute simulated fit test. These products included three respiratory devices, three medical masks, and six barrier face covering styles. The revised method was able to differentiate between products with total filtration efficacies ranging from 14% to 93%, down to a difference in means of 2% at 0.3 μm optical diameter. The impact of fit was illustrated by the increase in total filtration efficacy and breathing resistance across all three medical masks when the ear loops were tightened. The coefficient of variation for each product fell below 20% at 0.3 μm optical diameter, indicating good measurement stability. A second operator conducted an intra-lab validation to determine the method's reliability. This analysis confirmed the improved repeatability and reproducibility of the headform test method, which was shown to effectively evaluate the total filtration efficacy of respiratory products as a system in a controlled laboratory setting. However, more research is needed to improve the sensitivity of the breathing resistance measurements. Comparison to the ASTM F3502-21 Standard Specification for Barrier Face Coverings highlighted the differences between evaluating these products as a sealed system or as they are intended to be worn, with an overall decrease in total filtration efficiency and breathing resistance due to leakage when evaluated on the headform.

  • Open Access

    Development of an animatronic headform test method for determining the efficacy of medical masks and barrier face coverings—part 1: total filtration efficacy

    by Melissa Armistead, Anuja Dandekar, Marc Mathews, Madilynn Smith, Mark Gaskill, Arjunsing Girase, R. Bryan Ormond

    The effectiveness of face coverings against respiratory viruses is crucial for public health but often lacks realistic performance assessments of protection and comfort. In this study, a system-level test method was developed using an animatronic headform to incorporate fit and dynamic wear into the assessment of total filtration efficacy of medical masks and barrier face coverings. Six commercially available products were evaluated, including an N95 respirator as the control. Total filtration efficacy was calculated from differential particle counts recorded inside and outside of face coverings each minute. The baseline method was able to statistically differentiate between products to a difference in means of 5% at a particle size of 0.3 μm optical diameter. The 16 and 28 L/min sinusoidal flow rates significantly impacted total filtration efficacy, as did the influence of headform movement and duration of wear for select products. There were statistical differences between operators at both flow rates for the KN95 and surgical style masks that were difficult to don consistently, highlighting the variability in performance due to fit. However, the product type remained the most significant cause of variance in the method at 66.10%, demonstrating that the headform test method was able to repeatedly and reproducibly evaluate the efficacy of various face coverings. Furthermore, there were significant decreases in filtration when the facepiece was not sealed properly due to poor fit. This highlights the importance of evaluating these source control devices, including barrier face coverings and public use of medical masks, as they are intended to be worn to incorporate their fit into the reported results.


  • Open Access

    Impact of Skin Decontamination Wipe Solutions on the Percutaneous Absorption of Polycyclic Aromatic Hydrocarbons

    by Chandler Probert, R. Bryan Ormond, Ronald E. Baynes

    Firefighter occupational exposures were categorized as a class 1 (known) carcinogen by the International Agency for Research on Cancer in 2022. As a result, firefighters have become heavily focused on identifying effective and easy to implement decontamination strategies to reduce their chemical exposures. Skin decontamination using wipes post-exposure is one decontamination strategy that every firefighter has available to them. However, firefighters have expressed concerns over the ingredients in the wipe solution increasing dermal absorption. The goal of this study was to determine if the ingredients in skin decontamination wipe solution had any enhancement effect on the dermal absorption of phenanthrene. To determine any enhancement effects, the additive solution of four skin decontamination wipe products was applied to porcine skin 15 min after chemical dosing. The absorption of phenanthrene was tested in vitro using a flow-through diffusion cell system over eight hours. The wipe solution effects on dermal absorption were determined by measuring multiple absorption characteristics including cumulative absorption (µg/cm2), absorption efficiency (% dose absorbed), lag time (minutes), flux (µg/cm2/h), diffusivity (cm2/h), and permeability (cm/h). No penetration enhancement effects were observed in any of the skin decontamination wipe solutions tested; rather, all wipe solutions decreased the absorption of phenanthrene. Slight differences in cumulative absorption among two pairings of skin decontamination wipe solutions, wipes 1 and 3 vs. wipes 2 and 4, were observed, indicating that some ingredients may impact dermal absorption. These findings show that firefighters should continue using skin decontamination wipes to reduce their dermal exposures to fireground contaminants with little concern of increasing the absorption of phenanthrene.


  • Open Access

    Skin Permeability of Perfluorocarboxylic Acids Using Flow-Through Diffusion on Porcine Skin

    by Andrew Stephen Hall, Ronald Baynes, Laura M. Neumann, Howard I. Maibach, R. Bryan Ormond

    Per- and polyfluoroalkyl substances (PFAS) are found in a variety of places including cosmetics, rain jackets, dust, and water. PFAS have also been applied to occupational gear to protect against water and oils. However, PFAS have been identified as immunosuppressants and perfluorooctanoic acid (PFOA), a specific PFAS, has been identified as carcinogenic. Since there is a risk for dermal exposure to these compounds, there is a need to characterize their dermal absorption. Using in vitro flow-through diffusion, skin permeabilities were determined for 14C-labeled perfluorooctanoic acid (PFOA), perfluorohexanoic acid (PFHxA), and perfluorobutanoic acid (PFBA) using porcine skin. Tests were conducted over 8 h with either acetone or artificial perspirant as the vehicle. PFBA was found to have greater permeability than PFHxA, likely due to having a smaller molecular weight. The dosing vehicle did not appear to impact permeability rates but impacted the disposition through the skin model. While these PFAS compounds showed a low permeability rate through the skin membranes, they can stay in the skin, acting as a reservoir.


