KKKirsten Koolstra

Kirsten Koolstra

*This is an algorithmically generated author record based on publicly available information.

Kirsten Koolstra has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Chemical shift–encoded multishot EPI for navigator‐free prostate DWI

    by Yiming Dong, David Atkinson, Kirsten Koolstra, Matthias J. P. van Osch, Peter Börnert

    Purpose: DWI is an important contrast for prostate MRI to enable early and accurate detection of cancer. This study introduces a Dixon 3‐shot‐EPI protocol with structured low‐rank reconstruction for navigator‐free DWI. The aim is to overcome the limitations of single‐shot EPI (ssh‐EPI), such as geometric distortions and fat signal interference, while addressing the motion‐induced phase variations of multishot EPI and simultaneously allowing water/fat separation.Methods: DWI data were acquired from 7 healthy volunteers using both Dixon 3‐shot EPI and standard fat‐suppressed ssh‐EPI with similar scan times for comparison. Two readers evaluated image quality using a 5‐point Likert scale regarding different aspects. The ADC values were quantitatively compared between protocols. To show feasibility in a clinical setting, the protocol was applied to two patients.Results: From the reader scores, Dixon 3‐shot EPI significantly reduced geometric distortion compared with ssh‐EPI (p < 0.01), with no significant differences in edge definition, SNR, or overall image quality. There was no significant difference in ADC values between the two protocols. However, the Dixon multishot‐EPI protocol offered advantages such as self‐referenced B0 map–driven distortion correction, greater flexibility in imaging parameters, and superior fat suppression. In the patient data, the lesion could be clearly identified in both protocols and on the associated ADC maps.Conclusion: The proposed Dixon 3‐shot‐EPI protocol shows promise as an alternative to ssh‐EPI for prostate DWI, providing reduced geometric distortions and improved fat suppression. It addresses common DWI issues based on EPI and enhances scanning flexibility, indicating potential for optimized imaging.


  • Open Access

    Structured low‐rank reconstruction for navigator‐free water/fat separated multi‐shot diffusion‐weightedEPI

    by Yiming Dong, Kirsten Koolstra, Ziyu Li, Malte Riedel, Matthias J. P. van Osch, Peter Börnert

    Purpose: Multi‐shot diffusion‐weighted EPI allows an increase in image resolution and reduced geometric distortions and can be combined with chemical‐shift encoding (Dixon) to separate water/fat signals. However, such approaches suffer from physiological motion‐induced shot‐to‐shot phase variations. In this work, a structured low‐rank‐based navigator‐free algorithm is proposed to address the challenge of simultaneously separating water/fat signals and correcting for physiological motion‐induced shot‐to‐shot phase variations in multi‐shot EPI‐based diffusion‐weighted MRI.Theory and Methods: We propose an iterative, model‐based reconstruction pipeline that applies structured low‐rank regularization to estimate and eliminate the shot‐to‐shot phase variations in a data‐driven way, while separating water/fat images. The algorithm is tested in different anatomies, including head–neck, knee, brain, and prostate. The performance is validated in simulations and in‐vivo experiments in comparison to existing approaches.Results: In‐vivo experiments and simulations demonstrated the effectiveness of the proposed algorithm compared to extra‐navigated and an alternative self‐navigation approach. The proposed algorithm demonstrates the capability to reconstruct in the multi‐shot/Dixon hybrid space domain under‐sampled datasets, using the same number of acquired EPI shots compared to conventional fat‐suppression techniques but eliminating fat signals through chemical‐shift encoding. In addition, partial Fourier reconstruction can also be achieved by using the concept of virtual conjugate coils in conjunction with the proposed algorithm.Conclusion: The proposed algorithm effectively eliminates the shot‐to‐shot phase variations and separates water/fat images, making it a promising solution for future DWI on different anatomies.


