Jiwon Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jiwon Choi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Dae Cheol Kweon
Department of Radiological Science, Shinhan University, Uijeongbu, Republic of Korea
4 shared publications - Jong-Woong Lee
Kyung Hee University Hospital at Gang-dong
4 shared publications Dae Cheol Kweon
Department of Radiological Science, Shinhan University, Uijeongbu, Republic of Korea
3 shared publications- Eun-Hoe Goo
Seoul National University Hospital
2 shared publications Dong Yong Lee
1 shared publicationEun-Soo Kim
Department of Electronic Engineering, Kwangwoon University, Seoul 139-701, Korea
1 shared publication
Latest Publications
- 28 February 2025
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 48 (1) , 19-29
A Study of Licensing and Education Programs for Medical Radiation Practitioners in Australia: Focused on Diagnostic Radiographer
- 28 February 2025
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 48 (1) , 19-29
A Study of Licensing and Education Programs for Medical Radiation Practitioners in Australia: Focused on Diagnostic Radiographer
- 12 April 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 81 (1) , 1-9
Protection of superficial organs using bismuth and iodine shielding during computed tomography in phantoms
- 12 April 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 81 (1) , 1-9
Protection of superficial organs using bismuth and iodine shielding during computed tomography in phantoms
- 20 November 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 187 (4) , 535-539
Proposed Dose Constraints in the Duties of Radiation Workers at the Department of Nuclear Medicine
This study aimed to set a dose constraint for certain duties of radiological technologists in the department of nuclear medicine. From 2013 to 2017, the 5 y radiation exposure data of employees performing PET-CT and γ-CAMERA of eight hospitals in Korea were measured individual exposure doses to estimate the frequency and set a representative dose of 75 and 95% from the low dose in the whole category is presented. The dose constraint was 5.5 mSv for PET-CT, 4.5 mSv for γ-CAMERA and 3.5 mSv for Positron Emission Tomography (PET)-Computed Tomography(CT) and Gamma CAMERA (γ-CAMERA). Therefore, it would be appropriate to set a dose-limit value of ~5 mSv corresponding to 75–80% of the individual exposure dose of radiological technologists in the department of nuclear medicine. The finding of this study may be used as reference data for setting future radiation dose limits.
- 20 November 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 187 (4) , 535-539
Proposed Dose Constraints in the Duties of Radiation Workers at the Department of Nuclear Medicine
This study aimed to set a dose constraint for certain duties of radiological technologists in the department of nuclear medicine. From 2013 to 2017, the 5 y radiation exposure data of employees performing PET-CT and γ-CAMERA of eight hospitals in Korea were measured individual exposure doses to estimate the frequency and set a representative dose of 75 and 95% from the low dose in the whole category is presented. The dose constraint was 5.5 mSv for PET-CT, 4.5 mSv for γ-CAMERA and 3.5 mSv for Positron Emission Tomography (PET)-Computed Tomography(CT) and Gamma CAMERA (γ-CAMERA). Therefore, it would be appropriate to set a dose-limit value of ~5 mSv corresponding to 75–80% of the individual exposure dose of radiological technologists in the department of nuclear medicine. The finding of this study may be used as reference data for setting future radiation dose limits.
- Open Access
- 15 October 2019
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 16 (4)
Effect of Arm Position on Image Quality and Radiation Dose in Multidetector Computed Tomography
Abdominal CT using a tube-current modulation technique may result in artifacts due to changes in the position of the patient’s arms, resulting in poor image ...
- 15 October 2019
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 16 (4)
Open AccessEffect of Arm Position on Image Quality and Radiation Dose in Multidetector Computed Tomography
Abdominal CT using a tube-current modulation technique may result in artifacts due to changes in the position of the patient’s arms, resulting in poor image ...
- 12 November 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 73 (9) , 1377-1384
Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector
Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of 0.008226 cm2/g, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was 2.699 g/cm3. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of 75.33 μGy and a depth dose of 71.77 μGy, those with regard to the OSL were surface dose of 9.2 μGy a depth dose of 70.39 μGy and a mean dose of 74.79 μGy. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were 0.742 μSv, 8.9 μSv, 2.96 μSv and those for the OSL were 0.754 μSv, 9.05 μSv, and 3.018 μSv in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.
