Huixin Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huixin Liang has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Lida Shen
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
6 shared publications - Chang Jiang Wang
Department of Engineering and Design, University of Sussex, Sussex House, Brighton, UK
5 shared publications - Deqiao Xie
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
5 shared publications Jie Cui
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
4 shared publications- Zongjun Tian
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
4 shared publications - Jianfeng Zhao
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
3 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9, 1307
Trabecular-Like Scaffold Dictates Osteogenesis via Fluid Shear Stress-Induced Metabolic Reprogramming through the CAV1–HIF-1α Axis
The structural design of bone scaffolds determines the local fluid mechanical microenvironment; however, how such cues program stem cell metabolism to drive osteogenesis remains unclear. In this study, Voronoi-based trabecular-like scaffolds with tunable porosity were engineered to modulate fluid shear stress (FSS) while preserving a consistent topology. Computational fluid dynamics analyses confirmed that architectures with lower porosity generated higher FSS, enabling controlled investigation of mechano-metabolic coupling. Under dynamic culture conditions, bone marrow mesenchymal stem cells (BMSCs) cultured on high-FSS scaffolds exhibited enhanced osteogenic differentiation in vitro and promoted bone regeneration in vivo. Integrated transcriptomic, proteomic, and metabolomic analyses identified caveolin-1 (CAV1) as a prominent FSS-responsive membrane regulator. Mechanistically, CAV1 enhanced phosphatidylinositol 3-kinase (PI3K)–AKT signaling, stabilized hypoxia-inducible factor-1α (HIF-1α), and induced a glycolytic shift that supports the energetic and biosynthetic demands of osteogenesis. Pharmacological inhibition of PI3K, HIF-1α, or glycolysis abolished FSS-driven osteogenic responses, validating a CAV1-centered mechano-metabolic axis. These findings establish a direct link between scaffold microarchitecture and metabolic regulation of osteogenesis and provide design principles for mechanically instructive bone repair materials.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9, 1307
Open AccessTrabecular-Like Scaffold Dictates Osteogenesis via Fluid Shear Stress-Induced Metabolic Reprogramming through the CAV1–HIF-1α Axis
The structural design of bone scaffolds determines the local fluid mechanical microenvironment; however, how such cues program stem cell metabolism to drive osteogenesis remains unclear. In this study, Voronoi-based trabecular-like scaffolds with tunable porosity were engineered to modulate fluid shear stress (FSS) while preserving a consistent topology. Computational fluid dynamics analyses confirmed that architectures with lower porosity generated higher FSS, enabling controlled investigation of mechano-metabolic coupling. Under dynamic culture conditions, bone marrow mesenchymal stem cells (BMSCs) cultured on high-FSS scaffolds exhibited enhanced osteogenic differentiation in vitro and promoted bone regeneration in vivo. Integrated transcriptomic, proteomic, and metabolomic analyses identified caveolin-1 (CAV1) as a prominent FSS-responsive membrane regulator. Mechanistically, CAV1 enhanced phosphatidylinositol 3-kinase (PI3K)–AKT signaling, stabilized hypoxia-inducible factor-1α (HIF-1α), and induced a glycolytic shift that supports the energetic and biosynthetic demands of osteogenesis. Pharmacological inhibition of PI3K, HIF-1α, or glycolysis abolished FSS-driven osteogenic responses, validating a CAV1-centered mechano-metabolic axis. These findings establish a direct link between scaffold microarchitecture and metabolic regulation of osteogenesis and provide design principles for mechanically instructive bone repair materials.
- Open Access
- 23 December 2025
- Published by Elsevier in Materials & Design
- Vol. 261
3D printed Zn-Cu alloy bone scaffolds via nanoparticle incorporation: Microstructural evolution and enhanced mechanical-antimicrobial-osteogenic properties
- 23 December 2025
- Published by Elsevier in Materials & Design
- Vol. 261
Open Access3D printed Zn-Cu alloy bone scaffolds via nanoparticle incorporation: Microstructural evolution and enhanced mechanical-antimicrobial-osteogenic properties
- Open Access
- 6 March 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 29, 5330-5339
Comparison of osteogenic capability between porous Zn and porous Ti6Al4V scaffolds: An in vivo study
- 6 March 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 29, 5330-5339
Open AccessComparison of osteogenic capability between porous Zn and porous Ti6Al4V scaffolds: An in vivo study
- Open Access
- 6 March 2024
- Published by Elsevier in Engineering
- Vol. 37, 138-151
A Polyvinyl Alcohol/Acrylamide Hydrogel with Enhanced Mechanical Properties Promotes Full-Thickness Skin Defect Healing by Regulating Immunomodulation and Angiogenesis Through Paracrine Secretion
- 6 March 2024
- Published by Elsevier in Engineering
- Vol. 37, 138-151
Open AccessA Polyvinyl Alcohol/Acrylamide Hydrogel with Enhanced Mechanical Properties Promotes Full-Thickness Skin Defect Healing by Regulating Immunomodulation and Angiogenesis Through Paracrine Secretion
- Open Access
- 1 January 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 28, 3707-3721
Microstructure development of AM-fabricated pure Zn with heat-treatment and its mechanical properties, degradation behavior, and biocompatibility
- 1 January 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 28, 3707-3721
Open AccessMicrostructure development of AM-fabricated pure Zn with heat-treatment and its mechanical properties, degradation behavior, and biocompatibility
- Open Access
- 27 June 2023
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 9 (6) , 0222-56
