Won Jung Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Won Jung Yoon has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Heongkyu Ju
Department of Physics and Semiconductor Science, Gachon University, Seongnam-si 13120, Republic of Korea
7 shared publications - Nhu Hoa Thi Tran
Vietnam National University, Ho Chi Minh City 700000, Vietnam
3 shared publications - Kieu The Loan Trinh
Advanced Materials Technology Institute, Vietnam National University Ho Chi Minh City, Ho Chi Minh City 70000, Vietnam
2 shared publications - Vien Thi Tran
Department of Physics, Gachon University, Seongnam 13120, Korea
2 shared publications - Changjin Son
Friedrich-Alexander Universität Erlangen-Nürnberg
1 shared publication - Eunjoo Nam
Center for Neuroscience, KIST, Seoul 02792, Republic of Korea
1 shared publication
Latest Publications
- 16 November 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 6 (46) , 23894-23902
DNA sequence-induced modulation of bimetallic surface plasmons in optical fibers for sub-ppq (parts-per-quadrillion) detection of mercury ions in water
Hg 2+ detection sensitivity modulated by ssDNA sequence based binary numbers in bimetal-plasmonic optical fiber sensor that triggers ssDNA chemo-mechanical folding.
- 16 November 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 6 (46) , 23894-23902
DNA sequence-induced modulation of bimetallic surface plasmons in optical fibers for sub-ppq (parts-per-quadrillion) detection of mercury ions in water
Hg 2+ detection sensitivity modulated by ssDNA sequence based binary numbers in bimetal-plasmonic optical fiber sensor that triggers ssDNA chemo-mechanical folding.
- Open Access
- 5 October 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (10) , 506
A Plasmonic Fiber Based Glucometer and Its Temperature Dependence
We present the plasmonic fiber based optical glucometer. A thin gold layer is coated on clad-free core of multimode optical fiber along 3 cm length to excite surface plasmons at 632.8 nm wavelength. Glucose oxidase is immobilized on the metal surface for glucose sensing. The effective surface refractive index increases by gluconic acid and hydrogen peroxide that are generated upon glucose injection, leading to plasmonic condition change with a consequence of optical power change at the fiber output. We obtain limit of detection of glucose concentration of 6.75 mg/dL, indicating higher sensitivity than the wavelength interrogating SPR glucometer that uses a spectrometer of 1nm spectral resolution. The coefficient of variation is 8.6% at a glucose concentration of 80 mg/dL at room temperature. We also examine the effects of ambient temperature variations from −10 °C to 40 °C on the performance of the presented sensor and compared them with those on commercially available glucometers that are based on enzyme electrodes. We find that the presented fiber sensor produced standard deviation of 12.1 mg/dL at a glucose concentration of 80 mg/dL under such varying temperature, which is, even without additional temperature correction function, comparable to the commercialized ones.
- 5 October 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (10) , 506
Open AccessA Plasmonic Fiber Based Glucometer and Its Temperature Dependence
We present the plasmonic fiber based optical glucometer. A thin gold layer is coated on clad-free core of multimode optical fiber along 3 cm length to excite surface plasmons at 632.8 nm wavelength. Glucose oxidase is immobilized on the metal surface for glucose sensing. The effective surface refractive index increases by gluconic acid and hydrogen peroxide that are generated upon glucose injection, leading to plasmonic condition change with a consequence of optical power change at the fiber output. We obtain limit of detection of glucose concentration of 6.75 mg/dL, indicating higher sensitivity than the wavelength interrogating SPR glucometer that uses a spectrometer of 1nm spectral resolution. The coefficient of variation is 8.6% at a glucose concentration of 80 mg/dL at room temperature. We also examine the effects of ambient temperature variations from −10 °C to 40 °C on the performance of the presented sensor and compared them with those on commercially available glucometers that are based on enzyme electrodes. We find that the presented fiber sensor produced standard deviation of 12.1 mg/dL at a glucose concentration of 80 mg/dL under such varying temperature, which is, even without additional temperature correction function, comparable to the commercialized ones.
