Wern Kam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wern Kam has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Michael Martyn
National Univ. of Ireland, Galway (Ireland)
2 shared publications - Peter Woulfe
Optical Fibre Sensors Research Centre, University of Limerick, Limerick, Ireland
2 shared publications - Sinead O Keeffe
Optical Fibre Sensors Research Centre, University of Limerick, Limerick, Ireland
2 shared publications Sinead O’kEeffe
Optical Fibre Sensors Research Centre (OFSRC) , Dept. of Electronic and Computer Engineering, University of Limerick, Ireland
2 shared publications- Agnese Giaz
INFN, Sezione di Milano, I-20133 Milano, Italy
1 shared publication - Camille Belanger-Champagne
TRIUMF, Vancouver, British Columbia, Canada
1 shared publication
Latest Publications
- Open Access
- 22 November 2022
- Published by Sissa Medialab Srl
- Vol. 414, 846
A 16-sensor prototype for brachytherapy in vivo dosimetry characterization
The ORIGIN project (Optical Fiber Dose Imaging for Adaptive Brachytherapy) targets the production and qualification of a real-time radiation dose imaging and source localization system for both Low Dose Rate and High Dose Rate brachytherapy treatments. This goal will be achieved through a 16-fibre sensor system. Each fibre tip has been engineered to house a small volume of scintillating material to allow for measurements of the delivered dose. The instrument is based on Silicon Photomultipliers detectors, with a solution fully qualified on a single fibre prototype and currently being scaled up through the use of the CITIROC1A ASIC by WEEROC, embedded in the FERS-DT5202 scalable platform designed by CAEN S.p.A. The key features for a system such as ORIGIN, which aims to perform dose measurements in a clinical environment, are fibre response uniformity, system stability, high sensitivity, and perfect reproducibility. The commissioning of the 16-channel dosimeter system in laboratory conditions, with an X-ray cabinet, demonstrated reproducibility of measurements with deviations below 1% after the equalization procedure of the 16 sensors. Finally, the system performance, evaluated in clinical conditions (High Dose Rate centre, Belfast Hospital), allowed for valuable insight into the possible systematics which are present in the current system while simultaneously corroborating the validity of the equalization procedure.
- 22 November 2022
- Published by Sissa Medialab Srl
- Vol. 414, 846
Open AccessA 16-sensor prototype for brachytherapy in vivo dosimetry characterization
The ORIGIN project (Optical Fiber Dose Imaging for Adaptive Brachytherapy) targets the production and qualification of a real-time radiation dose imaging and source localization system for both Low Dose Rate and High Dose Rate brachytherapy treatments. This goal will be achieved through a 16-fibre sensor system. Each fibre tip has been engineered to house a small volume of scintillating material to allow for measurements of the delivered dose. The instrument is based on Silicon Photomultipliers detectors, with a solution fully qualified on a single fibre prototype and currently being scaled up through the use of the CITIROC1A ASIC by WEEROC, embedded in the FERS-DT5202 scalable platform designed by CAEN S.p.A. The key features for a system such as ORIGIN, which aims to perform dose measurements in a clinical environment, are fibre response uniformity, system stability, high sensitivity, and perfect reproducibility. The commissioning of the 16-channel dosimeter system in laboratory conditions, with an X-ray cabinet, demonstrated reproducibility of measurements with deviations below 1% after the equalization procedure of the 16 sensors. Finally, the system performance, evaluated in clinical conditions (High Dose Rate centre, Belfast Hospital), allowed for valuable insight into the possible systematics which are present in the current system while simultaneously corroborating the validity of the equalization procedure.
- Open Access
Dosimetric Application of Phosphorus Doped Fibre for X-ray and Proton Therapy
Phosphorous-doped silica optical fibres with a core diameter of 4 µm were tested in X-ray and proton fields for application in cancer therapy dosimetry. Specifically, the radiation-induced attenuation was investigated in terms of linearity in deposited dose in 15 MV and 6 MV photons and 74 MeV protons, as well as Bragg-peak detection along the proton track. Fibres were found to demonstrate linear relative dose response in both radiation modalities, but possible saturation did occur at the high linear energy transfer of the Bragg peak. This demonstrates the possibility to use these fibres as a relative dosimeter for radiation therapy applications.