- 12 November 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 73 (9) , 1377-1384
Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector
Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of 0.008226 cm2/g, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was 2.699 g/cm3. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of 75.33 μGy and a depth dose of 71.77 μGy, those with regard to the OSL were surface dose of 9.2 μGy a depth dose of 70.39 μGy and a mean dose of 74.79 μGy. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were 0.742 μSv, 8.9 μSv, 2.96 μSv and those for the OSL were 0.754 μSv, 9.05 μSv, and 3.018 μSv in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.
- 31 March 2016
- Published by The Korean Magnetics Society in Journal of Magnetics
- Vol. 21 (1) , 115-124
Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging
- 31 March 2016
- Published by The Korean Magnetics Society in Journal of Magnetics
- Vol. 21 (1) , 115-124
Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging
- 17 September 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 169 (2) , 165-174
Measurement of X-ray for the dose area product and spectrum by the added filtration in Rando phantom
The most important point in the medical use of radiation is to minimize the patient entrance dose while maintaining the diagnostic information. Low-energy photons (long-wave X-ray) are unnecessary among diagnostic X-ray because they are mostly absorbed and increase the patient's entrance dose. The most effective method to eliminate the low-energy photon is use of a filtering plate. Using a filter appropriate for the image will maintain diagnostic value. Obtaining an effective image allows comparison of the resulting images in a logical objective way. This experiment was performed to determine the quality of image dosimeter when there is no filter, and when 2 mm Al, 0.1 mm Cu + 1 mm Al, 0.2 mm Cu + 1 mm Al filters are used. Using TORECK PD-8100 dose area products meter placed on top of an abdominal phantom, we measured the dose when the filter changes in this condition 85 kVp, 40 mAs, anode angle 13, source image distance 100 cm, 20 cm × 20 cm. We used the SRS-78 program for accurate comparison because we could not evaluate the difference in the image optically. The spectrum changed due to the emission of X-rays as the filter changed. We observed that the use of a filter eliminated the low-energy photons and revealed continuous X-ray and special X-ray. Therefore, the experiment highlighted the advantages of filters and confirmed that there are no changes in the quality of image through signal to noise ratio, peak signal to noise ratio, root mean square error comparison. We found that the use of filter did not lead to distortions in the image or drop in diagnostic value while minimizing the radiation dose. This means that it can help manage long-term patient dose. We conclude that we need to recommend the use of the filter as it reduces the area of dose.
- 17 September 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 169 (2) , 165-174
Measurement of X-ray for the dose area product and spectrum by the added filtration in Rando phantom
The most important point in the medical use of radiation is to minimize the patient entrance dose while maintaining the diagnostic information. Low-energy photons (long-wave X-ray) are unnecessary among diagnostic X-ray because they are mostly absorbed and increase the patient's entrance dose. The most effective method to eliminate the low-energy photon is use of a filtering plate. Using a filter appropriate for the image will maintain diagnostic value. Obtaining an effective image allows comparison of the resulting images in a logical objective way. This experiment was performed to determine the quality of image dosimeter when there is no filter, and when 2 mm Al, 0.1 mm Cu + 1 mm Al, 0.2 mm Cu + 1 mm Al filters are used. Using TORECK PD-8100 dose area products meter placed on top of an abdominal phantom, we measured the dose when the filter changes in this condition 85 kVp, 40 mAs, anode angle 13, source image distance 100 cm, 20 cm × 20 cm. We used the SRS-78 program for accurate comparison because we could not evaluate the difference in the image optically. The spectrum changed due to the emission of X-rays as the filter changed. We observed that the use of a filter eliminated the low-energy photons and revealed continuous X-ray and special X-ray. Therefore, the experiment highlighted the advantages of filters and confirmed that there are no changes in the quality of image through signal to noise ratio, peak signal to noise ratio, root mean square error comparison. We found that the use of filter did not lead to distortions in the image or drop in diagnostic value while minimizing the radiation dose. This means that it can help manage long-term patient dose. We conclude that we need to recommend the use of the filter as it reduces the area of dose.
- Retracted
- 15 February 2011
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 58 (2) , 334-342
Measurement of Image Quality in CT Images Reconstructed with Different Kernels
- 15 February 2011
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 58 (2) , 334-342
RetractedMeasurement of Image Quality in CT Images Reconstructed with Different Kernels