- Open Access
- 17 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 471
Liquid Cladding Mediated Optical Fiber Sensors for Copper Ion Detection
We present a label-free optical fiber based sensor device to detect copper ions (Cu2+) in water. A multimode optical fiber, with its polymer cladding removed along a 1-cm length, is used for the optical sensor head, where the injected Cu2+ in the liquid phase acts as a liquid cladding for the optical mode. The various Cu2+ concentrations modulate the numerical aperture (NA) of the liquid cladding waveguide part. The degree of NA mismatch between the liquid cladding and solid cladding guided parts gives rise to an optical power transmittance change, forming the sensing principle. The presented liquid cladding fiber sensor exhibits a minimum resolvable refractive index of 2.48 × 10−6. For Cu2+ detection, we functionalize the sensor head surface (fiber core) using chitosan conjugated ethylenediaminetetraacetic acid (EDTA) which captures Cu2+ effectively due to the enhanced chelating effects. We obtain a limit of detection of Cu2+ of 1.62 nM (104 ppt), which is significantly lower than the tolerable level in drinking water (~30 µM), and achieve a dynamic range of 1 mM. The simple structure of the sensor head and the sensing system ensures the potential capability of being miniaturized. This may allow for in-situ, highly-sensitive, heavy metal sensors in a compact format.
- 17 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 471
Open AccessLiquid Cladding Mediated Optical Fiber Sensors for Copper Ion Detection
We present a label-free optical fiber based sensor device to detect copper ions (Cu2+) in water. A multimode optical fiber, with its polymer cladding removed along a 1-cm length, is used for the optical sensor head, where the injected Cu2+ in the liquid phase acts as a liquid cladding for the optical mode. The various Cu2+ concentrations modulate the numerical aperture (NA) of the liquid cladding waveguide part. The degree of NA mismatch between the liquid cladding and solid cladding guided parts gives rise to an optical power transmittance change, forming the sensing principle. The presented liquid cladding fiber sensor exhibits a minimum resolvable refractive index of 2.48 × 10−6. For Cu2+ detection, we functionalize the sensor head surface (fiber core) using chitosan conjugated ethylenediaminetetraacetic acid (EDTA) which captures Cu2+ effectively due to the enhanced chelating effects. We obtain a limit of detection of Cu2+ of 1.62 nM (104 ppt), which is significantly lower than the tolerable level in drinking water (~30 µM), and achieve a dynamic range of 1 mM. The simple structure of the sensor head and the sensing system ensures the potential capability of being miniaturized. This may allow for in-situ, highly-sensitive, heavy metal sensors in a compact format.
- Open Access
- 12 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 460
Fluorescence Enhancement Using Bimetal Surface Plasmon-Coupled Emission from 5-Carboxyfluorescein (FAM)
We demonstrate the enhancement of fluorescence emission from a dye, 5-carboxyfluorescein (FAM), which couples with surface plasmons at the spectral channels of excitation and emission. Experiments and calculations revealed that bimetallic (gold-silver) plasmon, as compared to the monometallic ones, allowed such coupling to be enhanced, at both the spectral channels. We achieved the maximum fluorescence enhancement level of 46.5-fold, with markedly high reproducibility (coefficient of variation ~ 0.5%) at a FAM concentration of 10 nM. We also found that higher fluorescence enhancement was more likely to be reproducible. This encourages the use of this technology for practical applications in fluorescence-based biochemical assays. Moreover, we investigated a FAM concentration-dependent enhancement of fluorescence. It was found that fluorescence enhancement decreased and saturated at above 10 nM concentration possibly due to partial photo-bleaching of FAM molecules.
- 12 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 460
Open AccessFluorescence Enhancement Using Bimetal Surface Plasmon-Coupled Emission from 5-Carboxyfluorescein (FAM)
We demonstrate the enhancement of fluorescence emission from a dye, 5-carboxyfluorescein (FAM), which couples with surface plasmons at the spectral channels of excitation and emission. Experiments and calculations revealed that bimetallic (gold-silver) plasmon, as compared to the monometallic ones, allowed such coupling to be enhanced, at both the spectral channels. We achieved the maximum fluorescence enhancement level of 46.5-fold, with markedly high reproducibility (coefficient of variation ~ 0.5%) at a FAM concentration of 10 nM. We also found that higher fluorescence enhancement was more likely to be reproducible. This encourages the use of this technology for practical applications in fluorescence-based biochemical assays. Moreover, we investigated a FAM concentration-dependent enhancement of fluorescence. It was found that fluorescence enhancement decreased and saturated at above 10 nM concentration possibly due to partial photo-bleaching of FAM molecules.
