Jin-Wook Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jin-Wook Kang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Chung-Yuen Won
Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
10 shared publications - Hoon Lee
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
4 shared publications - Seung-Wook Hyun
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
4 shared publications - Jintae Kim
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
3 shared publications - Bong-Yeon Choi
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
2 shared publications Hee-Jun Lee
2 shared publications
Latest Publications
- Open Access
Energy Management System of DC Microgrid in Grid-Connected and Stand-Alone Modes: Control, Operation and Experimental Validation
This paper proposes an energy management system (EMS) of direct current (DC) microgrid. In order to implement the proposed EMS, the control and operation method of EMS is presented in this work. While most of the studies have individually examined the grid-connected mode used in building and the stand-alone operation mode applicable to the island, the proposed EMS allows it to be used in both grid-connected mode and stand-alone mode with 10 modes. In order to determine each mode in EMS, not only the amount of generated power, load power, and the state of charge (SOC) of the battery, but also the rated power of the energy storage system (ESS) converter that performs charging and discharging operations is additionally considered. Thus, various uncertainties that may occur in the actual DC microgrid environment can be improved. A laboratory-scale DC microgrid is fabricated to conduct experimental validation of proposed EMS. Experiments of DC microgrid with proposed EMS were performed for each mode, and the experiment waveforms of each power conversion device are included in detail.
Open AccessEnergy Management System of DC Microgrid in Grid-Connected and Stand-Alone Modes: Control, Operation and Experimental Validation
This paper proposes an energy management system (EMS) of direct current (DC) microgrid. In order to implement the proposed EMS, the control and operation method of EMS is presented in this work. While most of the studies have individually examined the grid-connected mode used in building and the stand-alone operation mode applicable to the island, the proposed EMS allows it to be used in both grid-connected mode and stand-alone mode with 10 modes. In order to determine each mode in EMS, not only the amount of generated power, load power, and the state of charge (SOC) of the battery, but also the rated power of the energy storage system (ESS) converter that performs charging and discharging operations is additionally considered. Thus, various uncertainties that may occur in the actual DC microgrid environment can be improved. A laboratory-scale DC microgrid is fabricated to conduct experimental validation of proposed EMS. Experiments of DC microgrid with proposed EMS were performed for each mode, and the experiment waveforms of each power conversion device are included in detail.
- Open Access
- 19 December 2020
- Published by MDPI AG in Electronics
- Vol. 9 (12) , 2195
A Novel Zero Dead-Time PWM Method to Improve the Current Distortion of a Three-Level NPC Inverter
This paper proposes a novel pulse width modulation (PWM) for a three-level neutral point clamped (NPC) voltage source inverter (VSI). When the conventional PWM method is used in three-level NPC VSI, dead time is required to prevent a short circuit caused by the operation of complementary devices on the upper and lower arms. However, current distortion is increased because of the dead time and it can also cause a voltage unbalance in the dc-link. To solve this problem, we propose a zero dead-time width modulation (ZDPWM) which does not require dead time used in complementary operation. The proposed technique applies the offset voltage to the space vector pulse width modulation (SVPWM) reference voltage for the same modulation index (MI) as the conventional SVPWM, but any complementary switching operation needs dead time. In addition, the proposed method is divided into four operation sections using the reference voltage and phase current to operate switching devices which flow the current depending on the section. This ZDPWM method is simply implemented by carrier and reference voltage that reduce the current distortion, because complementary operation that needs dead time is not implemented. However, the operation section is delayed due to the sampling delay that occurs during the experiment. Therefore, in this paper, we conduct a modeling of sampling delay to improve the delay of operation section. To verify the principle and feasibility of the proposed ZDPWM method, a simulation and experiment are implemented.
