KMKenji Mishima

Kenji Mishima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kenji Mishima has a total of 665 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development and characterization of low-scattering vanadium nanoparticle targets for short-range interaction searches

    by Masayuki Hiromoto, Tatsushi Shima, Christopher C. Haddock, Katsuya Hirota, Masaaki Kitaguchi, Ryota Kondo, Rintaro Nakabe, Kenji Mishima, Hirohiko M. Shimizu, Yuki Yoshikawa, et al.

  • Open Access

    Current status of multilayer neutron interferometry with gaseous samples at J-PARC

    by Taro Nambu, Clayton J. Auton, Takuhiro Fujiie, Masahiro Hino, Takuya Hosobata, Go Ichikawa, Masaaki Kitaguchi, Anna L. McElhannon, Kenji Mishima, Yoshichika Seki, et al.

    Several few-body nuclear models, such as the Argonne v 18 potential including three-nucleon forces and chiral effective field theories, predict the coherent scattering length ( b c ) for light nuclei. Reliable measurements of b c therefore provide important tests of these models. We have developed a measurement system for determining b c of gaseous samples using a multilayer-type neutron interferometer at J-PARC, and successfully observed the phase shifts of 3 He and 4 He gases. From the observed phase shifts, we obtained for 3 He b c = 3.99 ± 0.23 (stat.) ± 0.66 (sys.) fm and for 4 He b c = 2.95 ± 0.11 (stat.) ± 0.67 (sys.) fm (stat. and sys. denote statistical uncertainty and systematic uncertainty, respectively). To achieve higher precision, we are currently upgrading the experimental setup.

  • Proof-of-principle experiment on a displacement-noise-free neutron interferometer for gravitational wave detection

    by Shoki Iwaguchi, Takuhiro Fujiie, Taro Nambu, Masaaki Kitaguchi, Yutaka Yamagata, Kenji Mishima, Atsushi Nishizawa, Tomohiro Ishikawa, Kenji Tsuji, Kurumi Umemura, et al.

    The displacement-noise-free interferometer (DFI) is designed to eliminate all displacement-induced noise while retaining sensitivity to gravitational wave (GW) signals. Ground-based DFIs suffer from physical arm-length limitations, resulting in poor sensitivity at frequencies below 1 kHz. To address this, previous research introduced a neutron-based DFI, which replaces laser light with neutrons and achieves exceptional sensitivity down to a few hertz. In this study, we conducted a proof-of-principle experiment using a pulsed neutron source at the Japan Proton Accelerator Research Complex. Despite practical constraints that led to deviations from the ideal experimental design, we optimized the setup and developed a novel analysis method that successfully cancels displacement noise while preserving simulated GW signals. This work presents the first successful demonstration of a neutron DFI and a neutron interferometer for GW detection.

  • Open Access

    Measurement of neutron whispering gallery states using a pulsed neutron beam

    by G. Ichikawa, K. Mishima

    A neutron whispering gallery state is a quantum state localized on a material surface bound by the centrifugal force and the material potential. Precise measurements of such quantum states enable tests of quantum mechanics in noninertial frames, characterization of the surface potential, and searches for hypothetical short-range interactions at the nanometer scale. We observed a neutron whispering gallery state on a SiO 2 concave mirror using a pulsed cold neutron beam. The measured results agree with theoretical calculations within 1.9% for the centrifugal acceleration a ≈ 7 × 10 7 m / s 2 , which is due to unmodeled deviations of the shape of the concave mirror edge from an ideal one. We found that the sensitivity itself was 1 × 10 − 4 , which is two orders of magnitude better than the above agreement.


