AGArjunsing Girase

Arjunsing Girase

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arjunsing Girase has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of an animatronic headform test method for determining the efficacy of medical masks and barrier face coverings—part 2: validation study

    by Melissa Armistead, Didem Kiryaman, Anuja Dandekar, Mark Gaskill, Marc Mathews, Arjunsing Girase, R. Bryan Ormond

    There is a need for a realistic method to evaluate the performance of barrier face coverings and medical masks in the wake of growing respiratory concerns among the general public. In this study, the previous animatronic headform test method was optimized to evaluate the total filtration efficacy and breathing resistance of 12 products during a 10-minute simulated fit test. These products included three respiratory devices, three medical masks, and six barrier face covering styles. The revised method was able to differentiate between products with total filtration efficacies ranging from 14% to 93%, down to a difference in means of 2% at 0.3 μm optical diameter. The impact of fit was illustrated by the increase in total filtration efficacy and breathing resistance across all three medical masks when the ear loops were tightened. The coefficient of variation for each product fell below 20% at 0.3 μm optical diameter, indicating good measurement stability. A second operator conducted an intra-lab validation to determine the method's reliability. This analysis confirmed the improved repeatability and reproducibility of the headform test method, which was shown to effectively evaluate the total filtration efficacy of respiratory products as a system in a controlled laboratory setting. However, more research is needed to improve the sensitivity of the breathing resistance measurements. Comparison to the ASTM F3502-21 Standard Specification for Barrier Face Coverings highlighted the differences between evaluating these products as a sealed system or as they are intended to be worn, with an overall decrease in total filtration efficiency and breathing resistance due to leakage when evaluated on the headform.

  • Open Access

    Development of an animatronic headform test method for determining the efficacy of medical masks and barrier face coverings—part 1: total filtration efficacy

    by Melissa Armistead, Anuja Dandekar, Marc Mathews, Madilynn Smith, Mark Gaskill, Arjunsing Girase, R. Bryan Ormond

    The effectiveness of face coverings against respiratory viruses is crucial for public health but often lacks realistic performance assessments of protection and comfort. In this study, a system-level test method was developed using an animatronic headform to incorporate fit and dynamic wear into the assessment of total filtration efficacy of medical masks and barrier face coverings. Six commercially available products were evaluated, including an N95 respirator as the control. Total filtration efficacy was calculated from differential particle counts recorded inside and outside of face coverings each minute. The baseline method was able to statistically differentiate between products to a difference in means of 5% at a particle size of 0.3 μm optical diameter. The 16 and 28 L/min sinusoidal flow rates significantly impacted total filtration efficacy, as did the influence of headform movement and duration of wear for select products. There were statistical differences between operators at both flow rates for the KN95 and surgical style masks that were difficult to don consistently, highlighting the variability in performance due to fit. However, the product type remained the most significant cause of variance in the method at 66.10%, demonstrating that the headform test method was able to repeatedly and reproducibly evaluate the efficacy of various face coverings. Furthermore, there were significant decreases in filtration when the facepiece was not sealed properly due to poor fit. This highlights the importance of evaluating these source control devices, including barrier face coverings and public use of medical masks, as they are intended to be worn to incorporate their fit into the reported results.


  • Top Cited Papers
    Open Access

    Exploring the Prospects and Challenges of Fluorine-Free Firefighting Foams (F3) as Alternatives to Aqueous Film-Forming Foams (AFFF): A Review

    by Fatema Tuj Jahura, Nur-Us-Shafa Mazumder, Tanjim Hossain, Arash Kasebi, Arjunsing Girase, R. Bryan Ormond

    This review provides a comparative analysis of the performance, toxicity, environmental impact, and health risks associated with fluorotelomer-based/short-chain AFFF and F3. Despite notable progress in F3 development, achieving comparable performance remains challenging in some cases. F3 formulations, while promising, are yet to be considered a direct replacement for AFFF in all Class B fire suppression scenarios due to variations in their performance across different fuel types and test conditions. Available studies indicate that commercially available F3 exhibit greater biodegradability and reduced environmental persistence compared to AFFF. However, some alternatives may still pose similar environmental impacts. Limited ecotoxicity studies suggest that some F3 may exhibit equal or even higher toxicity to aquatic species than short-chain (C6) AFFF. Toxicological assessments and risk evaluations of F3 should consider factors beyond environmental persistence, including acute and chronic ecotoxicity, potential endocrine disruption, and the full toxicological profile of foam formulations and their individual components. Further research is necessary to understand the fate, transport, bioaccumulation, and toxicity of F3 degradation products. Addressing these knowledge gaps is crucial to ensure the safe and sustainable implementation of F3 as an alternative fire suppression solution.