Open AccessDosimetric Application of Phosphorus Doped Fibre for X-ray and Proton Therapy
Phosphorous-doped silica optical fibres with a core diameter of 4 µm were tested in X-ray and proton fields for application in cancer therapy dosimetry. Specifically, the radiation-induced attenuation was investigated in terms of linearity in deposited dose in 15 MV and 6 MV photons and 74 MeV protons, as well as Bragg-peak detection along the proton track. Fibres were found to demonstrate linear relative dose response in both radiation modalities, but possible saturation did occur at the high linear energy transfer of the Bragg peak. This demonstrates the possibility to use these fibres as a relative dosimeter for radiation therapy applications.
- 1 January 2021
- Published by Optica Publishing Group
- p. Th4.1
Evaluation of Optical Fibre Based Sensor for use in Brachytherapy Treatment.
This paper presents an evaluation of optical fibre sensors for use in brachytherapy treatment where the sensor tip is embedded with radiosensitive scintillation powder, Terbium doped Gadolinium Oxysulphide (Gd2O2S:Tb). Two sensors, fabricated using the same fiber design parameter and size, have been fabricated and evaluated using a Standard Imaging HDR 1000 Well Chamber for increasing numbers of brachytherapy seeds. A sensor holder was designed and 3-D printed to accommodate both the seeds and the sensor for this evaluation purposes. The results show a linear response with number of seeds and demonstrate an excellent agreement with the seed activity measured using a commercial type well chamber. In future, this can be a potential calibration methods for optical fibre sensors prior to use in brachytherapy.
- 1 January 2021
- Published by Optica Publishing Group
- p. Th4.1
Evaluation of Optical Fibre Based Sensor for use in Brachytherapy Treatment.
This paper presents an evaluation of optical fibre sensors for use in brachytherapy treatment where the sensor tip is embedded with radiosensitive scintillation powder, Terbium doped Gadolinium Oxysulphide (Gd2O2S:Tb). Two sensors, fabricated using the same fiber design parameter and size, have been fabricated and evaluated using a Standard Imaging HDR 1000 Well Chamber for increasing numbers of brachytherapy seeds. A sensor holder was designed and 3-D printed to accommodate both the seeds and the sensor for this evaluation purposes. The results show a linear response with number of seeds and demonstrate an excellent agreement with the seed activity measured using a commercial type well chamber. In future, this can be a potential calibration methods for optical fibre sensors prior to use in brachytherapy.
- 1 January 2018
- Published by Optica Publishing Group
- p. TuE10
Evaluation of an All Plastic 3-D Printed POF Sensor for Monitoring Spine Bending in Biomedical Applications
This work describes the evaluation of a 3-D printed all plastic POF sensor for real-time monitoring of spine bending for biomedical applications. The correlation and evaluation of POF sensor against a conventional spine monitoring Biometrics goniometer on sagittal and lateral spine bending assessment is presented. 18 healthy subjects were recruited for the field test to simultaneously compare the performance of the POF sensor against goniometer at different spine posture. The POF sensor shows a good performance and linearly correlated with the Biometrics sensor with a correlation coefficient, R2 of 0.8696 for bending in sagittal plane and 0.8599 in lateral plane. This study evaluated the validity of POF sensor for analyzing bending of lumbar spine in both sagittal and lateral directions.
- 1 January 2018
- Published by Optica Publishing Group
- p. TuE10
Evaluation of an All Plastic 3-D Printed POF Sensor for Monitoring Spine Bending in Biomedical Applications
This work describes the evaluation of a 3-D printed all plastic POF sensor for real-time monitoring of spine bending for biomedical applications. The correlation and evaluation of POF sensor against a conventional spine monitoring Biometrics goniometer on sagittal and lateral spine bending assessment is presented. 18 healthy subjects were recruited for the field test to simultaneously compare the performance of the POF sensor against goniometer at different spine posture. The POF sensor shows a good performance and linearly correlated with the Biometrics sensor with a correlation coefficient, R2 of 0.8696 for bending in sagittal plane and 0.8599 in lateral plane. This study evaluated the validity of POF sensor for analyzing bending of lumbar spine in both sagittal and lateral directions.