  • Open Access

    Simulation Study on Dose and LET of Neutron Irradiation for Biological Experiments Using Spallation, Reactor, and Compact Neutron Sources

    by May Sweet, Kenji Mishima, Masahide Harada, Keisuke Kurita, Hiroshi Iikura, Seiji Tasaki, Norio Kikuchi

    Neutron beams, being electrically neutral and highly penetrating, offer unique advantages for the irradiation of biological species such as plants, seeds, and microorganisms. We comprehensively investigated the potential of neutron irradiation for inducing genetic mutations by using simulations of spallation, reactor, and compact neutron sources based on J-PARC BL10, the JRR-3 TNRF, and KUANS. We analyzed neutron flux, energy deposition rates, and Linear Energy Transfer (LET) distributions. The KUANS simulation demonstrated the highest dose rate of 17 Gy/h, significantly surpassing that obtained at BL10, due to the large solid angle achieved with optimal sample placement. The findings highlight KUANS’s suitability for efficiently inducing specific genetic mutations and neutron breeding, particularly for inducing targeted mutations in biological samples, also on account of its LET range of 20–70 keV/μm. Our results emphasize the importance of choosing neutron sources based on LET requirements to maximize mutation induction efficiency. This research study shows the potential of compact neutron sources such as KUANS for effective biological irradiation and neutron breeding, offering a viable alternative to larger facilities. The neutron filters used at BL10 and the TNRF effectively exclude low-energy neutrons while keeping the high-LET component. The neutron capture reaction, 14N(n,p)14C, was found to be the main dose contributor under thermal neutron-dominated conditions.


  • Open Access

    Improved measurements of neutron lifetime with cold neutron beam at J-PARC

    by Y. Fuwa, T. Hasegawa, K. Hirota, T. Hoshino, R. Hosokawa, G. Ichikawa, S. Ieki, T. Ino, Y. Iwashita, M. Kitaguchi, et al.

    The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $τ_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$σ$ tension with the average value obtained from the proton-detection-based beam method.


  • Polarized Cold-neutron Reflectometry at JRR-3/MINE2 for the Development of Ultracold-neutron Spin Analyzers for a Neutron EDM Experiment at TRIUMF

    by Takashi Higuchi, Hiroaki Akatsuka, Alexis Brossard, Derek Fujimoto, Pietro Giampa, Sean Hansen-Romu, Kichiji Hatanaka, Masahiro Hino, Go Ichikawa, Sohei Imajo, et al.


  • Open Access

    Performance of the Fully Equipped Spin Flip Chopper for the Neutron Lifetime Experiment at J-PARC

    by K Mishima, G Ichikawa, Y Fuwa, T Hasegawa, M Hino, R Hosokawa, T Ino, Y Iwashita, M Kitaguchi, S Matsuzaki, et al.

    To solve the “neutron lifetime puzzle,” where measured neutron lifetimes differ depending on the measurement methods, an experiment with a pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250–400, which is comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in the statistics will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.


  • Development of Neutron Interferometer Using Multilayer Mirrors and Measurements of Neutron-Nuclear Scattering Length with Pulsed Neutron Source

    by Takuhiro Fujiie, Masahiro Hino, Takuya Hosobata, Go Ichikawa, Masaaki Kitaguchi, Kenji Mishima, Yoshichika Seki, Hirohiko M. Shimizu, Yutaka Yamagata

    This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min recording time. Compared to systems using silicon crystals, the measurement sensitivity was maintained even when using a simplified disturbance suppressor. By segregating beam paths entirely, we achieved successful measurements of neutron-nuclear scattering lengths across various samples. The values measured for Si, Al, and Ti were in agreement with those found in the literature, while V showed a disparity of 45%. This discrepancy may be attributable to impurities encountered in previous investigations. The accuracy of measurements can be enhanced further by mitigating systematic uncertainties that are associated with neutron wavelength, sample impurity, and thickness. This novel neutron interferometer enables us to measure fundamental parameters, such as the neutron-nuclear scattering length of materials, with a precision that surpasses that of conventional interferometers.


  • Diffuse scattering model of ultracold neutrons on wavy surfaces

    by S. Imajo, H. Akatsuka, K. Hatanaka, T. Higuchi, G. Ichikawa, S. Kawasaki, M. Kitaguchi, R. Mammei, R. Matsumiya, K. Mishima, et al.

    Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments that use ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to an average roughness of 25–150nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness greater than 5nm. We, therefore, developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as an input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source in J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than ±6∘ was directed into a guide tube with a mean-square roughness of 6.4 to 17nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability pL=0.039±0.003 reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10nm.