- 19 December 2020
- Published by MDPI AG in Electronics
- Vol. 9 (12) , 2195
Open AccessA Novel Zero Dead-Time PWM Method to Improve the Current Distortion of a Three-Level NPC Inverter
This paper proposes a novel pulse width modulation (PWM) for a three-level neutral point clamped (NPC) voltage source inverter (VSI). When the conventional PWM method is used in three-level NPC VSI, dead time is required to prevent a short circuit caused by the operation of complementary devices on the upper and lower arms. However, current distortion is increased because of the dead time and it can also cause a voltage unbalance in the dc-link. To solve this problem, we propose a zero dead-time width modulation (ZDPWM) which does not require dead time used in complementary operation. The proposed technique applies the offset voltage to the space vector pulse width modulation (SVPWM) reference voltage for the same modulation index (MI) as the conventional SVPWM, but any complementary switching operation needs dead time. In addition, the proposed method is divided into four operation sections using the reference voltage and phase current to operate switching devices which flow the current depending on the section. This ZDPWM method is simply implemented by carrier and reference voltage that reduce the current distortion, because complementary operation that needs dead time is not implemented. However, the operation section is delayed due to the sampling delay that occurs during the experiment. Therefore, in this paper, we conduct a modeling of sampling delay to improve the delay of operation section. To verify the principle and feasibility of the proposed ZDPWM method, a simulation and experiment are implemented.
- Open Access
- 6 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 759
A Novel Dual Integrated LLC Resonant Converter Using Various Switching Patterns for a Wide Output Voltage Range Battery Charger
This paper proposes a novel dual integrated LLC resonant converter (DI-LRC) with a wide output voltage range using various switching patterns. The primary side of the proposed DI-LLC converter consists of two resonant tanks and six switches, while the secondary side consists of a six-pulse diode rectifier. Depending on the switching pattern of the primary switch, the DI-LRC converter is performed by single full-bridge operation with a voltage gain of 1, series-connected full-bridge operation with a voltage gain of 0.5, series-connected half bridge operation with a voltage gain of 0.25, and parallel-connected full-bridge operation with a voltage gain of 2. Accordingly, the proposed DI-LRC converter has four voltage gain curves with different variations and achieves a wider output voltage range than the conventional single voltage gain curve in a given operating frequency range. In this paper, the equivalent circuits derived for each switching pattern are proposed to analyze the operating characteristics of the proposed converter according to each switching pattern, and each Q factor and voltage gain are calculated based on the analyzed equivalent circuit. The performance of the proposed converter and switching pattern is verified using the simulation and experimental results of the prototype battery charger, which is designed to be 4-kW class.
- 6 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 759
Open AccessA Novel Dual Integrated LLC Resonant Converter Using Various Switching Patterns for a Wide Output Voltage Range Battery Charger
This paper proposes a novel dual integrated LLC resonant converter (DI-LRC) with a wide output voltage range using various switching patterns. The primary side of the proposed DI-LLC converter consists of two resonant tanks and six switches, while the secondary side consists of a six-pulse diode rectifier. Depending on the switching pattern of the primary switch, the DI-LRC converter is performed by single full-bridge operation with a voltage gain of 1, series-connected full-bridge operation with a voltage gain of 0.5, series-connected half bridge operation with a voltage gain of 0.25, and parallel-connected full-bridge operation with a voltage gain of 2. Accordingly, the proposed DI-LRC converter has four voltage gain curves with different variations and achieves a wider output voltage range than the conventional single voltage gain curve in a given operating frequency range. In this paper, the equivalent circuits derived for each switching pattern are proposed to analyze the operating characteristics of the proposed converter according to each switching pattern, and each Q factor and voltage gain are calculated based on the analyzed equivalent circuit. The performance of the proposed converter and switching pattern is verified using the simulation and experimental results of the prototype battery charger, which is designed to be 4-kW class.
- Open Access
- 17 November 2018
- Published by MDPI AG in Electronics
- Vol. 7 (11) , 331
Improved Voltage Drop Compensation Method for Hybrid Fuel Cell Battery System
In this paper, a voltage drop compensation method for hybrid hydrogen fuel cell battery system, with a hydrogen recirculation powering a forklift, is studied. During recirculating hydrogen fuel to recycle hydrogen that has not reacted enough at the system, impurities can be mixed with the hydrogen fuel. This leads to low hydrogen concentration and a drop in the output voltage of the fuel cell system. In excessive voltage drop, the fuel cell system can be shutdown. This paper proposes a voltage drop compensation method using an electrical control algorithm to prevent system shutdown by reducing voltage drop. Technically, voltage drop is typically caused by three kinds of factors: (1) The amount of pure hydrogen supply; (2) the temperature of fuel cell stacks; and (3) the current density to catalysts of the fuel cell. The proposed compensation method detects voltage drop caused by those factors, and generates compensation signals for a controller of a DC–DC converter connecting to the output of the fuel cell stack; thus, the voltage drop is reduced by decreasing output current. At the time, insufficient output current to a load is supplied from the batteries. In this paper, voltage drop caused by the abovementioned three factors is analyzed, and the operating principle of the proposed compensation method is specified. To verify this operation and the feasibility of the proposed method, experiments are conducted by applying it to a 10 kW hybrid fuel cell battery system for a forklift.