  • Open Access

    3D magnetic resonance fingerprinting on a low-field 50 mT point-of-care system prototype: evaluation of muscle and lipid relaxation time mapping and comparison with standard techniques

    by Thomas O’rEilly, Peter Börnert, Hongyan Liu, Andrew Webb, Kirsten Koolstra

    Objective: To implement magnetic resonance fingerprinting (MRF) on a permanent magnet 50 mT low-field system deployable as a future point-of-care (POC) unit and explore the quality of the parameter maps. Materials and methods: 3D MRF was implemented on a custom-built Halbach array using a slab-selective spoiled steady-state free precession sequence with 3D Cartesian readout. Undersampled scans were acquired with different MRF flip angle patterns and reconstructed using matrix completion and matched to the simulated dictionary, taking excitation profile and coil ringing into account. MRF relaxation times were compared to that of inversion recovery (IR) and multi-echo spin echo (MESE) experiments in phantom and in vivo. Furthermore, B0 inhomogeneities were encoded in the MRF sequence using an alternating TE pattern, and the estimated map was used to correct for image distortions in the MRF images using a model-based reconstruction. Results: Phantom relaxation times measured with an optimized MRF sequence for low field were in better agreement with reference techniques than for a standard MRF sequence. In vivo muscle relaxation times measured with MRF were longer than those obtained with an IR sequence (T1: 182 ± 21.5 vs 168 ± 9.89 ms) and with an MESE sequence (T2: 69.8 ± 19.7 vs 46.1 ± 9.65 ms). In vivo lipid MRF relaxation times were also longer compared with IR (T1: 165 ± 15.1 ms vs 127 ± 8.28 ms) and with MESE (T2: 160 ± 15.0 ms vs 124 ± 4.27 ms). Integrated ΔB0 estimation and correction resulted in parameter maps with reduced distortions. Discussion: It is possible to measure volumetric relaxation times with MRF at 2.5 × 2.5 × 3.0 mm3 resolution in a 13 min scan time on a 50 mT permanent magnet system. The measured MRF relaxation times are longer compared to those measured with reference techniques, especially for T2. This discrepancy can potentially be addressed by hardware, reconstruction and sequence design, but long-term reproducibility needs to be further improved.


  • Open Access

    Mitigating undersampling errors in MR fingerprinting by sequence optimization

    by David G.J. Heesterbeek, Kirsten Koolstra, Matthias J.P. van Osch, Martin B. van Gijzen, Franciscus M. Vos, Martijn A. Nagtegaal

    Purpose: To develop a method for MR Fingerprinting (MRF) sequence optimization that takes both the applied undersampling pattern and a realistic reference map into account.Methods: A predictive model for the undersampling error leveraging on perturbation theory was exploited to optimize the MRF flip angle sequence for improved robustness against undersampling artifacts. In this framework parameter maps from a previously acquired MRF scan were used as reference. Sequences were optimized for different sequence lengths, smoothness constraints and undersampling factors. Numerical simulations and in vivo measurements in eight healthy subjects were performed to assess the effect of the performed optimization. The optimized MRF sequences were compared to a conventionally shaped flip angle pattern and an optimized pattern based on the Cramér–Rao lower bound (CRB).Results: Numerical simulations and in vivo results demonstrate that the undersampling errors can be suppressed by flip angle optimization. Analysis of the in vivo results show that a sequence optimized for improved robustness against undersampling with a flip angle train of length 400 yielded significantly lower median absolute errors in : and : compared to the conventional (: , : ) and CRB‐based (: , : ) sequences.Conclusion: The proposed method is able to optimize the MRF flip angle pattern such that significant mitigation of the artifacts from strong k‐space undersampling in MRF is achieved.


  • Open Access

    Multicomponent MR fingerprinting reconstruction using joint‐sparsity and low‐rank constraints

    by Martijn Nagtegaal, Emiel Hartsema, Kirsten Koolstra, Frans Vos

    Purpose: To develop an efficient algorithm for multicomponent MR fingerprinting (MC‐MRF) reconstructions directly from highly undersampled data without making prior assumptions about tissue relaxation times and expected number of tissues.Methods: The proposed method reconstructs MC‐MRF maps from highly undersampled data by iteratively applying a joint‐sparsity constraint to the estimated tissue components. Intermediate component maps are obtained by a low‐rank multicomponent alternating direction method of multipliers (MC‐ADMM) including the non‐negativity of tissue weights as an extra regularization term. Over iterations, the used dictionary compression is adjusted. The proposed method (k‐SPIJN) is compared with a two‐step approach in which image reconstruction and multicomponent estimations are performed sequentially and tested in numerical simulations and in vivo by applying different undersampling factors in eight healthy volunteers. In the latter case, fully sampled data serves as the reference.Results: The proposed method shows improved precision and accuracy in simulations compared with a state‐of‐art sequential approach. Obtained in vivo magnetization fraction maps for different tissue types show reduced systematic errors and reduced noise‐like effects. Root mean square errors in estimated magnetization fraction maps significantly reduce from 13.0% 5.8% with the conventional, two‐step approach to 9.6% 3.9% and 9.6% 3.2% with the proposed MC‐ADMM and k‐SPIJN methods, respectively. Mean standard deviation in homogeneous white matter regions reduced significantly from 8.6% to 2.9% (two step vs. k‐SPIJN).Conclusion: The proposed MC‐ADMM and k‐SPIJN reconstruction methods estimate MC‐MRF maps from highly undersampled data resulting in improved image quality compared with the existing method.