  • Open Access

    Toward the future of firefighter gear: Assessing fluorinated and non-fluorinated outer shells following simulated on-the-job exposures

    by Nur-Us-Shafa Mazumder, Jingtian Lu, Andrew Stephen Hall, Arash Kasebi, Arjunsing Girase, Farzaneh Masoud, Jeffrey O. Stull, R. Bryan Ormond

    In 2022, the occupation of firefighting was categorized as a “Group 1” carcinogen, meaning it is known to be carcinogenic to humans. The personal protective equipment that structural firefighters wear is designed to safeguard them from thermal, physical, and chemical hazards while maintaining thermo-physiological comfort. Typically, the outer layer of structural turnout gear is finished with a durable water and oil-repellent (DWR) based on per- and polyfluoroalkyl substances (PFAS) that helps limit exposure to water and hazardous liquids. The PFAS-based aqueous emulsion typically used in DWR finishes is highly persistent and can cause various health problems if absorbed into the body through ingestion, inhalation, and/or dermal absorption. In response, the U.S. Fire Service has begun using non-PFAS water repellants in firefighter turnout gear. This study aims to evaluate the performance of both traditional PFAS-based and alternative non-PFAS outer shell materials. The study involved exposing both PFAS-based and non-PFAS DWR outer shell materials in turnout composites to simulated job exposures (i.e., weathering, thermal exposure, and laundering) that artificially aged the materials. After exposures, samples were evaluated for repellency, durability, thermal protection, and surface chemistry analysis to determine any potential performance trade-offs that may exist. Non-PFAS outer shell fabrics were found not to be diesel/oil-repellent, posing a potential flammability hazard if exposed to diesel and subsequent flame on an emergency response. Both PFAS-based and non-PFAS sets of fabrics performed similarly in terms of thermal protective performance, tearing strength, and water repellency. The surface analysis suggests that both PFAS and non-PFAS chemistries can degrade and shed from fabrics during the aging process. The study indicates that firefighters should be educated and trained regarding the potential performance trade-offs, such as oil absorption and flammability concerns when transitioning to non-PFAS outer shell materials.


  • Open Access

    Degradation of Poly(ε-caprolactone) Resorbable Multifilament Yarn under Physiological Conditions

    by Monica V. Deshpande, Arjunsing Girase, Martin W. King

    Poly(ε-caprolactone) (PCL) is a hydrophobic, resorbable aliphatic polymer recognized for its low tenacity and extensive elongation at break, making it a popular choice for fabricating biodegradable tissue engineering scaffolds. PCL’s slow degradation rate typically results in a complete resorption period of 2 to 3 years. While numerous studies have examined the degradation of PCL in various forms such as films and webs, no study to date has investigated its physiological degradation in multifilament yarn form. In this study, we subjected PCL multifilament yarn samples to physiological conditions in phosphate-buffered saline (PBS) maintained at a consistent temperature of 37 ± 2 °C and agitated at 45 rpm for a period of 32 weeks. We retrieved samples at five different intervals to analyze the degradation profile of the multifilament yarn. This allowed us to estimate the complete resorption time and rate under these in vitro conditions. Over the 32-week period, the multifilament yarn’s mass decreased by 4.8%, its elongation at break declined by 42%, the tenacity dropped by 40%, and the peak load at break fell by 46.5%. Based on these findings, we predict that a scaffold structure incorporating PCL multifilament yarn would undergo complete resorption in approximately 14 months under physiological conditions, such as in PBS solution at a pH of approximately 7 and a temperature of 37 °C.


  • Open Access

    Impact of conventional and advanced cleaning techniques on the durability of firefighter turnout ensembles

    by Arjunsing Girase, Donald B. Thompson, R. Bryan Ormond

    The concern for firefighters’ occupational exposure to harmful contaminants is growing due to the increase in health issues in the firefighting community. At such times, effective decontamination of personnel and equipment is an essential component of a hazard mitigation strategy. The current decontamination practices used for firefighter protective clothing have been shown to not be very effective. Hence, the scientific community is looking for several alternatives to conventional washing procedures. Liquid carbon dioxide (CO2) has been used in laundering and has distinct advantages over conventional dry-cleaning solvents such as perchloroethylene. The following study is aimed to assess how different washing procedures affect the durability of the turnout material. The study includes using three washing procedures on different samples: 1) conventional washing procedure, 2) liquid CO2 washing procedure, and 3) a high-temperature washing procedure. Samples for durability testing were constructed from a common aramid fabric used in firefighter turnout ensembles. These swatches were subjected to different washing techniques. The durability assessment was performed for physical testing of the samples, visual inspection, water repellency, and quantifying color changes using spectrophotometric analysis. The conventional wash and high-temperature washing affected the durability of the outer shell material in a significant manner. The liquid CO2 process did not affect the samples’ water repellency or physical strength. In contrast, conventional and high-temperature washing significantly affected the durability of the outer shell material. However, all samples met the criteria for tearing strength outlined in the NFPA 1971 standard subsection 7.1.11.