Reproducible Enhancement of Fluorescence by Bimetal Mediated Surface Plasmon Coupled Emission for Highly Sensitive Quantitative Diagnosis of Double‐Stranded DNA
Plasmonic enhancement of fluorescence from SYBR Green I conjugated with a double‐stranded DNA (dsDNA) amplicon is demonstrated on polymerase chain reaction (PCR) products. Theoretical computation leads to use of the bimetallic (Au 2 nm–Ag 50 nm) surface plasmons due to larger local fields (higher quality factors) than monometallic (Ag or Au) ones at both dye excitation and emission wavelengths simultaneously, optimizing fluorescence enhancement with surface plasmon coupled emission (SPCE). Two kinds of reverse Kretschmann configurations are used, which favor, in signal‐to‐noise ratio, a fluorescence assay that uses optically dense buffer such as blood plasma. The fluorescence enhancement (12.9 fold at maximum) with remarkably high reproducibility (coefficient of variation (CV) < 1%) is experimentally demonstrated. This facilitates credible quantitation of enhanced fluorescence, however unlikely to obtain by localized surface plasmons. The plasmon‐induced optical gain of 46 dB due to SPCE‐active dye molecules is also estimated. The fluorescence enhancement technologies with PCR enables LOD of the dsDNA template concentration of ≈400 fg µL−1 (CV < 1%), the lowest ever reported in DNA fluorescence assay to date. SPCE also reduces photobleaching significantly. These technologies can be extended for a highly reproducible and sufficiently sensitive fluorescence assay with small volumes of analytes in multiplexed diagnostics.
Reproducible Enhancement of Fluorescence by Bimetal Mediated Surface Plasmon Coupled Emission for Highly Sensitive Quantitative Diagnosis of Double‐Stranded DNA
Plasmonic enhancement of fluorescence from SYBR Green I conjugated with a double‐stranded DNA (dsDNA) amplicon is demonstrated on polymerase chain reaction (PCR) products. Theoretical computation leads to use of the bimetallic (Au 2 nm–Ag 50 nm) surface plasmons due to larger local fields (higher quality factors) than monometallic (Ag or Au) ones at both dye excitation and emission wavelengths simultaneously, optimizing fluorescence enhancement with surface plasmon coupled emission (SPCE). Two kinds of reverse Kretschmann configurations are used, which favor, in signal‐to‐noise ratio, a fluorescence assay that uses optically dense buffer such as blood plasma. The fluorescence enhancement (12.9 fold at maximum) with remarkably high reproducibility (coefficient of variation (CV) < 1%) is experimentally demonstrated. This facilitates credible quantitation of enhanced fluorescence, however unlikely to obtain by localized surface plasmons. The plasmon‐induced optical gain of 46 dB due to SPCE‐active dye molecules is also estimated. The fluorescence enhancement technologies with PCR enables LOD of the dsDNA template concentration of ≈400 fg µL−1 (CV < 1%), the lowest ever reported in DNA fluorescence assay to date. SPCE also reduces photobleaching significantly. These technologies can be extended for a highly reproducible and sufficiently sensitive fluorescence assay with small volumes of analytes in multiplexed diagnostics.
- Open Access
- 19 February 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (14) , 7855-7862
Blood-based immunoassay of tau proteins for early diagnosis of Alzheimer's disease using surface plasmon resonance fiber sensors
We present the immunoassay of tau proteins (total tau and phosphorylated tau) in human sera using surface plasmon resonance (SPR) fiber sensors. This assay aimed at harvesting the advantages of using both SPR fiber sensors and a blood-based assay to demonstrate label-free point-of-care-testing (POCT) patient-friendly assay in a compact format for the early diagnosis of Alzheimer's disease (AD). For conducting the assay, we used human sera of 40 subjects divided into halves, which were grouped into AD patients and control groups according to a number of neuropsychological tests. We found that on an average, the concentrations of both total tau and phosphorylated tau proteins (all known to be higher in cerebrospinal fluid (CSF) and the brain) turned out to be higher in human sera of AD patients than in controls. The limits of detection of total tau and phosphorylated tau proteins were 2.4 pg mL−1 and 1.6 pg mL−1, respectively. In particular, it was found that the AD group exhibited average concentration of total tau proteins 6-fold higher than the control group, while concentration of phosphorylated tau proteins was 3-fold higher than that of the control. We can attribute this inhomogeneity between both types of tau proteins (in terms of increase of control-to-AD in average concentration) to un-phosphorylated tau proteins being more likely to be produced in blood than phosphorylated tau proteins, which possibly is one of the potential key elements playing an important role in AD progress.
