MMMasato Matsuura

Masato Matsuura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masato Matsuura has a total of 80 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroshi Murata

    Department of Ophthalmology, University of Tokyo, Tokyo, Japan

    13 shared publications
  • Yuri Fujino

    Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan

    12 shared publications
  • Ryo Asaoka

    Affiliations Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan, Seirei Christopher University, Hamamatsu, Shizuoka, Japan, The Graduate School for the Creation of New Photonics Industries, Shizuoka, Japan, Organization for Innovation and Social Collaboration, National University Corporation Shizuoka University, Hamamatsu, Shizuoka, Japan

    11 shared publications
  • Kazuhiko Mori

    Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kawaramachi-Hirokoji, Kajii-cho, Kamigyo-ku, Kyoto, Japan

    6 shared publications
  • Kazunori Hirasawa

    Department of Ophthalmology, Kitasato University School of Medicine, Sagamihara, Japan

    5 shared publications
  • Atsuya Miki

    Department of Ophthalmology, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan

    4 shared publications

Latest Publications

  • Deep learning-assisted (automatic) diagnosis of glaucoma using a smartphone

    by Kenichi Nakahara, Ryo Asaoka, Masaki Tanito, Naoto Shibata, Keita Mitsuhashi, Yuri Fujino, Masato Matsuura, Tatsuya Inoue, Keiko Azuma, Ryo Obata, et al.

    Background/aims To validate a deep learning algorithm to diagnose glaucoma from fundus photography obtained with a smartphone. Methods A training dataset consisting of 1364 colour fundus photographs with glaucomatous indications and 1768 colour fundus photographs without glaucomatous features was obtained using an ordinary fundus camera. The testing dataset consisted of 73 eyes of 73 patients with glaucoma and 89 eyes of 89 normative subjects. In the testing dataset, fundus photographs were acquired using an ordinary fundus camera and a smartphone. A deep learning algorithm was developed to diagnose glaucoma using a training dataset. The trained neural network was evaluated by prediction result of the diagnostic of glaucoma or normal over the test datasets, using images from both an ordinary fundus camera and a smartphone. Diagnostic accuracy was assessed using the area under the receiver operating characteristic curve (AROC). Results The AROC with a fundus camera was 98.9% and 84.2% with a smartphone. When validated only in eyes with advanced glaucoma (mean deviation value < −12 dB, N=26), the AROC with a fundus camera was 99.3% and 90.0% with a smartphone. There were significant differences between these AROC values using different cameras. Conclusion The usefulness of a deep learning algorithm to automatically screen for glaucoma from smartphone-based fundus photographs was validated. The algorithm had a considerable high diagnostic ability, particularly in eyes with advanced glaucoma.


  • Open Access

    Comparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm

    by Hiroshi Murata, Ryo Asaoka, Yuri Fujino, Masato Matsuura, Kazunori Hirasawa, Satoshi Shimada, Nobuyuki Shoji

    Background/aims We previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness. Method 122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms. Result Mean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s). Conclusion VBLR-VF reduced test duration while maintaining the same accuracy as the SITA-standard.


  • Validating the usefulness of sectorwise regression of visual field in the central 10°

    by Takashi Omoto, Hiroshi Murata, Yuri Fujino, Masato Matsuura, Takehiro Yamashita, Atsuya Miki, Yoko Ikeda, Kazuhiko Mori, Masaki Tanito, Ryo Asaoka

    Aim To evaluate the usefulness of the application of the clustering method to the trend analysis (sectorwise regression) in comparison with the pointwise linear regression (PLR). Methods This study included 153 eyes of 101 patients with open-angle glaucoma. With PLR, the total deviation (TD) values of the 10th visual field (VF) were predicted using the shorter VF sequences (from first 3 to 9) by extrapolating TD values against time in a pointwise manner. Then, 68 test points were stratified into 29 sectors. In each sector, the mean of TD values was calculated and allocated to all test points belonging to the sector. Subsequently, the TD values of the 10th VF were predicted by extrapolating the allocated TD value against time in a pointwise manner. Similar analyses were conducted to predict the 11th–16th VFs using the first 10 VFs. Results When predicting the 10th VF using the shorter sequences, the mean absolute error (MAE) values were significantly smaller in the sectorwise regression than in PLR. When predicting from the 11th and 16th VFs using the first 10 VFs, the MAE values were significantly larger in the sectorwise regression than in PLR when predicting the 11th VF; however, no significant difference was observed with other VF predictions. Conclusion Accurate prediction was achieved using the sectorwise regression, in particular when a small number of VFs were used in the prediction. The accuracy of the sectorwise regression was not hampered in longer follow-up compared with PLR.


  • Predicting the Glaucomatous Central 10-Degree Visual Field From Optical Coherence Tomography Using Deep Learning and Tensor Regression

    by Linchuan Xu, Ryo Asaoka, Taichi Kiwaki, Hiroshi Murata, Yuri Fujino, Masato Matsuura, Yohei Hashimoto, Shotaro Asano, Atsuya Miki, Kazuhiko Mori, et al.


  • Deep learning model to predict visual field in central 10° from optical coherence tomography measurement in glaucoma

    by Yohei Hashimoto, Ryo Asaoka, Taichi Kiwaki, Hiroki Sugiura, Shotaro Asano, Hiroshi Murata, Yuri Fujino, Masato Matsuura, Atsuya Miki, Kazuhiko Mori, et al.