  • Open Access

    Water/fat separation for self‐navigated diffusion‐weighted multishot echo‐planar imaging

    by Yiming Dong, Malte Riedel, Kirsten Koolstra, Matthias J. P. van Osch, Peter Börnert

    The purpose of this study was to develop a self‐navigation strategy to improve scan efficiency and image quality of water/fat‐separated, diffusion‐weighted multishot echo‐planar imaging (ms‐EPI). This is accomplished by acquiring chemical shift‐encoded diffusion‐weighted data and using an appropriate water‐fat and diffusion‐encoded signal model to enable reconstruction directly from k‐space data. Multishot EPI provides reduced geometric distortion and improved signal‐to‐noise ratio in diffusion‐weighted imaging compared with single‐shot approaches. Multishot acquisitions require corrections for physiological motion‐induced shot‐to‐shot phase errors using either extra navigators or self‐navigation principles. In addition, proper fat suppression is important, especially in regions with large B0 inhomogeneity. This makes the use of chemical shift encoding attractive. However, when combined with ms‐EPI, shot‐to‐shot phase navigation can be challenging because of the spatial displacement of fat signals along the phase‐encoding direction. In this work, a new model‐based, self‐navigated water/fat separation reconstruction algorithm is proposed. Experiments in legs and in the head–neck region of 10 subjects were performed to validate the algorithm. The results are compared with an image‐based, two‐dimensional (2D) navigated water/fat separation approach for ms‐EPI and with a conventional fat saturation approach. Compared with the 2D navigated method, the use of self‐navigation reduced the shot duration time by 30%–35%. The proposed algorithm provided improved diffusion‐weighted water images in both leg and head–neck regions compared with the 2D navigator‐based approach. The proposed algorithm also produced better fat suppression compared with the conventional fat saturation technique in the B0 inhomogeneous regions. In conclusion, the proposed self‐navigated reconstruction algorithm can produce superior water‐only diffusion‐weighted EPI images with less artefacts compared with the existing methods.


  • Open Access

    Subject‐specific optimization of background suppression for arterial spin labeling magnetic resonance imaging using a feedback loop on the scanner

    by Kirsten Koolstra, Marius Staring, Paul de Bruin, Matthias J. P. van Osch

    Background suppression (BGS) in arterial spin labeling (ASL) magnetic resonance imaging leads to a higher temporal signal‐to‐noise ratio (tSNR) of the perfusion images compared with ASL without BGS. The performance of the BGS, however, depends on the tissue relaxation times and on inhomogeneities of the scanner's magnetic fields, which differ between subjects and are unknown at the moment of scanning. Therefore, we developed a feedback loop (FBL) mechanism that optimizes the BGS for each subject in the scanner during acquisition. We implemented the FBL for 2D pseudo‐continuous ASL scans with an echo‐planar imaging readout. After each dynamic scan, the acquired ASL images were automatically sent to an external computer and processed with a Python processing tool. Inversion times were optimized on the fly using 80 iterations of the Nelder–Mead method, by minimizing the signal intensity in the label image while maximizing the signal intensity in the perfusion image. The performance of this method was first tested in a four‐component phantom. The regularization parameter was then tuned in six healthy subjects (three males, three females, age 24–62 years) and set as λ = 4 for all other experiments. The resulting ASL images, perfusion images, and tSNR maps obtained from the last 20 iterations of the FBL scan were compared with those obtained without BGS and with standard BGS in 12 healthy volunteers (five males, seven females, age 24–62 years) (including the six volunteers used for tuning of λ). The FBL resulted in perfusion images with a statistically significantly higher tSNR (2.20) compared with standard BGS (1.96) ( , two‐sided paired t‐test). Minimizing signal in the label image furthermore resulted in control images, from which approximate changes in perfusion signal can directly be appreciated. This could be relevant to ASL applications that require a high temporal resolution. Future work is needed to minimize the number of initial acquisitions during which the performance of BGS is reduced compared with standard BGS, and to extend the technique to 3D ASL.