- 17 November 2018
- Published by MDPI AG in Electronics
- Vol. 7 (11) , 331
Open AccessImproved Voltage Drop Compensation Method for Hybrid Fuel Cell Battery System
In this paper, a voltage drop compensation method for hybrid hydrogen fuel cell battery system, with a hydrogen recirculation powering a forklift, is studied. During recirculating hydrogen fuel to recycle hydrogen that has not reacted enough at the system, impurities can be mixed with the hydrogen fuel. This leads to low hydrogen concentration and a drop in the output voltage of the fuel cell system. In excessive voltage drop, the fuel cell system can be shutdown. This paper proposes a voltage drop compensation method using an electrical control algorithm to prevent system shutdown by reducing voltage drop. Technically, voltage drop is typically caused by three kinds of factors: (1) The amount of pure hydrogen supply; (2) the temperature of fuel cell stacks; and (3) the current density to catalysts of the fuel cell. The proposed compensation method detects voltage drop caused by those factors, and generates compensation signals for a controller of a DC–DC converter connecting to the output of the fuel cell stack; thus, the voltage drop is reduced by decreasing output current. At the time, insufficient output current to a load is supplied from the batteries. In this paper, voltage drop caused by the abovementioned three factors is analyzed, and the operating principle of the proposed compensation method is specified. To verify this operation and the feasibility of the proposed method, experiments are conducted by applying it to a 10 kW hybrid fuel cell battery system for a forklift.
- Open Access
- 23 September 2018
- Published by MDPI AG in Electronics
- Vol. 7 (10) , 214
A Control Strategy for Bidirectional Isolated 3-Phase Current-Fed Dual Active Bridge Converter
This paper examines the characteristics of the zero voltage switching (ZVS) and zero voltage transition (ZVT) soft-switching applied in the 3-phase current fed dual active bridge (3P-CFDAB) converter, which combines the advantages of the dual active bridge (DAB) converter and current-fed full bridge (CFFB) converter. When an active clamp circuit is added to the CFFB converter, the circuit configuration of the DAB converter is shown in part of the entire circuit. This allows the use of pulse width modulation (PWM) techniques which combine the PWM techniques of both the DAB converter and CFFB converter. The proposed converter performs both duty and phase control at the same time in order to reduce the circulating current and ripple current of the output capacitor, which are the disadvantages of the CFFB converter and DAB converter. In addition, the ZVS and ZVT soft switching areas were analyzed by means of the phase current and leakage inductor current in each transformers. To verify the principle and feasibility of the proposed operation techniques, a simulation and experiment were implemented with the 3P-CFDAB.
- 23 September 2018
- Published by MDPI AG in Electronics
- Vol. 7 (10) , 214
Open AccessA Control Strategy for Bidirectional Isolated 3-Phase Current-Fed Dual Active Bridge Converter
This paper examines the characteristics of the zero voltage switching (ZVS) and zero voltage transition (ZVT) soft-switching applied in the 3-phase current fed dual active bridge (3P-CFDAB) converter, which combines the advantages of the dual active bridge (DAB) converter and current-fed full bridge (CFFB) converter. When an active clamp circuit is added to the CFFB converter, the circuit configuration of the DAB converter is shown in part of the entire circuit. This allows the use of pulse width modulation (PWM) techniques which combine the PWM techniques of both the DAB converter and CFFB converter. The proposed converter performs both duty and phase control at the same time in order to reduce the circulating current and ripple current of the output capacitor, which are the disadvantages of the CFFB converter and DAB converter. In addition, the ZVS and ZVT soft switching areas were analyzed by means of the phase current and leakage inductor current in each transformers. To verify the principle and feasibility of the proposed operation techniques, a simulation and experiment were implemented with the 3P-CFDAB.