  • Open Access

    Qualitative Assessment of Off-Gassing of Compounds from Field-Contaminated Firefighter Jackets with Varied Air Exposure Time Intervals Using Headspace GC-MS

    by Arjunsing Girase, Adhiraj Shinde, Robert Bryan Ormond

    Firefighters are exposed to a complex mix of volatile and semi-volatile compounds from burning construction materials, consumer products, and other elements during fire suppression and rescue. These compounds can be absorbed onto the gear worn by firefighters and, depending on their volatility, can be released from the gear under different conditions. Few studies have focused on the off-gassing of toxic compounds from firefighters’ gear, particularly in terms of qualitative analysis methods. This study introduces a novel qualitative analysis method using headspace gas chromatography–mass spectrometry (HS-GC-MS) to assess off-gassing from field-contaminated jackets at regular intervals. Our findings show that certain compounds, such as acetic acid and di-ethyl-hexyl-phthalate (DEHP), remained present even after the gear were allowed to air out for 48 h. The persistent off-gassing of chemicals, even under ambient conditions, raises concerns about potential hazards that could pose risks for personnel in the vicinity of contaminated gear, including inside fire stations. The implications of these findings extend beyond fire stations and may have significant public health implications for firefighters who are repeatedly exposed to these compounds over time.


  • Open Access

    Bench-Scale and Full-Scale Level Evaluation of the Effect of Parameters on Cleaning Efficacy of the Firefighters’ PPE

    by Arjunsing Girase, Donald Thompson, Robert Bryan Ormond

    The National Fire Protection Association (NFPA) 1851 document provides guidelines for firefighters on the care and maintenance of their PPE, including decontamination practices. Firefighters are exposed to various toxic chemicals during fire suppression activities, making effective decontamination crucial for their safety. This study evaluated the efficacy of different washing parameters, including temperature, time, and surfactants, on cleaning outer-shell material contaminated with nine targeted compounds from three different functional groups: phenols, polycyclic aromatic hydrocarbons (PAHs), and phthalates. The study was conducted on both bench-scale and full-scale levels, with contaminated swatches washed in a water shaker bath in the bench-scale evaluation and full-sized washer extractors used in the full-scale evaluation. The results showed that bench-scale washing demonstrated similar trends in contaminant removal to full-scale washing. Importantly, the study highlighted the complexity of removing fireground contaminants from the personal protective ensemble (PPE). The findings of this study have practical implications for the firefighting industry as they provide insight into the effectiveness of different washing parameters for PPE decontamination. Future studies could explore the impact of repeated washing on PPE and investigate the potential for developing more efficient decontamination strategies. Ultimately, the study underscores the importance of ongoing efforts to ensure the safety of firefighters, who face significant occupational hazards.


  • Open Access

    Comparative Analysis of the Liquid CO2 Washing with Conventional Wash on Firefighters’ Personal Protective Equipment (PPE)

    by Arjunsing Girase, Donald Thompson, Robert Bryan Ormond

    Firefighters are exposed to several potentially carcinogenic fireground contaminants. The current NFPA 1851 washing procedures are less effective in cleaning due to the limited intensity of the washing conditions that are used. The 2020 edition of NFPA 1851 has added limited specialized cleaning for higher efficacy. The liquid carbon dioxide (CO2) laundering technique has gained popularity in recent years due to its availability to remove contaminants and its eco-friendliness. The primary aim of this study is to address the firefighter questions regarding the efficacy of cleaning with liquid CO2 and to compare it with the conventional washing technique. The unused turnout jackets were contaminated with a mixture of fireground contaminants. These turnout jackets were cleaned with conventional NFPA 1851-appoved aqueous washing and a commercially available liquid CO2 method. Post-cleaning samples were analyzed for contamination using pressurized solvent extraction and GC-MS. The liquid CO2 technique demonstrated considerable improvement in washing efficiency compared to the conventional washing.