Sub-regional design of the bionic bone scaffolds using macrostructural topology
With the increasing demand for bone repair, the bionic bone scaffolds have become a research hotspot. A sub-regional design method of the bionic bone scaffolds, using macrostructural topology, is proposed in this paper, aiming to provide a functionally enhanced region division method for the gradient design. The macrostructural topology was carried out by the bi-directional evolutionary structural optimization (BESO), dividing the predefined design domain into sub-region A and sub-region B. Subsequently, a combined probability sphere model and a distance-to-scale coefficient mapping model are established to implement the graded porosification based on the Voronoi tessellation. This approach takes geometric and mechanical continuity into fully account and assures a reasonable distribution of characteristic parameters, yielding to improve the mechanical strength under specific stress conditions. Finally, the scaffolds were fabricated by the laser powder bed fusion (LPBF) process using the Ti-6Al-4V powder. The results of compression tests are satisfactory, showing that the as-built specimens implement sub-regional functionality. The apparent elastic modulus and the ultimate strength range, respectively, between 1.50 GPa and 7.12 GPa (for the first module) and between 38.55 MPa and 268.03 MPa (for the second module), which conform to the required level of natural bone, providing a possibility for clinical application.
- 27 June 2023
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 9 (6) , 0222-56
Open AccessSub-regional design of the bionic bone scaffolds using macrostructural topology
With the increasing demand for bone repair, the bionic bone scaffolds have become a research hotspot. A sub-regional design method of the bionic bone scaffolds, using macrostructural topology, is proposed in this paper, aiming to provide a functionally enhanced region division method for the gradient design. The macrostructural topology was carried out by the bi-directional evolutionary structural optimization (BESO), dividing the predefined design domain into sub-region A and sub-region B. Subsequently, a combined probability sphere model and a distance-to-scale coefficient mapping model are established to implement the graded porosification based on the Voronoi tessellation. This approach takes geometric and mechanical continuity into fully account and assures a reasonable distribution of characteristic parameters, yielding to improve the mechanical strength under specific stress conditions. Finally, the scaffolds were fabricated by the laser powder bed fusion (LPBF) process using the Ti-6Al-4V powder. The results of compression tests are satisfactory, showing that the as-built specimens implement sub-regional functionality. The apparent elastic modulus and the ultimate strength range, respectively, between 1.50 GPa and 7.12 GPa (for the first module) and between 38.55 MPa and 268.03 MPa (for the second module), which conform to the required level of natural bone, providing a possibility for clinical application.
- Open Access
- 21 December 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9, 779854
Analysis of Mechanical Properties and Permeability of Trabecular-Like Porous Scaffold by Additive Manufacturing
Human bone cells live in a complex environment, and the biomimetic design of porous structures attached to implants is in high demand. Porous structures based on Voronoi tessellation with biomimetic potential are gradually used in bone repair scaffolds. In this study, the mechanical properties and permeability of trabecular-like porous scaffolds with different porosity levels and average apertures were analyzed. The mechanical properties of bone-implant scaffolds were evaluated using finite element analysis and a mechanical compression experiment, and the permeability was studied by computational fluid dynamics. Finally, the attachment of cells was observed by confocal fluorescence microscope. The results show that the performance of porous structures can be controlled by the initial design of the microstructure and tissue morphology. A good structural design can accurately match the performance of the natural bone. The study of mechanical properties and permeability of the porous structure can help address several problems, including stress shielding and bone ingrowth in existing biomimetic bone structures, and will also promotes cell adhesion, migration, and eventual new bone attachment.
- 21 December 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9, 779854
Open AccessAnalysis of Mechanical Properties and Permeability of Trabecular-Like Porous Scaffold by Additive Manufacturing
Human bone cells live in a complex environment, and the biomimetic design of porous structures attached to implants is in high demand. Porous structures based on Voronoi tessellation with biomimetic potential are gradually used in bone repair scaffolds. In this study, the mechanical properties and permeability of trabecular-like porous scaffolds with different porosity levels and average apertures were analyzed. The mechanical properties of bone-implant scaffolds were evaluated using finite element analysis and a mechanical compression experiment, and the permeability was studied by computational fluid dynamics. Finally, the attachment of cells was observed by confocal fluorescence microscope. The results show that the performance of porous structures can be controlled by the initial design of the microstructure and tissue morphology. A good structural design can accurately match the performance of the natural bone. The study of mechanical properties and permeability of the porous structure can help address several problems, including stress shielding and bone ingrowth in existing biomimetic bone structures, and will also promotes cell adhesion, migration, and eventual new bone attachment.