- Open Access
- 29 August 2018
- Published by MDPI AG in Electronics
- Vol. 7 (9) , 167
Improved Neutral-Point Voltage-Shifting Strategy for Power Balancing in Cascaded NPC/H-Bridge Inverter
This paper investigates the fault-tolerance control of a multilevel cascaded NPC/H-bridge (CNHB) inverter. The fault-tolerance control method has been widely used for multilevel inverters, such as the neutral-point voltage-shifting control, which can operate for a certain period of time by compensating for the phase voltage of a faulty stack even if one stack is broken. Even though the three-phase equilibrium is maintained in the case of failure by using the conventional neutral-point voltage-shifting control, an imbalance in the output power occurs between each stack, which causes problems for maintenance and lifetime. Therefore, this paper proposes a fault-tolerance control that can maintain three-phase equilibrium in a case of stack failures and minimize power imbalances between the stacks. The problem of the conventional neutral-point voltage-shifting control is presented based on the output power. In addition, the power imbalance is improved by performing selective neutral-point voltage-shifting control according to the reference voltage range. To verify the principle and feasibility of the proposed neutral-point voltage-shifting control method, a simulation and an experiment are implemented with the CNHB inverter.
- 29 August 2018
- Published by MDPI AG in Electronics
- Vol. 7 (9) , 167
Open AccessImproved Neutral-Point Voltage-Shifting Strategy for Power Balancing in Cascaded NPC/H-Bridge Inverter
This paper investigates the fault-tolerance control of a multilevel cascaded NPC/H-bridge (CNHB) inverter. The fault-tolerance control method has been widely used for multilevel inverters, such as the neutral-point voltage-shifting control, which can operate for a certain period of time by compensating for the phase voltage of a faulty stack even if one stack is broken. Even though the three-phase equilibrium is maintained in the case of failure by using the conventional neutral-point voltage-shifting control, an imbalance in the output power occurs between each stack, which causes problems for maintenance and lifetime. Therefore, this paper proposes a fault-tolerance control that can maintain three-phase equilibrium in a case of stack failures and minimize power imbalances between the stacks. The problem of the conventional neutral-point voltage-shifting control is presented based on the output power. In addition, the power imbalance is improved by performing selective neutral-point voltage-shifting control according to the reference voltage range. To verify the principle and feasibility of the proposed neutral-point voltage-shifting control method, a simulation and an experiment are implemented with the CNHB inverter.
- Open Access
- 16 August 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (8) , 1387
A Study on Stability Control of Grid Connected DC Distribution System Based on Second Order Generalized Integrator-Frequency Locked Loop (SOGI-FLL)
This paper studies a second order generalized integrator-frequency locked loop (SOGI-FLL) control scheme applicable for 3-phase alternating current/direct current (AC/DC) pulse width modulation (PWM) converters used in DC distribution systems. The 3-phase AC/DC PWM converter is the most important power conversion system of DC distribution, since it can boost 380 Vrms 3-phase line-to-line AC voltage to 700 Vdc DC output with various DC load devices and grid voltages. The direct-quadrature (d-q) transformation, positive sequence voltage extraction, proportional integral (PI) voltage/current control, and phase locked loop (PLL) are necessary to control the 3-phase AC/DC PWM converter. Besides, a digital filter, such as low pass filter and all pass filter, are essential in the conventional synchronous reference frame-phase locked loop (SRF-PLL) method to eliminate the low order harmonics of input. However, they limit the bandwidth of the controller, which directly affects the output voltage and load of 3-phase AC/DC PWM converter when sever voltage fluctuation, such as sag, swell, etc. occurred in the grid. On the other hand, the proposed control method using SOGI-FLL is able to do phase angle detection, positive sequence voltage extraction, and harmonic filtering without additional digital filters, so that more stable and fast transient control is achieved in the DC distribution system. To verify the improvement of the characteristics in the unbalanced voltage and frequency fluctuation of the grid, a simulation and experiment are implemented with 50 kW 3-phase AC/DC PWM converter used in DC distribution.