  • Open Access

    Learning a preconditioner to accelerate compressed sensing reconstructions in MRI

    by Kirsten Koolstra, Rob Remis

    Purpose To learn a preconditioner that accelerates parallel imaging (PI) and compressed sensing (CS) reconstructions. Methods A convolutional neural network (CNN) with residual connections was used to train a preconditioning operator. Training and validation data were simulated using 50% brain images and 50% white Gaussian noise images. Each multichannel training example contains a simulated sampling mask, complex coil sensitivity maps, and two regularization parameter maps. The trained model was integrated in the preconditioned conjugate gradient (PCG) method as part of the split Bregman CS method. The acceleration performance was compared with that of a circulant PI-CS preconditioner for varying undersampling factors, number of coil elements and anatomies. Results The learned preconditioner reduces the number of PCG iterations by a factor of 4, yielding a similar acceleration as an efficient circulant preconditioner. The method generalizes well to different sampling schemes, coil configurations and anatomies. Conclusion It is possible to learn adaptable preconditioners for PI and CS reconstructions that meet the performance of state-of-the-art preconditioners. Further acceleration could be achieved by optimizing the network architecture and the training set. Such a preconditioner could also be integrated in fully learned reconstruction methods to accelerate the training process of unrolled networks.


  • Open Access

    Stochastic neighbor embedding as a tool for visualizing the encoding capability of magnetic resonance fingerprinting dictionaries

    by Kirsten Koolstra, Peter Börnert, Boudewijn P. F. Lelieveldt, Andrew Webb, Oleh Dzyubachyk

    Objective: To visualize the encoding capability of magnetic resonance fingerprinting (MRF) dictionaries. Materials and methods: High-dimensional MRF dictionaries were simulated and embedded into a lower-dimensional space using t-distributed stochastic neighbor embedding (t-SNE). The embeddings were visualized via colors as a surrogate for location in low-dimensional space. First, we illustrate this technique on three different MRF sequences. We then compare the resulting embeddings and the color-coded dictionary maps to these obtained with a singular value decomposition (SVD) dimensionality reduction technique. We validate the t-SNE approach with measures based on existing quantitative measures of encoding capability using the Euclidean distance. Finally, we use t-SNE to visualize MRF sequences resulting from an MRF sequence optimization algorithm. Results: t-SNE was able to show clear differences between the color-coded dictionary maps of three MRF sequences. SVD showed smaller differences between different sequences. These findings were confirmed by quantitative measures of encoding. t-SNE was also able to visualize differences in encoding capability between subsequent iterations of an MRF sequence optimization algorithm. Discussion: This visualization approach enables comparison of the encoding capability of different MRF sequences. This technique can be used as a confirmation tool in MRF sequence optimization.


  • Open Access

    Regularized joint water–fat separation with B0 map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI

    by Yiming Dong, Kirsten Koolstra, Malte Riedel, Matthias J. P. van Osch, Peter Börnert

    Purpose: To develop a new water–fat separation and B0 estimation algorithm to effectively suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI where fat is often a confounding factor.Methods: Water–fat separation based on chemical‐shift encoding enables robust fat suppression in routine MRI. However, for EPI the different chemical‐shift displacements of the multiple fat resonances along the phase‐encoding direction can be problematic for conventional separation algorithms. This work proposes a suitable model approximation for EPI under B0 and fat off‐resonance effects, providing a feasible multi‐peak water–fat separation algorithm. Simulations were performed to validate the algorithm. In vivo validation was performed in 6 volunteers, acquiring spin‐echo EPI images in the leg (B0 homogeneous) and head‐neck (B0 inhomogeneous) regions, using a TE‐shifted interleaved EPI sequence with/without diffusion sensitization. The results are numerically and statistically compared with voxel‐independent water–fat separation and fat saturation techniques to demonstrate the performance of the proposed algorithm.Results: The reference separation algorithm without the proposed spatial shift correction caused water–fat ambiguities in simulations and in vivo experiments. Some spectrally selective fat saturation approaches also failed to suppress fat in regions with severe B0 inhomogeneities. The proposed algorithm was able to achieve improved fat suppression for DWI data and ADC maps in the head–neck and leg regions.Conclusion: The proposed algorithm shows improved suppression of the multi‐peak fat components in multi‐shot interleaved EPI applications compared to the conventional fat saturation approaches and separation algorithms.