    Background/Aim: To train and validate the prediction performance of the deep learning (DL) model to predict visual field (VF) in central 10° from spectral domain optical coherence tomography (SD-OCT). Methods: This multicentre, cross-sectional study included paired Humphrey field analyser (HFA) 10-2 VF and SD-OCT measurements from 591 eyes of 347 patients with open-angle glaucoma (OAG) or normal subjects for the training data set. We trained a convolutional neural network (CNN) for predicting VF threshold (TH) sensitivity values from the thickness of the three macular layers: retinal nerve fibre layer, ganglion cell layer+inner plexiform layer and outer segment+retinal pigment epithelium. We implemented pattern-based regularisation on top of CNN to avoid overfitting. Using an external testing data set of 160 eyes of 131 patients with OAG, the prediction performance (absolute error (AE) and R2 between predicted and actual TH values) was calculated for (1) mean TH in whole VF and (2) each TH of 68 points. For comparison, we trained support vector machine (SVM) and multiple linear regression (MLR). Results: AE of whole VF with CNN was 2.84±2.98 (mean±SD) dB, significantly smaller than those with SVM (5.65±5.12 dB) and MLR (6.96±5.38 dB) (all, p2 with CNN was 0.74 for the mean TH of whole VF, and 0.44±0.24 for the overall 68 points. Conclusion: DL model showed considerably accurate prediction of HFA 10-2 VF from SD-OCT.


  • Usefulness of data augmentation for visual field trend analyses in patients with glaucoma

    by Ryo Asaoka, Hiroshi Murata, Masato Matsuura, Yuri Fujino, Atsuya Miki, Masaki Tanito, Shiro Mizoue, Kazuhiko Mori, Katsuyoshi Suzuki, Takehiro Yamashita, et al.

    Aim To investigate the usefulness of data augmentation in visual field (VF) trend analyses in patients with glaucoma. Method This study included 6380 VFs from 638 eyes of 417 patients with open-angle glaucoma. Various affine transformations were applied to augment the VF data: (1) rotation, (2) scaling, (3) vertical and horizontal shift and (4) a combination of these different transformations. Using pointwise linear regression (PLR), the total deviation (TD) values of a patient’s 10th VF were predicted using TD values from shorter VF series (from first to third VFs (VF1–3) to first to ninth VFs (VF1–9)) with and without VF data augmentation, and the root mean squared error (RMSE) was calculated. Results With PLR, mean RMSE without VF augmentation averaged from 3.95 (VF1–3) to 19.01 (VF1–9) dB. The RMSE was significantly improved by applying the different transformations: (1) rotation (from VF1–3 to VF1–7), (2) scaling (from VF1–3 to VF1–6), (3) vertical and horizontal shifts (from VF1–3 to VF1–4) and (iv) a combination of these (from VF1–3 to VF1–7). Progression rates in VF1–10 had better agreement with those in shorter VF series when a combination of affine transformation was applied. The differences in rates were between 1.9 (VF1–3) and 0.39 (VF1–9) dB if augmentation was used, which was significantly smaller than that observed when augmentation was not applied (from 2.6 with VF1–3 to 0.26 dB with VF1–9). Conclusion It is useful to apply VF data augmentation techniques when predicting future VF progression in glaucoma using PLR, especially with short VF series.


  • Comment on Cataract Surgery and Rate of Visual Field Progression in Primary Open-Angle Glaucoma

    by Shuichiro Aoki, Hiroshi Murata, Shunsuke Nakakura, Yoshitaka Nakao, Masato Matsuura, Kazunori Hirasawa, Kana Tokumo, Yoshiaki Kiuchi, Ryo Asaoka


  • Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis

    by Masato Matsuura, Hiroshi Murata, Yuri Fujino, Mieko Yanagisawa, Yoshitaka Nakao, Kana Tokumo, Shunsuke Nakakura, Yoshiaki Kiuchi, Ryo Asaoka

    Aims Corvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA). Methods A total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis. Results IOPg, IOPcc and GAT IOP were significantly associated with CCT (pConclusion The bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.


  • Validating the efficacy of the binomial pointwise linear regression method to detect glaucoma progression with multicentral database

    by Shotaro Asano, Hiroshi Murata, Masato Matsuura, Yuri Fujino, Atsuya Miki, Masaki Tanito, Shiro Mizoue, Kazuhiko Mori, Katsuyoshi Suzuki, Takehiro Yamashita, et al.

    Background/aim We previously reported the benefit of applying binomial pointwise linear regression (PLR: binomial PLR) to detect 10–2 glaucomatous visual field (VF) progression. The purpose of the current study was to validate the usefulness of the binomial PLR to detect glaucomatous VF progression in the central 24°. Methods Series of 15 VFs (Humphrey Field Analyzer 24–2 SITA-standard) from 341 eyes of 233 patients, obtained over 7.9±2.1 years (mean±SD), were investigated. PLR was performed by regressing the total deviation of all test points. VF progression was determined from the VF test points analyses using the binomial test (one side, pResults The binomial PLR was comparable with PoPLR and mTD trend analyses in the positive predictive value (0.18–0.87), the negative predictive value (0.89–0.95) and the false positive rate (0.057–0.35) to evaluate glaucomatous VF progression. The time to classify progression with binomial PLR (5.8±2.8 years) was significantly shorter than those with mTD trend analysis (6.7±2.8 years) and PoPLR (6.6±2.7 years). Conclusions The binomial PLR method, which detected glaucomatous VF progression in the central 24° significantly earlier than PoPLR and mTD trend analyses, shows promise for improving our ability to detect visual field progression for clinical management of glaucoma and in clinical trials of new glaucoma therapies.