- 16 August 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (8) , 1387
Open AccessA Study on Stability Control of Grid Connected DC Distribution System Based on Second Order Generalized Integrator-Frequency Locked Loop (SOGI-FLL)
This paper studies a second order generalized integrator-frequency locked loop (SOGI-FLL) control scheme applicable for 3-phase alternating current/direct current (AC/DC) pulse width modulation (PWM) converters used in DC distribution systems. The 3-phase AC/DC PWM converter is the most important power conversion system of DC distribution, since it can boost 380 Vrms 3-phase line-to-line AC voltage to 700 Vdc DC output with various DC load devices and grid voltages. The direct-quadrature (d-q) transformation, positive sequence voltage extraction, proportional integral (PI) voltage/current control, and phase locked loop (PLL) are necessary to control the 3-phase AC/DC PWM converter. Besides, a digital filter, such as low pass filter and all pass filter, are essential in the conventional synchronous reference frame-phase locked loop (SRF-PLL) method to eliminate the low order harmonics of input. However, they limit the bandwidth of the controller, which directly affects the output voltage and load of 3-phase AC/DC PWM converter when sever voltage fluctuation, such as sag, swell, etc. occurred in the grid. On the other hand, the proposed control method using SOGI-FLL is able to do phase angle detection, positive sequence voltage extraction, and harmonic filtering without additional digital filters, so that more stable and fast transient control is achieved in the DC distribution system. To verify the improvement of the characteristics in the unbalanced voltage and frequency fluctuation of the grid, a simulation and experiment are implemented with 50 kW 3-phase AC/DC PWM converter used in DC distribution.
- Open Access
- 29 July 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (8) , 1251
An Adaptive Rapid Charging Method for Lithium-Ion Batteries with Compensating Cell Degradation Behavior
Recent developments in high-density lithium-ion battery technologies have greatly expanded the electric vehicle (EV) market. Due to the fact that the rapid charging of an EV battery pack while maintaining a suitable cell cycle life is necessary for further growth of the EV market, we herein propose an innovative adaptive rapid charging pattern that minimizes cell degradation and reflects the degradation characteristics. This technology is advantageous in that cells can be developed by analyzing the charging characteristics in the latter stages of cell development of the rapid charging pattern, while also considering the complexity and heterogeneity of the manufacturing process. Furthermore, the battery charging pattern is optimized and controlled in real-time by reflecting the characteristics of the battery module and pack degradation as the cycle number is increased. More specifically, we present a preliminary study that simplifies the implementation of the new optimization pattern to improve the cell cycle life by over 45% in comparison to conventional fast charging patterns, and to address the drop in capacity in the latter half of cell life during rapid charging.
- 29 July 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (8) , 1251
Open AccessAn Adaptive Rapid Charging Method for Lithium-Ion Batteries with Compensating Cell Degradation Behavior
Recent developments in high-density lithium-ion battery technologies have greatly expanded the electric vehicle (EV) market. Due to the fact that the rapid charging of an EV battery pack while maintaining a suitable cell cycle life is necessary for further growth of the EV market, we herein propose an innovative adaptive rapid charging pattern that minimizes cell degradation and reflects the degradation characteristics. This technology is advantageous in that cells can be developed by analyzing the charging characteristics in the latter stages of cell development of the rapid charging pattern, while also considering the complexity and heterogeneity of the manufacturing process. Furthermore, the battery charging pattern is optimized and controlled in real-time by reflecting the characteristics of the battery module and pack degradation as the cycle number is increased. More specifically, we present a preliminary study that simplifies the implementation of the new optimization pattern to improve the cell cycle life by over 45% in comparison to conventional fast charging patterns, and to address the drop in capacity in the latter half of cell life during rapid charging.