  • Top Cited Papers
    Open Access

    Exploring the Prospects and Challenges of Fluorine-Free Firefighting Foams (F3) as Alternatives to Aqueous Film-Forming Foams (AFFF): A Review

    by Fatema Tuj Jahura, Nur-Us-Shafa Mazumder, Tanjim Hossain, Arash Kasebi, Arjunsing Girase, R. Bryan Ormond

    This review provides a comparative analysis of the performance, toxicity, environmental impact, and health risks associated with fluorotelomer-based/short-chain AFFF and F3. Despite notable progress in F3 development, achieving comparable performance remains challenging in some cases. F3 formulations, while promising, are yet to be considered a direct replacement for AFFF in all Class B fire suppression scenarios due to variations in their performance across different fuel types and test conditions. Available studies indicate that commercially available F3 exhibit greater biodegradability and reduced environmental persistence compared to AFFF. However, some alternatives may still pose similar environmental impacts. Limited ecotoxicity studies suggest that some F3 may exhibit equal or even higher toxicity to aquatic species than short-chain (C6) AFFF. Toxicological assessments and risk evaluations of F3 should consider factors beyond environmental persistence, including acute and chronic ecotoxicity, potential endocrine disruption, and the full toxicological profile of foam formulations and their individual components. Further research is necessary to understand the fate, transport, bioaccumulation, and toxicity of F3 degradation products. Addressing these knowledge gaps is crucial to ensure the safe and sustainable implementation of F3 as an alternative fire suppression solution.


  • Open Access

    Percutaneous Absorption of Fireground Contaminants: Naphthalene, Phenanthrene, and Benzo[a]pyrene in Porcine Skin in an Artificial Sweat Vehicle

    by Chandler Probert, Emma Nixon, R. Bryan Ormond, Ronald Baynes

    Firefighters face significant risks of exposure to toxic chemicals, such as polycyclic aromatic hydrocarbons (PAHs), during fire suppression activities. PAHs have been found in the air, on the gear and equipment, and in biological samples such as the skin, breath, urine, and blood of firefighters after fire response. However, the extent to which exposure occurs via inhalation, dermal absorption, or ingestion is unclear. In this study, three PAHs, naphthalene, phenanthrene, and benzo[a]pyrene, were applied to porcine skin in vitro in an artificial sweat solution to better gauge firefighters’ dermal exposures while mimicking their sweaty skin conditions using an artificial sweat dosing vehicle. Multiple absorption characteristics were calculated, including cumulative absorption, percent dose absorbed, diffusivity, flux, lag time, and permeability. The absorption of the PAHs was greatly influenced by their molecular weight and solubility in the artificial sweat solution. Naphthalene had the greatest dose absorption efficiency (35.0 ± 4.6% dose), followed by phenanthrene (6.8 ± 3.2% dose), and lastly, benzo[a]pyrene, which had the lowest absorption (0.03 ± 0.04% dose). The lag times followed a similar trend. All chemicals had a lag time of approximately 60 min or longer, suggesting that chemical concentrations on the skin may be reduced by immediate skin cleansing practices after fire exposure.


  • Open Access

    Assessing the Impact of Pre-Soaking to Enhance Laundering Efficacy of Firefighter Turnout Gear

    by Tanjim Hossain, R. Bryan Ormond

    Firefighters are exposed to hazardous chemicals at fire scenes, including polycyclic aromatic hydrocarbons (PAHs) among many others, which pose significant health risks. Current laundering practices are ineffective at removing persistent contaminants from turnout gear, necessitating further research to optimize cleaning methods. This study explores the impact of presoaking prior to the laundering process and the factors that can affect its effectiveness, including the presoaking duration and detergent concentration, in PAH removal when laundering. For this, contaminated fabric swatches were subjected to various presoaking durations (1, 3, and 12 h) and detergent concentrations (99:1 and 90:10 water-to-detergent ratios) before undergoing bench-scale washing. The cleaning efficacy was assessed for 16 PAH compounds, including both low-molecular-weight (LMW) PAHs and high-molecular-weight (HMW) PAHs. Moreover, the removal mechanisms of PAHs from turnout gear were fundamentally explained using partition coefficients and standard affinities with different parameters during washing. The results demonstrate that 3 h and 12 h of presoaking lead to 2.8 and 4.3 times greater HMW PAH removal, respectively. After 12 h of presoaking in a 90:10 water-to-detergent ratio, 97% of the LMW PAHs and 78% of the HMW PAHs were removed, compared to only an 11% removal of the HMW PAHs with a 99:1 ratio. Additionally, direct washing with a 90:10 ratio achieved comparable efficacy to that of presoaking with the same water-to-detergent ratio, indicating the crucial role of detergent concentration during laundering. These findings offer valuable insights for optimizing firefighter safety practices, emphasizing the role of presoaking and the appropriate methods to perform presoaking to mitigate firefighters’ occupational exposure risks to toxic substances and ensure gear reliability.