- 19 February 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (14) , 7855-7862
Open AccessBlood-based immunoassay of tau proteins for early diagnosis of Alzheimer's disease using surface plasmon resonance fiber sensors
We present the immunoassay of tau proteins (total tau and phosphorylated tau) in human sera using surface plasmon resonance (SPR) fiber sensors. This assay aimed at harvesting the advantages of using both SPR fiber sensors and a blood-based assay to demonstrate label-free point-of-care-testing (POCT) patient-friendly assay in a compact format for the early diagnosis of Alzheimer's disease (AD). For conducting the assay, we used human sera of 40 subjects divided into halves, which were grouped into AD patients and control groups according to a number of neuropsychological tests. We found that on an average, the concentrations of both total tau and phosphorylated tau proteins (all known to be higher in cerebrospinal fluid (CSF) and the brain) turned out to be higher in human sera of AD patients than in controls. The limits of detection of total tau and phosphorylated tau proteins were 2.4 pg mL−1 and 1.6 pg mL−1, respectively. In particular, it was found that the AD group exhibited average concentration of total tau proteins 6-fold higher than the control group, while concentration of phosphorylated tau proteins was 3-fold higher than that of the control. We can attribute this inhomogeneity between both types of tau proteins (in terms of increase of control-to-AD in average concentration) to un-phosphorylated tau proteins being more likely to be produced in blood than phosphorylated tau proteins, which possibly is one of the potential key elements playing an important role in AD progress.
- Open Access
- 2 September 2014
- Published by Springer Nature in Discover Nano
- Vol. 9 (1) , 460
Optimization of an organic photovoltaic device via modulation of thickness of photoactive and optical spacer layers
We examine the modulation effects of thicknesses of both a photoactive layer (a bulk-heterojunction (BHJ) of poly(3-hexylthiophene) and [6,6]-phenyl-C61-butyric acid methyl ester (P3HT:PCBM)) and an optical spacer of a transparent metal oxide, for power conversion efficiency optimization of organic photovoltaic devices. The redistribution of the optical intensity at the photoactive layer via the thickness modulation of both layers is taken into account, to produce three-dimensional (3D) plots as a function of both layer thicknesses of 0 to 400 nm range (5 nm step), for the device efficiency optimization. The modulation pattern of absorption is produced in the 3D plot as scanning the thicknesses of both layers as a result of modulation of interference between incoming and reflected light, which can be secured by changing the effective optical path length between two electrodes of a photovoltaic device. It is also seen that the case of inserting the spacer of the higher refractive index demands finer adjustment of the spacer layer thickness to achieve the optimum device efficiency. In addition, the series resistance of the photoactive layer of the thickness range of 0 to 70 nm is taken into account to provide the 3D plots as a function of the scanned thicknesses of both layers. Inclusion of the series resistance of the photoactive layer, which is also the function of its thickness, in the simulation, indicates that the series resistance can influence qualitatively the dependence of power conversion efficiency (PCE) on the thicknesses of both layers. We also find that minimization of series resistance, e.g., by device annealing, allows not only the relevant voltage to increase but also the optimum thickness of the photoactive layer to increase, leading to more absorption of light.
- 2 September 2014
- Published by Springer Nature in Discover Nano
- Vol. 9 (1) , 460
Open AccessOptimization of an organic photovoltaic device via modulation of thickness of photoactive and optical spacer layers
We examine the modulation effects of thicknesses of both a photoactive layer (a bulk-heterojunction (BHJ) of poly(3-hexylthiophene) and [6,6]-phenyl-C61-butyric acid methyl ester (P3HT:PCBM)) and an optical spacer of a transparent metal oxide, for power conversion efficiency optimization of organic photovoltaic devices. The redistribution of the optical intensity at the photoactive layer via the thickness modulation of both layers is taken into account, to produce three-dimensional (3D) plots as a function of both layer thicknesses of 0 to 400 nm range (5 nm step), for the device efficiency optimization. The modulation pattern of absorption is produced in the 3D plot as scanning the thicknesses of both layers as a result of modulation of interference between incoming and reflected light, which can be secured by changing the effective optical path length between two electrodes of a photovoltaic device. It is also seen that the case of inserting the spacer of the higher refractive index demands finer adjustment of the spacer layer thickness to achieve the optimum device efficiency. In addition, the series resistance of the photoactive layer of the thickness range of 0 to 70 nm is taken into account to provide the 3D plots as a function of the scanned thicknesses of both layers. Inclusion of the series resistance of the photoactive layer, which is also the function of its thickness, in the simulation, indicates that the series resistance can influence qualitatively the dependence of power conversion efficiency (PCE) on the thicknesses of both layers. We also find that minimization of series resistance, e.g., by device annealing, allows not only the relevant voltage to increase but also the optimum thickness of the photoactive layer to increase, leading to more absorption of light.