- Open Access
Mechanical Properties of In-Situ Synthesis of Ti-Ti3Al Metal Composite Prepared by Selective Laser Melting
Titanium composite strengthened by Ti3Al precipitations is considered to be one of the excellent materials that is widely used in engineering. In this work, we prepared a kind of Ti-Ti3Al metallic composite by in-situ synthesis technology during the SLM (selective laser melting) process, and analyzed its microstructure, wear resistance, microhardness, and compression properties. The results showed that the Ti-Ti3Al composite, prepared by in-situ synthesis technology based on SLM, had more homogeneous Ti3Al-enhanced phase dispersion strengthening structure. The grain size of the workpiece was about 1 μm, and that of the Ti3Al particle was about 200 nm. Granular Ti3Al was precipitated after the aluminum-containing workpiece formed, with a relatively uniform distribution. Regarding the mechanical properties, the hardness (539 HV) and the wear resistance were significantly improved when compared with the Cp-Ti workpiece. The compressive strength of the workpiece increased from 886.32 MPa to 1568 MPa, and the tensile strength of the workpiece increased from 531 MPa to 567 MPa after adding aluminum. In the future, the combination of in-situ synthesis technology and SLM technology can be used to flexibly adjust the properties of Ti-based materials.
Open AccessMechanical Properties of In-Situ Synthesis of Ti-Ti3Al Metal Composite Prepared by Selective Laser Melting
Titanium composite strengthened by Ti3Al precipitations is considered to be one of the excellent materials that is widely used in engineering. In this work, we prepared a kind of Ti-Ti3Al metallic composite by in-situ synthesis technology during the SLM (selective laser melting) process, and analyzed its microstructure, wear resistance, microhardness, and compression properties. The results showed that the Ti-Ti3Al composite, prepared by in-situ synthesis technology based on SLM, had more homogeneous Ti3Al-enhanced phase dispersion strengthening structure. The grain size of the workpiece was about 1 μm, and that of the Ti3Al particle was about 200 nm. Granular Ti3Al was precipitated after the aluminum-containing workpiece formed, with a relatively uniform distribution. Regarding the mechanical properties, the hardness (539 HV) and the wear resistance were significantly improved when compared with the Cp-Ti workpiece. The compressive strength of the workpiece increased from 886.32 MPa to 1568 MPa, and the tensile strength of the workpiece increased from 531 MPa to 567 MPa after adding aluminum. In the future, the combination of in-situ synthesis technology and SLM technology can be used to flexibly adjust the properties of Ti-based materials.
- Open Access
- 25 July 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-12
The biomechanical changes of load distribution with longitudinal tears of meniscal horns on knee joint: a finite element analysis
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.
- 25 July 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-12
Open AccessThe biomechanical changes of load distribution with longitudinal tears of meniscal horns on knee joint: a finite element analysis
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.
- Open Access
The Size Effect on Forming Quality of Ti–6Al–4V Solid Struts Fabricated via Laser Powder Bed Fusion
Laser powder bed fusion (LPBF) is useful for manufacturing complex structures; however, factors affecting the forming quality have not been clearly researched. This study aimed to clarify the influence of geometric characteristic size on the forming quality of solid struts. Ti–6Al–4V struts with a square section on the side length (0.4 to 1.4 mm) were fabricated with different scan speeds. Micro-computed tomography was used to detect the struts’ profile error and defect distribution. Scanning electron microscopy and light microscopy were used to characterize the samples’ microstructure. Nanoindentation tests were conducted to evaluate the mechanical properties. The experimental results illustrated that geometric characteristic size influenced the struts’ physical characteristics by affecting the cooling condition. This size effect became obvious when the geometric characteristic size and the scan speed were both relatively small. The solid struts with smaller geometric characteristic size had more obvious size error. When the geometric characteristic size was smaller than 1 mm, the nanohardness and elastic modulus increased with the increase in scan speed, and decreased with the decline of the geometric characteristic size. Therefore, a relatively high scan speed should be selected for LPBF—the manufacturing of a porous structure, whose struts have small geometric characteristic size.
Open AccessThe Size Effect on Forming Quality of Ti–6Al–4V Solid Struts Fabricated via Laser Powder Bed Fusion
Laser powder bed fusion (LPBF) is useful for manufacturing complex structures; however, factors affecting the forming quality have not been clearly researched. This study aimed to clarify the influence of geometric characteristic size on the forming quality of solid struts. Ti–6Al–4V struts with a square section on the side length (0.4 to 1.4 mm) were fabricated with different scan speeds. Micro-computed tomography was used to detect the struts’ profile error and defect distribution. Scanning electron microscopy and light microscopy were used to characterize the samples’ microstructure. Nanoindentation tests were conducted to evaluate the mechanical properties. The experimental results illustrated that geometric characteristic size influenced the struts’ physical characteristics by affecting the cooling condition. This size effect became obvious when the geometric characteristic size and the scan speed were both relatively small. The solid struts with smaller geometric characteristic size had more obvious size error. When the geometric characteristic size was smaller than 1 mm, the nanohardness and elastic modulus increased with the increase in scan speed, and decreased with the decline of the geometric characteristic size. Therefore, a relatively high scan speed should be selected for LPBF—the manufacturing of a porous structure, whose struts have small geometric characteristic size.