Performance of the Fully Equipped Spin Flip Chopper for the Neutron Lifetime Experiment at J-PARC
Open Access
- 9 August 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2024 (9)
Abstract
To solve the “neutron lifetime puzzle,” where measured neutron lifetimes differ depending on the measurement methods, an experiment with a pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250–400, which is comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in the statistics will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.Keywords
All Related Versions
Funding Information
- Japan Society for the Promotion of Science (16H02194, 19H00690, 22H00140)
- Kyoto University (30086, 31030)
This publication has 25 references indexed in Scilit:
- The LiNA experiment: Development of multi-layered time projection chamberNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- Development and application of a He Neutron Spin Filter at J-PARCNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- Depolarization in polarizing supermirrorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beamsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Measurement of the neutron beam polarization of BL05/NOP beamline at J-PARCPhysica B: Condensed Matter, 2011
- LET, a cold neutron multi-disk chopper spectrometer at ISISNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- A high S/N ratio spin flip chopper system for a pulsed neutron sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Design of neutron beamline for fundamental physics at J-PARC BL05Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Recent development of multilayer neutron mirror at KURRINuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Neutron spin flip chopper with very high S/N ratio for pulsed sourcePhysica B: Condensed Matter, 2003