- Open Access
An Enhanced Control Scheme Based on New Adaptive Filters for Cascaded NPC/H-Bridge System
This paper studies the voltage fluctuation of dc-link generated in a 13-level cascaded neutral point clamped (NPC)/h-bridge (CNHB) with single-phase active front end (AFE) at the input side of each cell. The voltage fluctuation may deteriorate the power factor (PF) and current harmonics in the system. In this paper, new adaptive filters are proposed to overcome the problem. The center frequency of the proposed filters can be automatically varied, which allows to eliminate the specific harmonics in the dc-link well rather than the conventional one. Therefore, it can reduce the fluctuation of dc-link and maintain high PF and low current harmonic distortion without additional circuits externally or the current harmonics injection technique. As a result, capacitance for the dc-link can be optimally designed, and even cost and volume of the system can be reduced. This paper analyzes reasons of increasing voltage fluctuation theoretically and the conventional filter and proposed two types of adaptive filters are compared. In addition, the optimal design method of the dc-link capacitor necessarily used in NPC/h-bridge is presented. To verify the principle and feasibility of the proposed control method, a simulation and experiment are implemented with the CNHB system.
Open AccessAn Enhanced Control Scheme Based on New Adaptive Filters for Cascaded NPC/H-Bridge System
This paper studies the voltage fluctuation of dc-link generated in a 13-level cascaded neutral point clamped (NPC)/h-bridge (CNHB) with single-phase active front end (AFE) at the input side of each cell. The voltage fluctuation may deteriorate the power factor (PF) and current harmonics in the system. In this paper, new adaptive filters are proposed to overcome the problem. The center frequency of the proposed filters can be automatically varied, which allows to eliminate the specific harmonics in the dc-link well rather than the conventional one. Therefore, it can reduce the fluctuation of dc-link and maintain high PF and low current harmonic distortion without additional circuits externally or the current harmonics injection technique. As a result, capacitance for the dc-link can be optimally designed, and even cost and volume of the system can be reduced. This paper analyzes reasons of increasing voltage fluctuation theoretically and the conventional filter and proposed two types of adaptive filters are compared. In addition, the optimal design method of the dc-link capacitor necessarily used in NPC/h-bridge is presented. To verify the principle and feasibility of the proposed control method, a simulation and experiment are implemented with the CNHB system.
- 20 December 2016
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 21 (6) , 486-496
Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality
Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality 3-level AC/DC converter;LVDC distribution system;Bipolar voltage control; The voltage unbalance of an LVDC bipolar distribution system was controlled for high power quality. Voltage unbalance may occur in a bipolar distribution system depending on the operation of the converter and load usage. Voltage unbalance can damage sensitive load and lead to converter accidents. The conditions that may cause voltage unbalance in a bipolar distribution system are as follows. First, three-level AC/DC converters in bipolar distribution systems can lead to voltage unbalance. Second, bipolar distribution systems can be at risk for voltage unbalance because of load usage. In this paper, the output DC link of a three-level AC/DC converter was analyzed for voltage unbalance, and the bipolar voltage was controlled with algorithms. In the case of additional voltage unbalance according to load usage, the bipolar voltage was controlled using the proposed converter. The proposed converter is a dual half-bridge converter, which was improved from the secondary circuit of a dual half-bridge converter. A control algorithm for bipolar voltage control without additional converters was proposed. The balancing control of the bipolar distribution system with distributed power was verified through experiments.
- 20 December 2016
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 21 (6) , 486-496
Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality
Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality 3-level AC/DC converter;LVDC distribution system;Bipolar voltage control; The voltage unbalance of an LVDC bipolar distribution system was controlled for high power quality. Voltage unbalance may occur in a bipolar distribution system depending on the operation of the converter and load usage. Voltage unbalance can damage sensitive load and lead to converter accidents. The conditions that may cause voltage unbalance in a bipolar distribution system are as follows. First, three-level AC/DC converters in bipolar distribution systems can lead to voltage unbalance. Second, bipolar distribution systems can be at risk for voltage unbalance because of load usage. In this paper, the output DC link of a three-level AC/DC converter was analyzed for voltage unbalance, and the bipolar voltage was controlled with algorithms. In the case of additional voltage unbalance according to load usage, the bipolar voltage was controlled using the proposed converter. The proposed converter is a dual half-bridge converter, which was improved from the secondary circuit of a dual half-bridge converter. A control algorithm for bipolar voltage control without additional converters was proposed. The balancing control of the bipolar distribution system with distributed power was verified through experiments.